• Title/Summary/Keyword: catenary line

Search Result 177, Processing Time 0.027 seconds

A Study on the Form of Electric Shock Accident Using Swiss Cheese Model (스위스 치즈 모델을 적용한 철도 감전사고 발생형태에 관한 연구)

  • Yu, Ki-Seong;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1711-1716
    • /
    • 2018
  • Unlike conventional transmission and distribution lines, catenary system for operating electric railway vehicles are composed of multi-conductor groups (feeder line, contact wire, messenger wire, protection wire) and are used for railway employees, public or passengers in the station yards. Electric shock hazards are exposed and electric shocks such as death or serious injury are occurring in electric railway vehicles, railway high-voltage distribution lines, and catenary system. In order to analyze the types of electric shock accidents on railway by systematic approach method, we modeled 'unsafe behavior classification' method using swiss cheese model. Based on this method, we derived the type of electric shock accidents about railway accidents during the last 5 years by analyzing the frequency of occurrence of human errors and unsafe acts, laws and regulations related to violations, and so on.

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.

Analysis of Magnetic Field on Ultra High Voltage ac Transmission Line (초고압 송전선로의 자계해석에 관한 연구)

  • Lee, Joo-Youl;Ko, Eun-Young;Jung, Ho-Sung;Shin, Myung-Chul;Kweon, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1382-1384
    • /
    • 1999
  • Traditional magnetic field computation techniques assume that the current carrying power line conductors are straight horizontal wires. This assumption result in much errors. So this paper considerd catenary curve for the dip of real transmission line. We have data from various position at transmission line, on the earth. And as far from transmission condutor a eddy current affect of the position are con siderd.

  • PDF

A Modeling and Simulation Implementation on the Power Line Disturbances by Loss of Contact for the High-Speed Railway Vehicle (고속전철 주행시 이선에 따른 전원외란 현상 모델링 및 시뮬레이션 구현)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young;Gimm, Yoon-Myoung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1137-1142
    • /
    • 2008
  • In this paper, an effect on power conversion unit in high-speed railway vehicle by loss of contact between a catenary system and pantograph suppling electrical power to high-speed railway vehicle are investigated. One of the most important needs accompanied by increasing the speed of high-speed railway vehicle is reduced that arc phenomenon by loss of contact brings out EMI. in case of high-speed railway vehicle using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occur. To analysis the effect on loss of contact, it is necessary electrical modeling system between the contact line and the pantograph according to the loss of contact. Therefore analytical model of a contact line and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on kinds of loss of contact.

  • PDF

A Development of Pulley-type Tensioning Device for a High Speed Railway (고속용 풀리형식 장력조정장치 개발)

  • Cho, Yong-Hyeon;Kwon, Sam-Young;Park, Young;Lee, Ki-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.723-730
    • /
    • 2006
  • In the electrical railway, the tension ascension of contact wire is essential to speed up of train and current collection performance of catenary largely depends on the tension. The tension variation rate of the tensioning device used in existing line limits within 5%, and the tension variation rate of the spring-type tensioning device installed at the section where tensioning length is short bounds within 15%. So it is urgent for us to localize it for high speed line, which the tension variation rate is limited within 3%. Therefore in this study, a pulley-type tensioning device for high speed line is developed. To verify the performance of developed device, a performance test, overload test and failure test is carried out under the code of the Kyung-Bu High Speed line. And it is secured durability performance through a fatigue test.

  • PDF

Implementation of Optical-based Measuring Instrument for Overhead Contact Wire in Railway (전기철도 전차선로의 광학기반 형상 검측 하드웨어 구현)

  • Park, Young;Cho, Yong-Hyeon;Park, Hyun-June;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.518-518
    • /
    • 2008
  • We propose an optical-based measuring instrument of catenary system in electric railway. This system was made to utilize line scan camera as inspecting system to measure the stagger and height of overhead contact wire in railway and composed with optical type source and FPGA-based image acquisition system with PCI slot. Vision acquisition software has been used for the application to programming interface for image acquisition, display, and storage with a frequency of sampling. The proposed optical-based measuring instrument to measure the contact wire geometry shows promising on-field applications for online condition motoring. Also, this system can be applied to measure the hight and stagger or other geometry of different type of overhead catenary system.

  • PDF

Evaluation of Behaviors on Mooring Line Embedded in Sand Using Centrifuge Test (원심모형실험을 이용한 모래지반에 관입된 계류선 거동 평가)

  • Lee, Hoon Yong;Kim, Surin;Kim, Jaehyun;Kim, Dong-Soo;Choo, Yun Wook;Kwo, Osoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.47-54
    • /
    • 2014
  • When an anchor penetrates and is installed under a seabed, a portion of the mooring line connected to the anchor is also embedded under the seabed. This embedded mooring line affects the capacity of the anchor in two ways. First, the frictional resistance that occurs between the mooring line and the seabed reduces the pulling force acting on the anchor. Second, the embedded part of the mooring line forms a reverse catenary shape due to the bearing resistance of the soil, so that an inclined pulling force is applied to the anchor. To evaluate the mooring line's effect on the capacity of an anchor in sand, centrifuge model tests were performed using two relative sand densities of 76% and 51% while changing the anchor depths. The test results showed that the load is reduced much more in deep and dense sand, and the inclination angle of the load is lower in shallow and loose sand.

Common Earth Network constitution for minimize surge damage (낙뢰 피해 최소화를 위한 공동 접지망 구성)

  • Kim, Yong-Kyu;Baek, Jong-Hyun;Choi, Kyoung-Il;Yoo, Keun-Su
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.190-195
    • /
    • 2008
  • Surge proof equipment is an installation to make surge flow on the ground promptly so as to reduce surge-related damage on infrastructure, not to prevent surge from falling down on infrastructure directly. Compared with classical line individual earth, High speed line common earth has higher surge characteristic and plays a significant role to prevent infrastructure damage and injuries from surge, or short circuit accident between 25kV catenary and rail. In this paper, we analyzed the case of accident that caused communication/signaling system impaired while a tractor crossing level crossing at Honam line; in addition, we examined the accident reduction measures to minimize injury and property damage from cutting accidents with respect to common earth network.

  • PDF

Comparative Study on Wave Induced Fatigue Analysis Methods for Steel Catenary Riser (파랑하중에 의한 Steel Catenary Riser 피로손상 평가 방법의 비교검토)

  • Lee, Jeong-Dae;Lee, Sung-Je;Jang, Chang-Hwan;Jun, Seock-Hee;Oh, Yeong-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.3
    • /
    • pp.222-235
    • /
    • 2015
  • The purpose of this study is to suggest guidelines for riser fatigue analysis in terms of selection of reasonable analysis method. Three analysis methods (spectral, regular wave, rain-flow counting) are introduced and compared. As the riser systems give non-linear response, the time-domain analysis method is more preferred than frequency-domain analysis method. The spectral fatigue analysis method, however, is still useful for identifying fatigue prone areas. Once stress RAO is established, fatigue damage can be calculated very quickly. The regular wave method and the rain-flow counting method are more time consuming but give more exact results compare to spectral method. In case of regular wave method, a set of regular waves which represent random sea states is considered for dynamic analysis. The rain-flow counting method is the most intuitive and exact method because it refers time history stresses containing most of non-linear effects of the riser system. However, it is not common for early design stage to use rain-flow counting method because of its high cost. In this study, it was confirmed that the regular wave method is the most cost effective way in specific cases. However, if the system is highly non-linear, it seems that the regular wave method gives less accurate results than rain-flow counting method. Therefore, it is imperative that the engineers select appropriate analysis method based on design stage and given engineering period. This paper also discusses the theoretical background of each calculation method and hydrodynamic aspects of marine riser systems. A steel catenary riser (SCR) line on FPSO was considered and marine dynamic program (OrcaFlex) was used for static and dynamic analysis.

On the Implementation of an Advanced Judgement Algorithm for Contact Loss of Catenary System (전차선의 집전상태 판단 알고리즘 구현)

  • Park, Young;Jung, Ho-Sung;Yun, Il-Kwon;Kim, Wonha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.850-854
    • /
    • 2014
  • Analyzing dynamic performance between pantograph and contact wire depends on mechanical and electrical conditions such as contact force, currents, aerodynamics of pantograph and tension of overhead contact wire. For the characteristic of dynamic performance between pantograph and overhead contact wire, various evaluation systems are used to measuring of the interaction of the contact line and the pantograph. Among the various methods, the contact force and percentage of arcing are intended to prove the safety and the quality of the current collection system on the train. However, these methods are only capable of measuring on the train which are installed measurement systems. Therefore in this paper, a track-side monitoring system was implemented to measure electrical characteristics from active overhead contact wire systems in order to constantly estimate current collection performance of railway operation. In addition, a method to analyze loss of contact phenomena was proposed. According to simulation results, the proposed system was capable of measuring abnormal electrical behavior of pantograph and contact wires on the track-side. The advantage of the proposed system is possible to detect loss of contact or any other electrical abnormalities of all types of trains within sections from sub to sub without the need to install any on-board equipment on trains.