• Title/Summary/Keyword: capacity modification factor

Search Result 64, Processing Time 0.023 seconds

Numerical study on buckling of steel web plates with openings

  • Serror, Mohammed H.;Hamed, Ahmed N.;Mourad, Sherif A.
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1417-1443
    • /
    • 2016
  • Cellular and castellated steel beams are used to obtain higher stiffness and bending capacity using the same weight of steel. In addition, the beam openings may be used as a pass for different mechanical fixtures such as ducts and pipes. The aim of this study is to investigate the effect of different parameters on both elastic and inelastic critical buckling stresses of steel web plates with openings. These parameters are plate aspect ratio; opening shape (circular or rectangular); end distance to the first opening; opening spacing; opening size; plate slenderness ratio; steel grade; and initial web imperfection. The web/flange interaction has been simplified by web edge restraints representing simply supported boundary conditions. A numerical parametric study has been performed through linear and nonlinear finite element (FE) models, where the FE results have been verified against both experimental and numerical results in the literature. The web plates are subject to in-plane linearly varying compression with different loading patterns, ranging from uniform compression to pure bending. A buckling stress modification factor (${\beta}$-factor) has been introduced as a ratio of buckling stress of web plate with openings to buckling stress of the corresponding solid web plate. The variation of ${\beta}$-factor against the aforementioned parameters has been reported. Furthermore, the critical plate slenderness ratio separating elastic buckling and yielding has been identified and discussed for two steel grades of DIN-17100, namely: ST-37/2 and ST-52/3. The FE results revealed that the minimum ${\beta}$-factor is 0.9 for web plates under uniform compression and 0.7 for those under both compression and tension.

An Improvement for Evaluating Load Carrying Capacity of Long Span Bridge with respect to Passing Vehicles (통행차량에 의한 장대교량의 내하력 평가기법 개선)

  • Shin Jae-In;Park Chang-Ho;Lee Sang-Soon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.339-342
    • /
    • 2005
  • This paper presents the development of a method for determining the response modification factor, using traffic load. The proposed method is based on the results of computer simulations of traffic action effects. The simulation program generates random traffic actions for defined traffic conditions and determines the frequency distribution of maximum traffic action effects. Therefore, this study is adopted to long-span bridge for the verification of the proposed method. A comparison between the proposed method and present method shows good agreement in estimating the modified load carrying capacity of bridges.

  • PDF

Tribological Behavior of Lubricating Oil-Based Nanofluids Containing Ag and Carbon Nanoparticles (Ag 및 탄소 나노윤활유의 제조 및 윤활특성 평가)

  • Choi, Cheol;Jung, Mi-Hee;Choi, Young-Min;Oh, Jae-Myung
    • Korean Journal of Materials Research
    • /
    • v.18 no.11
    • /
    • pp.610-616
    • /
    • 2008
  • Oil-based nanofluids were prepared by dispersing Ag, graphite and carbon black nanoparticles in lubricating oil. Agglomerated nanoparticles were dispersed evenly with a high-speed bead mill and/or ultrasonic homogenizer, and the surfaces of the nanoparticles were modified simultaneously with several dispersants. Their tribological behaviors were evaluated with a pin-on-disk, disk-on-disk and four-ball EP and wear tester. It is obvious that the optimal combination of nanoparticles, surfactants and surface modification process is very important for the dispersity of nanofluids, and it eventually affects the tribological properties as a controlling factor. Results indicate that a relatively larger size and higher concentration of nanoparticles lead to better load-carrying capacity. In contrast, the use of a smaller size and lower concentration of particles is recommended for reducing the friction coefficient of lubricating oil. Moreover, nanofluids with mixed nanoparticles of Ag and graphite are more suitable for the improvement of load-carrying capacity and antiwear properties.

Initial stiffness and moment capacity assessment of stainless steel composite bolted joints with concrete-filled circular tubular columns

  • Wang, Jia;Uy, Brian;Li, Dongxu
    • Steel and Composite Structures
    • /
    • v.33 no.5
    • /
    • pp.681-697
    • /
    • 2019
  • This paper numerically assesses the initial stiffness and moment capacity of stainless steel composite bolted joints with concrete-filled circular tubular (CFCT) columns. By comparing with existing design codes including EN 1993-1-8 and AS/NZS 2327, a modified component method was proposed to better predict the flexural performance of joints involving circular columns and curved endplates. The modification was verified with independent experimental results. A wide range of finite element models were then developed to investigate the elastic deformations of column face in bending which contribute to the corresponding stiffness coefficient. A new design formula defining the stiffness coefficient of circular column face in bending was proposed through regression analysis. Results suggest that a factor for the stiffness coefficient of endplate in bending should be reduced to 0.68, and more contribution of prying forces needs to be considered. The modified component method and proposed formula are able to estimate the structural behaviour with reasonable accuracy. They are expected to be incorporated into the current design provisions as supplementary for beam-to-CFCT column joints.

Shake table testing of confined adobe masonry structures

  • Khan, Faisal Zaman;Ahmad, Muhammad Ejaz;Ahmad, Naveed
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.149-160
    • /
    • 2021
  • Buildings made using the locally available clay materials are amongst the least expensive forms of construction in many developing countries, and therefore, widely popular in remote areas. It is despite the fact that these low-strength masonry structures are vulnerable to seismic forces. Since transporting imported materials like cement and steel in areas inaccessible by motorable roads is challenging and financially unviable. This paper presents, and experimentally investigates, adobe masonry structures that utilize the abundantly available local clay materials with moderate use of imported materials like cement, aggregates, and steel. Shake-table tests were performed on two 1:3 reduce-scaled adobe masonry models for experimental seismic testing and verification. The model AM1 was confined with vertical lightly reinforced concrete columns provided at all corners and reinforced concrete horizontal bands (i.e., tie beams) provided at sill, lintel, and eave levels. The model AM2 was confined only with the horizontal bands provided at sill, lintel, and eave levels. The models were subjected to sinusoidal base motions for studying the damage evolution and response of the model under dynamic lateral loading. The lateral forcedeformation capacity curves for both models were developed and bi-linearized to compute the seismic response parameters: stiffness, strength, ductility, and response modification factor R. Seismic performance levels, story-drift, base shear coefficient, and the expected structural damages, were defined for both the models. Seismic performance assessment of the selected models was carried out using the lateral seismic force procedure to evaluate their safety in different seismic zones. The use of vertical columns in AM1 has shown a considerable increase in the lateral strength of the model in comparison to AM2. Although an R factor equal to 2.0 is recommended for both the models, AM1 has exhibited better seismic performance in all seismic zones due to its relatively high lateral strength in comparison to AM2.

Evaluation of Seismic Design Parameters for Nonstructural Components Based on Coupled Structure-Nonstructural 2-DOF System Analysis (구조물-비구조요소 2자유도 결합시스템 해석을 통한 비구조요소 내진설계변수 평가)

  • Bae, Chang Jun;Lee, Cheol-Ho;Jun, Su-Chan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.105-116
    • /
    • 2022
  • Seismic demand on nonstructural components (NSCs) is highly dependent on the coupled behavior of a combined supporting structure-NSC system. Because of the inherent complexities of the problem, many of the affecting factors are inevitably neglected or simplified based on engineering judgments in current seismic design codes. However, a systematic analysis of the key affecting factors should establish reasonable seismic design provisions for NSCs. In this study, an idealized 2-DOF model simulating the coupled structure-NSC system was constructed to analyze the parameters that affect the response of NSCs comprehensively. The analyses were conducted to evaluate the effects of structure-NSC mass ratio, structure, and NSC nonlinearities on the peak component acceleration. Also, the appropriateness of component ductility factor (Rp) given by current codes was discussed based on the required ductility capacity of NSCs. It was observed that the responses of NSCs on the coupled system were significantly affected by the mass ratio, resulting in lower accelerations than the floor spectrum-based response, which neglected the interaction effects. Also, the component amplification factor (ap) in current provisions tended to underestimate the dynamic amplification of NSCs with a mass ratio of less than 15%. The nonlinearity of NSCs decreased the component responses. In some cases, the code-specified Rp caused nonlinear deformation far beyond the ductility capacity of NSCs, and a practically unacceptable level of ductility was required for short-period NSCs to achieve the assigned amount of response reduction.

Surface Modification of TiO2 Nanoparticles with Phenyltrimethoxysilane in Dye-sensitized Solar Cells

  • Chan, Yong-June;Kum, Byung-Gon;Park, Yoon-Cheol;Kong, Eui-Hyun;Jang, Hyun Myung
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.415-418
    • /
    • 2014
  • Phenyltrimethoxysilane (PTMS) was anchored onto the sensitized $TiO_2$ nanoparticles. This insulating molecular layer effectively inhibited the charge recombination at the interface of $TiO_2$/electrolyte in the dye-sensitized solar cells (DSCs) without sacrificing the dye-loading capacity of the nanocrystalline $TiO_2$. DSCs using PTMS-modified $TiO_2$ exhibited a short-circuit current ($J_{SC}$) of $15.9mA/cm^2$, an open-circuit voltage ($V_{OC}$) of 789 mV, and a fill factor (FF) of 68.2%, yielding an overall conversion efficiency (${\eta}$) of 8.55% under $100mW/cm^2$ illumination. The resulting cell efficiency was improved by ~10% as compared with the reference cell.

An Evaluation of Lap Splice Length of Epoxy Coated Reinforcements Using Beam-End Test (보-단부 시험을 이용한 에폭시 도막 철근의 겹침 이음길이 평가)

  • Kim, Jee-Sang;Kang, Won Hyeak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.2
    • /
    • pp.175-182
    • /
    • 2020
  • The application of epoxy coated reinforcements is increased as a means to prevent a corrosion of reinforcements embedded in reinforced concrete structures, However, epoxy coating may reduce the bond capacity between concrete and reinforcement, which results a longer development length and lap splice length. This paper aims to the possibility of modification in lap splice length from reduction of basic development length which was confirmed using a direct pull out test. Total 36 beam specimens were tested to compare the lap splice properties of normal and epoxy coated reinforcements with beam-end test for various lap lengths and diameters of reinforcements. According to the results on failure modes, deformations, and crack widths of this experiments, the modification factor of 1.2 should be used, though the direct bond capacity is assured through direct pull out test.

Response Modification Coefficient Using Natural Period (고유진동주기를 이용한 응답수정계수)

  • 김희중
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.229-237
    • /
    • 1996
  • In some current procedures, ground motions from different sources have been scaled by their peak ground accelerations and combined to obtain smoothed response spectra for specific regions. As consideration of the inelastic deformation capacity of structure, inelastic deformations are permitted under seismic ground excitation in all codes. In the ATC(Applied Technology Council) and UBC(Uniform Building Code), the inelastic design spectrum is obtained by reducing the elastic design spectrum by a factor that is independent of structural period. In this study, the average of nonlinear response spectra calculated from a sample of 20 records for each event are constructed to obtain the smoothed response spectra. These response spectra are used to examine the effects of structural strength factors such as the yield strength ratio and damping value. Through the regression analysis of nonlinear response of system for a given damping value and yield strength ratio, the required yield strength for seismic design can be estimated for a certain earthquake event. And a response modification coefficient depending on the natural period for current seismic design specifications are proposed.

  • PDF

Evaluation of seismic performance factors for tension-only braced frames

  • Shariati, Mahdi;Lagzian, Majid;Maleki, Shervin;Shariati, Ali;Trung, Nguyen Thoi
    • Steel and Composite Structures
    • /
    • v.35 no.4
    • /
    • pp.599-609
    • /
    • 2020
  • The tension-only braced frames (TOBFs) are widely used as a lateral force resisting system (LFRS) in low-rise steel buildings due to their simplicity and economic advantage. However, the system has poor seismic energy dissipation capacity and pinched hysteresis behavior caused by early buckling of slender bracing members. The main concern in utilizing the TOBF system is the determination of appropriate performance factors for seismic design. A formalized approach to quantify the seismic performance factor (SPF) based on determining an acceptable margin of safety against collapse is introduced by FEMA P695. The methodology is applied in this paper to assess the SPFs of the TOBF systems. For this purpose, a trial value of the R factor was first employed to design and model a set of TOBF archetype structures. Afterwards, the level of safety against collapse provided by the assumed R factor was investigated by using the non-linear analysis procedure of FEMA P695 comprising incremental dynamic analysis (IDA) under a set of prescribed ground motions. It was found that the R factor of 3.0 is appropriate for safe design of TOBFs. Also, the system overstrength factor (Ω0) was estimated as 2.0 by performing non-linear static analyses.