• 제목/요약/키워드: capacitor motor

검색결과 215건 처리시간 0.022초

통전전류 특성을 이용한 모터 기동용 전해 커패시터 폭발 방지 방법 (The Explosion Prevention Method for Electrolytic Motor Start Capacitors using Current Characteristic)

  • 김재현;박진영;박광묵;방선배;김용운
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1836-1843
    • /
    • 2017
  • In this paper, we investigated fire cases those are believed to be caused by explosion of a electrolytic motor start capacitor. Using two types of commercially available electrolytic motor start capacitors, capacitor current and the possibility of capacitor explosion were tested. And the ignition possibility of the internal material leaked from a capacitor was also tested. In addition, experiments were conducted to see if the fire could spread when a capacitor was exposed to an external flame. From our test we observed that the current of the electrolytic motor start capacitor rose continuously to a certain level by product, if the capacitor was continuously energized with working voltage, and then the capacitor was exploded. The gas and liquid leaked from the capacitor by the explosion could ignite by an electric arc and an external flame. The capacitor current at explosion was different product by product, but each product had a certain current level at explosion. And the increase rate of the capacitor current until explosion was 24% and 31% for the products used in the experiment. We proposed the capacitor explosion prevention method that cuts off power when the capacitor current rises to a certain threshold level. The proposed method can be used if the current of the applied electrolytic motor start capacitor rises continuously and then the capacitor is exploded at a certain current level when the capacitor is energized continuously.

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

콘덴서 런 단상유도전동기의 설계적 고찰

  • 원종수
    • 전기의세계
    • /
    • 제31권2호
    • /
    • pp.132-140
    • /
    • 1982
  • Designing the capacitor-run motor for balanced operation is accompanied with the excessive capacitor value and low capacitor terminal voltage of condenser. As a solution for this problems, It was reported the design by equal volt-ampere method. The running characteristics of capacitor-run motor by this method due to the balancing point selection, however, has a room to be studied further. This paper deals with the determination of the winding ratio and capacitor value of a permarient-split capacitor motor by balanced operation and equal volt-ampere method at the different load points. The analysis of the running characteristics of a motor and its designing method also presented for both cases. It concluded that the running characteristics due to the equal volt-ampere operation are very close to the balanced operation.

  • PDF

유도전동기 역률 보상 파라미터의 적정성 검토 (Suitability Review for Power Correction Parameter of Induction Motor)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.101-109
    • /
    • 2008
  • 유도전동기는 회전에 필요한 자계를 유지하기 위해 무효전력을 필요로 한다. 만일 전원측을 대신하여 부하측에서 무효전력이 제공될 경우 역률은 향상될 것이다. 유도전동기의 역률은 대개 낮으므로 커패시터로 보상이 필요하다. 내선규정에서 유도전동기의 역률 보상 커패시터의 용량은 출력에 따라 추천된 값의 설치를 권고하고 있다. 그러나 유도전동기는 같은 출력에서도 회전수에 따라 특성이 달라지므로 역률이 일정하지 않아 용량에 따라 일정한 커패시터의 적용은 부적합하다. 그래서 본 논문에서는 같은 출력조건에서 속도에 따라 기존에 제시된 값과 비교한 결과 역률 보상 커패시터의 용량이 약간 높게 설정되어야 함을 확인하였다.

보조권선 전압제어에 의한 커패시터 런 유도전동기의 속도제어 (Speed Control of Capacitor-Run Induction Motor Using Voltage Control of the Auxiliary Winding)

  • 류준형;이광원
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.357-362
    • /
    • 1999
  • This paper presents a speed control method for the capacitor-run induction motor. The equivalent circuit of the motor is analyzed using the forward(Positive sequence) and backward(negative sequence) components, and simple circuit equations are obtained. Simulations for the speed control are performed by adjusting the voltage magnitude of the auxiliary winding. A prototype system has been implemented which consists of an inverter and a controller with TMS320C31 digital signal processor. The experimental results using 1/4hp capacitor-run induction motor show a good agreement with analyses.

  • PDF

유도전동기 효율향상에 따른 역률 보상 콘덴서 최적 선정에 대한 연구 (A Study on the Optimum Selection of the Power Factor Compensation Condenser According to the Improved Efficiency of Induction Motor)

  • 김종겸
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1311-1315
    • /
    • 2016
  • Induction motor requires a rotating magnetic field for rotation. Current required to generate the rotating magnetic field is immediately magnetizing current. This magnetizing current is associated with the reactive power. Induction motor is always required reactive power. If reactive power is supplied only to the power supply side, the power factor is low. Therefore, it is to compensate the power factor by connecting capacitors in parallel to the motor terminal. If the capacitor current is greater than the magnetizing current of the motor, there is a possibility that the self-excitation occurs. High voltage generated by the self-excitation leads to insulation failure on the motor. So it is necessary to calculate the power factor correction capacitor capacity the most suitable to the extent that the magnetizing current does not exceed the capacitor current. In this study, we first computed the magnetization current and the reactive power of the induction motor and then calculates a limit of the maximum power factor by comparing the magnetizing current and the capacitor current installed in order to achieve the target power factor.

VCC를 첨가한 다중 전류형 인버터 구동에 관한 연구 (A Study on Drive of the Multicurrent Source Inverter Inserting the VCC)

  • 정연택;홍일선;황락훈
    • 대한전기학회논문지
    • /
    • 제38권4호
    • /
    • pp.269-278
    • /
    • 1989
  • When the induction motor is operated by CSI, the commutation capacitance in the CSI circuit is increased according to the increase of large capacitor system. The output voltage spikes are generated at the moment of charge and discharge of the commutation capacitor. Also, since output current comprise a great number of harmonics, torque ripples of the motor are generated, having bad effects on the motor. In this study, by adopting the 18-phase multiple high Frequency Current Source Inverter (HFCSI), torque ripples generated by the voltage spikes are mostly eliminated except the 17th and 19th harmonics. To reduce the voltage spikes comprised in the output voltage, particularly, the methods of eliminating the cause of bad effect upon the motor are proposed in this paper. In the proposed method, by using additional voltage Clamping Curcuit (VCC), it is possible to select the values of commutation capacitor energy loss in commutating, the commutating capacitor, and the capacitor in the clamping circuit.

Control of Motor Drives Fed by PFC Circuits without DC-Link Electrolytic Capacitors

  • Kim, Kwang-Man;Kim, Eung-Ho;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1067-1074
    • /
    • 2018
  • This paper presents a control method for variable-speed motor drives that do not use a DC-link electrolytic capacitor. The proposed circuit consists of a power factor correction converter for boosting the DC-link voltage, an inverter for driving the motor, and a small DC-link film capacitor. By employing a small DC-link capacitor, the proposed circuit that is small, and a low cost and weight are achieved. However, because the DC-link voltage varies periodically, the control of the circuit is more difficult than that of the conventional method. Using the proposed control method, an inverter can be controlled reliably even when the capacitance of the DC-link capacitor is very small. Experiments are performed using a 1.5-kW inverter with a $20-{\mu}F$ DC-link capacitor, and the experimental results are analyzed thoroughly.

시스템 식별론을 이용한 드라이브 시스템에서의 전해 콘덴서 결함 진단 (Deterioration Diagnosis of Electrolytic Capacitor in Motor Drive System using the System using the System ID Method)

  • 김준석;송홍석;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.243-247
    • /
    • 1999
  • An electrolytic capacitor is widely used in a motor drive system. Therefore, the deterioration diagnosis of an electrolytic capacitor is needed of preventive maintenance of the system. In this paper, we propose a new diagnosis method for the electrolytic capacitor by using the system identification method, which presents the information about the capacitor's interna parameters in on-line operation an use fuzzy algorithm for the deterioration decision. We demonstrated the effectiveness of the proposed control scheme by using computer simulation.

  • PDF

구동 커패시터의 용량에 따른 단상유도전동기 출력특성에 관한 연구 (Output Characteristics of Capacitor-run type Single Phase Induction Motor considering Capacitance)

  • 김철진;이달은;진용선;최철용;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.848-850
    • /
    • 2002
  • Single phase induction motor is directly used usual source, it can be a source of an appliance such as mechanical fan, refrigerator, washing machine, etc. Especially capacitor-run single phase induction motor is suitable to make more inexpensive and high efficient products because it is more high efficiency, and good to start than other single phase induction motors. Generally, voltage and current of capacitor-run single phase induction motor transfer to the part of positive phase and negative phase based on two motor theory. In this paper, we simulate the torque characteristics to capacitance variation from single phase induction motor's equivalent circuit. Through the test using the real motor, we compare and investigate the maximum torque of run state related with capacitance and the adequacy of the converted model.

  • PDF