• 제목/요약/키워드: calibrator calibration

검색결과 39건 처리시간 0.022초

전기식 온도 교정기 교정기법 연구 (A Study on the Calibration Technique of an Electrical Temperature Calibrator)

  • 오광석;이왕헌
    • 제어로봇시스템학회논문지
    • /
    • 제22권11호
    • /
    • pp.944-951
    • /
    • 2016
  • Resistance temperature detectors (RTDs) and thermocouple sensors are broadly used to measure temperatures in the engineering and research fields. The contents of this standard calibration procedure (SCP) describe procedures related to the calculation of an electrical temperature calibrator and show different ways to indicate the calibration results, such as measurement uncertainty. As an SCP for the electrical temperature calibrator has not been developed yet, we studied the SCP and found a solution to this problem. In this paper, we present a mathematical model of the data and measurement variations with the calibration data results.

온도교정기 RTD 저항 및 열전대 직류전압 교정기법 연구 (A Study on the Calibration Technique of RTD and Thermocouple System)

  • 오광석;이왕헌
    • 전기전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.439-448
    • /
    • 2016
  • 온도 측정을 위해 RTD와 열전대 센서가 산업이나 연구 분야에 널리 사용되고 있다. RTD 및 열전대의 온도 교정기에 대한 표준교정절차는 측정에서 포함되는 불확도의 교정 결과를 나타내는 방법을 보여준다. 지금까지 이들에 대한 표준교정절차가 확립되지 않아 다소의 불편함과 표준교정 업무에 어려움이 있었다. 이러한 문제를 해결하기 위해 온도 교정기의 RTD 및 열전대에 대한 교정기법을 연구하게 되었다. 본 논문에서는 이들에 대한 수학적 모델과 교정결과 자료를 제시하였다.

음향 챔버형 마이크로폰 검교정기의 검교정 주파수 한계와 모드 특성을 이용한 개선 방법에 관한 연구 (A study on calibration frequency limit of acoustic chamber type microphone calibrator and improvement method using mode shape)

  • 김차영;신금재;문원규
    • 한국음향학회지
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 2022
  • 본 논문은 마이크로폰 검교정을 위한 음향 챔버형 검교정기의 고주파 검교정 한계가 나타나는 원인을 밝히고 이를 향상시키는 방법을 제시한다. 상용 유한요소 해석 프로그램을 활용하여 고유 주파수 해석과 주파수 영역 해석을 통해 음향 챔버형 검교정기의 검교정 주파수 한계를 분석하였고, 이를 바탕으로 약 2 Hz 부터 6.4 kHz 까지 1 dB 수준 이내로 정교하게 검교정할 수 있는 음향 챔버형 검교정기를 설계 및 제작하고 실험을 통해 그 성능을 검증하였다. 본 연구를 통해 제안된 음향 챔버형 검교정기는 넓은 주파수 범위에서 다수의 마이크로폰을 동시에 검교정 할 수 있는 이점을 가지고 있어 다수의 마이크로폰을 위한 간편한 검교정에 유용하게 사용될 수 있다.

실내 모형실험을 통한 수평재하 말뚝의 거동측정을 위한 FBG 센서의 적용성 평가 (Application of FBG Sensors on a Cantilever Beam for Analyzing Behavior of Laterally Loaded Piles)

  • 이태희;정원석;정영훈;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.587-597
    • /
    • 2010
  • Analysis of the behavior of a laterally loaded pile is important in the design of critical civil structures. Recently, the electric strain gauge has been widely used to measure the strains along the pile. The electric strain gauge, due to lack of durability, is inappropriate in the use of long-term measurements. Herein, the feasibility of implementing the FBG sensor was investigated using a cantilever-type calibrator in laboratory. A special calibrating tool called "cantilever-calibrator" was used to calibrate the FBG sensors. The calibrator consists of a special calibration beam, a holding-clamp at one end of the beam, and a micrometer on the other end. Three FBG sensors were installed on the calibration beam. The strains measured by FBG sensors were compared with those calculated theoretically using cantilever beam theory. The calibration factor of FBG sensors were suggested to compensate the difference between measured and calculate strains.

  • PDF

어레이 마이크로폰용 광대역 소형 위상교정기의 설계 (Design of the broadband and compact phase-calibrator for array microphones)

  • 주형식;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1032-1035
    • /
    • 2004
  • Pressure distribution is measured by way microphones to identify noise sources in the space. For example, beam-forming method or acoustic holography use phase information to identify the source. Therefore, the phase is significant information to correctly identify the source position. However, due to the microphone characteristics and measuring systems, measured signals always have errors, which make the identification difficult. Therefore, phase calibration of microphones is needed. Duct and speaker systems are generally used as calibrators. Acoustic characteristics of the calibrator are, of course, functions of many Parameters of the system: i.e. duct size, frequency, and microphone spacing. In this paper, design parameters which effect on the performance and size of the calibrators are considered. Then the parameters would be applied to design and real product of the phase-calibrator.

  • PDF

2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구 (A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters)

  • 최종오;이완규;임기원
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

현장용 교정 장치를 이용한 3-컵 풍속계의 교정 방법 (Calibration System for Three-Cup Anemometers)

  • 전세종;이생희;최용문
    • 대한기계학회논문집B
    • /
    • 제34권3호
    • /
    • pp.325-331
    • /
    • 2010
  • 3-컵 풍속계는 자동기상측정, 환경 모니터링, 풍력 발전에 필요한 풍속을 측정하기 위해 널리 사용되고 있다. 일반적으로 3-컵 풍속계의 회전부를 지지하는 베어링은 오염물질, 진동 또는 돌풍 등의 여러 요인에 의해 마모되기 쉽고, 이로 인해 풍속에 대한 출력 특성이 장기적으로 변한다. 따라서 3-컵 풍속계를 주기적으로 교정하여 풍속에 대한 출력 특성을 유지 및 관리해야 한다. 본 연구에서는 3-컵 풍속계가 설치된 현장에서 풍속계를 교정 할 목적으로 제트 유동을 이용한 현장용 교정 장치를 제작하였다. 현장용 교정 장치가 3-컵 풍속계를 교정할 수 있는지 확인하기 위해, 현장용 교정 장치의 제트 유동 특성을 측정하였다. 현장용 교정 장치를 가지고 5 종류의 3-컵 풍속계들을 교정하였고, 풍동에서 3-컵 풍속계를 교정한 결과와 비교하였다.

정방향 스텝 동압력 교정장치 개발 (Development of Dynamic Pressure Calibrator with Positive Step Pressure)

  • 최주호;홍성수;우삼용;이경희;김창복
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.155-169
    • /
    • 2001
  • In this paper, dynamic pressure is mainly generated in the closed chamber of gun when the propellant is fired and has exponential pressure motion. Dynamic pressure calibrator with positive step pressure was designed and manufactured to meet the calibration of piezoelectric high pressure transducers which are mainly used to measure dynamic pressure motion in the test of weapon systems. In addition, the results of Performance test and analysis of system uncertainty are provided.

  • PDF

KRISS에서 수행된 음향관련 교정 및 시험 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;권휴상;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

GIS에서 UHF 부분방전 검출법의 교정방안 연구 (The Study of The Calibration Method for The UHF PD Detection in GIS)

  • 이우영;정진교;최영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2290-2292
    • /
    • 1999
  • The Ultra-High Frequency(UHF) method for detecting a partial discharge in Gas-Insulated Substation(GIS) has some advantages compared to a conventional method(IEC 270) but there is a shortage in view of a quantitative analysis. Therefore, this paper describes the implementation of a calibrator and the calibration process based on it. And its characteristics are confirmed through the experiment using the 362kV GIS chamber.

  • PDF