• 제목/요약/키워드: cast-in-concrete

검색결과 499건 처리시간 0.021초

Seismic behavior of simplified electrical cabinet model considering cast-in-place anchor in uncracked and cracked concretes

  • Bub-Gyu Jeon;Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Hong-Pyo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4252-4265
    • /
    • 2023
  • In the case of nuclear power plants near end of their design life, a reassessment of the performance of safetyrelated equipment may be necessary to determine whether to shut down or extend the operation of the power plant. Therefore, it is necessary to evaluate the level of performance decline due to degradation. Electrical cabinets, including MCC and switchgear, are representative safety-related equipment. Several studies have assessed the degradation and seismic performance of nuclear power plant equipment. Most of those researches are limited to individual components due to the size of safety-related equipment and test equipment. However, only a few studies assessed the degradation performance of electrical cabinets. The equipment of various nuclear power plants is anchored to concrete foundations, and crack in concrete foundations is one of the most representative of degradation that could be visually confirmed. However, it is difficult to find a study for analysis through testing the effect of cracks in concrete foundations on the response of electrical cabinet internal equipment fixed by anchors. In this study, using a simple cabinet model considering cast-in-place anchor in uncracked and cracked concretes, a tri-axial shaking table tests were performed and the seismic behavior were observed.

FRP 판과 현장타설 콘크리트 사이의 단순 부착모델 제안 (A Proposal of Simplified Bond Stress-Slip Model between FRP Plank and Cast-In-Place Concrete)

  • 유승운
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.65-72
    • /
    • 2008
  • 최근에 상용 FRP 판(plank)을 콘크리트 구조물의 영구 거푸집 및 보강재로 이용하기 위한 연구가 진행되고 있다. FRP 판과 타설 콘크리트가 합성효과를 발휘하기 위해서는 두 재료간의 부착이 중요한 요인 중의 하나이다. 이러한 부착을 확보하기 위하여 FRP 판에 모래를 일반적으로 건설현장에서 많이 사용하는 에폭시를 이용하여 부착하였다. FRP 판과 콘크리트 합성구조의 구조적 거동을 이해하기 위해서는 FRP판과 타설 콘크리트 사이의 정량적인 국부 부착모델이 필요하다. 본 연구에서는 이와 같은 합성구조 시스템에 간단히 적용할 수 있는 단순 부착모델을 제안한다.

Seismic performance assessment of the precast concrete buildings using FEMA P-695 methodology

  • Adibi, Mahdi;Talebkhah, Roozbeh
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.55-67
    • /
    • 2022
  • The precast reinforced concrete frame system is a method for industrialization of construction. However, the seismic performance factor of this structural system is not explicitly clarified in some existing building codes. In this paper, the seismic performance factor for the existing precast concrete building frame systems with cast-in-situ reinforced shear walls were evaluated. Nonlinear behavior of the precast beam-column joints and cast-in-situ reinforced shear walls were considered in the modeling of the structures. The ATC-19's coefficient method was used for calculating the seismic performance factor and the FEMA P-695's approach was adopted for evaluating the accuracy of the computed seismic performance factor. The results showed that the over-strength factor varies from 2 to 2.63 and the seismic performance factor (R factor) varies from 5.1 to 8.95 concerning the height of the structure. Also, it was proved that all of the examined buildings have adequate safety against the collapse at the MCE level of earthquake, so the validity of R factors was confirmed. The obtained incremental dynamic analysis (IDA) results indicated that the minimum adjusted collapse margin ratio (ACMR) of the precast buildings representing the seismic vulnerability of the structures approximately equaled to 2.7, and pass the requirements of FEMA P-695.

스터럽 보강 선설치 앵커의 정적 전단하중에 대한 저항 강도 (Static Shear Strength of Cast-in Anchors with Stirrup Reinforcement)

  • 박용명;조성훈;김태형;강충현;김재봉
    • 한국강구조학회 논문집
    • /
    • 제28권1호
    • /
    • pp.1-12
    • /
    • 2016
  • 본 연구에서는 스터럽 보강 선설치 앵커의 정적 전단하중에 대한 저항강도 평가를 위한 실험 연구를 수행하였다. 실험변수로는 전면지압철근 유무와 콘크리트 균열 유무로 설정하였다. 앵커는 M36, 연단거리는 180mm로 하였다. 모든 철근은 HD-10 철근을 사용하고 스터럽의 간격은 100mm로 하였다. 실험으로부터 전면지압철근을 설치한 경우 스터럽 저항강도는 16% 증가하였다. 한편 균열 콘크리트에서의 저항강도는 비균열 콘크리트에 비해 5% 감소에 불과하였다. 실험 결과로부터 ACI 318 및 ETAG 001 기준은 스터럽의 저항강도를 안전측으로 평가하였으며, 적절한 강도 평가 방안을 제안하였다. 마지막으로 스터럽 보강 시 앵커 본체의 파괴강도에 대한 고찰을 제시하였다.

PC 슬래브를 이용한 복합시스템 외부접합부의 반복하중에 대한 실험적 연구 (Experimental Study on External Joints of Hybrid System with PC Slab under Cyclic Loads)

  • 이현호;이주영;정하선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.487-492
    • /
    • 1998
  • The purpose of this study is to investigate the external joints flexural of hybrid system(RPC) which is consist of precast concrete slabs and cast in site concrete walls. The external joint's specimens were prepared by types of joint detail and were tested under cyclic load which used yielding displacement. The results of external joints of hybrid system showed that the strength capacity of RPC is little different than RC and that the energy dissipation capacity of RPC is similar to RC.

  • PDF

ACI 355.2에 의한 콘크리트 확장앵커의 유효계수(k값) 결정방법 (The Method for Determining the Effectiveness Factor(k value) of Concrete Expansion Anchors in accordance with ACI 355.2)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.151-152
    • /
    • 2020
  • Recently, concrete expansion anchors which are a type of post-installed mechanical anchors are widely used in reinforcement concrete structures. In order to be used in the reinforced concrete structures designed in accordance with ACI 318-19 or ACI 349-13, the structural performance tests of the concrete expansion anchors should be conducted in accordance with ACI 355.2. The effectiveness factor(k) of concrete expansion anchors should be determined through the reference tests and used for the design of anchorage to concrete according to ACI 318-19 or ACI 349-13. In this study, we will look into the method for determining the effectiveness factor(k) of concrete expansion anchors and anchorage design process of concrete expansion anchors by using the effectiveness factor(k) in accordance with ACI 349-19.

  • PDF

플라이애쉬를 혼입한 현장타설 매스콘크리트의 압축강도 추정에 관한 실험적 연구 (An Experimental Study on Prediction of Compressive Strength of the In situ Mass Concrete with Fly-ash)

  • 길배수;채영석;남재현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권1호
    • /
    • pp.163-169
    • /
    • 1999
  • The object of this study is to compare properties of massive fly-ash concrete with plain concrete. Two concrete mixtures comprising two batch each $1.0m^3$ in volume, were made from ready mixed concrete batch plant. The water-to-cementitious materials ratio was kept constant at 51.4%. Therefore, massive concrete specimen($W800{\times}D800{\times}H800mm$) was cast from ready mixed concrete to analyze history of temperature and core strength properties. Bleeding, time of slump loss and time of setting of the fresh concrete were measured. In order to estimate the properties of massive fly-ash concrete in hardened concrete, non-destructive tests such as rebound hardness, ultrasonic pulse velocity and maturity were performed and analyzed.

  • PDF

재료특성치의 변화로 인한 프리스트레스트 콘크리트 박스거더 교량의 거동분석 (A Study on the Behavior of Prestressed Concrete Box Girder Bridges According to material Properties)

  • 오병환;양인환;김의성;최인혁;김세훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.627-632
    • /
    • 1997
  • Recently, the prestressed concrete box girder bridges are increasingly built at various locations in the world. The mechanical and structural behavior of prestressed concrete brides varies because of time-dependent material properties and sequential change of structural system due to stepwise construction. The time-dependent behavior of concrete is of importance in the design and construction of segmentally constructed and cast-in-place prestressed concrete box girder bridges. The structural response is affected b variations in creep, shrinkage properties of concrete. In this study, the example of time-dependent deformations is extended to establish how the variability in concrete properties affects the accuracy of the calculated deformations in such a bridge, and finally the results are discussed.

  • PDF

설계강도 $40N/mm^2$ 매스콘크리트인 전이층보의 수화열 해석을 통한 온도 균열 제어에 관한 연구 (A Study on the Temperature Crack Control for Analysis of Hydration Heat of Mass Concrete Transfer Girder with Design Strength $40N/mm^2$)

  • 이종석;김주상;강연우;김재환;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.33-36
    • /
    • 2007
  • In order to select the optimum mix for the required fluidity and strength of mass concrete which is applied to transfer girder and to choose the optimum curing method depending on circumstances through hydration heat analysis of mass concrete, this study examined slump flow, air content and elapsed variation (0, 30, 60, 90) in unhardened concrete properties and reviewed compressive strength characteristics in hardening properties. And hydration heat analysis results through simulation are as follows; 1) Fluidity changes of unhardened concrete showed no significant difference, and those of elapsed variation also showed no difference but a bit of tendency to increase in comparison with the initial properties. 2) The higher the water-binder ratio was, the lower the compressive strength properties were, and the higher the fly ash replacement rate was, the lower the compressive strength development was. 3) In case of $Fc=40N/mm^2$, the optimum mix was fly ash replacement rate of 15% from water-binder ratio of 33.0%. 4) Hydration heat analysis results showed that in case of bundle cast, concrete temperature profile characteristics around transfer girder was unfavorable, and in case of separate cast, constant curing for at least seven days guaranteed thermal cracking index of 1.2.

  • PDF

기초와 기둥 통합구조물의 현장시험 및 거동 (Behavior of Integrated Column and Foundation by Field Load Tests)

  • 윤여원;김근수;민광홍;이영호;김대학
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1073-1076
    • /
    • 2010
  • Shallow foundations of various columns such as traffic signs, CCTVs, traffic lights, street lights, steel telephone poles and so on are made by cast-in-situ concrete method. However, typical cast-in-situ method has many problems because of the long duration of construction, occupation of sidewalks and low strength of the concrete after curing. In order to solve the problems, field load tests for the prefabricated DSF foundation made by combination of column and foundation was conducted to know load-deformation behavior by torsional tests.

  • PDF