• Title/Summary/Keyword: catheter

Search Result 1,085, Processing Time 0.028 seconds

Development of a Practice Guideline for Catheter Dysfunction in Hemodialysis Patients (혈액투석 환자의 기능부전 도관관리 실무지침개발)

  • Lee, Kyung Mi;Kim, Mi Yeun;Hong, Jin Young;Cho, Yong Ae;Yang, Won Ji
    • Journal of Korean Clinical Nursing Research
    • /
    • v.22 no.2
    • /
    • pp.238-247
    • /
    • 2016
  • Purpose: This study was done to develop an evidence-based practice guideline for catheter dysfunction in hemodialysis patients. Methods: Development of the guideline process was done according to the De Novo development version 1.0 by NECA which consists of 12 steps. Results: The developed guideline consisted of 5 domains and 14 recommendations. The number of recommendations for each domain were: 3 on catheter dysfunction assessment, 1 on conservative management of catheter dysfunction, 7 on drug management of catheter dysfunction, 1 on catheter function test and 2 on maintenance management. Of the recommendations, 7.15% were marked as A grade, 52.85% of B grade, and 50% of C grade. Conclusion: Findings in this study indicate that this guideline can be added to the evidence-based practice guidelines for fundamentals of practice and that this guideline can be disseminated to nurses nationwide in order to improve the care of hemodialysis patients with catheter dysfunction.

Cardiac Output Measurement Platform Development Using Swan-Ganz Catheter in Cardiopulmonary Patients with More Accurate (Swan-Ganz Catheter를 이용한 심폐기능 이상자의 정확한 Cardiac Output 측정 플랫폼 개발)

  • Jeong, Yong-Hyun;Na, Sang-Sin;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1591-1597
    • /
    • 2011
  • In this paper, on cardiopulmonary function in the intensive care unit over the direction of the state to define the diagnostic or therapeutic cardiac output Study on Implementation of measures as a platform, Swan-Ganz Catheter with sensor inserted into the body by inserting a saline solution Using temperature change caused by using thermodilution be used to obtain cardiac output. Swan-Ganz Catheter with temperature sensors and pressure sensors and sensor value which is entered through the acquisition more closely if the cardiac output CO, systemic and pulmonary vascular resistance, oxygen consumption and may be able to more accurately calculate the patient's condition than accurate diagnosis and treatment is possible.

Device for Catheter Placement of External Ventricular Drain

  • Ann, Jae-Min;Bae, Hack-Gun;Oh, Jae-Sang;Yoon, Seok-Mann
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.322-324
    • /
    • 2016
  • To introduce a new device for catheter placement of an external ventricular drain (EVD) of cerebrospinal fluid (CSF). This device was composed of three portions, T-shaped main body, rectangular pillar having a central hole to insert a catheter and an arm pointing the tragus. The main body has a role to direct a ventricular catheter toward the right or left inner canthus and has a shallow longitudinal opening to connect the rectangular pillar. The arm pointing the tragus is controlled by back and forth movement and turn of the pillar attached to the main body. Between April 2012 and December 2014, 57 emergency EVDs were performed in 52 patients using this device in the operating room. Catheter tip located in the frontal horn in 52 (91.2%), 3rd ventricle in 2 (3.5%) and in the wall of the frontal horn of the lateral ventricle in 3 EVDs (5.2%). Small hemorrhage along to catheter tract occurred in 1 EVD. CSF was well drained through the all EVD catheters. The accuracy of the catheter position and direction using this device were 91% and 100%, respectively. This device for EVD guides to provide an accurate position of catheter tip safely and easily.

Catheter Embolism during Chemoport Removal (Chemoport 제거 중 발생한 카테터 색전증)

  • Song, Ki-Byung;Nam, So-Hyun;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, Young-Hwue;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.12 no.2
    • /
    • pp.238-243
    • /
    • 2006
  • Chemoport is widely used in pediatric surgery field. But various complications can occur during the process of insertion or removal of chemoport. Surgeons must be familiar with the treatment of these complications. We had one catheter cuts off during chemoport removal, become a catheter embolism. Interventional radiologic removal was successful. Verifying the length of removed catheter and careful observation of the catheter tip during removal procedure is important to prevent the possibility of catheter embolus. Radiologic intervention was accessible to remove the retained catheter.

  • PDF

Sternal Retraction and Subclavian Vein Catheter Occlusion during Cardiac Surgery

  • Tarbiat, Masoud;Bakhshaei, Mohammad Hossein;Derakhshanfar, Amir;Rezaei, Mahmoud;Ghorbanpoor, Manoochehr;Zolhavarieh, Seyed Mohammad
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.377-382
    • /
    • 2021
  • Background: Subclavian vein (SV) catheterization is a method for the delivery of fluids, drugs, and blood products, venous blood sampling, and central vein pressure monitoring in cardiac surgery. Catheter occlusion is a serious complication of SV catheterization during cardiac surgery, especially after sternal retractor expansion. Methods: In this observational study, 303 patients who had successful right infraclavicular SV catheterization from September 2019 to April 2020 were enrolled to determine the incidence of catheter occlusion. After catheterization, the lumens of all catheters were checked for the ability to infuse and withdraw blood from the catheter before and after sternal retractor expansion. The patients' characteristics, cannulation approach, on-pump or off-pump technique, occlusion of the catheter and its lumens, and any associated complications were recorded. The data were analyzed using IBM SPSS ver. 22.0 (IBM Corp., Armonk, NY, USA). Results: Of the 303 patients studied, 205 were male (67.7%) and 98 were female (32.3%). Catheter occlusion occurred in 11 patients with on-pump cardiopulmonary bypass (CPB) (227 patients) and 4 patients with off-pump CPB (76 patients) (p=0.863). The incidence of catheter occlusion was 4.95% (15 of 303 patients) with no cases of simultaneous 3-lumen occlusion in a catheter. The most commonly occluded lumen was the distal lumen (57.92%). Simultaneous 2-lumen occlusion occurred in 4 patients. Catheter occlusion was found in 3 of 13 malpositioned catheters (23.07%). Conclusion: The current study showed that malpositioning of the catheter tip was a risk factor for catheter occlusion and that the distal lumen of a triple-lumen catheter was the most commonly occluded lumen.

Accurate Placement of Parieto-occipital Ventricular Catheter Using CT Parameters (CT 지표를 이용한 두정-후두부 뇌실 도관의 정확한 삽입)

  • Min, Hyung-Sik;Song, Jun-Hyeok
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.886-890
    • /
    • 2000
  • Objective : placement of ventricular catheter is important to achieve long-term patency of the shunt system. We describe a method of calculating the insertion site, trajectory, and the length of the ventricular catheter using CT parameters in shunt surgery. Patients and Methods : These can be rapidly obtained using a caliper from a scout cut and two axial scans at lateral ventricular and upper 3rd ventricular level. To compare this technique with traditional one, we analyzed 40 consecutive patients who underwent shunt surgery. Results : Of 20 patients undergoing ventriculoperitoneal shunt insertion using this technique, none had poor location of the proximal catheter. In the counterpart, 9 patients had poor location(p=0.001). The number of patients who required revision surgery were also lower in the group using this technique, but it was not statistically significant (4 versus 2, p=0.422). Mean follow-up period was shorter in this technique group. Conclusion : This technique provides an accurate placement of the proximal catheter without special instrument or additional expenses.

  • PDF

Upward Migration of a Peritoneal Catheter Following Ventriculoperitoneal Shunt

  • Cho, Kyung Rae;Yeon, Je Young;Shin, Hyung Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.383-385
    • /
    • 2013
  • We present an unusual case of peritoneal catheter migration following a ventriculoperitoneal shunt operation. A 7-month-old infant, who had suffered from intraventricular hemorrhage at birth, was shunted for progressive hydrocephalus. The peritoneal catheter, connected to an 'ultra small, low pressure valve system' (Strata$^{(R)}$; PS Medical,Gola, CA, USA) at the subgaleal space, was placed into the peritoneal cavity about 30 cm in length. The patient returned to our hospital due to scalp swelling 21 days after the surgery. Simple X-ray images revealed total upward migration and coiling of the peritoneal catheter around the valve. Possible mechanisms leading to proximal upward migration of a peritoneal catheter are discussed.

Use of Cardiac Computed Tomography and Magnetic Resonance Imaging in Case Management of Atrial Fibrillation with Catheter Ablation

  • Hee-Gone Lee;Jaemin Shim;Jong-il Choi;Young-Hoon Kim;Yu-Whan Oh;Sung Ho Hwang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.695-708
    • /
    • 2019
  • Atrial fibrillation (AF) is the most common arrhythmia associated with the risk of morbidity and mortality in clinical patients. AF is considered as an arrhythmia type that develops and progresses through close connection with cardiac structural arrhythmogenic substrates. Since the introduction of catheter ablation-mediated electrical isolation of arrhythmogenic substrates, cardiac imaging indicates improved treatment outcome and prognosis with appropriate candidate selection, ablation catheter guidance, and post-ablation follow-up. Currently, cardiac computed tomography (CCT) and cardiovascular magnetic resonance (CMR) imaging are essential in the case management of AF at both pre-and post-procedural stages of catheter ablation. In this review, we discuss the roles and technical considerations of CCT and CMR imaging in the management of patients with AF undergoing catheter ablation.

Urinary Tract Infection Related to The Indwelling Cathete with Closed Drainage (도뇨환자의 유치기간별 요로감염상태에 관한 연구)

  • 이경심;박형숙
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.3
    • /
    • pp.345-363
    • /
    • 1994
  • This study attempted to identify important problems of the factors related to the indwelling catheter with closed drainage and to enhance recognization of Urinary Tract Infection management to protect patients with indwelling catheter from UTI. We selected the 58 patients with indwelling catheter with closed drainage from md-surg. intensive care units, and general neurological and neurosurgical ward, in one hospital in Pusan, Korea from May 30 to October 15, 1993. Patients were examined by urinary analysis before inserting catheter and then by urine cultures three times. The obtained data was analized using an SPSS /PC$^{+}$ The statistical analyses employed here was the frequency, percentage and x$^2$-tests. 1. Analyses for Indwelling Catheter induced UTI and infection rates were found to be presented in patients related to the factors of being on antibiotic drugs (x$^2$=14.105, p=.000) and the duration of the indwelling catheter(x$^2$=58.0, p=.000), both of which were found to affect the UTI. 2. UTI rates according to the duration of the in-dwelling catheter were high 8.6% for the 2nd day, 27.6 for the 4th day, and 36.2% for the 7th day, and as the duration for the indwelling catheter was longer, UTI rates were higher. 3. The UTI rates according to the duration of the indwelling catheter related re factors, on the 7th day, were high-52.0% for women, 37.0% for more than 50 years in ages, 30.0% for patients under sur-gery, 33.3% for altered mental states outsides the alert, 76.7% for patients not given antibiotic drugs, 36.4% for less than 3500cc of fluids intakes, it was found that these affected to increase the UTI. 4. Causative organisms of UTI were found ; E.Coli appears the most than all other isolated organisms in women and Klebsiella and Pseudomonas in men. For antibiotic susceptibility of causative organisms, all causative organisms were found to be susceptible to Sul -cefoperazone, Trim-prim, and unasyn and Pseudomonas mostly net susceptible.e.

  • PDF

Invention of the Guide Catheter Irrigation Monitoring Device for Neuroendovascular Therapy

  • Ozkul, Ayca;Park, Jong-Hyun;Shin, Dong-Seung;Yilmaz, Ali;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.471-474
    • /
    • 2017
  • Objective : The thromboembolic events during neuroendovascular therapy (NET) are the major complications of concern that can be occasionally fatal. The thrombotic occlusion of the guide catheter for NET is thought to be the risk of the thromboembolic events. We have developed an idea for inventing the monitoring system of the continuous irrigation through the guide catheter. We herein present a unique invention of the guide catheter irrigation monitoring device. Methods : We have developed ideas for preventing the thrombotic occlusion of the guide catheter. In order to design a convenient device working in the practical use, we have consulted and shared the ideas with the electrical engineers about putting the invention. Results : The guide catheter irrigation monitoring device (GCIMD) consisted of three parts of optical sensor, main body and electric adapter. In brief, the basic principles of working of the GCIMD are as follows. The optical sensor is attached to the dripping chamber of the line to irrigation solution. The main body had the small light and speaker to make an alarm sounds. The sensor monitors the dripping of flush solution. If the dripping stops more than three seconds, a warning alarm has been activated. So, the operating physicians can concentrate and check the guide catheter irrigation. After the use of the GCIMD, there was no major thromboembolic complication in conjunction with the thrombotic occlusion of the guide catheter in our institute. Conclusion : We have developed a brilliant invention of the GCIMD for NET.