• Title/Summary/Keyword: calibration factors

Search Result 372, Processing Time 0.027 seconds

Antenna Gain Measurement in Time Domain (시간 영역에서 안테나 이득 측정 연구)

  • Park, Jungkuy;Kim, Woo-Nyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1217-1227
    • /
    • 2012
  • There are several antenna calibration methods, so-called 3-Antenna Method, Standard Site Method, and Standard Antenna Method which measure the antenna gains or antenna factors. These methods yield the free space or quasi free space antenna gains in only the frequency domain. In this paper, an antenna calibration method using the time domain in the open area test site is discussed. The reflected waves due to the ground are traced in the time domain. After they are removed by the time gating function of network analyzer, the free space transmission coefficient $S_{21}$ is extracted. Such a way is applied to the broad band horn antenna ranging 1 GHz to 18 GHz, and the free space gains are obtained by Friis transmission equation. The method is checked by Standard Site Method in open area test site. The results show comparatively good agreement except for 18 GHz.

Developing Customized Phantom for Korean Bone Density Using 3D Printing (3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

Analysis of Live Load Factor for Bridge Evaluation Through Reliability Based Load Factor Calibration (신뢰도기반 하중계수 캘리브레이션을 통한 교량 평가 활하중계수 분석)

  • Yoo, Min-Sun;Kim, Kyung-Hyun;Paik, In-Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.212-221
    • /
    • 2022
  • In this paper, the evaluation procedure applying the limit state design method is studied to be consistent with the newly issued bridge design code in Korea. The live load factor for evaluation is proposed by calibrating for the target reliability index through reliability analysis. Using the actual bridge information collected for the representative bridge types in Korea, the load effects of the design live loads for the previous and current design codes are calculated and compared. The live load factor is calibrated through reliability analysis using the minimum required strength which equals to the load effect obtained for the example bridge. Bridge evaluation is performed by applying the live load factors for the evaluation level as well as design level. The load rating result is generally increased by applying the limit state design method compared to the previous design method and applying the proposed load factor for lowered target reliability index further increased the rating result.

Centrifuge Model Analysis on Mooring Line Deformation (닻줄변형에 관한 원심모형해석)

  • Han, Heui-Soo;Cho, Jae-Ho;Chang, Dong-Hun;Jeong, Yeon-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.9
    • /
    • pp.15-22
    • /
    • 2006
  • Single segmented mooring lines were tested in a geotechnical centrifuge for the purpose of calibrating the analytical solution developed for the analysis and design of various mooring lines associated with underwater drag/permanent anchors. The model mooring lines included steel ball chains and wire cables placed at various depths within the soft clayey seafloor soil. The mooring lines were loaded to preset tensions at the water surface under an elevated acceleration inside the centrifuge to simulate the field stress conditions experienced by the prototype mooring lines. This paper describes the calibration of two factors that are used as part of the input parameters in the analytical solution of mooring lines and considers the effect of chasing wires that were used in the experiment to determine the locations of the mooring lines.

Evaluation of CPT-based Pile Load Capacity Factors with Cylindrical and Taper Pile (원통형 및 테이퍼말뚝의 하중-침하특성 및 CPT지지력상관계수)

  • Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong;Kim, Min-Kee;Hwang, Sung-Wuk
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.59-68
    • /
    • 2007
  • In this study, evaluation of load capacity and CPT-load capacity parameters were performed using calibration chamber tests for different types of piles including straight-side and tapered piles. Various soil conditions were considered in the investigation, aiming at establishing design procedure for foundation of electronic transmission tower structures. Test results show that no significant difference of total load capacity from straight-side and tapered piles, while individual components of base and shaft load capacities were quite different. Based on the test results, values of CPT-load capacity correlation parameters for different pile types were analyzed for the evaluation of both base and shaft load capacities.

Uncertainty Analysis based on LENS-GRM

  • Lee, Sang Hyup;Seong, Yeon Jeong;Park, KiDoo;Jung, Young Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.208-208
    • /
    • 2022
  • Recently, the frequency of abnormal weather due to complex factors such as global warming is increasing frequently. From the past rainfall patterns, it is evident that climate change is causing irregular rainfall patterns. This phenomenon causes difficulty in predicting rainfall and makes it difficult to prevent and cope with natural disasters, casuing human and property damages. Therefore, accurate rainfall estimation and rainfall occurrence time prediction could be one of the ways to prevent and mitigate damage caused by flood and drought disasters. However, rainfall prediction has a lot of uncertainty, so it is necessary to understand and reduce this uncertainty. In addition, when accurate rainfall prediction is applied to the rainfall-runoff model, the accuracy of the runoff prediction can be improved. In this regard, this study aims to increase the reliability of rainfall prediction by analyzing the uncertainty of the Korean rainfall ensemble prediction data and the outflow analysis model using the Limited Area ENsemble (LENS) and the Grid based Rainfall-runoff Model (GRM) models. First, the possibility of improving rainfall prediction ability is reviewed using the QM (Quantile Mapping) technique among the bias correction techniques. Then, the GRM parameter calibration was performed twice, and the likelihood-parameter applicability evaluation and uncertainty analysis were performed using R2, NSE, PBIAS, and Log-normal. The rainfall prediction data were applied to the rainfall-runoff model and evaluated before and after calibration. It is expected that more reliable flood prediction will be possible by reducing uncertainty in rainfall ensemble data when applying to the runoff model in selecting behavioral models for user uncertainty analysis. Also, it can be used as a basis of flood prediction research by integrating other parameters such as geological characteristics and rainfall events.

  • PDF

Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System (표준 감마선 전리함 장치에 의한 방사능 비교 측정)

  • Park, Tae-Soon;Woo, Dong-Ho;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • A Standard gamma-ray ionization chamber system was developed with a well type ionization chamber and micro current measuring circuit. Micro current was measured by the automatic Townsend balance with stepwise compensation method. For gamma emitting nuclides such as $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs,\;and\;^{22}Na$ relative calibration factors to $^{226}Ra$ reference source were calculated and detection .efficiency curve was determined as a fudnction of gamma energy.

  • PDF

Determination of Chlorpromazine Using Plasticizers as Extraction Solvent (가소제를 이용한 클로르프로마진의 용매 추출 분광광도법)

  • Lee, Ji-Yeoun;Jung, Moon-Mo;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.42 no.3
    • /
    • pp.243-247
    • /
    • 1998
  • A method for the determination of basic drugs based on their reaction with picric acid to form an ion-association complex extractable into several plasticizers was developed. Ba sic drugs-picric acid complexes in acid medium could be extracted quantitatively into several plasticizers except phosphates. For example, the chlorpromazine-picric acid complex showed maximum absorbance at near 410nm and was applied to extraction spectrophotometric determination of chlorpromazine. The calibration curves are linear (r>0.998) within a range from $10^{-6}to\;5{\times}10^{-4}M$ and the precision of the method was acceptable because RSD was less than 2.6% (n=7). The factors affecting the extraction system was discussed.

  • PDF

Conversion Factors for Calibration of Personnel Dosimeters (개인선량계 교정을 위한 환산인자 계산)

  • Lee, Won-Koo;Lee, Tae-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 1991
  • MCNP code was used to calculate conversion factor H(d)ma at the depths of 0.07 and 10mm within a water phantom recommended by IAEA and within a PMMA phantom required by the US dosimeter proficiency testing programmes. The calculations were performed for an expanded parrallel beam of monoenergetic photons of perpendicular incidence on one faces of the phantom. The results can be used as conversion factor in calibrating individual dosemeters in terms of the dose equivalent quantities defined directly in the phantom.

  • PDF

Flow Control of a Solenoid Gas Injector and Its Application on a Natural Gas Engine (솔레노이드 가스 인젝터의 유량제어와 천연가스엔진에서의 응용)

  • Sim, Han-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.83-89
    • /
    • 2009
  • An air-fuel ratio control is essential in reducing hazardous exhaust emissions from a compressed natural gas(CNG) engine, and can be accomplished by accurate control of gas injection flow. In this study, theoretical research was conducted on injection characteristics of a solenoid gas injector, and injection experiments for calibration and analysis were performed. Various factors for gas injection flow such as injection pressure, gas temperature, and supply voltage are studied. A dynamic flow equation of the natural gas was proposed on the basis of flow dynamics theories and results of the injection experiment. The verification of the dynamic flow equation of the solenoid injector was carried out with a large CNG-engine applied to an urban bus. Air-fuel ratio control experiments were conducted in both steady and transient state. Results of injection experiments for the solenoid injector and the CNG-engine was proved the control method proposed herein to be effective.

  • PDF