• 제목/요약/키워드: canal preparation

검색결과 180건 처리시간 0.026초

하악 대구치 근심치근의 근관 형성방법에 따른 각 부위별 근관벽 후경 및 근관 면적의 변화에 관한 연구 (STUDY OF THE CHANGES IN CANAL WALL THICKNESS AND THE AREA OF THE CROSS SECTION OF THE ROOT IN THE MESIAL ROOT OF THE MANDIBULAR MOLAR CANAL PREPARATION)

  • 박종관;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.73-84
    • /
    • 1994
  • Using a model system that can compare the before and after of canal preparation in the same tooth, we measured the area of the cross section, and canal wall thickness of the distal portion of the mesial root of the mandibular molar, and compared the amount of reduction in the canal using hand flared preparation the Gates-Glidden drill flared preparation according to the changes in the MAF. The results were as follows. 1. After canal preparation, the canal wall thickness had no significant difference between the hand flared preparation and Gates-Glidden drill flared preparation. 2. The canal wall thickness, after canal preparation, there was no significant difference between the sizes of the MAF. 3. The area variation range of each cross section of root had no significant difference between MAF size and methods of canal preparation. 4. After canal preparation, the frequency of the canal wall thickness under 0.5mm showed 3.5mm below the furcation to be the most frequent with statistical significance(p<0.05). 2mm below the furcation and 5mm below the furcation followed but there was no statistical significance. 5. The danger zone of the mesial root of the mandibular molar seems to be around 3.5mm.

  • PDF

수동(手動)리머와 전동(電動)리머의 근관형성효과(根管形成效果) (EFFICACY OF HAND REAMER AND ENGINE REAMER TO PREPARE ROOT CANAL)

  • 김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.55-62
    • /
    • 1984
  • This experimental study was made to evaluate the efficacy of root canal preparation of engine reamer versus hand reamer. Eighty extracted human teeth were prepared with the following treatments and devided into 4 groups; Group 1: Canal preparation with hand reamer, and irrigation with normal saline solution. Group 2: Canal preparation with engine reamer, and irrigation with normal saline solution. Group 3: Canal preparation with hand reamer, and irrigation with 3% hydrogen peroxide and 3.5% sodium hypochlorite solution. Group 4: Canal preparation with engine reamer, and irrigation with 3% hydrogen peroxide and irrigation with 3% hydrogen peroxide and 3.5% sodium hypochlorite solution. After decalcification, 5p. sections at levels 1-, 3-, and 5-mm from the apex were evaluated microscopically. The results were as follows; The effectiveness of hand reamer and engine reamer were equal in preparing the root canal at all levels from the apex, and were equal in normal saline solution groups, and 3% $H_2O_2$ and 3.5% NaOCl solution groups. Both in hand reaming groups and in engine reaming groups, some canal walls had still untouched portion, and canal irregularities and debris were still remained.

  • PDF

GT rotary file을 이용한 만곡 근관형성시 작업 효율 및 file 변형 발생에 관한 연구 (A STUDY OF WORKING EFFICIENCY AND FILE DEFORMATION OF GT ROTARY FILE IN CURVED CANALS)

  • 신주희;백승호;배광식;임성삼;윤수한;김병현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.418-435
    • /
    • 2001
  • Root canal preparation process is of utmost importance in successful treatment of root canal. Also, one of the most important purpose of the root canal preparation is to enlarge the root canal three dimensionally without changing the curvature of the root canal However as the curvature of the root canal increases, there are many difficulties involved in formation of optimum root canal. Therefore in order to solve the above mentioned problems, new developments in methods of root canal preparation and equipments for such purposes were made. Recently, vigorous studies about newly introduced engine-driven nickel-ti-tanium rotary file are conducted. As shown in research results to dates, it is well established that the use of nickel-titanium file is better suited for curved root canal than stainless steel file in maintaining the curvature or root canal and reducing the deformation of root canal. However it is also acknowledged that there are a few discrepancies in research results according to protocol, due to failure to remove variables in experiments. In addition, although it is recommended by the manufacturer that the GT rotary file should maintain a low rotational speed of 150~350rpm and 'light pressure' as light as not to break the lead of a pencil, academic studies about the vertical force which is not yet standardized are not sufficiently explored. Therefore, this research devised and utilized a special research equipment to standardize the appropriate range of vertical force for GT rotary file through experiments by breaking of the lead of a pencil as expressed by the manufacturer and to accurately measure factors involved through repeating and recreating the environment of root canal preparation. Forming nine experimental groups by varying the vertical forces (150g. 220g, 300g) and rpm (150rpm, 250rpm, 350rpm), the effects of changing vertical forces and rpm on working efficiency were measured in terms of time expended in root canal preparation by crown-down method using a transparent resin block with 35 degree curvature and GT rotary file (z-test). The following research using this special research equipment that involved nine experimental groups and varying the vertical force for root canal preparation from 300g which is within the normal vertical force range to 700g and 1000g which fall outside the normal rpm range. The results were as follows : 1. Analysis of the experiment results revealed that the time spent in root canal preparation decreased as the vertical forces and rpm increased (p<0.05). Also, the effects of rpm were greater than those of the vertical forces within the normal vertical force range ($\beta$-weight test). 2. Observation of the deformation of GT rotary file revealed that deformation increases in a direct correlation with the vertical force increase and in a reverse correlation with the rpm decrease. In the case of the vertical forces close to the normal range, the probability of GT rotary file deformation were quite different depending on the rpm changes. In the case of greater vertical forces, the occurrences of deformation of the file were more frequent regardless of the rpm changes. 3. Deformation and breakage of file were also commonly observed in the expended time measurement experiments and GT rotary file deformation experiments in which low speed rpm (150rpm) was used and at the curved portion of the resin block.

  • PDF

Comparison of root canal preparation by three Ni-Ti instruments

  • Shibutani, Takuya;Ozaki, Kazumi;Matsuo, Takashi
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.547-547
    • /
    • 2003
  • The aim of this study was to compare the effects of three Ni-Ti instruments on leaning ability by evaluating the volumetric and morphological changes in the apical 6mm of the root canals before and after preparation, using three-dimensionally reconstructed root canals of extracted human teeth. Forty-five teeth were used in this study. They were opened the chambers and removed the all pulp remnants ultrasonically. Subsequently, the canal wall was coated with silver paste and prepared using ProTaper, ProFile and GT rotary files according to the manufacturers instructions. Before and after root canal preparation, all the specimens were scanned with micro computed tomography and examined the differences in dentine volume removed, canal straightening, the proportion of the unchanged area and canal transportation. Quantitative analysis revealed that instrumentation increased in canal volume ranging between 0.081 and $1.866{\;}\textrm{mm}^3$. On average, the large apical preparation produced by ProTaper demonstrated smaller proportions of unchanged surface areas compared to the two other instruments in small canals. But in large canals like maxillary central incisor, the preparation of ProTaper instruments was not enough. ProTaper instrument was tended to increase more in canal volume as compared with the other two instruments but unchanged area was no significant difference. These results showed that three instruments had similar preparation ability and micro computed tomography in combination with the coated wall of root canal using silver paste is a nondestructive and valuable tool to study root canal geometry and changes after preparations in detail.

  • PDF

Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

  • Yared, Ghassan
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.85-90
    • /
    • 2015
  • This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickeltitanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy. It also allows achieving predictable results in canal negotiation and glide path creation in challenging canals without the risk of instrument fracture.

근관형성방법(根管形成方法)에 따른 모의근관형태(模擬根管形態)의 변화(變化)에 대(對)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE MORPHOLOGIC CHANGES OF DIFFERENT SIMULATED CANALS ACCORDING TO THE PREPARATION METHOD)

  • 황호길;조재오;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.161-171
    • /
    • 1988
  • The purpose of this study was to examine the morphological changes of different simulated canals according to the preparation procedures. With the use of clear casting resin, simulated straight and curved canals were created so that canal preparation procedures could be directly visualized and compared. Thirty clear polyester casting resin blocks which contained four simulated canals divided into three groups; Group A($0^{\circ}$), Group B($15^{\circ}$), and Group C($30^{\circ}$). In each block, 3 canals were prepared different preparation techniques, which were conventional method, step-back method, and giromatic filing. But, one canal was not prepared as a control group. The results were as follows: 1. There was no difference on canal shape among three canal preparation methods in straight canals (Group A). 2. When conventional method and Giromatic filing were used in curved canals (Group B, C), elbow, zip and hour-glass shape were formed in apical third. 3. When conventional method and Giromatic filing were used in curved canals (Group B, C), tear-drop appearance developed at the site of the canal exit in curved canals. 4. In curved canals (Group B, C), file tend to straighten within the canal. 5. There was no difference on canal shape according to curved angle in step-back method (p > 0.1). But there was significant difference on canal shape according to curved angle in conventional method and Giromatic filing (p < 0.001). 6. Step-back method was significantly more effective than conventional method and Giromatic preparation in morphologic aspects of apical third of original canals.

  • PDF

미생물의 근관내 상아질 부착에 대한 주사전자현미경적 연구 (SEM STUDY ON THE BACTERIAL ADHESION TO THE DENTIN OF THE ROOT CANAL)

  • 정상균;오태석;배광식
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.116-122
    • /
    • 2000
  • On the instrumented root canal wall, amorphous, irregular smear layer can be observed with Scanning Electron Microscope(SEM). The purpose of this study was to evaluate the effect of the presence or absence of smear layer on the adhesion of Staphylococcus aureus to the dentin of the root canal. Human incisors, extracted within 7 days, with no caries, no fracture, no calcification of canal, were selected. After cutting crown portion at cemento-enamel junction, root canal preparation was done by modified crown-down technique using Profile and Gates - Glidden Drill. During canal preparation, 10ml physiologic saline solution(group1&3) or 10ml 3.5% NaOCl(group2&4) was used as irrigation solution. And 10ml physiologic saline solution(group1&3) or 10ml 0.5M EDTA(group2&4) was applicated for final flush. After vertical sectioning and ethylene oxide gas sterilization, samples(group1&2) were immersed into BHIYHM broth inoculated with Staphylococcus aureus (ATCC 31153) and incubated for 3hrs at $37^{\circ}C$. All samples were prepared for and observed with SEM(JEOL JSM840S). The data were analyzed by Mann-Whitney rank sum test. The conclusions are as follows ; 1. Smear layer covers entire root canal surface after root canal preparation. 2. Smear layer has been removed away and the entrances of dentinal tubules have opened widely, when applying 0.5M EDTA and 3.5% NaOCl. 3. A significantly higher number of bacteria were adhered to the root canal dentin without smear layer(p<0.0001). 4. Smear layer produced during root canal preparation impedes bacterial adhesion and colonization to dentin matrix, therefore inhibits canal reinfection.

  • PDF

음파 및 초음파기구를 이용한 근관형성법의 효율성에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFICACY OF SONIC AND ULTRASONIC ROOT CANAL PREPARATION TECHNIQUES)

  • 김한욱;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.79-89
    • /
    • 1988
  • The purpose of this study was to evaluate the canal preparation time, deviation of the apex (Zipping), and debridement effect of the canal of three canal preparation techniques. Thirty extracted 1st and 2nd molars were divided into 3 groups and each group was enlarged by ultrasonic, sonic or hand instrument. The specimens were examined under scanning electron microscope and light microscope. The results were as follows: 1. In the canal preparation time, ultrasonic group was the shortest, followed by sonic, hand group. All pairs of groups were significantly different at the 0.05 level. (P < 0.05) 2. In the deviation of the canal, no two groups were significantly different at the 0.05 level. (P > 0.05) 3. In the evaluation of debris scores, ultrasonic and sonic groups were better debridement effect than hand group in the fine canals. In the large canals, ultrasonic group was the best results, followed by sonic, hand group. 4. In the evaluation of smear layer scores, ultrasonic group was the best and sonic and hand group were same effect in the fine canals. In the large canals, three groups were same effect. 5. In the effect of the removal of predentin and pulpal debris, in the regardless of canal size, three groups were same and pulpal debris was not completely removed by either technique.

  • PDF

역행충전시 수복재와 와동 형태에 따른 변연누출의 정량적 분석 (QUANTITATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS RETROGRADE FILLING MATERIALS AND PREPARATION TYPES)

  • 한충경;양홍서
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.97-105
    • /
    • 1990
  • When conventional root canal treatment is failed or contraindicated, retrograde root canal filling following apicoectomy is a valuable procedure, aimed at hermetically sealing the root canal against leakage of irritants from the canal into the periapical tissue. In this in vitro investigation, to analyze apical microleakage electrochemically in teeth with different retrograde filling materials and preparation types, single - rooted tooth was cut 2mm from the apex and each Class I and Slot preparation was prepared. Experimental groups : Group 1. Amalgam filling with cavity varnish in Class I preparation Group 2. Scotchbond 2+Silux filling in Class I preparation Group 3. Gutta percha filling with ZOE cement in Class I preparation Group 4. Amalgam filling with cavity varnish in Slot preparation Group 5. Scotchbond 2+Silux filling in Slot preparation Each specimens was immersed in 1% solution of KCl, and applied a potential of 9V external power supply. Measurements of the current flow were obtained at 1, 2, 3, 7, 9, 12, 14, 18, 21, 25 and 28 day after immerson. Marginal microleakage were compared and evaluated. The results were as follows ; 1. The group filled with composite resin with dentin bonding agent shows lower apical microleakage value than the group filled with amalgam following varnish application (P<0.01). 2. In the group filled with gutta percha, apical microleakage value was the hightest 3. There was no significant difference between Class I cavity and Slot type cavity regardless of the used materials.

  • PDF

만곡 근관 형성시 니켈-티타늄 파일의 만곡 유지 능력과 그에 대한 유한요소법적 분석 (ABILITY OF NICKEL-TITANIUM FILES IN MAINTAINING THE ORIGINAL CURVATURE OF A CURVED ROOT CANAL AND ITS ANALYSIS BY FINITE ELEMENT METHODS)

  • 박한수;임성삼;배광식;윤수한
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.220-227
    • /
    • 1997
  • The purpose of our study is to evaluate the ability of nickel-titanium(NiTi) files in maintaining the original curvature of a curved root canal during canal preparation. Curved canals on translucent resin blocks were prepared with NiTi and stainless steel files, and they were placed at the platform which can reproduce the same position. The unprepared and prepared canal forms were accurately compared by double exposure technique of photography. By finite element methods we also analyzed stress distributions of NiTi and stainless steel files in a curved canal. The results were as follows : 1. NiTi files were excellent in maintaining the original curvature of a curved canal than stainless steel files after canal preparation. 2. The results of canal preparation with these files were well verified by the analysis of stress distributions using finite element methods.

  • PDF