• Title/Summary/Keyword: capacitive component

Search Result 48, Processing Time 0.025 seconds

Calibration of SAW Based Capacitive Sensor Using Lumped Component and High Precision Gap Measurement (집중 소자를 이용한 표면 탄성파 장치 기반의 용량 성 센서 보정 및 이를 이용한 초정밀 간극 측정)

  • Kim, Jae-Geun;Ko, Byung-Han;Park, Young-Pil;Park, No-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.1
    • /
    • pp.16-21
    • /
    • 2012
  • SAW device is widely used as filters, sensors, actuators in various technologies. And capacitive sensor is tremendously used to measure pressure, gap, etc. The application of SAW device as signal conditioner of capacitive sensor reduces noise level and enables high precision measurement. The response increase of SAW based capacitive sensor is produced just before the two capacitive electrode contacts by the existence of parasitic resistance of capacitive electrode. In this paper, we analyze the effects of parasitic resistance and propose the calibrating method using lumped component and execute the high precision gap measurement using calibrated system. And xx nm resolution and yy ${\mu}m$ stroke was attained.

Analysis of Resistive and Capacitive Leakage Current according to Wiring Type and Length at Cattle Barn (우사(牛舍)에서 전기배선의 종류와 길이에 따른 저항성 및 용량성 누전전류 분석)

  • Yoo, Sang-Ok;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.34-39
    • /
    • 2014
  • This paper is aimed to prevent danger of electrical fire at cattle barn to detect resistive and capacitive leakage current component for wiring type and length. In order to analysis for electric leakage component for cattle barn sizes and normal buildings, this paper was studied field state investigation which are at cattle barn companies(10 companies) in Cheong-won location and normal buildings at Nam-bu market in Jeon-ju location. Market to deduce the problems of electric leakage component is analyzed. The resistive and capacitive leakage current component for wiring type and length is analyzed at Beon-young cattle barn. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in cattle barn. It is acceptable for electrical equipment use in an cattle barn.

A New Method for Resistive Leakage Current Measurement (새로운 저항성 누전전류 측정 방법)

  • Ham, Seung-Jin;Hahn, Song-Yop;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1397-1404
    • /
    • 2007
  • It is important to measure the resistive component separately from the total leakage current at power distribution line. It is because electric disasters such as electric shock and fire are caused mainly by the resistive component of the total leakage current. In this paper, a new theory for measuring the resistive component separately from the total leakage current is suggested, and is embodied to an actual circuit using operational amplifiers, analog switch and R-C low pass filter. Through experiments for various cases containing both the resistive and capacitive leakage currents, the suggested algorithm is confirmed to be able to measure the resistive leakage current within 4.1% of error even when the capacitive leakage current is much bigger than the resistive one. The suggested method is expected to lower the total cost because it can be realized using simple and cheap devices, and implies the measuring time can be possibly reduced because the resistive leakage current is computed exactly from the signals during only a half period of power voltage.

A Study on the Equivalent Model of an External Electrode Fluorescent Lamp Based on Equivalent Resistance and Capacitance Variation

  • Cho, Kyu-Min;Oh, Won-Sik;Moon, Gun-Woo;Park, Mun-Soo;Lee, Sang-Gil
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 2007
  • An External Electrode Fluorescent Lamp (EEFL) has longer lifespan, higher power efficiency and higher luminance than a Cold Cathode Fluorescent Lamp (CCFL). Moreover, it is easy to drive them in parallel. Therefore, the EEFL is expected to quickly replace the CCFL in LCD backlight systems. However, the EEFL has more complex characteristics than the CCFL with a resistive component, because it has both a resistive component by plasma and a capacitive component by external electrode. In this paper, values of resistance and capacitance are measured at several power levels and at several operating frequencies. They are expressed by a numeral formula based on a linear approximation that represents the equivalent resistance and capacitance as a function of power. Then we made block diagram of the equivalent circuit model using numerical expressions. Simulation waveforms and experimental results are presented to verify the feasibility of the equivalent model.

Automatic and precise calibration of 4-channel cylindrical capacitive displacement sensor (4채널 원통형 정전용량 변위센서의 자동ㆍ정밀 검보정)

  • 김종혁;김일해;박만진;장동영;한동철;백영종
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.387-393
    • /
    • 2004
  • General purpose of cylindrical capacitive displacement sensor(CCS) is measuring run-out motion and deflection of rotor. If CCS has narrow sensing range, its sensitivity coefficients must be calibrated precisely. And x, y component of CCS output can be coupled. In this research, CCS calibration procedure is automated with automatic calibration program and PC-controlled stage. And, coupled-terms of CCS signals were removed and the errors between measured position and mapped CCS signal were reduced obviously by sensitivity matrix that linearly.

  • PDF

New Design of Cylindrical Capacitive Sensor for On-line Precision Control of AMB Spindles (자기베어링의 실시간 정밀제어를 위한 원통형 정전용량 변위센서의 새로운 설계)

  • Jeon, Soo;Ahn, Hyeong-Joon;Han, Dong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.548-553
    • /
    • 2000
  • A new design of cylindrical capacitive sensor(CCS) for the displacement measurement of precision active magnetic bearing(AMB) spindle is presented in this paper. This research is motivated by the problem that existing 4-segment CCS is still sensitive to the $3^{rd}$ harmonic component of the geometric errors of a rotor. The procedure of designing new CCS starts from the modeling and error analysis of CCS. The angular size of CCS is set up as a design parameter, and new 8-segment CCS is introduced to possess an arbitrary angular size. The optimum geometry of CCS to minimize the effect of geometric errors is determined through minimum norm approach. Experimental results with test rotors have confirmed the improvement in geometric error suppression.

  • PDF

The New Residual Current Protective Devices Operating by Resistive Leakage Current (저항성 누전전류에 의하여 동작하는 새로운 누전차단기)

  • Ham, Seung-Jin;Hahn, Song-Yop;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

A Method to Monitor Vacuum Degree Using Capacitive Partial Discharge Coupler

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Yi, Sang-Hwa;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.959-964
    • /
    • 2012
  • Internal pressure of vacuum interrupter (VI) is one of the most important parameters in VI operation and may increase due to the outgassing from the materials inside VI or gas permeation through metal flange or ceramic vessel. The increase of the pressure above a certain level leads to the failures of switching or insulation. Therefore, an effective pressure check of VI is essential and an analysis of partial discharge (PD) characteristics is an effective monitoring method to identify the degree of the internal pressure of VI. This paper introduces a research work on monitoring the internal pressure of VI by analyzing PDs which were measured using a capacitive PD coupler. The authors have developed cost effective capacitive coupler based on the ceramic material that has an excellent insulation properties and the main component of the capacitive coupler is made by SrTiO3. Detectable internal pressure range and distinguishability of the internal pressure of VI were investigated. From the PD tests results, the internal pressure range, from $10^{-2}$ torr to 500 torr, can be monitored by PD measurements using the capacitive coupler and PD inception voltage (PDIV) follows the Paschen's law. In addition, rise time of PD pulse at 13.2kV decreases with the increase of the internal pressure of VI.

Dynamic Response of Organic Right-emitting Diodes in ITO/Alq3 Structure

  • Lee, Dong-Gyu;Lee, Joon-Ung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.3
    • /
    • pp.97-100
    • /
    • 2005
  • Dynamic response of organic light-emitting diodes were analyzed in $ITO/Alq_3$(100 nm)/Al device structure with a variation of voltage an frequency. At low frequency region, complex impedance is mostly governed by resistive component, and at high frequency region by capacitive component. Also, we have evaluated resistance, capacitance and permittivity of devices.

On-line Cutting Force Estimation by N[ensuring Spindle Displacement in High-Speed Milling Process (고속 밀링 가공 시 주축 변위 측정을 통한 절삭력의 실시간 감시)

  • Kim J.H.;Kim J.H.;Kim I.H.;Ahn H.J.;Jang D.Y.;Han D.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.133-134
    • /
    • 2006
  • A cylindrical capacitive displacement sensor (CCS) was developed and applied for monitoring end milling processes. Dynamic characteristics of a spindle-assembly were measured using the CCS and a designed magnetic exciter. The technique to extract the spindle displacement component caused only by cutting from the measured signals using the CCS was proposed in the paper. Using CCS signals and FRF (Frequency Response Function) derived from dynamics of the spindle tool system, dynamic cutting forces are estimated quantitatively.