• Title/Summary/Keyword: cardiac compression

Search Result 70, Processing Time 0.021 seconds

Analysis of the Factors influencing the performance of Cardiopulmonary Resuscitation (심폐소생술 수행에 영향을 미치는 요인 분석)

  • Choi, Keun-Myung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.55-78
    • /
    • 2005
  • The purpose of this study was to provide basic data for the improvement of the guidelines and training programs regarding the cardiopulmonary resuscitation performance of bystanders who can respond to the incidents in earlier times as the first responder of the cardiac arrest incident, by reviewing the performance of basic CPR and the influencing factors after providing 70 students of Department of Emergency Medical Technology with the CPR training. For the purpose of the study, the collected data were computerized and analyzed by SPSS-WIN program(ver. 10.1). The results for this study were as follows The duration of session between the groups in the BLS CPR were 3 minutes and 36 seconds, 2 minutes and 32 seconds respectively. The average compression number per minute were 24.3 times and 33,2 times respectively(p=.000), and the average compression rate per minute were 112 times and 122 times respectively(p=.000). The average ventilation number per minute were 3.54 times and 5.1 times respectively(p=.000). The errors in compression "Too shallow" were 20.73 times(34.6%) and 23,23 times(38,7%) out of 60 times in 4 cycles with the standard of 38 nun. In CPR performance results according to gender in the first episode, males showed better results in compression depth as 41.5 mm comparing to females average 38.2 mm(p=.015). When ventilation results were compared according to the use of FS, the average ventilation number per minute, total ventilation per minute and the average volume per episode were significantly higher when FS was not used(<.040), There was no significant difference in ventilation accuracy between two groups. According to the results, we need to improve and distribute portable barrier devices, and to be familiar with those devices. We need to enforce ventilations as well as to include compressions so that faster and more accurate CPR can be performed. Additionally, we need to exclude ventilation only cases, minimize the interference time of chest compression due to inaccurate ventilation, simplify or minimize the complicatedness of CPR performance and responding time related to breathing, provide first responders with various training programs such as initial assessment and ventilations only, or initial assessment and chest compression-only CPR and than provide advanced training with AHA BLS education including CPR for more than two people according to CPR skills and target characteristics.

  • PDF

Effect of Mask Wearing and Type on Cardiopulmonary Resuscitation Accuracy, Fatigue and Physiological Changes

  • Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Hee-Jeong Ahn
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.113-120
    • /
    • 2023
  • The purpose of this study was the accuracy of cardiac compression, fatigue, and physiological changes of the rescuer for different mask type in cardiopulmonary resuscitation(CPR). Data collection was from 9 to 12 May 2022, the participants were a total of 24 paramedic students with a BLS provider at D University. The students participated in an experiment in which 12 students each wore a surgical mask (Dental mask) and a fine particle 94% blocking mask (KF94 mask) and performed CPR for 2 minutes over a total of 7 times. As a result of the study, in the analysis of the quality of the rescuer's chest compression according to the type of mask, there was a significant difference in the compression speed (F=24.91, p<.001) and bad compression hand position (F=14.54, p=.024) in the group wearing the KF94, Fatigue showed significant differences in both the Dental mask group (F=51.16, p<.001) and the KF94 mask group (F=63.49, p<.001). Among the physiological changes, heart rate showed a significant difference between the Dental mask group (F=34.79, p<.001) and the KF94 mask group (F=35.55, p<.001), and the respiratory rate showed a significant difference between the Dental mask group (F=25.02, p=.001) and the KF94 mask group(F=23.02, p=.002). Therefore, in order to improve the quality of efficient chest compression and reduce the fatigue and physiological changes of rescuers, it will be necessary for rescuers to wear suitable personal protective equipment.

Clinical Transcranial Doppler (임상 경두개 도플러 검사)

  • Kim, Jong-Soon;Ryoo, Jae-Kwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.4
    • /
    • pp.153-165
    • /
    • 1999
  • The transcranial Doppler(TCD) is a technique for measuring blood flow velocity of intracranial and extarcranial arteries. This examination based on Doppler effect which was first formulated in 1842 by the Austrian physicist Christian Doppler. In 1982, Rune Aaslid first maked 2MHz pulsed probe and recording intracranial vessels with transcranially. There are six criteria utilized in gaining positive identification of the intracranial vessels. The six criteria are as follows l)acoustical windows 2)depth of sample volume 3)direction of flow 4)spatial relationship of ACA and MCA bifurcation 5)mean velocity and 6)response common carotid artery compression and/or oscillation test. The affected factors for TCD examination are angle of insonation, posture of subject, age, gender, hematocrit, metabolic factors, and cardiac output. Clinical application of TCD are detection of stenosis, occlusion, emboli, thrombsis in intracranial and extracranial arteries and evaluation of cerebral arterovenous malformation, collateral capacity in the circle of Willis, ischemia cerebrovascular disease, stroke patient and vertebrobasilar system.

  • PDF

A Case Report of Rare Complications after Epicardial Permanent Pacemaker Implantation in an Infant: Airway Compression, Skin Necrosis, and Bowel Perforation

  • Kim, Woojung;Kwak, Jae Gun;Min, Jooncheol;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.82-85
    • /
    • 2020
  • Insertion of an epicardial pacemaker is a useful treatment for pediatric patients with an abnormal heart rhythm. However, there are limitations and concerns when implanting epicardial pacemakers in infants and neonates due to their small body size. We report a patient who experienced rare complications after implantation of a permanent pacemaker.

Knowledge and Attitude about Cardiopulmonary Resuscitation for Nursing Students (간호학생의 심폐소생술에 대한 지식 및 태도)

  • Ahn, Eun-Kyong;Cho, Mee-Kyung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.5-17
    • /
    • 2009
  • Purpose : This study was to examine the knowledge and attitude about cardiopulmonary resuscitation(CPR) for nursing students, and to basic data with CPR education program for nursing student. Method : 128 nursing students filled out a self-administered questionnaires. The data were collected by CPR knowledge and attitude modified by the authors based on Kim's inventory (2008). Result : Nursing students weren't knowledgeable nor confident of CPR. But they had positive attitude about as a first responder. Conclusion : Intensive education by the level of knowledge should be provided for nursing students to master the knowhow of CPR, especially cardiac compression, and evaluation should be reinforced as well. And an education should be offered to enhance their confidence CPR performing CPR.

  • PDF

Cardiac Decompressing Effect by Delayed Sternal Closure Following Open Heart Surgery in Children (소아에서 개심술후 정중흉골절개의 지연흉골폐쇄에 의한 심장압박 방지효과)

  • 김경환;서경필
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1167-1174
    • /
    • 1997
  • We retrospectively reviewed a series of 20 patients treated with delayed sternal closure during a 5-year period from 1991 to 1996. Of the 2675 patients with cardiovascular su gery 20 underwent this procedure. Male and female ratio was 11:9, mean age was 6.4 months(range 7 days to 5 years). The indications included unstable hemodynamic profiles after open heart surgery due to myocardial edema and poor lung compliance(15), necessity of mechanical ventricular assist device due to weaning failure(3), and hypoxia after PAB(2). Sternum was closed at a mean interval of 102(range 4 to 213) hours after operation. During delayed sternal closure, central venous pressure was elevated(p<0.05). Mediastinitis and other wound problems did not occur. Sepsis developed in 2 patients and microorganism was confirmed in one of the two patients. Five patients died(mortality 25%). And two of 15 discharged patients died during follow-up period. Cumulative survival rate was 65.0% at 12 months and also 65.0% at 24 months.(Standard error was 10.7%) Delayed sternal closure Is considered to be a good method to decompress the hemodynamically compromised heart. Without that, it is not f asible to come off bypass or to decompress the heart. Of course. careful selection of the indication is imperative.

  • PDF

A Study on the Cardiopulmonary Resuscitation Methods in Ambulance (구급차 내에서의 심폐소생술 방법에 관한 연구)

  • Shin, So-Yeon;Kim, Jee-Hee;Kim, Gyoung-Yong;Kang, Shin-Woo;Bang, Sung-Hwan;Yun, Jong-Geun;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.104-111
    • /
    • 2014
  • The purpose of this study is to investigate the CPR within ambulance. The Subjects were 890 emergency medical technicians in fire department in Gyeonggido. After continuing education program, the emergency medical technicians completed the questionnaires from January to February, 2012. Questionnaire consisted of demographic characteristics, method of chest compression (one handed or two handed), chest compression - ventilation ratio, and hands only CPR. Data were analyzed by frequency analysis and Chi-square test, t-test. One-way analysis of variance (ANOVA) was followed by Scheffe post-hoc test to analyze changes in all parameters between all groups. One handed chest compression accounted for 14.0% and two handed chest compression accounted for 86.0%. Hands only CPR accounted for 71.7% and standard CPR (30:2) accounted for 28.3%. In order to perform the high quality CPR, as least three persons must be dispatched in the ambulance. The flexible management of manpower may improve the survival from the cardiac arrest. A systemic approach for educating and training EMT's in CPR is needed.

Effects of chest compression only cardiopulmonary resuscitation training on retention of correct cardiopulmonary resuscitation knowledge (가슴압박 단독 심폐소생술 교육법이 일반 시민들의 심폐소생술 시행 지식 유지에 미치는 영향)

  • Choi, Seung Hyuk;Ryoo, Hyun Wook;Lee, Dong Eun;Moon, Sung Bae;Ahn, Jae Yun;Kim, Jong Kun;Park, Jung Bae;Seo, Kang Suk
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.568-577
    • /
    • 2018
  • Objective: Performing high quality cardiopulmonary resuscitation (CPR) is important for improving the survival rate with a good neurological outcome and fewer complications. The retention of accurate CPR knowledge is essential for providing high quality CPR. This study examined the effects of chest compression only CPR training on the retention of correct CPR knowledge. Methods: In December 2016, an interview survey to target the study population was conducted by trained interviewers, using a structured questionnaire. The respondents' general characteristics, status of CPR education, and knowledge and willingness regarding CPR were investigated. Pearson's chi-square tests and multivariate logistic regression analyses were used to determine which education-related factors affected the correct skill knowledge of performing CPR. Results: Among the respondents, there are 80 persons (17.4%) who answered correctly in the questions regarding the skills of performing CPR. The respondents who had a willingness to perform CPR to family and strangers were 90.2% and 44.9% respectively. Through multivariable analysis, the factors related to correct skill knowledge in performing CPR in the didactic with practice group were people who had undergone CPR training within 2 years (odds ratio [OR], 2.293; 95% confidence interval [CI], 1.311-4.009), and person who had undergone chest compression only CPR training (OR, 2.044; 95% CI, 1.033-4.042). Conclusion: Chest compression only type of CPR training and the experience of CPR education within 2 years were associated with accurate skill knowledge of performing CPR.

Design of CPR Artifact Removal Algorithm Based on Orthogonal Function using LMS Adaptive Filter (LMS 적응필터를 이용한 직교 함수 기반의CPR 잡음 제거 알고리즘 설계)

  • Lim, Eunho;Nam, Dong-Hoon;Myoung, Hyoun-seok;Kang, Dong-Won;Jeon, Dae-Keun;Yoon, Young-Ro;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.153-160
    • /
    • 2016
  • This study proposes an algorithm for removal of CPR artifact in order that automated external defibrillator (AED) can effectively diagnose ECG rhythm during cardiopulmonary resuscitation (CPR). Current AED required to interrupt chest compression for reliable rhythm analysis to avoid the effect of artifacts produced by CPR. However even temporarily interruption of chest compression during CPR adversely affects the probability of restoration of spontaneous circulation (ROSC) and survival after the delivery of the shock. Therefore, we proposed a method for removal of CPR artifacts using least mean square (LMS) filter. The removal of the CPR artifacts would enable compressions to continue during AED rhythm analysis, thereby increasing the likelihood of resuscitation success. It was tested on 31 segments of shockable and 300 segments of non-shockable ECG signals recorded from three pigs during CPR. In the result, sensitivity (Se) and specificity (Sp) analysis on the test segments showed values of Se = 3.2%, Sp = 66.0% and Se = 96.8%, Sp = 98.7% in the case of unfiltered and filtered signals during CPR. In conclusion, it was shown that the proposed method can be a useful tool to exactly diagnose the ECG rhythm during the CPR.

A Study on Educational CD-Title develop to Basic Life Support (기본인명구조술 교육용 CD-Title 개발 연구)

  • Lee, Jung-Eun;Koh, Bong-Yeun;Ahn, Kisoo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.33-45
    • /
    • 2004
  • The study is designed to develop an educational CD-Title for Basic Life Support. The study is conducted from July to December, 2002, Based on the course of program development suggested by Dick and Cray. the study followed the planning, development, education and evaluation of a program. The developed CD-Title consists of 8 parts. 1. Intro include Introduction, Adult CPR, Child CPR, Infant CPR, Adult Foreign-Body Airway Obstruction, Infant Foreign-Body Airway Obstruction, and Exercise in Menu at Right of screen. 2. Introduction consist of death process at cardiac arresst, chain of survival, introduction of CPR, respiratory & ciculatory anatomy and physiology. 3. Adult CPR consist of assessment responsiveness, activating EMS system, position victim, opening a airway, checking for breathing, rescue breathing, checking for sign of circulation, chest compression, 1 person & 2 persion adult CPR video. 4. Child & Infant CPR consist of, causes, assessment responsiveness, position victim, opening the airway, checking for breathing, rescue breathing, checking for sign of circulation, chest compression, activating EMS system, child & infant CPR video. 5. Adult Foreign-Body Airway Obstruction include assessment responsiveness, activating EMS system, position victim, opening a airway, checking for breathing, 2 rescue breathing, reopening the airway, 2 rescue breathing, finger sweep, 5 abdominal thrusts, unresponsiveness adult Foreign-Body Airway Obstruction video. 6. Infant Foreign-Body Airway Obstruction consist of, causes, assessment responsiveness, position victim, opening the airway, checking for breathing, 2 rescue breathing, reopening the airway, 2 rescue breathing, checking foreign-body object in oral cavity of victim, 5 back blow, 5 chest thsusts, activating EMS system, video. 7. 32 exercise consist of 8 Adult CPR, 12 Child & Infant CPR, 5 Adult Foreign-Body Airway Obstruction, 7 Infant Foreign-Body Airway Obstruction. Every part consist of animations to trigger students interests. This CD-Title will be useful education for first responders and lay rescuers.

  • PDF