• Title/Summary/Keyword: calibration-free

Search Result 115, Processing Time 0.025 seconds

Sand Moisture Measurement with Microwave Technique in Free Space at X-Band Frequency (X-밴드 주파수의 마이크로파를 이용한 자유공간에서의 모래수분측정)

  • 남현수;성재용;박남석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.525-533
    • /
    • 1997
  • A nondestructive moisture measurement technique has been applied to improve the previous moisture measurement method in the building research. The experiment was done in free space using horns since it is the key element for continuous and non-destructive measurement. For this purpose a microwave bridge type analyzer at the frequency of 9.5 GHz was used to determine the moisture content of sands in the range of 1~12%. From this, the representative calibration curves were obtained. This shows that moisture measurement technique using microwave is applicabe to the measurement of moisture in non-metallic materials such as coal, pulp, foods, building materials, etc.

  • PDF

Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests (TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가)

  • Park, Hye-Mi;Yoo, Seon-Hee;Lee, Seon-Ho;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

Accuracy Improvement and Systematic Bias Analysis of Scanning White Light Interferometry for Free-form Surfaces Measurements (자유 곡면 형상 측정을 위한 백색광 주사 간섭계의 정확도 향상 및 시스템 오차 분석)

  • Ghim, Young-Sik;Davies, Angela;Rhee, Hyug-Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.7
    • /
    • pp.605-613
    • /
    • 2014
  • Scanning white-light interferometry is an important measurement option for many surfaces. However, serious profile measurement errors can be present when measuring free-form surfaces being highly curved or tilted. When the object surface slope is not zero, the object and reference rays are no longer common path and optical aberrations impact the measurement. Aberrations mainly occur at the beam splitter in the interference objective and from misalignment in the optical system. Both effects distort the white-light interference signal when the surface slope is not zero. In this paper, we describe a modified version of white-light interferometry for eliminating these measurement errors and improving the accuracy of white-light interferometry. Moreover, we report systematic errors that are caused by optical aberrations when the object is not flat, and compare our proposed method with the conventional processing algorithm using the random ball test.

Measurement of Normal Incidence Surface Impedance of Absorbing Materials Using the Improved Beamforming Method in a Free Field (자유 음장 조건에서 개선된 빔형성 방법을 이용한 흡음재의 수직 입사 표면 임피던스 측정)

  • Shin, Chang-Woo;Sun, Jong-Choen;Kang, Yeon-June;Paik, Soon-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.598-605
    • /
    • 2008
  • An improved beamforming method is proposed to measure the surface impedance of absorbing materials in a free field. It is possible to estimate the surface impedance by decomposing measured signals into incident and reflected signals by using the spatial filter matrix of the beamforming method. Wavelet do-noising techniques which reduce the white Gaussian noise are applied to improve the results. Phase calibration method is also used to improve the results of the measured surface impedance in a low frequency range. The results of the normal incidence experiments that are performed in a semi-anechoic chamber are verified by comparing with those of the standard test method that is presented in ASTM E1050. The proposed method is found to be reliable to measure the surface impedance for frequencies higher than 400 Hz.

Calibration Equation for Nacelle Anemometer Derived by LIDAR Measurements (라이다 측정을 이용한 나셀 풍속계 보정식 제안)

  • Kim, Hyun-Goo;An, Hae-Joon;Yang, Seung-Joo;Park, Woo-Jae;Kim, Seok-Woo
    • New & Renewable Energy
    • /
    • v.9 no.1
    • /
    • pp.12-16
    • /
    • 2013
  • The nacelle anemometer mounted behind the blade roots of a wind turbine measures distorted wind speed comparable with free-stream wind because of the wake effects caused dependent upon the operation of the wind turbine and the rotation of its blades. The field campaign was carried out to measure free-stream wind speed at a height identical to the height of the nacelle anemometer by deploying a ground-based remote-sensing equipment, LIDAR. It is derived that a third-order polynomial equation for correcting wind speed measured by the nacelle anemometer to undistorted free-stream wind speed incident to a wind turbine. It is anticipated that the derived correction equation enables wind speed measured by the nacelle anemometer to be used as a precise input for a wind turbine performance test and for developing an active control logic.

Multi-Range Approach of Stereo Vision for Mobile Robot Navigation in Uncertain Environments

  • Park, Kwang-Ho;Kim, Hyung-O;Baek, Moon-Yeol;Kee, Chang-Doo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1411-1422
    • /
    • 2003
  • The detection of free spaces between obstacles in a scene is a prerequisite for navigation of a mobile robot. Especially for stereo vision-based navigation, the problem of correspondence between two images is well known to be of crucial importance. This paper describes multi-range approach of area-based stereo matching for grid mapping and visual navigation in uncertain environment. Camera calibration parameters are optimized by evolutionary algorithm for successful stereo matching. To obtain reliable disparity information from both images, stereo images are to be decomposed into three pairs of images with different resolution based on measurement of disparities. The advantage of multi-range approach is that we can get more reliable disparity in each defined range because disparities from high resolution image are used for farther object a while disparities from low resolution images are used for close objects. The reliable disparity map is combined through post-processing for rejecting incorrect disparity information from each disparity map. The real distance from a disparity image is converted into an occupancy grid representation of a mobile robot. We have investigated the possibility of multi-range approach for the detection of obstacles and visual mapping through various experiments.

Quantitation of Flurbiprofen in Isopropyl Myristate by High Performance Liquid Chromatography (고속액체크로마토그래피를 이용한 미리스틴산이소프로필증 플루르비프로펜의 정량)

  • Kim, Hyun;Chi, Sang-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.1
    • /
    • pp.63-68
    • /
    • 1992
  • An HPLC procedure with UV detection has been developed for the quantitation of flurbiprofen released into isopropyl myristate used as the receptor phase in an in vitro membraneless drug diffusion cell. The drug and the internal standard (oxaprozin) were extracted from isopropyl myristate with a mixture of dimethylsulfoxide:methanol:water (2:1:1) and quantitated using a reverse phase $C_{18}$ column. The chromatograms were completely free from interfering peaks, and the relative retention times of flurbiprofen and the internal standard were 4.9 and 6.8 min, respectively. Calibration plots were linear over the concentration range of $1-200\;{\mu}g/ml$ of flurbiprofen with correlation coefficients, all higher than 0.99. The mean intra-day precision and accuracy among three replicate sets of the assay in a day were 4.26 and 4.52%, respectively, whereas the mean inter-day precision and accuracy were 3.35 and 3.64%, respectively. The mean recovery of the drug was 92.5% over the calibration range. The method was simple, reliable and accurate for the quantitation of flurbiprofen in unpurified isopropyl myristate.

  • PDF

Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS. (RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰)

  • Moon, Un-Chull
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Augmented Reality Using Projective Information (비유클리드공간 정보를 사용하는 증강현실)

  • 서용덕;홍기상
    • Journal of Broadcast Engineering
    • /
    • v.4 no.2
    • /
    • pp.87-102
    • /
    • 1999
  • We propose an algorithm for augmenting a real video sequence with views of graphics ojbects without metric calibration of the video camera by representing the motion of the video camera in projective space. We define a virtual camera, through which views of graphics objects are generated. attached to the real camera by specifying image locations of the world coordinate system of the virtual world. The virtual camera is decomposed into calibration and motion components in order to make full use of graphics tools. The projective motion of the real camera recovered from image matches has a function of transferring the virtual camera and makes the virtual camera move according to the motion of the real camera. The virtual camera also follows the change of the internal parameters of the real camera. This paper shows theoretical and experimental results of our application of non-metric vision to augmented reality.

  • PDF

Quality Assessment of Beef Using Computer Vision Technology

  • Rahman, Md. Faizur;Iqbal, Abdullah;Hashem, Md. Abul;Adedeji, Akinbode A.
    • Food Science of Animal Resources
    • /
    • v.40 no.6
    • /
    • pp.896-907
    • /
    • 2020
  • Imaging technique or computer vision (CV) technology has received huge attention as a rapid and non-destructive technique throughout the world for measuring quality attributes of agricultural products including meat and meat products. This study was conducted to test the ability of CV technology to predict the quality attributes of beef. Images were captured from longissimus dorsi muscle in beef at 24 h post-mortem. Traits evaluated were color value (L*, a*, b*), pH, drip loss, cooking loss, dry matter, moisture, crude protein, fat, ash, thiobarbituric acid reactive substance (TBARS), peroxide value (POV), free fatty acid (FFA), total coliform count (TCC), total viable count (TVC) and total yeast-mould count (TYMC). Images were analyzed using the Matlab software (R2015a). Different reference values were determined by physicochemical, proximate, biochemical and microbiological test. All determination were done in triplicate and the mean value was reported. Data analysis was carried out using the programme Statgraphics Centurion XVI. Calibration and validation model were fitted using the software Unscrambler X version 9.7. A higher correlation found in a* (r=0.65) and moisture (r=0.56) with 'a*' value obtained from image analysis and the highest calibration and prediction accuracy was found in lightness (r2c=0.73, r2p=0.69) in beef. Results of this work show that CV technology may be a useful tool for predicting meat quality traits in the laboratory and meat processing industries.