• 제목/요약/키워드: catenary action

검색결과 33건 처리시간 0.017초

Analysis of restrained steel beams subjected to heating and cooling Part I: Theory

  • Li, Guo-Qiang;Guo, Shi-Xiong
    • Steel and Composite Structures
    • /
    • 제8권1호
    • /
    • pp.1-18
    • /
    • 2008
  • Observations from experiments and real fire indicate that restrained steel beams have better fire-resistant capability than isolated beams. Due to the effects of restraints, a steel beam in fire condition can undergo very large deflections and the run away damage may be avoided. In addition, axial forces will be induced with temperature increasing and play an important role on the behaviour of the restrained beam. The factors influencing the behavior of a restrained beam subjected to fire include the stiffness of axial and rotational restraints, the load type on the beam and the distribution of temperature in the cross-section of the beam, etc. In this paper, a simplified model is proposed to analyze the performance of restrained steel beams in fire condition. Based on an assumption of the deflection curve of the beam, the axial force, together with the strain and stress distributions in the beam, can be determined. By integrating the stress, the combined moment and force in the cross-section of the beam can be obtained. Then, through substituting the moment and axial force into the equilibrium equation, the behavior of the restrained beam in fire condition can be worked out. Furthermore, for the safety evaluation and repair after a fire, the behaviour of restrained beams during cooling should be understood. For a restrained beam experiencing very high temperatures, the strength of the steel will recover when temperature decreases, but the contraction force, which is produced by thermal contraction, will aggravate the tensile stresses in the beam. In this paper, the behaviour of the restrained beam in cooling phase is analyzed, and the effect of the contraction force is discussed.

집중 이동하중을 받는 사장교의 휨 및 비틈 거동에 관한 연구 (A Study on the Bending and Torsional Behaviors of Cable-Stayed Bridges under a Concentrated Moving Load)

  • 장승필;임성순;주석범
    • 대한토목학회논문집
    • /
    • 제9권3호
    • /
    • pp.1-12
    • /
    • 1989
  • 사장교는 경간이 크기 때문에 발생하는 대변형 효과, 케이블의 현수 작용, 그리고 축력으로 인한 휨 강성 변화 등으로 비선형 거동이 나타난다. 사장교의 동적 거동은 구조물 안정성 검사를 위한 중요한 요소가 된다. 특히, 편재 이동하중이 작용하는 경우, 연직 변위와 비틂 변위는 복합될 뿐만 아니라 단면 좌우의 케이블 축력 변화도 중요한 동적 특성을 나타낸다. 본 연구에서는 편재 이동하중이 작용하는 사장교의 해석을 위한 이론적 연구와 유한 요소법을 제시하였고 이동 하중의 속도변화와 편심량의 크기에 따라 케이블의 장력과 절점 변위에 대한 동적 거동을 규명하였다. 본 연구에서 수행한 해석 결과에 따르면, 편재 이동 하중을 받는 사장교의 해석에서는 주형의 비틂과 이로 인한 케이블 축력 증가도 고려해야 할 것으로 사료된다.

  • PDF

Collapse Initiation and Mechanisms for a Generic Multi-storey Steel Frame Subjected to Uniform and Travelling Fires

  • Rackauskaite, Egle;Kotsovinos, Panagiotis;Lange, David;Rein, Guillermo
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.265-283
    • /
    • 2021
  • To ensure that fire induced collapse of a building is prevented it is important to understand the sequence of events that can lead to this event. In this paper, the initiation of collapse mechanisms of generic a multi-storey steel frame subjected to vertical and horizontal travelling fires are analysed computationally by tracking the formation of plastic hinges in the frame and generation of fire induced loads. Both uniform and travelling fires are considered. In total 58 different cases are analysed using finite element software LS-DYNA. For the frame examined with a simple and generic structural arrangement and higher applied fire protection to the columns, the results indicate that collapse mechanisms for singe floor and multiple floor fires can be each split into two main groups. For single floor fires (taking place in the upper floors of the frame (Group S1)), collapse is initiated by the pull-in of external columns when heated beams in end bays go into catenary action. For single floor fires occurring on the lower floors(Group S2), failure is initiated (i.e. ultimate strain of the material is exceeded) after the local beam collapse. Failure in both groups for single floor fires is governed by the generation of high loads due to restrained thermal expansion and the loss of material strength. For multiple floor fires with a low number of fire floors (1 to 3) - Group M1, failure is dominated by the loss of material strength and collapse is mainly initiated by the pull-in of external columns. For the cases with a larger number of fire floors (5 to 10) - Group M2, failure is dominated by thermal expansion and collapse is mainly initiated by swaying of the frame to the side of fire origin. The results show that for the investigated frame initiation of collapse mechanisms are affected by the fire type, the number of fire floors, and the location of the fire floor. The findings of this study could be of use to designers of buildings when developing fire protection strategies for steel framed buildings where the potential for a multifloor fire exists.