• 제목/요약/키워드: carbon fiber reinforced plastics (CFRP)

검색결과 160건 처리시간 0.021초

초음파를 이용한 CFRP 복합재의 일방향 비파괴 평가 (One-Sided Nondestructive Evaluation of CFRP Composites By Using Ultrasonic Sound)

  • 임광희;장계림;최성록;예창희;류제성;임수환;한민규
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.47-52
    • /
    • 2011
  • It is well known that stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates because the layup of composite laminates influences their properties. Ultrasonic NDE of composite laminates is often based on the backwall echoes of the sample. A pair of such transducers was mounted in a holder in a nose-to-nose fashion to be used as a scanning probe on composites. Miniature potted angle beam transducers were used (Rayleigh waves in steel) on solid laminates of composites. Experiments were performed to understand the behavior of the transducers and the nature of the waves generated in the composite (mode, wave speed, angle of refraction). C-scan images of flaws and impact damage were then produced by combining the pitch-catch probe with a portable manual scanner known as the Generic Scanner ("GenScan"). The pitch-catch signal was found to be more sensitive than normal incidence backwall echo of longitudinal wave to fiber orientation of the CFRP composites, including low level porosity, ply waviness, and cracks. Therefore, it is found that the experimentally Rayleigh wave variation of pitch-catch ultrasonic signal was consistent with numerical results and one-side ultrasonic measurement might be very useful to detect the defects.

Low-velocity impact performance of the carbon/epoxy plates exposed to the cyclic temperature

  • Fathollah Taheri-Behrooz;Mahdi Torabi
    • Steel and Composite Structures
    • /
    • 제48권3호
    • /
    • pp.305-320
    • /
    • 2023
  • The mechanical properties of polymeric composites are degraded under elevated temperatures due to the effect of temperature on the mechanical behavior of the resin and resin fiber interfaces. In this study, the effect of temperature on the impact response of the carbon fiber reinforced plastics (CFRP) was investigated at low-velocity impact (LVI) using a drop-weight impact tester machine. All the composite plates were fabricated using a vacuum infusion process with a stacking sequence of [45/0_2/-45/90_2]s, and a thickness of 2.9 mm. A group of the specimens was exposed to an environment with a temperature cycling at the range of -30 ℃ to 65 ℃. In addition, three other groups of the specimens were aged at ambient (28 ℃), -30 ℃, and 65 ℃ for ten days. Then all the conditioned specimens were subjected to LVI at three energy levels of 10, 15, and 20 J. To assess the behavior of the damaged composite plates, the force-time, force-displacement, and energy-time diagrams were analyzed at all temperatures. Finally, radiography, optical microscopy, and scanning electron microscopy (SEM) were used to evaluate the effect of the temperature and damages at various impact levels. Based on the results, different energy levels have a similar effect on the LVI behavior of the samples at various temperatures. Delamination, matrix cracking, and fiber failure were the main damage modes. Compared to the samples tested at room temperature, the reduction of temperature to -30 ℃ enhanced the maximum impact force and flexural stiffness while decreasing the absorbed energy and the failure surface area. The temperature increasing to 65 ℃ increased the maximum impact force and flexural stiffness while decreasing the absorbed energy and the failure surface area. Applying 200 thermal cycles at the range of -30 ℃ to 65 ℃ led to the formation of fine cracks in the matrix while decreasing the absorbed energy. The maximum contact force is recorded under cyclic temperature as 5.95, 6.51 and 7.14 kN, under impact energy of 10, 15 and 20 J, respectively. As well as, the minimum contact force belongs to the room temperature condition and is reported as 3.93, 4.94 and 5.71 kN, under impact energy of 10, 15 and 20 J, respectively.

전자기 초음파를 이용한 CFRP 복합적층판의 적층배향 특성평가에 관한 연구 (A Study on Characterization for Stacking Fault Evaluation of CFRP Composite Laminates Using an EMAT Ultrasonics)

  • 임광희;나승우;김지훈;이창노;;양인영
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.83-92
    • /
    • 2005
  • An electromagnetic acoustic transducer (EMAT) is a unique probe that does not require a couplant or gel and also can usually generate or detect an ultrasonic wave into specimens across a small gap. It, therefore can be applied in a noncontact mode with a high degree of reproducibility. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. This shear wave for detecting the presence of the errors is very sensitive. A decomposition model has been used in the interpretation and prediction of test results. Test results have been com pared with model data. It is found that the high probability shows between tests and the model utilized in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform (2-D FFT).

마이크로웨이브 알곤 플라즈마를 이용한 고강도 탄소섬유 복합재용 직물 표면 처리 연구

  • 김소영;김성륜;노예지;이헌수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.289-289
    • /
    • 2013
  • CRFP (carbon fiber reinforced plastics)는 탄소섬유 직물에 수지를 함침시켜 만들어지며, 고강도, 고탄성을 지니면서도 가볍고 밀도가 낮기 때문에 항공우주, 스포츠 용품 등 다양한 분야에서 활용되고 있다. 탄소섬유와 수지의 결합력을 증가시키기 위해 사이징, $HNO_3$ 산화, 전기화학적 산화, 플라즈마 처리 등의 다양한 탄소섬유 표면처리 방법이 개발되고 있다. 본 연구에서는 복합재의 강도향상을 위해 탄소섬유 직물을 마이크로웨이브 알곤 플라즈마로 처리하여 강도변화를 관찰하였다. 플라즈마 처리된 직물은 열가소성수지인 CBT와 함침시켜 탄소섬유 복합재로 제조하였다. 그 결과 플라즈마 처리한 복합재의 강도 향상을 확인할 수 있었고, SEM(scanning electron microscope)을 통해 복합재의 표면이 거칠어진 것을 관찰할 수 있었다. 플라즈마로 인해 직물의 표면적이 증가하여 직물의 표면과 수지의 결합력이 증가한 것으로 판단된다.

  • PDF

경량화용 복합재 튜브의 적층구성이 흡수에너지 특성에 미치는 영향 (Influence of Stacking Sequence Conditions the Absorbed Energy Characteristics of Composite Tubes)

  • 김영남;김지훈;양인영
    • 한국정밀공학회지
    • /
    • 제18권11호
    • /
    • pp.34-41
    • /
    • 2001
  • This study is to investigate the energy absorption characteristics of CFRP(Carbon-Fiber Reinforced Plastics) tubes on static and dynamic tests. Axial static compression tests have been carried out using the static testing machine(Shin-gang buckling testing machine) and dynamic compression tests have been utilized using an vertical crushing testing machine. When such tubes are subjected to crushing loads, the response is complex and depends on the interaction between the different mechanisms that could control the crushing process. The collapse characteristics and energy absorption have been examined for various tubes. Energy absorption of the tubes are increased as changes in the lay-up which may increase the modulus of tubes. The results have been varied significantly as a function of ply orientation and interlaminar number.

  • PDF

모델 단순화에 의한 CFRP 복합 구조물의 유효 열전도율 추출 방법 연구 (STUDY ON A EFFECTIVE THERMAL CONDUCTIVITY OF THE CFRP COMPOSITE STRUCTURE BY A SIMPLIFIED MODEL)

  • 김동건;한국일;최준혁;이장준;김태국
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.63-69
    • /
    • 2015
  • The thermal balance test in vacuum chamber for satellite structures is an essential step in the process of satellite development. However, it is technically and economically difficult to fully replicate the space environment by using the vacuum chamber. To overcome these limitations, the thermal analysis through a computer simulation technique has been conducted. The CFRP composite material has attracted attention as satellite structures since it has advantages of excellent mechanical properties and light weight. However, the nonuniform nature of the thermal conductivity of the CFRP structure should be noted at the step of thermal analysis of the satellite. Two different approaches are studied for the thermal analyses; a detailed numerical modeling and a simplified model expressed by an effective thermal conductivity. In this paper, the effective thermal conductivities of the CFRP composite structures are extracted from the detailed numerical results to provide a practical thermal design data for the satellite fabricated with the CFRP composite structure. Calculation results of the surface temperature and the thermal conductivities along x, y, z directions show fairly good agreements between the detailed modeling and the simplified model for all the cases studied here.

Bond Strength of Carbon Fiber Sheet on Concrete Substrate Processed by Vacuum Assisted Resin Transfer Molding

  • Uddin, N.;Shohel, M.;Vaidya, U.K.;Serrano-Perez, J.C.
    • Advanced Composite Materials
    • /
    • 제17권3호
    • /
    • pp.277-299
    • /
    • 2008
  • High quality and expedient processing repair methods are necessary to enhance the service life of bridge structures. Deterioration of concrete can occur as a result of structural cracks, corrosion of reinforcement, and freeze.thaw cycles. Cost effective methods with potential for field implementation are necessary to address the issue of the vulnerability of bridge structures and how to repair them. Most infrastructure related applications of fiber-reinforced plastics (FRPs) use traditional hand lay-up technology. The hand lay-up is tedious, labor-intensive and relies upon personnel skill level. An alternative to traditional hand lay-up of FRP for infrastructure applications is Vacuum Assisted Resin Transfer Molding (VARTM). VARTM uses single sided molding technology to infuse resin over fabrics wrapping large structures, such as bridge girders and columns. There is no work currently available in understanding the interface developed, when VARTM processing is adopted to wrap fibers such as carbon and/or glass over concrete structures. This paper investigates the interface formed by carbon fiber processed on to a concrete surface using the VARTM technique. Various surface treatments, including sandblasting, were performed to study the pull-off tensile test to find a potential prepared surface. A single-lap shear test was used to study the bond strength of CFRP fabric/epoxy composite adhered to concrete. Carbon fiber wraps incorporating Sikadur HEX 103C and low viscosity epoxy resin Sikadur 300 were considered in VARTM processing of concrete specimens.

전자기 초음파를 이용한 CF/Epoxy 복합적층판의 적층결함 특성평가 (On Characterization for Stacking Fault Evaluation of CF/Epoxy Composite Laminates Using an EMAT Ultrasonics)

  • 임광희;나승우;;이창노;박제웅;심재기;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.254-257
    • /
    • 2004
  • An electromagnetic acoustic transducers (EMAT) can usually generate or detect an ultrasonic wave into specimens across a small gap. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates because the layup of composite laminates influences there properties. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. It was shown experimentally that this shear waves for detecting the presence of the errors is very sensitive. It is found that high probability shows between tests and the model developed in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform(2-D FFT).

  • PDF

CFRP 복합재료의 충격파괴거동에 관한 연구 (A Study on the Impact Fracture Behavior of Carbon Fiber Reinforced Plastics)

  • 고성위;김학돌;엄윤성;최영근;김형진;김재동;김엄기
    • 수산해양기술연구
    • /
    • 제38권4호
    • /
    • pp.300-306
    • /
    • 2002
  • 장섬유 CF/에폭시 복합재료를 사용하여-5$0^{\circ}C$에서 6$0^{\circ}C$ 사이의 범위에서 스팬길이를 변화시켜 충격시험으로 얻어진 임계파괴에너지의 거동을 고찰한 결과는 다음과 같다. 1. CF/에폭시 복합재료의 온도 변화에 따른 임계파괴에너지 GIC는 동일한 스팬길에서는 실온의 경우가 가장 높고, 6$0^{\circ}C$, -15$^{\circ}C$ 그리고 -5$0^{\circ}C$의 순으로 낮게 나타났다. 2. CF/에폭시 복합재료의 스팬길이의 변화에 대한 임계 파괴에너지 GIC는 동일한 온도조건하에서는 스팬길이가 20mm인 경우가 가장 높게 나타났으나 불안정하며, 스팬길이는 40mm인 경우 임계파괴에너지 GIC는 가장 낮게 나타났으나 실험치의 흩어짐을 고려할 때 40mm인 경우의 시험편이 더 적절한 조건이라 생각된다. 3. 본 실험에 사용한 재료의 파괴기구는 섬유의 풀아웃, 섬유와 매트릭스 사이의 디본딩 그리고 매트릭스의 변형을 관찰할 수 있었으며, 이와 같은 파괴기가구 종합적으로 상호작용한다고 생각된다.

구조용 폼의 조성 및 열 노화에 따른 변형특성 관찰 (Investigation of Properties of Structural Foam with Different Conformation and via Thermal Aging Condition)

  • 최진영;권일준;박성민;권동준
    • Composites Research
    • /
    • 제31권4호
    • /
    • pp.122-127
    • /
    • 2018
  • 섬유강화고분자복합재료(CFRP, Carbon Fiber Reinforced Plastics)의 경량화는 자동차 및 항공 분야에서 끊임없이 요구되고 있으며, 구조용 폼과 CFRP를 혼합하여 샌드위치 복합재료로 사용되고 있다. 본 연구에서는 열경화성 소재인 에폭시 폼과 폴리우레탄 폼 및 열가소성 소재인 PET 폼과 PVC 폼의 조성 차이에 따른 폼의 형상 및 열 노화를 통해 변화되는 기계적 특성 변화를 관찰하였다. 성형한 에폭시 폼, 폴리우레탄 폼 및 상용화된 PET 폼과 PVC폼을 180도에서 열 노화시켰으며, 30, 60, 120, 180분의 노화시간에 따라 구조용 폼의 변화를 광학 현미경 및 만능시험기로 폼 셀의 형상 및 압축강도를 평가하였다. 궁극적으로 에폭시 폼이 가장 높은 2.6 MPa의 압축강도를 가졌으며, 열 노화 조건에서도 물성저하나 형상의 변화가 거의 발생되지 않았다. 이는 에폭시 폼이 타 구조용 폼에 비해 열 노화 조건에서 후경화되어 강직한 조성을 이루며, 타 구조용 폼과는 다르게 내열 특성이 우수하기 때문에 고온용 구조용 폼으로 적용하기 적합한 소재임을 확인하였다.