• 제목/요약/키워드: capacitive application

검색결과 103건 처리시간 0.02초

집중 소자를 이용한 표면 탄성파 장치 기반의 용량 성 센서 보정 및 이를 이용한 초정밀 간극 측정 (Calibration of SAW Based Capacitive Sensor Using Lumped Component and High Precision Gap Measurement)

  • 김재근;고병한;박영필;박노철
    • 정보저장시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.16-21
    • /
    • 2012
  • SAW device is widely used as filters, sensors, actuators in various technologies. And capacitive sensor is tremendously used to measure pressure, gap, etc. The application of SAW device as signal conditioner of capacitive sensor reduces noise level and enables high precision measurement. The response increase of SAW based capacitive sensor is produced just before the two capacitive electrode contacts by the existence of parasitic resistance of capacitive electrode. In this paper, we analyze the effects of parasitic resistance and propose the calibrating method using lumped component and execute the high precision gap measurement using calibrated system. And xx nm resolution and yy ${\mu}m$ stroke was attained.

정전용량 프로브 크기에 대한 엔진오일 상대 유전율 측정 (Measurement Of The Engine Oil Relative Dielectric Constant With Respect To Capacitive Prove Dimension)

  • 김기훈;김영주
    • Tribology and Lubricants
    • /
    • 제27권4호
    • /
    • pp.209-212
    • /
    • 2011
  • The capacitive application(prove) can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents that we designed the analysis system of engine oil permittivity to know the relation between the engine oil deterioration and the prove dimension. Each of the dimension of capacitive prove is changed and then electric capacity is measured by LCR {Inductance(L), Capacitance (C), and Resistance (R)} meter. The engine oil permittivity has extracted in the prove measurement. As the additional research, this paper suggest the best of the prove dimension for the permittivity measurement.

MMIC상에서 주기적으로 배치된 용량성 소자를 이용한 단파장 전송선로 (A Short Wavelength Transmission Line Employing Periodically Arrayed Capacitive Devices on MMIC)

  • 정장현;강석엽;윤영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.840-845
    • /
    • 2010
  • 본 논문에서는 MMIC상에서 온칩용 수동소자 제작을 위해서, 주기적으로 배치된 용량성 소자를 이용한 단파장 전송선로를 제안하였다. 제안된 PACD(periodically arrayed capacitive devices) 선로 구조는 기존의 마이크로스트립 선로에 비해 매우 짧은 선로파장 특성을 보였다. PACD 선로 구조는 주파수 5GHz에서 기존의 마이크로스트립 선로 파장의 8%의 파장단축 효과를 보였고, PPGM구조의 선로 파장의 38%의 파장단축 효과를 나타내었다. 이러한 PACD선로 구조는 MMIC상에서 온칩용 수동소자 제작에 유용한 특성으로 판단된다.

RF Characteristics of Open Stubs on PES Substrate for Application to Capacitive Matching Components on Flexible MMIC

  • Yun, Young;Jeong, Jang-Hyeon;Kim, Hong-Seung;Jang, Nak-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권3호
    • /
    • pp.142-145
    • /
    • 2015
  • In this work, open stubs were fabricated on a polyether sulfone (PES) substrate, and their basic radio frequency (RF) characteristics were investigated for application to RF matching components of a flexible monolithic microwave integrated circuit (MMIC). According to the results, an open stub employing coplanar waveguide (OSCPW) on PES exhibited much lower loss than that on silicon substrate. The OSCPW with a length of $500{\mu}m$ on PES showed capacitance values of 0.031 ~ 0.044 pF from 0.5 to 50 GHz. For application to a relatively high-value capacitive matching, an open stub employing a fishbone-type transmission line (OSFTTL) was fabricated on PES, and its characteristics were investigated. The OSFTTL showed much higher capacitance values than the OSCPW due to the high effective permittivity value. Specifically, the OSFTTL on PES showed capacitance values of 0.066 ~ 0.24 pF from 0.5 to 50 GHz, which are higher than those for the open stub on silicon substrate. The above results indicate that the OSCPW and OSFTTL on PES can be effectively used for application to low/high-value capacitive matching components on microwave and millimeter wave flexible MMIC. To the best of the authors' knowledge, this work is the first report of the investigation of RF capacitive matching components on PES substrate.

Design of a Short/Open-Ended Slot Antenna with Capacitive Coupling Feed Strips for Hepta-Band Mobile Application

  • Keum, Kyoseung;Piao, Haiyan;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • 제18권1호
    • /
    • pp.46-51
    • /
    • 2018
  • In this paper, a planar printed hybrid short/open-ended slot antenna with capacitive coupling feed strips is proposed for hepta-band mobile applications. The proposed antenna is comprised of a slotted ground plane on the top plane and two capacitive coupling feed strips with a chip inductor on the bottom plane. At the low frequency band, the short-ended long slot fed by strip 1 generates its half-wavelength resonance mode, whereas the T-shaped open ended slot fed by strip 2 generates its quarter-wavelength resonance mode for the high frequency band. The antenna provides a wide bandwidth covering GSM850/GSM900/DCS/PCS/UMTS/LTE2300/LTE2500 operation bands. Moreover, the antenna occupies a small volume of $15mm{\times}50mm{\times}1mm$. The operating principle of the proposed antenna and the simulation/measurement results are presented and discussed.

전기용량성 섬유 압력센서를 이용한 호흡측정 시스템 (Respiration Measurement System using Textile Capacitive Pressure Sensor)

  • 민세동;윤용현;이충근;신항식;조하경;황선철;이명호
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.58-63
    • /
    • 2010
  • In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are presented. Belt typed textile capacitive pressure sensor has been developed for this measurement system. the distance change of two plates by the pressure of motion has been used for the respiration measurement in chest area. Respiration rates measured with the textile capacitive pressure sensor was compared with standard techniques on 8 human subjects. Accurate measurement of respiration rate with developed sensor system is shown. The data from the method comparison study is used to confirm theoretical estimates of change in capacitance by the distance change. The current version of respiratory rate detection system using textile capacitive pressure sensor can successfully measure respiration rate. It showed upper limit agreement of $3.7997{\times}10^{-7}$ RPM, and lower limit of agreement of $-3.8428{\times}10^{-7}$ RPM in Bland-Altman plot. From all subject, high correlation were shown(p<0.0001). The proposed measurement method could be used to monitor unconscious persons, avoiding the need to apply electrodes to the directly skin or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the rate-finding, broadening the potential application areas of this technology.

MMIC 상에서 초소형 무선 통신 시스템에의 응용을 위한 반전된 형태의 주기적 용량성 구조를 이용한 전송선로의 RF 특성에 관한 연구 (A Study on RF Characteristics of Transmission Line Employing Inverted Periodically Arrayed Capacitive Devices for Application to Highly Miniaturized Wireless Communication system on MMIC)

  • 김정훈;정장현;윤영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권1호
    • /
    • pp.52-57
    • /
    • 2015
  • 본 논문에서는 MMIC(Monolithic microwave integrated circuit) 상에서 초소형 무선 통신 시스템에서의 응용을 위해 반전된 형태의 주기적으로 배치된 용량성 소자를 이용한 전송선로(IPACD, Inverted Periodically Arrayed Capacitive Devices)의 RF 특성을 연구하였다. 측정 결과, 본 논문에서 제안하는 반전된 형태의 주기적으로 배치된 용량성 소자를 이용한 전송선로는 기존의 마이크로스트립 전송선로는 선로파장의 11.85%로 단파장의 성능을 보였고, 전파상수, 유효 유전율은 기존의 전송선로에 비하여 훨씬 높은 결과를 보여주었다. PACD(periodically arrayed capacitive devices) 선로구조에 비해 삽입손실이 1~10 GHz에서 22.6%정도 개선되었다. 또한 IPACD 선로구조의 등가회로를 closed-form 방정식을 통하여 이론적으로 해석하였으며, 실질적인 대역폭의 의미를 가지는 1차 통과대역에서의 차단 주파수는 129.2 GHz로 나타나 광대역의 특성을 보여주었다.

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.