• 제목/요약/키워드: cardiac device

검색결과 133건 처리시간 0.024초

완전 이식형 인공심장의 심박출량 자동 제어 알고리즘 개발에 관한 연구 (Development of an Automatic Cardiac Output Control Algorithm for the Total Artificial Heart)

  • 최원우;김희찬;민병구
    • 전자공학회논문지B
    • /
    • 제32B권3호
    • /
    • pp.38-47
    • /
    • 1995
  • A new automatic cardiac output control algorithm for the motor-driven electromechanical total artificial heart(TAH) was developed based on the motor current waveform analysis without using any extra transducer. The basic control requirements of artificial heart can be described in terms of three features : preload sensitivity, afterload insensitivity, and balanced ventricular outputs. In the previous studies, many transducers were utilized to obtain informations of hemodynamic states for the automatic cardiac output control, But such automatic control systems with sensors have had reliability problems. We proposed a new sensorless automatic cardiac output control algorithm providing adequate cardiac output to the time-varying physiological demand without causing right atrial collapse, which is one of the critical problem in an active-filling type device. In-vitro tests were performed on a mock circulation system to evaluate the performance of the developed algorithm and the results show that the new algorithm satisfied the basic control requirements on the cardiac output response and the possibility of application of the developed algorithm to in vivo experiments.

  • PDF

심실의 부하감소 측면에서 좌심실 보조장치의 최적 치료시기 예측을 위한 시뮬레이션 연구 (Prediction of Pumping Efficacy of Left Ventricular Assist Device according to the Severity of Heart Failure: Simulation Study)

  • 김은혜;임기무
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.22-28
    • /
    • 2013
  • It is important to begin left ventricular assist device (LVAD) treatment at appropriate time for heart failure patients who expect cardiac recovery after the therapy. In order to predict the optimal timing of LVAD implantation, we predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used LVAD-implanted cardiovascular system model which consist of 8 Windkessel compartments for the simulation study. The time-varying compliance theory was used to simulate ventricular pumping function in the model. The ventricular systolic dysfunction was implemented by increasing the end-systolic ventricular compliance. Using the mathematical model, we predicted cardiac responses such as left ventricular peak pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous and pulsatile LVAD. Left ventricular peak pressure, which indicates the ventricular loading condition, decreased maximally at the 1st level heart-failure under pulsatile LVAD therapy and 2nd level heart-failure under continuous LVAD therapy. We conclude that optimal timing for pulsatile LVAD treatment is 1st level heart-failure and for continuous LVAD treatment is 2nd level heart-failure when considering LVAD treatment as "bridge to recovery".

The Accuracy of the Calculated Dose for a Cardiac Implantable Electronic Device

  • Sung, Jiwon;Son, Jaeman;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.150-154
    • /
    • 2019
  • The objective of this study is to monitor the radiation doses delivered to a cardiac implantable electronic device (CIED) by comparing the absorbed doses calculated by a commercial treatment planning system (TPS) to those measured by an in vivo dosimeter. Accurate monitoring of the radiation absorbed by a CIED during radiotherapy is necessary to prevent damage to the device. We conducted this study on three patients, who had the CIED inserted and were to be treated with radiotherapy. Treatment plans were generated using the Eclipse system, with a progressive resolution photon optimizer algorithm and the Acuros XB dose calculation algorithm. Measurements were performed on the patients using optically stimulated luminescence detectors placed on the skin, near the CIED. The results showed that the calculated doses from the TPS were up to 5 times lower than the measured doses. Therefore, it is recommended that in vivo dosimetry be conducted during radiotherapy for CIED patients to prevent damage to the CIED.

이중 박동성 인공심폐기(Twin-Pulse Life Support, T-PLS)를 이용한 심폐순환보조 (Extracorporeal Life Support with a Twin-pulse Life Support (T-PLS) System)

  • 이동협;이장훈;정태은
    • Journal of Chest Surgery
    • /
    • 제40권7호
    • /
    • pp.512-516
    • /
    • 2007
  • 기계적인 순환보조장치는 급성호흡부전이나 심부전에서 생명을 구할 수 있는 방편의 하나이다. 현재 여러 가지 형태의 순환 보조장치가 있으며 Twin-Pulse Life Support (T-PLS) system은 박동형 펌퍼의 한 종류다. 3예의 심한 심폐기능부전 상태 환자에게 순환보조장치로 T-PLS system을 사용하였다. 적응증은 인공호흡기와 강심제를 최대한 사용함에도 불구하고 지속되는 호흡부전이나 심부전이었다. 감염에 의한 호흡부전환자가 2예, 심근염에 의한 심부전 환자가 1예였다. 각각 한 명의 호흡부전환자와 신부전 환자가 생존하였는데 보조장치의 사용시간은 각각 3일과 5일이었다. T-PLS system은 순환보조장치로 유용하게 사용할 수 있으며 다발성 장기부전이 오기 전에 적용하여야 할 것으로 생각된다.

CARDIAC ASSIT DEVICE의 연구

  • 민병구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1979년도 하계 전자.전기연합학술발표회논문집
    • /
    • pp.147-149
    • /
    • 1979
  • PDF

Safe and Simplified Salvage Technique for Exposed Implantable Cardiac Electronic Devices under Local Anesthesia

  • Jung, Chang Young;Kim, Tae Gon;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.42-47
    • /
    • 2017
  • Background Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems, however, these may result in fatal complications. In this study, we present our experience with a simplified salvage technique for exposed implantable cardiac electronic devices (ICEDs) without removing the implanted device, in an attempt to reduce the risks and complication rates associated with this condition. Methods The records of 10 patients who experienced direct ICED exposure between January 2012 and December 2015 were retrospectively reviewed. The following surgical procedure was performed in all patients: removal of skin erosion and capsule, creation of a new pocket at least 1.0-1.5 cm inferior to its original position, migration of the ICED to the new pocket, and insertion of closed-suction drainage. Patients with gross local sepsis or septicemia were excluded from this study. Results Seven patients had cardiac pacemakers and the other 3 had implantable cardiac defibrillators. The time from primary ICED placement to exposure ranged from 0.3 to 151 months (mean, 29 months. Postoperative follow-up in this series ranged from 8 to 31 months (mean follow-up, 22 months). Among the 10 patients, none presented with any signs of overt infection or cutaneous lesions, except 1 patient with hematoma on postoperative day 5. The hematoma was successfully treated by surgical removal and repositioning of the closed-suction drainage. Conclusions Based on our experience, salvage of exposed ICEDs is possible without removing the device in selected patients.

무선 전자청진 심음을 이용한 심장질환 분류 (Cardiac Disorder Classification Using Heart Sounds Acquired by a Wireless Electronic Stethoscope)

  • 곽철;이윤경;권오욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.101-102
    • /
    • 2007
  • Heart diseases are critical and should be detected as soon as possible. A stethoscope is a simple device to find cardiac disorder but requires keen experiences in heart sounds. We evaluate a cardiac disorder classifier by using heart sounds recorded by a digital wireless stethoscope developed in this work. The classifier uses hidden Markov models with circular state transition to model the heart sounds. We train the classifier using two kinds of data: One recorded by using our stethoscope and the other sampled from a clean heart sound database. In classification experiments using 165 sound clips, the classifier shows the classification accuracy of 82% in classifying 6 cardiac disorder categories.

  • PDF

COR-KNOT-Induced Leaflet Perforation: How It Happens and How to Prevent It: A Case Report

  • Michael Salna;Jack Shanewise;Alex D'Angelo;Isaac George
    • Journal of Chest Surgery
    • /
    • 제57권1호
    • /
    • pp.96-98
    • /
    • 2024
  • The COR-KNOT suture fastening device has dramatically improved the efficiency of valve suture fixation. Despite its relative ease of use, there are important considerations in deployment to limit the risk of prosthetic valve injury. Herein, we report a case of iatrogenic aortic bioprosthetic insufficiency caused by poorly positioned COR-KNOTs and outline technical strategies to ensure success.

소아용 보조인공심장의 모의순환 실험에 관한 연구 (In Vitro Test of Seiong Pediatric Ventricular Assist Device)

  • 권혁남;박표원
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권1호
    • /
    • pp.29-34
    • /
    • 1991
  • Ventricular assist device(VAD) has been clinically applied as a temporary circulatory sup- porting system in the patients with severe heart failure, but small sized VAD for infant is not available. The purpose of tilis paper is to introdIAce small sized VAD and presents the result of in vitro test. Sejong VAD is diaphragmatic type of pneumatic pump and stroke volume is 11cc. Cardiac outputs of the Sejong VAD were measured by overflow tank under variable conditions of driving parameters. The cardiac output was 1.3 1/min at the heart rate of 120 per minute, left atrial pressure of $15cmH_2O$, percent systole of 43%, driving pressure of 240 mmHg, vacuum pressure of -40 mmHg, and mean aortic pressure of 70 mmHg. No mechanical problem was developed during the continuous in vitro test for 3 months.

  • PDF

이동통신망에서 심장질환 관리 시스템에 관한 연구 (A Study on Cardiac Disease Management System in Mobile Networks)

  • 한광록;손석원;장동욱
    • 한국컴퓨터정보학회논문지
    • /
    • 제14권1호
    • /
    • pp.163-171
    • /
    • 2009
  • 심장질환은 질병특성상 예방적인 처치가 무엇보다 중요하다. 그러나 현재 개발된 장치들은 환자가 통신장치를 이용하여 집 근처 100m 이내의 거리에서만 통신이 가능하고 환자가 이상을 느껴 스스로 버튼을 누르는 경우에만 서비스가 가능한 단점이 있다. 이러한 단점을 해결하기 위하여 본 연구에서는 상용 이동통신망을 이용하여 이상이 있는 ECG 신호를 자동으로 병원의 PC로 전송하는 심장질환 관리 시스템을 설계 및 구현한다. 개발된 시스템을 이용하여 실험한 결과 환자의 ECG 파형은 왜곡 없이 전송되어 데이터베이스에 저장됨을 확인하였다. 또한 SMS로 전송되는 데이터의 양을 64진법을 사용함으로써 16진법을 사용할 때보다 약 30% 이상을 줄일 수 있었다.