• 제목/요약/키워드: capacity loss

검색결과 1,675건 처리시간 0.023초

Predicting the flexural capacity of RC beam with partially unbonded steel reinforcement

  • Wang, Xiao-Hui;Liu, Xi-La
    • Computers and Concrete
    • /
    • 제6권3호
    • /
    • pp.235-252
    • /
    • 2009
  • Due to the reduction of bond strength resulting from the high corrosion level of reinforcing bars, influence of this reduction on flexural capacity of reinforced concrete (RC) beam should be considered. An extreme case is considered, where bond strength is complete lost and/or the tensile steel are exposed due to heavy corrosion over a fraction of the beam length. A compatibility condition of deformations of the RC beam with partially unbonded length is proposed. Flexural capacity of this kind of RC beam is predicted by combining the proposed compatibility condition of deformations with equilibrium condition of forces. Comparison between the model's predictions with the experimental results published in the literature shows the practicability of the proposed model. Finally, influence of some parameters on the flexural capacity of RC beam with partially unbonded length is discussed. It is concluded that the flexural capacity of the beam may not be influenced by the completely loss of bond of the whole beam span as long as the tensile steel can yield; whether or not the reduction of the flexural capacity of the beam resulting from the loss of bond over certain length may occur depends on the detailed parameters of the given beam.

시뮬레이션을 통한 AIN IP 시스템의 호처리용량 분석 (Performance Analysis of an Intelligent Peripheral System in Advanced Intelligent Network)

  • 서재준;최고봉;여건민;전치혁
    • 산업공학
    • /
    • 제11권3호
    • /
    • pp.77-87
    • /
    • 1998
  • Intelligent Peripheral(IP) system is to provide specialized resource functions (SRF) such as playing announcement, collecting user information, and receiving messages in the Advanced Intelligent Network (AIN). We analyze the call processing capacity of an AIN IP system being developed in ETRI through an extensive simulation using SLAM II under a variety of AIN service scenarios. We consider televoting (VOT) and universal personal telecommunication (UPT) services which are to be provided at the fit implementation of the AIN in Korea. As the performance criteria to determine the call processing capacity, processor utilization, delay and call loss probability are considered. It turns out that the major processor called SAMP is the bottleneck processor, the service response delay dominates the delay performance, and the call loss probability becomes the primary criterion in determining the call processing capacity of the AIN IP system. It is also shown that the call processing capacity of the AIN IP system is determined by the utilization of the processor and the delay performance when the VOT ratio is below 70 percent but it is determined by the call loss probability due to the lack of service channels for providing the SRF operations.

  • PDF

장시간 충방전에 따른 VRFB-ESS의 용량 손실 회복에 대한 연구 (Study and Recovery on the Capacity Loss after the Long Charge-discharge Operation of VRFB-ESS)

  • 서혜경;박원식;박재우;김강산;최한솔
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.181-187
    • /
    • 2022
  • As the charges/discharges of VRFB-ESS were repeated during 150cycles or more, the capacity of electrolyte in VRFB-ESS was decreased little by little. It results from the decreasing of the level of anolyte and the increasing of the valance value of the catholyte. Then, we tried to recover the capacity loss with 3 different ways. The first way was that the levels of anolyte and catholyte were allowed to be evenly equalized when the difference in the levels of two different electrolytes were severe. The second one was to lessen the valance value of the catholyte through the reduction reaction to 4-valant ions of 5-valant ions in the catholyte with the reductant, oxalic acid. The last one was that the all electrolytes of analyte and catholyte were allowed to be electro-chemically reduced to 3.5 of the valance value by oxidizing new electrolyte with 3.5 valance ions. The last way was the most effective to recover the capacity loss.

국내 천정의 정호 수두 손실 (Well Loss of Shallow Water in South Korea)

  • 한정상
    • 물과 미래
    • /
    • 제10권1호
    • /
    • pp.20-24
    • /
    • 1977
  • 43,000 shallow water wells have been installed as a part of all weather irrigation water supply project executed during 1969 to 1970 in all over Korea penninsula in order to solve water shortage problem of farming land by developing shallow ground water reserved in unconsolidated materials. But after 3 years later it was reported that 34% of the wells were abandoned by the reasons of artificial and natural defects. 48 wells distributed uniformly in the penninsula are selected to determine their well loss constants, relation between well loss and specific capacity, and tophographic classification of the well loss on the shallow water well. The results show that average well loss consatnt and the value of $CQ^2/S_w$ is ranged from $5.95{\times}10^{-5}\;to\;3.65{\times}10^{-8}Day^2M^{-5}$ and from 35.5% to maximum 68.48% respectvely and that relation between specific capacity and well loss constant can be approximately formulated as $C=0.61S_p2.246$ However this result indicates that most wells installed in this time have too high value of well loss constant $CQ^2/S_w$ in comparison with properly deseigned well. The most favorable and producable water bearing formation among unconsolidated deposits such as sand & gravel, boulderly gravel, clayey boulderly gravel, and sand formation in Korea is sand formation deposited in center of valley.

  • PDF

STEAM GENERATOR TUBE INTEGRITY ANALYSIS OF A TOTAL LOSS OF ALL HEAT SINKS ACCIDENT FOR WOLSONG NPP UNIT 1

  • Lim, Heok-Soon;Song, Tae-Young;Chi, Moon-Goo;Kim, Seoung-Rae
    • Nuclear Engineering and Technology
    • /
    • 제46권1호
    • /
    • pp.39-46
    • /
    • 2014
  • A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.

Nickel Hexacyanoferrate 이온교환체의 전기화학적 특성에 관한 연구 (A Study on the Electrochemical Characteristics of the Nickel Hexacyanoferrate Ion Exchanger)

  • 황영기
    • 한국산업융합학회 논문집
    • /
    • 제19권4호
    • /
    • pp.198-205
    • /
    • 2016
  • For the study on the ion exchange of nickel hexacyanoferrate(NiHCNFe) electrode with the several cations, the film of hexacyanoferrate was prepared on the bare nickel surface by the electrochemical and chemical methods in the solution composed with 5mM K3Fe(CN)6 and 100mM KNO3. To compare the capability of the ion exchange of NiHCNFe film electrode, the repeated cyclic voltammograms were measured in the 0.5M cation nitrate solutions at $25^{\circ}C$ and pH7. It was found that the capacity of the electrochemically derivatized NiHCNFe reduced in the rate of 0.5~0.7%/cycle and was nearly exhausted at the 150th potential cycle. Better result was obtained from that the capacity loss of the chemically assembled NiHCNFe was less than 0.02%/cycle for 5,000cycles. Furthermore, the residual capacity was more than 30% at the 5,000th cycle.

Buckling capacity of uniformly corroded steel members in terms of exposure time

  • Rahgozar, Reza;Sharifi, Yasser;Malekinejad, Mohsen
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.475-487
    • /
    • 2010
  • Most of steel structures in various industries are subjected to corrosion due to environmental exposure. Corrosion damage is a serious problem for these structures which may reduce their carrying capacity. These aging structures require maintenance and in many cases, replacement. The goal of this research is to consider the effects of corrosion by developing a model that estimates corrosion loss as a function of exposure time. The model is formulated based on average measured thickness data collected from three severely corroded I-beams (nearly 30 years old). Since corrosion is a time-dependent parameter. Analyses were performed to calculate the lateral buckling capacity of steel beam in terms of exposure time. Minimum curves have been developed for assessment of the remaining lateral buckling capacity of ordinary I-beams based on the loss of thicknesses in terms of exposure time. These minimum curves can be used by practicing engineers for better estimates on the service life of corrosion damaged steel beams.

열 열화한 열전도성 실리콘 고무의 전기특성 (Electric Properties of Thermal Conductive Silicone Rubber due to Thermally Degradation)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.835-840
    • /
    • 2016
  • In this study, the electrostatic capacity and dielectric loss tangent for $20{\mu}m$ thick thermal conductivity silicone rubber which is heated at 80 degrees for 8 hours has been measured at temperature of $30^{\circ}C{\sim}170^{\circ}C$, frequency of 0.1~1 MHz. The results of degradation evaluation by this study are as follows. In low frequency, it found that the electrostatic capacity decreased with increasing temperature. On the other hand, it confirmed that the range of the electrostatic capacity narrowed with increasing frequency. It confirmed that there are the carboxylic acid structure and C-O bonding at range of wave number 1,000cm-1 to 1,300cm-1.

전기자동차 충전소의 적정 용량 결정 (Determining the Proper Capacity of Electric Vehicle Charging Station)

  • 홍준희;최중인;이종현;남영우
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1911-1915
    • /
    • 2009
  • The problem of determining the proper capacity of electric vehicle charging station is studied in the presented paper. Based on the expected arrival rate and the expected charging time, we calculate the proper capacity that guarantees electric vehicles get service better than a given lower bound which is termed the loss of charging probability. The problem is studied by using certain queueing models. We first formulate the problem as a queueless model of type M/M/n/n, known as the Erlang loss system. And then the M/M/n/K type queueing model is formulated to consider the parking space constraint. Results of the study may be used for designing the electric vehicle charging station.

탄소섬유로 휨보강된 RC 보의 부착 손실에 대한 거동 특성 (Structural Capacity of RC Beam Retrofitted by CFS with Bond Loss)

  • 서수연;윤현도;최기봉
    • 콘크리트학회논문집
    • /
    • 제19권6호
    • /
    • pp.795-802
    • /
    • 2007
  • 최근 탄소섬유를 보강재로 사용한 구조 부재의 휨 거동에 관한 많은 연구가 진행되어 왔으나, 대부분의 연구는 FRP를 이용한 설계법의 개발과 구조 성능 평가에 초점이 맞추어져 있기 때문에 장기적으로 보강재 또는 부착 상태의 변화에 따른 구조 성능 변화 등과 같은 현상을 반영하기에는 아직까지 부족한 점이 있다. 이에 따라 현재까지 보강된 FRP의 성능 저하에 따른 구조물의 구조 내력 저하에 대하여 구체적인 방안이 제시되기 위해서는 많은 사례 조사와 물성 변화를 고려한 구조물의 거동 특성 변화에 대한 지속적인 연구가 요망된다. 본 연구에서는 시간에 따라 저하되는 부착률의 변화에 따른 구조 성능의 변화를 관찰하고자, CFS의 부착률 변화와 부착 형태의 차이에 의한 거동 차이를 실험을 통해 밝히고, 기존 제안식을 이용하여 부착률과 부착 형태 차이에 따른 구조 성능 변화를 예측함으로써 CFS로 보강된 이후 부착률이 저하된 경우에 대한 거동 특성 평가방안을 제시하였다. 또한, 비선형 단면 해석을 통하여 실험 결과와 비교 검토하여 적정 해석 방법을 제시하였다.