• 제목/요약/키워드: capacity of coefficient

검색결과 1,012건 처리시간 0.029초

Study on structural damping of aluminium using multi-layered and jointed construction

  • Nanda, B.K.;Behera, A.K.
    • Structural Engineering and Mechanics
    • /
    • 제20권6호
    • /
    • pp.631-653
    • /
    • 2005
  • In this work, the mechanism of damping and its theoretical evaluation for layered aluminium cantilever structures jointed with a number of equispaced connecting bolts under an equal tightening torque have been considered. Extensive experiments have been conducted on a number of specimens for comparison with numerical results. Intensity of interface pressure, its distribution pattern, dynamic slip ratio and kinematic coefficient of friction at the interfaces, relative spacing of the connecting bolts, frequency and amplitude of excitation are found to play a major role on the damping capacity of such structures. It is established that the damping capacity of structures jointed with connecting bolts can be improved largely with an increase in number of layers maintaining uniform intensity of pressure distribution at the interfaces. Thus the above principle can be utilized in practice for construction of aircraft and aerospace structures effectively in order to improve their damping capacity which is one of the prime considerations for their design.

토목섬유를 사용한 무처리 연약지반과 성토사이의 수평배수층 (Geotextiles Horizontal Drain between Earth Fills and Natural Soft Ground)

  • 이형규;공길용;김현태
    • 한국농공학회지
    • /
    • 제44권4호
    • /
    • pp.129-138
    • /
    • 2002
  • This paper presents a study on the discharge capacity of geotextiles as a horizontal drain layer placed between the layers of earth fill and natural soft ground. Required discharge capacity of geotextiles as drain layers estimated by consolidation analysis is proportional to the consolidation coefficient of the ground soils and the width of the earth fills. The field discharge capacity of the geotextiles are measured by the hydraulic transmissivity test. And the results show wide variation according to the material characteristics of geotextiles, water content of the soils, vertical pressure, and etc. For the short horizontal drain length, geotextile filter mat can be used for the horizontal drain layer. And f3r the long drain($25{\sim}55m$), it is used for the drain together with Bord Drain.

Design and Analysis of Fuzzy Control in a Variable Speed Refrigeration System

  • Hua, Li;Jeong, Seok-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권2호
    • /
    • pp.61-69
    • /
    • 2007
  • This paper deals with fuzzy control with a feedforward compensator to progress both energy saving and coefficient of performance (COP) in a variable speed refrigeration system. Both the capacity and superheat are controlled simultaneously and independently in the system. By adopting the fuzzy theory, the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can reduce influence of the interfering loop between the capacity and superheat. Some experiments are conducted to design appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system in spite of its inherent strong non-linearity. Also, the fuzzy control performances were investigated by comparing to the model based PI control experimental results to evaluate transient behavior under the control.

실리카겔-물계 흡착식 냉동기에 관한 실험적 연구 (An Experimental Study of Adsorption Chiller using Silica gel-Water)

  • 권오경;윤재호;김종하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1119-1124
    • /
    • 2006
  • The objectives of this paper are to investigate the performance of silica gel-water adsorption refrigeration system with heat recovery process from the system experiment. This system can be driven by waste heat at near ambient temperature from $60^{\circ}C$ to $90^{\circ}C$. The cooling capacity and coefficient of performance(COP) were measured from various experimental conditions. An experimental results revealed the influence of operating temperatures(hot, cooling and chilled water), water flow rates, and adsorption-desorption cycle times on cooling capacity and COP. Under the standard conditions of $80^{\circ}C$ hot water, $25^{\circ}C$ cooling water, $14^{\circ}C$ chilled water inlet temperatures and 420sec cycle time, a cooling capacity of 1.14kW and a COP for cooling of 0.55 can be achieved.

  • PDF

Fuzzy Control with Feedforward Compensator of Superheat in a Variable Speed Refrigeration System

  • Hua, Li;Lee, Dong-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.252-262
    • /
    • 2007
  • In this paper, we suggest fuzzy control with feedforward compensator of superheat to progress both energy saving and coefficient of performance(COP) in a variable speed refrigeration system. The capacity and superheat are controlled simultaneously and independently by an inverter and an electronic expansion valve respectively for saving energy and improving COP in the system. By adopting the fuzzy control. the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can eliminate influence of the interfering loop between capacity and superheat. Some experiments are conducted to design the appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system with inherent strong non-linearity.

Power Quality Optimal Control of Railway Static Power Conditioners Based on Electric Railway Power Supply Systems

  • Jiang, Youhua;Wang, Wenji;Jiang, Xiangwei;Zhao, Le;Cao, Yilong
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1315-1325
    • /
    • 2019
  • Aiming at the negative sequence and harmonic problems in the operation of railway static power conditioners, an optimization compensation strategy for negative sequence and harmonics is studied in this paper. First, the hybrid RPC topology and compensation principle are analyzed to obtain different compensation zone states and current capacities. Second, in order to optimize the RPC capacity configuration, the minimum RPC compensation capacity is calculated according to constraint conditions, and the optimal compensation coefficient and compensation angle are obtained. In addition, the voltage unbalance ${\varepsilon}_U$ and power factor requirements are satisfied. A PSO (Particle Swarm Optimization) algorithm is used to calculate the three indexes for minimum compensating energy. The proposed method can precisely calculate the optimal compensation capacity in real time. Finally, MATLAB simulations and an experimental platform verify the effectiveness and economics of the proposed algorithm.

식이섬유의 수분결합력에 관한 연구 (Water Binding Capacity of Vegetable Fiber)

  • 계수경
    • 한국식품영양학회지
    • /
    • 제9권3호
    • /
    • pp.231-235
    • /
    • 1996
  • The water binding capacity(WC) of acid detergent fiber(ADF) was estimated. The WBC of raw vegetables ranged from 5. 1g to 24.7g water/g ADF. WBC was high in pepers and low in welsh onions. The correlation coefficients between WBC and fiber components were examined to fled which component is responsible for the deteruuning ability to bind water. The correlation coefficient between WBC and cellulose was +0.8. The binding capacity of water by fiber was affected positively by cellulose. fermentation increased in WBC of ADF. Changes of no in accordance with pH changes were evaluated at pH 2, 5.2 and 6. In all cases, WBC was high In weak acid and neutral.

  • PDF

이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석 (Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger)

  • 한도영;박관준
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

LNG 선박용 spring load 안전방출밸브의 유량 성능시험 (Flow capacity test of spring load safety relief valves used in LNG)

  • 박경암;이생희;김경권;고장훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2006
  • Many LNG ships will be constructed in Korea and the demand of safety valves is increasing. The most important performance of the developed safety relief valves for LNG ship is flow capacity. Flow capacity tests for 8 sizes of developed safety valves were conducted in the high pressure gas flow standard system in KRISS. The initial spring force adjustment was important for setting pressure of the safety valve. The procedure of data reduction and evaluation of the safety valve performance are suggested. This procedure was approved by French Bureau Veritas and Lloyd's Register.

  • PDF

Ecotourism Carrying Capacity and the Potentiality of the Safari Park of Bangladesh

  • Masum, Kazi Mohammad;Al Mamun, Abdullah;Rahman, Zahed Mohammad Malekur;Rahman, Md. Motlubur;Newaz, Md. Shah;Redowan, Mohammad
    • Journal of Forest and Environmental Science
    • /
    • 제29권4호
    • /
    • pp.292-299
    • /
    • 2013
  • The study was undertaken to assess the tourist's carrying capacity and to explore ecotourism potential of Bangabandhu Sheikh Mujib Safari Park, the only safari park of Bangladesh. Carrying capacity was assessed both from physical and social aspect. On the other hand, 250 visitors were interviewed with semi structured questionnaire for ecotourism prospect evaluation along with some secondary data. The total daily-allowed visit was 17,300 with rotation coefficient of 3.46. Maximum daily average numbers of tourists were relatively below the physical carrying capacity of the Park (5,000). The social carrying capacity was 4.38 persons per day. As there are different categories of visitors, their choice of encounters and number of expected encounters also varied. Each year, the total tourist's number varied significantly ($p{\leq}0.05$). That proved the safari park had immense tourist prospect. 85 percent visitors were from lower and middle class family as entrance fees and other fees inside were very cheap in relation to other private amusement place. The ecological perspective of the park will remain unaltered if the carrying capacities of the area are followed with sustainability. Therefore, it is the proper time for taking appropriate decision.