• Title/Summary/Keyword: capacity prediction

Search Result 860, Processing Time 0.024 seconds

Performance Prediction of Main Coolant Pump in Integral Reactor SMART (일체형원자로 SMART 냉각재순환펌프의 성능예측)

  • Kim Min-Hwan;Park Jin-Seok;Kim Jong-In
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.118-125
    • /
    • 2001
  • The performance prediction of SMART MCP was performed using a computational fluid dynamics code. General capacity-head performance curve of MCP, which is provided to other design branches as design input, was obtained and it showed the typical type of axial pump performance curve. When four MCPs operate in parallel and one of them stops while the others continue to operate, SMART requires reduced power operation. A procedure for predicting the performance of SMART MCP for that case was developed and verified with available experimental data. An analysis based on the developed procedure was performed for two cases; the impeller of sloped MCP is fixed or free to rotate in reverse direction. According to the results, $73\%$ flow rate of normal operation enters the reactor core in the case of the locked impeller. In case of the impeller free rotation, the flow rate entering the reactor core is $62.8\%$.

  • PDF

Development of Low Noise Intake System using Taguchi Method (다구찌법을 이용한 자동차 흡기계의 저소음화에 대한 연구)

  • 오재응;조용구;이규태
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.234-240
    • /
    • 2001
  • Recently, the regulations from the government and the concerns of people be raised to the interest in exhaust and intake noise of passenger car as much as other vehicles. In these demands, performance prediction software was developed in this paper. In this study, Robust design was used for improving the noise reduction capacity of intake system with the performance prediction software. On the basis of the existing design, length and radius of each component that was thought to be effective to the performance of intake system was selected. At first, factors are arranged by using Ll8 table of orthogonal array and then optimum value can be obtained by modified Ll6 table of orthogonal array.

  • PDF

Investigation of the seismic performance of precast segmental tall bridge columns

  • Bu, Z.Y.;Ding, Y.;Chen, J.;Li, Y.S.
    • Structural Engineering and Mechanics
    • /
    • v.43 no.3
    • /
    • pp.287-309
    • /
    • 2012
  • Precast segmental bridge columns (PSBC) are alternatives for monolithic cast-in-situ concrete columns in bridge substructures, with fast construction speed and structural durability. The analytical tool for common use is demonstrated applicable for seismic performance prediction of PSBCs through experiment conducted earlier. Then the analytical program was used for parameter optimization of PSBC configurations under reversal cyclic loading. Shear strength by pushover analysis was compared with theoretical prediction. Moreover, seismic response of PSBC with energy dissipation (ED) bars was compared with its no ED bar counterpart under three history ground acceleration records. The investigation shows that appropriate ED bar and post-tensioned tendon arrangement is important for higher lateral bearing capacity and good ductility performance of PSBCs.

Estimating of Soil Loss from Hillslope Using WEPP Model (WEPP 모형을 이용한 경사지 토양유실량 추정)

  • Son, Jung-Ho;Park, Seung-Woo;Kang, Min-Goo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.45-50
    • /
    • 2001
  • The purpose of this study was to estimate of soil loss form hillslope using WEPP(Water Erosion Prediction Project) model. WEPP model was developed for predicting soil erosion and deposition, fundamentally based on soil erosion prediction technology. The model for predicting sediment yields from single storms was applied to a tested watershed. Surface runoff is calculated by kinematic wave equation and infiltration is based on the Green and Ampt equation. Governing equations for sediment continuity, detachment, deposition, shear stress in rills, and transport capacity are presented. Tested watershed has an area of 0.6ha, where the runoff and sediment data were collected. The relative error between predicted and measured runoff was $-16.6{\sim}2.2%$, peak runoff was $-15.6{\sim}2.2%$ and soil loss was $-23.9{\sim}356.5%$.

  • PDF

A Study on the Prediction of the Soil Thermal Property Using Predicting the Soil Moisture Contents (수분함량예측기법을 이용한 토양 열특성 예측에 관한 연구)

  • Jeong, S.H.;Kim, D.K.;Choi, S.B.;Bae, J.H.;Ha, T.H.;Lee, H.G.;Cho, S.B.;Kang, J.W.;Kwag, B.M.;Yoon, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.576-578
    • /
    • 2000
  • This paper address the prediction method of a soil thermal property depending on soil moisture contents and suggests the guideline to determine the soil thermal resistivity for the calculation of the cuurent carrying capacity of underground power cables in Korea.

  • PDF

Prediction of the Fatigue Life of Deep Groove Ball Bearing under Radial and Moment Loads -Equivalent Dynamic Loads- (반경방향과 모멘트하중 하에서의 깊은홈 볼베어링의 피로수명 평가 -동등가하중식 제안-)

  • 김완두;한동철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1654-1663
    • /
    • 1994
  • Even if the ball bearing was conservatively designed considering the dynamic capacity and the rating life, sometimes the bearing was early failed on account of the misalignment and the lubricant contaminations etc. Misalignment was generated when bearing-shaft system transmitted large power and when the bearing was inadequately mounted. It was possible to predict the fatigue life of ball bearing under the misalignment considering the motions of ball, cage and raceway, and the factors of the effect on fatigue life. Misalignment affected on ball bearing as radial and moment load and the relationships between misalignment and moment were obtained. In this paper, the analysis of the load distributions between ball and raceway, and the prediction of fatigue life of deep groove ball bearing under radial and moment loads were carried out. And, the new formulation of equivalent dynamic load considering the effects of moment load was proposed.

Energy Regression Analysis for Economic Evaluation of Cooling Plants (냉방열원의 경제성 평가를 위한 건물에너지 회귀식 산출)

  • 김영섭;김강수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.377-384
    • /
    • 2002
  • For economic evaluation of cooling plant equipments, it is necessary to simplify energy Prediction method, which should includes efficiency corrected by part-load ratio. This study proposed simplified method with regression equations of time-average partial loads and refrigerator capacity. DOE-2 Program was used to carry out a parametric study of twelve design variables. Five input variables were considered to be significant and were used in the regression equations. To test accuracy of simplified method, calculated results were compared with DOE-2 simulated results. Test result showes a good agreement with the simulation result with an error of 5.9∼7.6%. It is expected that this method can be used as an easy prediction tool for comparing energy use of different cooling plants during the early design stage.

Efficient Prediction-based Video Rate Control Technique (효과적인 예측 기반 비디오 비트율 제어 기법)

  • 김진열;김영로;고성제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1555-1562
    • /
    • 1999
  • Various video rate control techniques have been proposed for the transmission of video under fixed channel capacity. In most techniques, the coding parameters and quantizer scaling factors are determined based on information derived from previously coded data. In this paper, an successfully used for video rate-control. Experimental results show that the proposed prediction-based rate control scheme can efficiently regulate the bit-rate caused by dramatic scene change and have better PSNR performance than the TM5 rate control mechanism.

  • PDF

On-line Stabilizing Control Scheme for Power System (On-line 안정화 제어기법)

  • Oh, Tae-Kyoo;Kim, Hak-Man;Suh, Eui-Suk;Kim, Il-Dong;Kim, Yong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.903-906
    • /
    • 1997
  • When large capacity generation stations that consist of several large units tend to pull out of step from main power system, stabilizing control scheme as emergency control for preventing loss of synchronism of the whole stations with the remaining system is devided into two steps that the first step is to perform on-line prediction for out-of-step and the next step is on-line calculation of the amount of generation shedding for the rest of generators to be in step when out of step is expected. This paper presents on-line prediction scheme for out-of-step based on P-$\delta$ curve estimation using real-time measurement and on-line calculation of generation shedding. The proposed stabilizing scheme was applied to case study of real power system and the results obtained by the method compare well with the results by simulation.

  • PDF

Fixed Point Implementation of the QCELP Speech Coder

  • Yoon, Byung-Sik;Kim, Jae-Won;Lee, Won-Myoung;Jang, Seok-Jin;Choi, Song_in;Lim, Myoung-Seon
    • ETRI Journal
    • /
    • v.19 no.3
    • /
    • pp.242-258
    • /
    • 1997
  • The Qualcomm code excited linear prediction (QCELP) speech coder was adopted to increase the capacity of the CDMA Mobile System (CMS). In this paper, we implemented the QCELP speech coding algorithm by using TMS320C50 fixed point DSP chip. Also the fixed point simulation was done with C language. The computation complexity of QCELP on TMS320C50 was 10k words and data memory was 4k words. In the normal call test on the CMS, where mobile to mobile call test was done in the bypass mode without double vocoding, mean opinion score for the speech quality was he Qualcomm code excited linear prediction (QCELP) speech quality was 3.11.

  • PDF