Kim, Jin-Soo;Jin, Cheong-Gil;Lee, Seong-Kyu;Lee, Sun-Gu;Choi, Chul-Uong
Journal of Korean Society for Geospatial Information Science
/
v.19
no.3
/
pp.115-125
/
2011
The smartphones which have been recently are embedded with high resolution quality camera, assisted GPS, accelerometer, gyroscope and various sensors including magnetometer sensor that could be directly used for measurement. This study aims to suggest the possible application of smartphone camera providing high resolution images in terms of photogrammetry by calibrating it and assessing its accuracy. First of all, prior to the accuracy assessment of smartphone camera, camera calibration was conducted to correct lens distortion of each camera and the accuracy of image coordinates and object coordinates calculated by bundle adjustment during this procedure was analyzed. Also regarding three-dimensional positioning, result analysis depending on considering lens distortion coefficients was conducted, and finally relative accuracy of smartphone camera on metric camera was assessed. The result showed that in terms of distortion correction of smartphone camera, also higher order symmetric radial lens distortion coefficients should be considered, and three dimensional position determined by smartphone images was a little difference from that by metric camera. Therefore it is expected that smartphone images have huge possibility to be used for photogrammetry.
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.15
no.2
/
pp.121-126
/
2004
This paper presents an SAR-data calibration technique using a well-calibrated scatterometer. At first a fully-polarimetric antenna pattern(magnitude and phase) of the antenna main-beam using a conducting sphere was measured. Then, this data were used to calibrate polarimetrically an auto-mounted network analyzer-based scatterometer system. This scatterometer system can be used to measure the accurate Mueller matrices of earth surfaces such as grass fields, rice fields and bare soil surfaces; i.e., the phase-difference parameters can be obtained as well as the radar scattering coefficients. If a polarimetrically calibrated scatterometer is operated at the same time with the SAR system, the scatterometer data can be used to correct the SAR data, especially the phase-difference parameters. It was found that the correction effect is remarkable for the degree of correlation ${\alpha}$, which is one of the phase-difference parameter, while the correction effect is negligible for the magnitude parameters(backscattering coefficients).
In this paper, we experimentally investigated the precision of 3D positioning using 4S-Van images in photograrmmetric perspective. The 3D calibration target was built over building facade outside and was captured separately by two CCD cameras installed in 4S-Van. After then, we determined the interior orientation parameter for each CCD camera through self-calibration technique. With the interior orientation parameter computed, the bundle adjustment was performed to obtain the exterior orientation parameters simultaneously for two CCD cameras using calibration target image and object coordinates. The reverse lens distortion coefficients were computed and acquired by least squares method so as to introduce lens distortion into epipolar line. It was shown that the reverse lens distortion coefficients could transform image coordinates into lens distorted image coordinates within about 0.5 pixel. The proposed semi-automatic matching scheme incorporated with lens distorted epipolar line was implemented with scene images captured by 4S-Van in moving. The experimental results showed that the precision of 3D positioning from 4S-Van images in photograrmmetric perspective is within 2cm in the range of 20m from the camera.
Seo, Jeong-Sik;Choi, Young-Don;Bea, Kyong-Kuen;An, Jeong-Soo
Proceedings of the SAREK Conference
/
2007.11a
/
pp.191-196
/
2007
This paper presents the measuring technique for local heat transfer coefficients using a copper sensor in a rod bundle with mixing vanes. A copper sensor consists of a cartridge heater and four pieces of thermocouple. The Heater is located at the center of the copper sensor and thermocouples measure the surface temperature of the copper sensor. Unheated copper sensor and heated copper sensor are able to measure the local heat transfer coefficient at the position where the heated copper sensor is installed. However the entire region of a rod bundle is actually not heated, the decay of local heat transfer coefficients measured represents overestimated value rather than an actual value. The calibration curve for local heat transfer coefficients is presented using the correction factor calculated by CFD.
Kim, Hyung Tae;Lee, Duk Yeon;Choi, Dongwoon;Kang, Jaehyeon;Lee, Dong-Wook
Current Optics and Photonics
/
v.6
no.2
/
pp.161-170
/
2022
Three-dimensional (3D) geometric models are introduced to correct vignetting, and a downhill simplex search is applied to determine the coefficients of a 3D model used in digital microscopy. Vignetting is nonuniform illuminance with a geometric regularity on a two-dimensional (2D) image plane, which allows the illuminance distribution to be estimated using 3D models. The 3D models are defined using generalized polynomials and arbitrary coefficients. Because the 3D models are nonlinear, their coefficients are determined using a simplex search. The cost function of the simplex search is defined to minimize the error between the 3D model and the reference image of a standard white board. The conventional and proposed methods for correcting the vignetting are used in experiments on four inspection systems based on machine vision and microscopy. The methods are investigated using various performance indices, including the coefficient of determination, the mean absolute error, and the uniformity after correction. The proposed method is intuitive and shows performance similar to the conventional approach, using a smaller number of coefficients.
Satellite cameras are calibrated before launch in detail and in general, but it cannot be guaranteed that the geometry is not changing during launch and caused by thermal influence of the sun in the orbit. Modem satellite imaging systems are based on CCD-line sensors. Because of the required high sampling rate the length of used CCD-lines is limited. For reaching a sufficient swath width, some CCD-lines are combined to a longer virtual CCD-line. The images generated by the individual CCD-lines do overlap slightly and so they can be shifted in x- and y-direction in relation to a chosen reference image just based on tie points. For the alignment and difference in scale, control points are required. The resulting virtual image has only negligible errors in areas with very large difference in height caused by the difference in the location of the projection centers. Color images can be related to the joint panchromatic scenes just based on tie points. Pan-sharpened images may show only small color shifts in very mountainous areas and for moving objects. The direct sensor orientation has to be calibrated based on control points. Discrepancies in horizontal shift can only be separated from attitude discrepancies with a good three-dimensional control point distribution. For such a calibration a program based on geometric reconstruction of the sensor orientation is required. The approximations by 3D-affine transformation or direct linear transformation (DL n cannot be used. These methods do have also disadvantages for standard sensor orientation. The image orientation by geometric reconstruction can be improved by self calibration with additional parameters for the analysis and compensation of remaining systematic effects for example caused by a not linear CCD-line. The determined sensor geometry can be used for the generation? of rational polynomial coefficients, describing the sensor geometry by relations of polynomials of the ground coordinates X, Y and Z.
Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
/
v.30
no.2
/
pp.173-180
/
2012
The most recent, 80 mega pixels digital camera appeared through the development of digital technology, and nonmetric digital cameras have been using in various field of photogrammetry. In this study, we experimented lens calibration using aerial photographs and ground control points. The aerial photographs were taken a non-metric digital camera which is CMOS(Complementary Metal Oxide Semiconductor) 21.1 mega pixels sensor and 35mm lens at a helicopter. And the ground control points were selected on the 1:1,000 plotting origin data. As a result, we calculated focal length, PPA(Principal Point of Autocollimation) and symmetric radial distortion coefficients from the lens. Also, RMSE(root mean square error) and maximum residual of the ground control points from the aerial triangulation were compared before and after calibration. And we found that the accuracy of the after calibration was improved very significantly.
Journal of the Korean Society for Aeronautical & Space Sciences
/
v.32
no.10
/
pp.53-59
/
2004
A calibration technique for a redundant IMU with low-grade inertial sensors is proposed. In order to calibrate the redundant IMU that can detect and isolate a faulty sensor, the fundamental coordinate frames in the IMU are defined and the IMU error is modeled based on the frames. Equations to estimate the error coefficients of the redundant IMU are formulated, and a test sequence using the 2-axis rate table is also presented. Finally, a redundant IMU with cone configuration is implemented using the low-grade inertial sensors and the performance of the proposed technique is verified by some experiments.
We consider use of Bootstrap calibration in the problem of setting a confidence interval for a linear combination of variance components. Based on the the modified large sample(MLS) method by Graybill and Wang(1980), Bootstrap Calibration is applied to improve the coverage probability of the MLS confidence bound when the experiment is balanced and coefficients of a linear combination are positive. Performance of the proposed confidence bound in small sample is investigated by simulation studies.
Journal of The Korean Society of Agricultural Engineers
/
v.53
no.5
/
pp.9-16
/
2011
Curve Numbers (CN) for the combination of land use and hydrologic soil group were regionalized at Imha Watershed using Long-term Hydrologic Impact Assessment (L-THIA) coupled with SCE-UA. The L-THIA was calibrated during 1991-2000 and validated during 2001-2007 using monthly observed direct runoff data. The Nash-Sutcliffe (NS) coefficients for calibration and validation were 0.91 and 0.93, respectively, and showed high model efficiency. Based on the criteria of model calibration, both calibration and validation represented 'very good' fit with observe data. The spatial distribution of direct surface runoff by L-THIA represented runoff from Thiessen pologen at Subi and Sukbo rain gage station much higher than other area due to the combination of poor hydrologic condition (hydrologic soil C and D group) and locality heavy rainfall. As a results of hydrologic condition and treatment for land use type based on calibrated CNs, forest is recommended to be hydrologically modelled dived into deciduous, coniferous, and mixed forest due to the hydrological difference. The CNs for forest and upland showed the poor hydrologic condition. The steep slope of forest and alpine agricultural field make high runoff rate which is the poor hydrologic condition because CN method can not consider field slope. L-THIA linded with SCE-UA could generated a regionalized CNs for land use type with minimized time and effort, and maximized model's accuracy.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.