• Title/Summary/Keyword: carbide

Search Result 1,943, Processing Time 0.029 seconds

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

A Study on the High Frequency Ultrasonic Attenuation Characterization in Artificially Aging Degraded 2.25Cr-1Mo Steel (2.25Cr-1Mo 강 인공 열화재의 고주파수 초음파 감쇠특성에 관한 연구)

  • Park, Ik-Keun;Park, Un-Su;Kim, Chung-Seok;Kim, Hyun-Mook;Kwun, Sook-In;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.439-445
    • /
    • 2001
  • The destructive method is reliable and widely used lot the estimation of material degradation but, it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. Ultrasonic nondestructive evaluation technique has been reported good to attain efficiency of measurement, high sensitivity of measurement, and rapidity and reliability of result interpretation. In this study, it was verified experimentally the feasibility of the evaluation of degraded 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $630^{\circ}C$ by high frequency longitudinal wave method investigating the change of attenuation coefficient by FFT analysis and wavelet transform. Because of carbide precipitation increase and spheroidization near grain boundary of microstructure to aging degradation, attenuation coefficient had a tendency to increase as degradation proceeded. It was identified possibly to evaluate degradation using the characteristics of high-frequency ultrasonics. Frequency dependence of ultrasonic attenuation coefficient to aging degradation appeared large, which made sure that attenuation coefficient is an important parameter for evaluation of aging degradation.

  • PDF

Surface Apatite Growth of NaOH and SBF Treated CP-Ti, Ti-6Al-4V and ECAP-Ti (NaOH처리와 SBF침적에 따른 CP-Ti, Ti-6Al-4V 및 ECAP-Ti의 표면 아파타이트 성장)

  • Oh Seok-Jin;Ruy Jae-Gyeoung;Lee Seung-Woo;Kim Yun-Jong;Han Man-So;Kim Chang-Hyu
    • Korean Journal of Materials Research
    • /
    • v.14 no.12
    • /
    • pp.893-899
    • /
    • 2004
  • Even though Ti-6Al-4V has gained popularity as an implant material, the possible dissolution of Al and V ions in body fluids remains a matter of concern. Though commercially pure Ti (Cp-Ti) overcomes this problem, the mechanical strength of pure titanium remains very low. Thus, in this experiment Cp-Ti was processed by Equal channel angular processing (ECAP), in order to increase the mechanical strength. The biocompatibility of ECAP-Ti, Cp-Ti and Ti-6Al-4V was examined by the apatite formation on each sample surface, after treating the surface with 5M NaOH and soaking in Simulated body fluids (SBF). Initially, the samples were mechanically polished on silicone carbide paper (#2000). The polished samples were treated with 5M NaOH solution at $60^{\circ}C$ for 24 hours. The NaOH treated samples were washed gently with distill water and dried at $40^{\circ}C$ for 1 day. The dried samples were heat treated in air at $600^{\circ}C$ for 1 hour. The surface morphology of these samples were studied using SEM and XRD. The SEM studies showed network of pores in all samples. The XRD showed oxide layer formation on Cp-Ti and Ti-6Al-4V. samples. However the oxide layer in ECAP-Ti was not substantial. These samples were immersed in SBF, kept at $36.5^{\circ}C$ for seven days period. At the end of 7 days, the apatite formation was confirmed only on Cp-Ti and was not observed in Ti-6Al-4V and ECAP-Ti. These observations of apatite formation relate to the fact that Cp-Ti showed greater oxide layer than other samples. The apatite examined was confirmed as tricalcium phosphate (TCP) using EDS and XRD.

Measurement of the Phase Fraction of Minor Precipitates in Ni Base Superalloys using Quantitative X-ray Diffraction Technique (정량 x-선 회절분석법을 이용한 니켈기 초내열합급내 미량석출물의 상분율 측정)

  • Kim, S.E.;Cho, C.C.;Hur, B.Y.;Na, Y.S.;Park, N.K.
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.235-242
    • /
    • 1999
  • It is impossible to measure the fraction of the precipitates which are neither plenty nor distiguishable on micrographs, using point counting method or image analyzer. In this study, phase fraction of sigma, carbide and boride which are important to mechanical properties of Ni base superalloy Udimet 720 has been measured using a quantitative X-ray diffraction technique combined with electrochemical extraction. The alloys had been exposed at $800^{\circ}C$ for various times up to 3000 hours to have a variation of the amount of the minor precipitates. The amount of sigma had increased exponentially with increasing exposure time up to 3000 hours before saturation. It can be argued that the finishing point of precipitation is around 5000 hours and maximum amount of sigma to be produced is about 5% in weight. The amounts of $M_{23}C_6$ and $M_3B_2$ were maintained constant at the level of 0.1~0.5% in weight, regardless of exposure time.

  • PDF

AN ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS IN THE SALINE SOLUTIONS WITH FLUORIDE COMPOUNDS (불소화합물을 첨가한 생리식염수에서 아말감의 부식거동에 관한 전기화학적 연구)

  • Yun, Chong-Hun;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.396-412
    • /
    • 1997
  • The purpose of this study is to observe the corrosion characteristics of five dental amalgams(CAULK FINE CUT, OPTALLOY II, DISPERSALLOY, TYTIN, and VALIANT) in the solutions with fluoride compound through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydraulic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. Specimens were polished with the silicone carbide grinding paper 24 hours after condensation and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgams in 0.9 % saline solution and in the saline solutions with 2.2 ppm, 0.05 %, 2 % NaF, and 8 % $SnF_2$ at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 30 minutes, the potential scan was begun. The potential scan range was -1500m V to + 800m V(vs. S.C.E.) in the working electrode and the scan rate was 50 mV/sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the saline solutions with NaF shifted to lower direction than those in normal saline solution, and the current density in the saline solutions with NaF was higher than that in normal saline solution. The differences were increased as the concentrations of NaF became higher. 2. The corrosion potential and transpassive potential in the saline solution with $SnF_2$ shifted to higher direction than those in normal saline solution, and the current density in the saline solution with $SnF_2$ was higher than that in normal saline solution after the corrosion potential. The anodic polarization curves in the saline solution with $SnF_2$ had no outstanding anodic current peak. 3. The corrosion potentials for high-copper amalgams were much higher than those for CAULK FINE CUT and OPTALLOY II in normal saline solution, but, as the concentrations of fluoride compound became higher, the differences in corrosion potentials between them were decreased. The corrosion potentials had the similarity in the saline solution with 2% NaF or 8% $SnF_2$. 4. The current density for TYTIN was the lowest among the others in normal saline solution and in the saline solution with 2.2 ppm or 0.05 % NaF. 5. There was no significant difference in current density between Pd-enriched VALIANT and other high-copper amalgams.

  • PDF

Identifying Characteristics of Incidents at Hazardous Material Facilities

  • Kim, Geun-Young;Kim, Sang-Won;Won, Jai-Mu
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.51-56
    • /
    • 2009
  • Safety and quality assessment systems are very important in manufacture, storage, transportation, and handling of hazardous materials(hazmat) to prevent hazmat disasters. At present, hazardous materials exist everywhere in our daily lives with various forms of plastics, household products of cleaning and washing detergents, fertilizers or petroleum-related products. However, hazardous materials are dangerous substances when they are released to human or environment. Hazardous materials become very widely used substances in the age of oil-based industrial economy. The Korean Ministry of Environment (KMOE) describes about one hundred thousand types of chemicals are produced and used worldwide. Over four hundred new chemicals are introduced in every year. A crucial question for the Korean hazardous material management may have been raised: Will you be safe from hazardous material incidents? The gas leak disaster at Union Carbide's Bhopal, India in 1984 that made over 6,400 people killed and 30,000 to 40,000 people seriously injured is the representative case for the safety of hazmat. Korea becomes vulnerable to hazmat disaster due to the development of high-tech industry. Thus, the risk assessment system is required to Korea for transferring abandoned hazmat management systems to self-correcting safety systems. This research analyzed characteristics of various hazmat incidents applying statistical analysis methods including frequency analysis or analysis of category data to hazmat incidents for ten years. All of three analyses of category data indicate the significance of causality between hazmat incident site groups and seasons, regional groups, and incident casualty groups.

Fabrication and Characteristics of Resin-Type Neutron Shielding Materials for Spent Fuel Shipping Cask (사용후핵연료 수송용기에 사용될 수지계 중성자 차폐재 제조 및 특성)

  • Cho, Soo-Haeng;Do, Jae-Bum;Ro, Seung-Gy;Do, Chun-Ho
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.597-604
    • /
    • 1996
  • Resin-type neutron shielding materials, KNS-115A, 115B and 115C have been fabricated to be used for spent fuel shipping cask. The base material is epoxy resin, and polypropylene, aluminium hydroxide and boron carbide are added. These shielding materials offer good fluidity at processing, which makes it possible to apply this resin shield to complicated geometric shapes such as shipping cask. Several measurements were made for the shielding materials to evaluate the shielding property, combustion characteristics, fire resistance, thermal and mechanical properties. The neutron shielding ability of the shielding materials is estimated to be better than that of foreign's shielding material, NS-4-FR, due to higher hydrogen atomic density. Other properties of the shielding materials are as follows: Onset temperatures; $267{\sim}270^{\circ}C$, thermal conductivities; $0.62{\sim}0.72W/m{\cdot}K$, combustion characteristics; <$800^{\circ}C$, ATB(average time of burning); <5sec, AEB(average extent of burning) ; <5mm, tensile strengths; $2.3{\sim}3.0kg/mm^2$, compressive strengths; $5.3{\sim}13.3kg/mm^2$, flexural strengths; $4.4{\sim}5.4kg/mm^2$.

  • PDF

Thermal Deactivation of Plate-type V2O5-WO3/TiO2 SCR Catalyst (Plate-type V2O5-WO3/TiO2 SCR 촉매의 열적 비활성화 특성)

  • Cha, Jin-Sun;Park, Jin-Woo;Jeong, Bora;Kim, Hong-Dae;Park, Sam-Sik;Shin, Min-Chul
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.576-580
    • /
    • 2017
  • In the present paper, the thermal deactivation characteristics of plate-type commercial $V_2O_5-WO_3/TiO_2$ SCR catalyst were investigated. For this purpose, the plate-type catalyst was calcined at different temperatures ranging from $500^{\circ}C$ to $800^{\circ}C$ for 3 hours. Structural and morphological changes were characterized byXRD, specific surface area, porosity, SEM-EDS and also NOx conversion with ammonia according to the calcine temperature. The NOx conversion decreased with increasing calcine temperature, especially when the catalysts were calcined at temperatures above $700^{\circ}C$. This is because the crystal phase of $TiO_2$ changed from anatase to rutile, and the $TiO_2$ grain growth and $CaWO_4$ crystal phase were formed, which reduced the specific surface area and pore volume. In addition, $V_2O_5$, which is a catalytically active material, was sublimated or vaporized over $700^{\circ}C$, and a metal mesh used as a support of the catalyst occurred intergranular corrosion and oxidation due to the formation of Cr carbide.

耐 마모 코우팅 생산을 위한 CVD와 PVD 기술

  • O, Seung-Tak
    • Journal of the Korean institute of surface engineering
    • /
    • v.20 no.1
    • /
    • pp.15-24
    • /
    • 1987
  • 超硬合金과 高速度鋼에 TiC, TiN 그리고 $Al_2O_3$의 耐 마모 코우팅시에 사용되는 CVD와 PVD 기술을 M E Sjostrand와 A G Thelin 등이 본 논문에서 논의하였다. 또한 CVD와 PVD 의 특별한 장점과 응용영역에 대하여도 토의하였다. 수년동안 CVD 기술은 금속질화물, 금속탄화물 그리고 금속산화물 등의 耐 마모 코우팅을 생산하는데 성공적으로 사용되어 왔다. Munster와 Ruppert에서는 1950년대 초기에 TiC와 TiN의 CVD 공정을 연구했는데 이런 코우팅 재료의 높은 화학적 안정성과 더불어 高硬鋼라는 독특한 성질로 인해 그 주요 영역이 명백해졌다. 1968년에 처음으로 CVD법에 의한 보호막 코우팅의 대규모 응용이 이루어졌는데 그것은 超硬合金 절삭공구의 코우팅이었다. (그림1 참고) 이것은 硬금속산업에 있어서 가장 중요한 발전단계였다. TiC, TiN 그리고 $Al_2O_3$로 코우팅된 공구의 생산은 1970년대에 빠른 성장을 보였으며 오늘날 사용되는 절삭날의 50% 이상을 점유하고 있다. (그림2 참고) TiC와 TiN은 현재 이용되고 있는 모든 耐 마모 코우팅 중에서 독보적인 위치를 차지하고 있다. 그 이유는 생산과정이 비교적 단순하기 때문이다. 지난 5년동안 절삭공구와 總形바이트의 코우팅에 대한 PVD기술의 응용이 폭발적으로 증가했다. 증착기술인 이들 CVD와 PVD 각각은 자체의 독특한 장점이 있으므로 그 응용영역은 증착조건, 즉 기지금속의 접착성과 증착온도 그리고 증착속도등에 따라 매우 다를 것이다. PVD 공정으로 인해 고속도 공구강이 급속도로 발전되었고 더우기 PVD공정은 500$^{\circ}C$ 이하의 증착온도에서 brazed carbide 공구의 코우팅을 가능하게 하였다. 따라서 두 증착기술은 서로 상반적이라기 보다는 상호보완적인 것이라고 생각하는 편이 더 좋다.TEMPLA에 비해 CLB의 수가 15.58% 감소되었다. 높은 활성을 나타내었다. 정제된 효소의 최적온도는 40$^{\circ}C$이었으며 20~50$^{\circ}C$에서 비슷한 활성을 나타내었고, 30$^{\circ}C$에서는 60분동안 효소활성이 거의 상실되지 않았다. 정제된 효소는 ethanol과 chloroform 처리에는 안정하였으나 12mM AT 와 0.1mM $NaN_3$ 및 1mM KCN에 의해 90% 이상의 활성이 억제되었다.이에 근거하여 서울시 학생들($7{\sim}18$세)의 만성신부전증 유병률은 1백만명당 5.7명으로 추정되었다. 결론 : 서울시내 학생들 중 11세, 14세, 17세 3개 군에서 한 번 검사로 확인된 무증상 단백뇨의 유병률은 0.28%(약 2.8명/1,000명)이었고 이들중 약 5%만이 3차검사에서 신질환이 의심되었으며 이에 따른 신질환 유병률은 1만명당 1.4명이었다. $7{\sim}18$세 연령층에서 무증상으로 발생하는 사구체 신질환 중에는 IgA 신병증의 유병률이 가장 높아 1만명당 0.64명으로 추정되었고 만성신부전증의 유병률은 1백만명당 5.7명으로 추정되었다. 집단뇨 검사를 통해 확인되는 신질환은 대부분 사구체 질환이기 때문에 집단뇨검사의 의의는 좀더 연구가 필요할 것으로 생각되었다. 오히려 증상을 동반하는 경우보다 빈도가 증가한다는 사실은 집단뇨 검사에서 소변의 이상소견이 발견되어 신장 조직검사를 실시할 경우 혈청 $C_3$치의 감소 여부에 관계없이 MPGN도 진단적 고려 대상이 되어야 한다고 생각한다.신장 조직검사를 시행한 결과 진행성 경과를 취할 수 있는 막 증식성 사구체 신염과 매우 희귀한 증례인 신유전분증 등으로 진단됨으로써 지속성 단백뇨의 경우 정확 진단적 접근이 필수적임을 알 수 있다. 기립성

  • PDF

Evaluation of the feasibility of bony window repositioning without using a barrier membrane in sinus lateral approach (상악동측방접근법시 차폐막을 사용하지 않는 골창재위치술의 유용성 평가)

  • Jeon, Seung-Hwan;Cho, Yong-Seok;Lee, Byung-Ha;Im, Tae-Yun;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.122-126
    • /
    • 2011
  • Introduction: In the lateral window approach for a maxillary sinus bone graft, there has been considerable controversy regarding the placement of a barrier membrane over the osteotomy site. In particular, when there is no damage to the Schneiderian membrane, clinicians should decide whether to use a barrier membrane or not, considering the benefits and costs. This study presents the clinical cases to demonstrate that only repositioning the detached window can lead to satisfactory bony healing of the grafted material without using a barrier membrane in the lateral approach for a maxillary sinus bone graft. Materials and Methods: Five consecutive patients were treated with the same surgical procedures. After performing the antrostomy on the lateral maxillary wall using a round carbide bur and diamond bur, the bony window was detached by a gentle levering action. After confirming no perforation of the Schneiderian membrane, the grafting procedure was carried out the detached window of the lateral maxillary wall was repositioned over the grafted material without using a barrier membrane. A gross examination was carried out at the postoperative 6 month re-entry, and the the preoperative and postoperative dental computed tomography (CT) at re-entry were compared. Results: All the procedures in the 5 patients went on to uneventful healing with no complications associated with the bone graft. Satisfactory bone regeneration without the interference of fibrous tissue on the gap between the repositioned window and lateral wall of the maxillary sinus was observed in the postoperative 6 month re-entry. The CT findings at re-entry revealed the, reconstruction of the external cortical plate including repositioned bony window. In addition, the loss of the discontinuity of the lateral maxillary wall was confirmed. Conclusion: This preliminary report showed that the detached window, which was just repositioned on the grafted material, could function as a barrier membrane in the lateral approach for a maxillary sinus bone graft. Therefore additional morphometric and histologic studies will be needed.