• Title/Summary/Keyword: cardiac preservation

Search Result 52, Processing Time 0.024 seconds

Experimental Study of Isolated Canine Heart Preservation for 24 Hours at 4$^{\circ}C$ - A Portable Continuous Hypothermic Perfusion System - (적출심장의 장시간 [24시간] 보존에 관한 실험적 연구 -4$^{\circ}C$ 관류 보존법-)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.3
    • /
    • pp.425-446
    • /
    • 1988
  • After 24 hours of preservation under 15 mmHg perfusion pressure the recovery rates of isolated canine hearts were determined. Preservation was performed in a cold room maintained at 4*C with 4 different types of perfusates bubbled with a mixture of 95% 0y and 5% CO~ using a modified perfusion unit designed in our institute. The perfusates used were as follows; Group 1: Krebs-Henseleit solution, Group 2: Krebs solution added by albumin and PGE1. Group 3: Modified Wicomb*s solution, Group 4: Modified Collin*s solution. The extent of myocardial recovery was evaluated using a modified isolated carmine perfusion model by measuring heart rate, systolic arterial pressure, left atrial pressure[LAP] and cardiac output. In addition to the above hemodynamic parameters, biochemical and enzymatic assays from perfusates and electron microscopic changes of the myocardium were also studied. The results were as follows; 1] The heart recovery rates were 41.6%, 53.4% and 108.9% in groups 1, 2 and 3, respectively, and group 3 elicited the best result[p< 0.001]. The heart beat was never recovered in group 4. 2] Recovered systolic arterial pressures[mmHg] were 63.3% in group 1, 94.9% in group 2 and 94.3% in group 3. 3] LAPs[mmHg] were 20 in group 1, 13.5 in group 2 and 11.2 in group 3, which suggested that the best myocardial preservation was elicited in group 3[p< 0.05]. 4] Cardiac output, the sum of aortic stroke volume and coronary leakage, were 69.1% in group 2, and 90.7% in group 3, but these were not statistically significant[p=0.24]. No aortic stroke output was measured in group 1 and 4. 5] The degree of myocardial edema increase was 17.5` in group 1, 24.6% in group 2, 20.9% in group 3 and 55.3% in group 4. But there were no statistical differences in each group[p= 0.08]. 6] CPK-MB[U/L] levels were increased 750% and 332%[p< 0.05], glucose levels[mg/dl] 60.5% and 78.2% and SGOT[U/L] levels 523% and 333%, in groups 2 and 3, respectively. Biochemical and enzymatic assays could not be performed in group 1 and group 4, because of poor recovery of heart beat. 7] Electron microscopic findings in the myocardium of most groups revealed slight to moderate muscle cell and mitochondrial edema. But all these findings were within the limits of reversible change. From these above results, it is suggested that modified Wicomb*s solution seems to be the most useful physiologic salt solution for preservation of the heart. We propose that after further study and improvement, our portable continuous hypothermic perfusion system will contribute to the development of a better preservation method for donor hearts for human heart transplantation.

  • PDF

Isolated Working Canine Heart Perfusion Apparatus for Evaluation of Myocardial Protection Methods (심장기능 평가를 위한 견 적출심장 관류장치의 설계)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.246-253
    • /
    • 1988
  • An in vitro model providing with a recirculating perfusion apparatus using an isolated canine heart and its autogenous blood, which was prepared for study of myocardial protection method. This apparatus was easily used by quick connect system and maintained well heart function for about 2 hours. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at 37` into the aorta from aortic reservoir located 100 cm above the heart. The isolated perfused working canine heart model was a left heart preparation in which oxygenated perfusion medium [at 37K] entered the cannulated left atrium at a constant flow rate [900ml/ min] under 20 mmHg overflow system and was spontaneously ejected[no electrical pacing] via an cannula against a hydrostatic pressure of 80 cm H2O. During this working period, various indices of cardiac function were measured. The cardiac functions were stable for over 2 hours with perfusion of Krebs-Henseleit solution and autologous blood[1:1] mixture in volume and maintained heart rate ]]3-122/bpm peak systolic pressure 109-113 mmHg, cardiac output 900 ml / min and left atrial mean pressure 8-9 mmHg. In this model, the efficiency of myocardia] protection could be easily measured by means of functional, enzymatic, biochemical and ultrastructural assessment. And also, we believe this model to be a useful assessment screening model of recovery state after long duration of myocardial preservation of donor heart without difficult transplantation procedures.

  • PDF

Clinical Experiences of Multiple Organ Failure after Surgery for Acquired Cardiovascular Disease

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.275-284
    • /
    • 1990
  • A serious problem after cardiovascular surgery known as Multiple Organ Failure[MOF] whereby several vital organs successively demonstrate dysfunction in spite of intensive postoperative treatment has recently arisen. We have made a retrospective study of the clinical records of 137 patients who underwent cardiovascular surgery during past two years [1987-1988]. Fourteen patients [10%] developed multi-organ failure postoperatively with the results of seven death [50%]. In fatal group, preoperative poor cardiac function [Cardiac Index<2.0L/min/m2] was considered important prognostic factor and infection 5 disseminated intravascular coagulation complicating gastrointestinal bleeding were the leading cause of death. In conclusion, evaluation of multiple factors concerning multi-organ failure demonstrates preoperative poor functional preservation of vital organs is the main factor. So early diagnosis k management for each of the failing organs & prevention of infection are mandatory of the treatment of these critically ill patients.

  • PDF

Historical Perspectives of Korean Society for Thoracic and Cardiovascular Surgery: Inauguration and Activities of the Historical Records Preservation Committee

  • Park, Kook-Yang;Lee, Sungsoo;Chang, Byung-Chul;Oh, Tae Yun
    • Journal of Chest Surgery
    • /
    • v.52 no.4
    • /
    • pp.191-194
    • /
    • 2019
  • The Korean Society for Thoracic and Cardiovascular Surgery (KTCVS) was founded in 1968 and celebrated the 50th anniversary of its founding in 2018. The launch of the KTCVS may seem somewhat recent, given that the American Association for Thoracic Surgery was founded in 1917. However, considering the circumstances of the Korean medical community after the Japanese occupation (1910-1945), World War II (1940-1945), and the Korean War (1950-1953), this apparent delay is understandable. Even before the foundation of the KTCVS, the early pioneers of thoracic and cardiovascular surgery promptly adopted medical technologies from more advanced countries such as the United States, and contributed significantly to both cardiac and thoracic surgery despite difficult circumstances. In 2012, before the 50th anniversary of the founding of the KTCVS, members shared the opinion that objective records of the activities of the early pioneers should be identified and preserved, and reacted positively towards the necessity for historians who would preserve such records. With this background, the Historical Records Preservation Committee of the KTCVS (hereinafter, referred to as 'the Committee') was launched. The Committee published a white paper on the history of thoracic and cardiovascular surgery in 2015 and held an exhibition of the achievements of the pioneers at the 50th anniversary of the founding of the KTCVS. The Committee also published a book entitled "The history of Korean thoracic surgery with photographs: celebrating the 50th anniversary of the society." The Committee will keep making efforts to find and preserve materials related to activities during the early development of thoracic and cardiovascular surgery in Korea.

Investigation of right ventricle function in patients with tetralogy of Fallot after total correction using cardiac magnetic resonance imaging (심장 자기공명영상을 이용한 팔로사징 완전 교정술 후 우심실 기능에 대한 연구)

  • Jang, Woo Sung;Choi, Hee Joung;Lee, Jong-Min;Kim, Jae Bum;Kim, Jae Hyun;Jang, Jae Seok
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.238-241
    • /
    • 2017
  • Background: We investigated the difference in right ventricle (RV) volume and ejection fraction (EF) according to the pulmonary valve (PV) annular extension technique during Tetralogy of Fallot (TOF) total correction. Methods: We divided patients who underwent the procedure from 1993 to 2003 into two groups according to PV extension technique (group I: PV annular extension, group II: no PV annular extension) during TOF total correction. We then analyzed the three segmental (RV inlet, trabecular and outlet) and whole RV volume and EF by cardiac magnetic resonance imaging (MRI). Results: Fourteen patients were included in this study (group I: 10 patients, group II: four patients; male: nine patients, female: five patients). Cardiac MRI was conducted after a 16.1 years TOF total correction follow-up period. There was no statistical difference in RV segmental volume index or EF between groups (all p>0.05). Moreover, the total RV volume index and EF did not differ significantly between groups (all p>0.05). Conclusion: The RV volume and EF of the PV annular extension group did not differ from that of the PV annular extension group. Thus, PV annular preservation technique did not show the surgical advantage compared to PV annular extension technique in this study.

Is It Safe to Preserve Left Atrial Appendage During Maze Procedure?

  • Kyungsub Song;Woo Sung Jang;Namhee Park;Yun Seok Kim;Jae Bum Kim
    • Korean Circulation Journal
    • /
    • v.53 no.8
    • /
    • pp.566-577
    • /
    • 2023
  • Background and Objectives: The left atrial appendage (LAA) can contribute significantly to LA mechanical contraction. Nevertheless, the preventive effect of LAA occlusion during the maze procedure against cerebral infarction remains controversial. In this study, we compared the surgical, cardiac hemodynamic, and neurologic outcomes between LAA preservation and occlusion performed during the maze procedure. Methods: Between January 2015 and August 2021, 252 patients underwent the maze procedure using cryoablation at our medical center. After excluding patients according to our exclusion criteria (i.e., mechanical prosthesis implantation, preexisting LAA thrombus), LAA was preserved in 113 patients (non-occlusion group) and occluded in 75 patients (occlusion group). Outcomes were compared using propensity score matching (PSM). Results: PSM did not reveal significant intergroup differences in baseline characteristics between the non-occlusion (n=53) and occlusion (n=53) groups. During a median follow-up of 44 months, 2 patients in the non-occlusion group (3.8%) experienced ischemic strokes. There was no significant difference in the rate of freedom from stroke (p=0.19) and major adverse cardiac events (p=0.43) between the 2 groups. Through echocardiography at 1-year follow-up, a statistically significant difference in LA mechanical contraction was observed between the non-occlusion group and occlusion group (24 of 33 [72.7%] vs. 18 of 37 [48.6%], respectively; p=0.04). Conclusions: In this study, preservation of the LAA during the maze procedure resulted in better LA function than LAA occlusion, with similar rates of stroke.

Growth of Pulmonary Autograft in Swine, I.Feasibility of the Operation (신생돈을 이용한 이식 자가 폐동맥의 성장에 관한 연구, 제1보, 수술의 적합성)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.28 no.10
    • /
    • pp.885-891
    • /
    • 1995
  • In order to test the hypothesis that the pulmonic valve, when used to replace the aortic root as a pulmonary autograft, will remain a viable anatomical structure and will grow and develop normally along with the host, we performed aortic valve replacement with the pulmonary autograft in 15 neonatal piglets. The weight of the donor was 9.3 $\pm$ 0.2 kg, the recipient 9.6 $\pm$ 0.3 kg. Measured diameters of pulmonic annulus were 14 $\pm$ 0.2 mm for autograft and 14.2 $\pm$ 0.2 mm for pulmonary artery homograft. Operation was performed under cardiopulmonary bypass with deep hypothermia [20oC at low flow perfusion [70 ml/kg/min . The mean operation time was 227 $\pm$ 10 min., bypass time 152$\pm$ 7.6 min. and aortic cross clamp time 73$\pm$ 4.6 min.. 9 piglets survived more than 12 hours. One survived 12 days and died of pneumonia and the latest one survived in good condition and sacrificed at postoperative 6th week for cardiac catheterization and pathologic examination that revealed the viability and growing of the pulmonary autograft. Currently we are able to complete the operation with good preservation of cardiac function, and our postoperative care has evolved to the extent that we are now confident enough of having an acceptable percentage of long term survivors to undertake a definite study in this regard.

  • PDF

Comparative Study of Prolonged Preservation Methods in Rabbit Heart for Transplantation (이식을 위한 가토심장의 장기 보존방법에 관한 비교 연구)

  • Jo, Hyeong-Gon;Kim, Su-Hyeon;Kim, Song-Myeong
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • The successful cardiac transplantation depends partly on the donor heart preservation by a solution that will ensure recovery of myocardial function. The purpose of this study was to perform the evaluation of various preservation solutions and to accumulate the data on the requisites for ideal preservation solution. The experimental setup was the constant pressure Langendorffs perfusion system. Isolated rabbit hearts were perfused for 20minutes with unarm Krebs-Henseleit solution, stored for 4 hours in cold preservation solution after cardioplegia, and then were reperfused for 20minutes. The 4 experimental groups were prepared Hartmann's solution group (group 1, control), modified Euro-collins solution group(group II. MEC), modified University of Wisconsin group (group n, MUW), and CK solution(made by the author) group (group W, CK). The parameters for assessing the preservation ability were levels of enzymes in freezed myocardial tissues (lactate, creatine kinase-MB and adenosine deaminase), coronary flow. left ventricular developing pressure and dpldt. In conclusion, the ability of preservation for isolated rabbit heart was excellent in CK solution and modified University of Wisconsin solution, and poor in modified Euro-collins solution, compared with Hartmann solution. CK solution has low potassium concentrations(34.2mEq/L) and includes various substrates to be salutary on myocardial preservation. This fact may indicates the necessity of further refinements in selection or composition of electrolytes and substrates.

  • PDF

Experimental cardiac transplantation in the mongrel dogs (II) (한국산 잡견에서의 실험적 심장 이식술 (II))

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.23 no.5
    • /
    • pp.844-853
    • /
    • 1990
  • We have performed 27 cases of orthotopic homologous cardiac transplantation using Korean mongrel dogs and one case of sham operation for the evaluation of harmful effect of cardiopulmonary bypass itself on the dog from April, 1989 to June, 1990. Our previous reports have already demonstrated basal hemodynamic and hematologic data on the canine homologous heart transplantation and the fundamental principles of transplantation of the heart. The mean body weight of recipients was 13.2$\pm$1.2kg with a rage of 11 ~ 15kg, and the hemodynamic and hematologic pictures were almost same as the result of previous reports from our hospital, except marked decrease in postoperative platelet count[from 3.18 $\pm$0.80x106/mm3 to 1.41$\pm$0 37x 106/mm3]. Mean survival time was 24.82$\pm$49.40 hours with the longest survival of 264 hours. Donor cardiectomy included coronary vasodilatation with diltiazem, potassium arrest, and the rapid cooling of the heart suspending in the specially designed ice-bath. Median sternotomy provided excellent exposure of the surgical field. 6 \ulcorner0 prolene suture was used for the anastomosis of both atrial cuffs and the great arteries, and we found the fact that stenosis, bleeding, thrombus formation around the anastomotic site could be decreased with the use of everted horizontal mattress suture techniques. Immunosuppression was done with a combination of lower dose Cyclosporin-A, Azathioprine, methyl-prednisolone, but our cases still showed too short survival to worry about graft rejection. Still poor was our quality control of experimental animal, we had much difficulties in postmortem evaluation of the dogs. Low cardiac output due to biventricular failure, intractable supraventricular or ventricular tachyarrhythmia, postoperative massive bleeding, sepsis were most frequent findings that could be thought as a cause of death. A few cases showed subendocardial patch hemorrhage in both ventricular cavity or atrial septum at autopsy, suggesting acute subendocardial infarction. Although our team overcome most of the technical problems of orthotopic heart transplantation, we should pile up further knowledges about donor heart preservation, quality control of animal, infection, rejection, the effect of the cardiopulmonary bypass to improve the results.

  • PDF

Ex Vivo Lung Perfusion of Cardiac-death Donor Lung in Pigs

  • Paik, Hyo Chae;Haam, Seok Jin;Park, Moo Suk;Song, Joo Han
    • Korean Journal of Transplantation
    • /
    • v.28 no.3
    • /
    • pp.154-159
    • /
    • 2014
  • Background: Lung transplantation (LTx) is a life-saving treatment for patients with end-stage lung disease; however, the shortage of donor lungs has been a major limiting factor to increasing the number of LTx. Growing experience following LTx using donor lungs after cardiac death (DCD) has been promising, although concerns remain. The purpose of this study was to develop a DCD lung harvest model using an ex vivo lung perfusion (EVLP) system and to assess the function of presumably damaged lungs harvested from the DCD donor in pigs. Methods: The 40 kg pigs were randomly divided into the control group with no ischemic lung injury (n=5) and the study group (n=5), which had 1 hour of warm ischemic lung injury after cardiac arrest. Harvested lungs were placed in the EVLP circuit and oxygen capacities (OC), pulmonary vascular resistance (PVR), and peak airway pressure (PAP) were evaluated every hour for 4 hours. At the end of EVLP, specimens were excised for pathologic review and wet/dry ratio. Results: No statistically significant difference in OC (P=0.353), PVR (P=0.951), and PAP (P=0.651) was observed in both groups. Lung injury severity score (control group vs. study group: 0.700±0.303 vs. 0.870±0.130; P=0.230) and wet/dry ratio (control group vs. study group: 5.89±0.97 vs. 6.20±0.57; P=0.560) also showed no statistically significant difference between the groups. Conclusions: The function of DCD lungs assessed using EVLP showed no difference from that of control lungs without ischemic injury; therefore, utilization of DCD lungs can be a new option to decrease the number of deaths on the waiting list.