• 제목/요약/키워드: camera

검색결과 10,569건 처리시간 0.04초

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구 (Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer)

  • 송흥권;권경태;박철수;양오남;김민수;김정만
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.125-131
    • /
    • 2005
  • 목 적 : 폐암 환자 중 호흡에 의한 종양의 움직임이 큰 폐 하엽에서 정위적 방사선수술 시 호흡에 의한 종양의 움직임을 감소시키는 방법으로 종양의 움직임이 적은 호흡 주기에서만 방사선을 조사할 수 있는 respiratory gating system을 사용함으로써 그 유용성에 대하여 알아보고자 한다. 대상 및 방법 : 폐 하엽의 정위적 방사선 수술 환자 2명을 대상으로 하였으며, 환자의 복부에 maker block (sensor)을 부착하고 tracking camera와 Real Time Position Management (RPM)를 이용하여 호흡 주기를 측정하면서 1회 호흡주기에서 10 phases로 4D-CT를 촬영하였다. 종양의 위치 변화가 급격하지 않은 호흡주기 (%)의 phases를 치료 phases로 결정하였고, 치료 phases의 CT image를 Maximum Intensity Projection (MIP) 기법으로 재구성 후 volume contouring을 하였다. Set up의 재현성 및 GTV의 위치 변화를 확인하기 위해 치료 전과 치료 중 2회의 4D-CT 촬영을 하였다. 결 과 : GTV의 움직임이 가장 큰 Y(longitudinal)축에서 A환자는 전체 호흡주기($0{\sim}90%$)에서 9.4 mm가 치료 호흡 주기 범위 ($30{\sim}60%$)에서는 2.6 mm로, B환자는 전체 호흡주기 ($0{\sim}90%$)에서 11.7 mm가 치료 호흡주기의 범위($30{\sim}70%$)에서는 2.3 mm로 감소하였다. 2회의 4D-CT 비교 결과 set up의 X, Y, Z축 오차는 모두 3 mm이내였다. 결 론 : 호흡에 의한 종양의 움직임이 큰 폐 하엽에서 정위적 방사선수술 시행 시 respiratory gating system의 사용은 종양의 움직임을 5 mm이내로 감소시킬 수 있어 유용하였다.

  • PDF

RTK-GPS 무인항공사진측량의 위치결정 정확도 평가 (Assessment of Positioning Accuracy of UAV Photogrammetry based on RTK-GPS)

  • 이재원;성상민
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.63-68
    • /
    • 2018
  • 무인항공사진측량에서 지상기준점(GCP: Ground Control Point)의 설치는 시간과 비용이 가장 많이 소요되는 작업공종이다. 최근 항법센서와 통신기술의 급속한 발전으로 RTK(Real Time Kinematic) 또는 PPK(Post Processed Kinematic) 방식과 같이 지상기준점을 사용하지 않고도 무인항공사진측량이 가능한 UAV(Unmanned Aerial Vehicle) 기체가 활용되고 있다. 본 연구에서는 무기준점에 의한 RTK-UAV 측량의 잠재성을 평가하고자 지상기준점을 사용한 비 RTK(non-RTK)-UAV 측량과 비교 실험을 수행하였다. 즉 지상기준점의 수를 달리하여 비 RTK(non-RTK) 방식의 UAV와 무기준점에 의한 RTK 방식의 UAV로 동시에 촬영하여 획득된 영상으로 제작한 성과물의 위치정확도를 비교 분석하였다. 영상취득은 촬영고도 약 160m에서 Canon IXUS 127 카메라(초점거리 4.3mm, 화소크기 $1.3{\mu}m$)로 이론적인 GSD는 약 4.7cm이다. 실험결과, 비 RTK 방식에 의한 지상기준점의 수에 따른 위치정확도의 RMSE(평면/수직)는 GCP가 5개인 경우 각각 4.8cm/8.2cm, 4개인 경우 5.4cm/10.3cm, 3개인 경우 6.2cm/12.0cm로 나타났다. 그리고 비 RTK 방식의 무기준점인 경우에는 평면과 수직위치 오차의 RMSE가 각각 112.9cm, 204.6cm로 매우 크게 증가하였다. 하지만 무기준점으로 RTK 방식을 적용한 무인항공사진측량의 경우에는 평면과 수직위치 정확도가 각각 13.1cm, 15.7cm로 비 RTK 방식에 비하여 오차가 현저하게 줄어들었다. 연구결과, 무기준점으로도 정밀한 위치 결정이 가능한 RTK 방식의 무인항공사진측량은 경제성이 크게 증가하여 향후 공간정보 분야에의 활용성이 기대된다.

SURF와 RANSAC 알고리즘을 이용한 대응점 필터링 적용 파노라마 이미지 처리 (Matching Points Filtering Applied Panorama Image Processing Using SURF and RANSAC Algorithm)

  • 김정호;김대원
    • 전자공학회논문지
    • /
    • 제51권4호
    • /
    • pp.144-159
    • /
    • 2014
  • 다중의 영상을 이용하여 하나의 파노라마 영상을 제작하는 기법은 컴퓨터 비전, 컴퓨터 그래픽스 등과 같은 여러 분야에서 널리 연구되고 있다. 파노라마 영상은 하나의 카메라에서 얻을 수 있는 영상의 한계, 즉 예를 들어 화각, 화질, 정보량 등의 한계를 극복할 수 있는 좋은 방법으로서 가상현실, 로봇비전 등과 같이 광각의 영상이 요구되는 다양한 분야에서 응용될 수 있다. 파노라마 영상은 단일 영상과 비교하여 보다 큰 몰입감을 제공한다는 점에서 큰 의미를 갖는다. 현재 다양한 파노라마 영상 제작 기법들이 존재하지만, 대부분의 기법들이 공통적으로 파노라마 영상을 구성할 때 각 영상에 존재하는 특징점 및 대응점을 검출하는 방식을 사용하고 있다. 또한, 대응점을 이용한 RANSAC(RANdom SAmple Consensus) 알고리즘을 사용, Homography Matrix를 구하여 영상을 변환하는 방법을 사용한다. 본 논문에서 사용한 SURF(Speeded Up Robust Features) 알고리즘은 영상의 특징점을 검출할 때 영상의 흑백정보와 지역 공간 정보를 활용하는데, 영상의 크기 변화와 시점 검출에 강하며 SIFT(Scale Invariant Features Transform) 알고리즘에 비해 속도가 빠르다는 장점이 있어서 널리 사용되고 있다. SURF 알고리즘은 대응점 검출 시 잘못된 대응점을 검출하는 경우가 생긴다는 단점이 존재하는데 이는 RANSAC 알고리즘의 수행속도를 늦추며, 그로인해 CPU 사용 점유율을 높이기도 한다. 대응점 검출 오류는 파노라마 영상의 정확성 및 선명성을 떨어뜨리는 핵심 요인이 된다. 본 논문에서는 이러한 대응점 검출의 오류를 최소화하기 위하여 대응점 좌표 주변 $3{\times}3$ 영역의 RGB값을 사용하여 잘못된 대응점들을 제거하는 중간 필터링 과정을 수행하고, 문제해결을 시도하는 동시에 파노라마 이미지구성 처리 속도 및 CPU 사용 점유율 등의 성능 향상 결과와 추출된 대응점 감소율, 정확도 등과 관련한 분석 및 평가 결과를 제시하였다.

고등학교 천체 관측 동아리를 위한 방과 후 학교 프로그램 개발 및 적용: 관측지 주변 환경을 고려한 표준화 계수 결정 프로그램 (Development and Application of an After-school Program for an Astronomy Observation Club in a Highschool: Standardized Coefficient Decision Program in Consideration of the Observation Site's Environment)

  • 김승환;이효녕;이현동;정재화
    • 한국지구과학회지
    • /
    • 제29권6호
    • /
    • pp.495-505
    • /
    • 2008
  • 이 연구의 목적은 방과 후 학교 활동으로 직접 활용될 수 있는 고등학교 천체관측반을 대상으로 한 천체 관측 프로그램 개발 및 적용이다. 연구방법은 먼저 현행 지구과학교과서의 천문관련 탐구활동을 분석한 다음, 가장 기본적인 관측 장비의 표준화 프로그램을 개발하였으며, 프로그램을 이용하여 학교 인근 여러 관측지에서 학생들이 직접 탐구활동을 수행하였다. 특히 관측 장비의 경우 일선학교에서도 쉽게 구비할 수 있는 102mm급 굴절망원경과 디지털카메라를 이용하였으며, 대부분 도심지에 위치한 학교의 관측지 환경을 고려한 탐구활동 및 그 수행을 위한 컴퓨터 프로그램을 개발하였다. 이 연구의 결과는 다음과 같다. 첫째, 현행 교육과정상의 천문관련 탐구활동은 대부분 제시된 자료를 분석하는 자료 해석이나 가상실험활동으로 구성되어 있다. 둘째, 대부분의 학교가 위치한 도심지의 경우 도시 외곽보다 관측 환경이 열악하다. 셋째, 학교 인근 도심지에서 보편화된 관측 장비를 이용한 효율적인 관측 기법과 도심지에서의 관측 기기의 표준화 계수를 결정하였다. 넷째, 이와 같은 일련의 과정을 프로그램화하여 측정한 결과, 도시와 도시외곽에서 실제 별의 등급과 큰 차이를 보이지 않았으며, 학습 프로그램 개발을 통하여 천체 관측에 관한 다양한 탐구 활동을 제공할 수 있었다 현재 천체 관련 교육은 실제 탐구 활동 영역이 결여되어 있으며, 대부분의 학교가 도심지에 위치하고 있어서 관측환경 또한 좋지 못하다. 하지만 이 프로그램을 이용하면 실질적인 천체관측 활동과 관측 결과에 대해 정형화된 보정활동을 거쳐 유의미한 관측 데이터를 수집할 수 있으며, 이를 여러 가지 활동을 통해 재해석 할 수 있다. 이를 통해 현장 체험 중심의 천체 탐구 활동을 활성화시킬 수 있으며, 과학적 흥미를 높일 수 있다.

IGRINS Design and Performance Report

  • Park, Chan;Jaffe, Daniel T.;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Yu, Young Sam;Kaplan, Kyle;Mace, Gregory;Kim, Hwihyun;Lee, Jae-Joon;Hwang, Narae;Kang, Wonseok;Park, Byeong-Gon
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.90-90
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is the first astronomical spectrograph that uses a silicon immersion grating as its dispersive element. IGRINS fully covers the H and K band atmospheric transmission windows in a single exposure. It is a compact high-resolution cross-dispersion spectrometer whose resolving power R is 40,000. An individual volume phase holographic grating serves as a secondary dispersing element for each of the H and K spectrograph arms. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{{\prime}{\prime}}{\times}15^{{\prime}{\prime}}$. IGRINS has a plate scale of 0.27" pixel-1 on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with a SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized ($0.96m{\times}0.6m{\times}0.38m$) rectangular Dewar. The fabrication and assembly of the optical and mechanical components were completed in 2013. From January to July of this year, we completed the system optical alignment and carried out commissioning observations on three runs to improve the efficiency of the instrument software and hardware. We describe the major design characteristics of the instrument including the system requirements and the technical strategy to meet them. We also present the instrumental performance test results derived from the commissioning runs at the McDonald Observatory.

  • PDF

전신 정위 고정장치 제작과 임상효과에 대한 연구 (The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.30-38
    • /
    • 2004
  • 목적: 방사선 치료 시 환자의 움직임을 최대한 고정시켜 줄 수 있으며 환자 자세에 대한 Setup 오차를 감소시키고 환자 전신에 산재한 병소를 위치화하고 좌표화할 수 있는 전신 정위 고정장치 제작과 제작한 고정장치에 대한 고정효과 및 재현성을 나타내는 환자 자세의 Setup 오차를 평가하였다. 대상 및 방법: 자체 제작한 고정장치는 크게 기본판(base plate)과 고정틀(Immobilizer), Vacuum cushion, 벨트로 이루어진다. 기본판은 50${\times}$130${\times}$1 ㎤ 베크라이트로 고정틀은 견고한 아세탈 재질을 사용하여 제작하였다. 초기의 Lax frame의 경우, side panel에 부착되어 있는 좌표계(coordinates)를 기본판 바닥에 radiopaque catheter wire를 사용하여 N 타입으로 새겨서 넣어 위치측정이 가능한 좌표계로 적용할 수 있도록 하였다. 제작된 고정장치에 대한 성능실험으로 방사선 투과율 측정 실험과 가상표적을 부착한 지원 환자를 대상으로 표적에 대한 위치측정실험이 수행되었다. 그리고 CCTV 카메라와 Digital Video Recorder (DVR)를 이용하여 획득된 환자 영상을 Matlab 프로그램으로 환자 자세에 대한 Setup 오차를 분석하였다. 결과: 전신 정위 고정장치는 CT 촬영과 방사선치료 시 사용 가능성에 중점을 두고 제작되었다. 이 고정장치의 구조는 갠트리의 회전각의 변화에 따라 충돌하지 않게 제작되었고 측면으로 경사지게 입사되는 빔의 투과율을 최대화할 수 있게 제작되었다. 고정틀의 고정효과를 높여주는 고정벨트는 입사된 빔의 방향에 방해되지 않게 제작되었다. 고정장치에 대한 방사선 투과율은 10과 21 MV의 에너지에서 95, 95%로 측정되었고 지원 환자에 부착한 가상 표적의 위치는 CT 촬영으로 파악할 수 있었다. Matlab 프로그램으로 분석한 setup 오차는 흉부의 측면과 중심부위에서 3.69$\pm$1.60, 2.14$\pm$0.78 mm이고 복부의 측면과 중심부위에서 7.11$\pm$2.10, 6.54$\pm$2.22 mm이며 여자 환자 경우, 가슴 측면의 Setup 오차는 6.33$\pm$1.55 mm으로 측정되었다. 결론: 전신 정위 고정장치의 제작과 실험을 통해 extra-cranial 암에 대한 방사선수술에서 매우 실용적이고 유용하게 사용될 것으로 사료되며 표적 위치 결정과 환자 고정 도구로서 사용될 것이다. 더 많은 환자 치료자세의 Setup 오차 측정이 수행되면 정확한 환자의 Setup 오차의 결과를 향상시킬 수 있을 것으로 기대된다.

  • PDF

방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성 (The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 방사선 치료과정에서 가장 중요한 것은 환자에게 조사된 흡수선량을 검증하는 것이다. IMRT에 사용되는 방사선의 물리적 특성을 결정하고 환자에 조사된 선량분포를 검증할 수 있는 정밀한 선량 측정 장치가 필요하다. 본 연구에서 2차원 광자선의 선량검증을 위해 만들어진 BInS (Beam Intensity Scanner)에 관하여 논의한다. BInS에 있는 Scintillator는 광자선이나 전자선에 조사되면 형광을 발생하는 Gd$_2$O$_2$S:Tb를 주성분으로 한다. Scintillator에서 발생된 형광은 디지털 비디오카메라에 의해 수집되어 디지털 신호로 바뀌고 자체 제작한 소프트웨어에 의해 분석되며 상대적인 선량 분포가 3차원 그림으로 표시된다. BInS가 IMRT에서 사용가능한지를 알아보기 위하여 치료에 관련된 몇 가지 측정을 하였다. IMRT의 주요 작동방식 중의 하나인 SMLC (static multileaf collimator) 방식에서는, leaf들의 동작을 통제하여 만들어지는 여러 개의 정적 조사면적(static portal)을 통하여 IMB (intensity modulated beam)이 만들어진다. 따라서 여러 개의 정적 조사면적이 연달아 맞닿아 있는 경우, 연속된 두 조사면적의 경계면에서 penumbra와 산란된 광자들이 겹쳐지고 따라서 hot spot이 생기게 된다. 이와 같이 SMLC 방식에서 나타나는 inter-step hot spot들의 존재를 BInS를 이용하여 측정하여 가시화하였고 또한 그것들을 제거하는 실험적 방법도 제시하였다. IMRT에서 사용되는 다른 주요한 작동방식인 DMLC (dynamic multileaf collimator)는 광자선이나 전자선을 제어하는 leaf의 작동방식이 다르기 때문에 SMLC 방식과는 다른 특성을 보인다. 따라서 BInS를 이용하여 SMLC와 DMLC 방식에 의해 실제로 target에 투사된 선량을 측정 비교하였다. 비록 같은 선량을 target 부위에 투사하기로 계획했을지라도, 실제로는 산란된 광자와 전자들 때문에 DMLC 방식에 의한 선량이 SMLC 방식에 의한 선량보다 14.8%나 큰 것으로 측정되었다.

  • PDF

양릉천-현종 전침치료가 뇌경색환자 및 정상인의 뇌혈류에 미치는 영향 - SPECT와 SPM을 이용한 연구 - (Effect of GB 34-GB 39 Electro-acupuncture on Regional Cerebral Blood Flow in Stroke Patients and Normal Volunteers Evaluated by $^{99m}Tc-ECD$ SPECT)

  • 한진안;정동원;배형섭;박성욱;정우상;박정미;고창남;조기호;김영석;김덕윤;문상관
    • 대한한의학회지
    • /
    • 제27권3호
    • /
    • pp.187-200
    • /
    • 2006
  • Objectives: Acupuncture has been applied in Asia for thousands of years, especially to rehabilitation after stroke. It has been reported that acupuncture increased cerebral blood supply and stimulated the functional activity of brain nerve cells shown by using brain imaging techniques. This study was to evaluate the effect of GB 34-GB 39 electro-acupuncture (EA) on regional cerebral blood flow (rCBF) in stroke patients and normal volunteers using single photon emission computed tomography (SPECT). Methods: The study procedure was divided into two parts: patients and volunteers studies. For the patients study, ten ischemic stroke patients (3 males, 7 females, mean age $68.5{\pm}8.9$ years old) were selected. Baseline brain SPECT was done with triple head gamma camera (MultiSPECT3, Siemens, USA) after intravenous administration of 1,110 MBq of $^{99m}Tc-ECD$. Fifteen-minute EA at GB 34 and GB 39 were applied on the affected limb. The same dose of $^{99m}Tc-ECD$ was injected during the EA, and the second set of SPECT images wasobtained. Using the computer software (ICON 7.1, Siemens, USA), 3 SPECT slices (upper, middle, lower) surrounding the brain lesion were selected and each slice was divided into 10-16 brain regions. Asymmetry indexes (AI) were analyzed in each brain region. We regarded over 10% changes of AI between before and after EA as significance. For the volunteers study, 10 healthy human volunteers (5 males, 5 females, mean age $28.1{\pm}6$ years old) were selected. In the resting state, $^{99m}Tc-ECD$ brain SPECT scans were performed. On the 7th day after the resting examination, 15 minute EA was applied at GB 34 and GB 39 on the right side of the subjects. Immediately after EA, the second SPECT images were obtained inthe same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by statistical parametric mapping with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: In stroke patients, six of the eight (75%) had significantly increased perfusion in post-acupuncture scans compared to their baseline state. In normal volunteers, GB 34-GB GB EA increased rCBF in both hemispheres including right ventral posterior cingulate (Brodmann area (BA) 23), left superior temporal, anterior transverse temporal (BA 22, 41), left parastriate, peristriate (BA 18, 19), right occipitotemporal, angular (BA 37, 39), left rostral postcentral, caudal postcentral and preparietal (BA 2, 3, 5). However GB 34-GB 39 EA decreased rCBF in the right hemisphere including triangular and middle frontal lobes. Conclusions: The results demonstrated that OB 34-GB 39 EA increased cerebral perfusion in ischemic stroke patients and increased rCBF grossly in temporal lobes of normal volunteers. It is also suggested that there may be a correlation between the GB meridian and the territory of the middle cerebral artery.

  • PDF

게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견 (Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning)

  • 안병철;서지형;배진호;정신영;박헌식;이재태;채성철;이규보
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.225-232
    • /
    • 2004
  • 목적 : 관상동맥질환을 가진 환자에서는 운동부하 후 일시적인 심근기절로 인하여 좌심실의 벽운동이상과 좌심실구혈률 감소가 발생될 수 있다. 본 연구는 운동 후 좌심실기능저하를 보이는 환자와 그렇지 않은 환자의 관상동맥조영술과 운동부하 심근관류 SPECT소견을 비교분석 하고자 하였다. 대상 및 방법 : 운동부하심전도, 관상동맥조영술 및 심근관류 SPECT를 시행한 환자 중 게이트 SPECT로 구한 좌심실구혈률이 운동 후 5%이상 감소된 36명 (기절심근군)과 운동부하 후 좌심실구혈률 변화가 1%이하인 16명 (비기절심근군)을 대상으로 하였다. 답차를 이용한 운동부하중 심전도검사를 시행하고, 최대 운동부하시 Tc-99m MIBI 740MBq을 투여한 후 이중헤드 감마카메라(Vertex Plus, ADAC)로 부하 심근관류영상을 얻었다. 심혈관조영술은 위 검사로 부터 1개월내에 시행되었다. 결과 : 기절심근군은 비기절심근군에 비해 고콜레스테롤혈증의 빈도가 유의하게 높았으며(45.5 대 7.1%, p=0.01), 당뇨병의 빈도가 높은 경향을 가졌으며, 고혈압의 빈도는 낮은 경향을 가졌으나 통계적으로 유의하지 않았다. 비기절심근군에 비해 기절심근군에서 SPECT 검사상 관류결손의 범위 (18.2% 대 9.1%, p=0.029)와 정도 (13.5 대 6.9, p=0.04)는 더 컸으며, 가역성정도 (7.9 대 4.8, p=0.09)는 더 큰 경향을 가졌으며, 운동부하심전도상 허혈양성 소견의 빈도가 높은 경향을 가졌다(82.9% 대 64.3%, p=0.095). 심혈관조영술상 중증 ($80{\sim}99%$)의 관상동맥협착의 빈도가 높은 경향을 보였으나 (64.7% 대 35.7%, p=0.064), 다혈관질환의 빈도 (62.5% 대 46.2%, p=0.279), 협착정도 (75.8% 대 66.8%, p=0.468)에는 유의한 차이가 없었다. 기절심근군 중 관류결손이 발견되지 않았던 4명 (11.1%) 모두에서 유의한 관상동맥협착이 있었고 혈관재개통술이 시행되었다. 결론 : 운동부하로 5%이상의 좌심실구혈률의 감소를 보이는 환자는 그렇지 않은 환자에 비하여 심근관류 SPECT상 관류결손 크기와 정도가 크며, 가역성이 더 높은 경향을 나타내었으며, 혈관조영술상 관상동맥협착 정도가 중증인 경향을 가지고 있으며, 비록 관류 SPECT상 결손이 없더라도 관상동맥조영술상 혈관 재개통술이 필요할 정도의 유의한 협착이 있어, 이러한 환자에서는 적극적인 진단과 치료적 개입이 필요할 것으로 생각된다.