• 제목/요약/키워드: calibration coefficients

검색결과 328건 처리시간 0.024초

오비트랩 고분해능 질량분석기를 이용한 폐사 조류 중 다성분 잔류 농약 스크리닝 기법 (Residual Multi Pesticides Screening of Dead Birds by Orbitrap High Resolution Mass Spectrometry)

  • 이두희;김보경;왕승준;손기동;정현미;최종우
    • 한국환경농학회지
    • /
    • 제36권4호
    • /
    • pp.269-278
    • /
    • 2017
  • BACKGROUND: The objective of this study was to evaluate screening method of residual multi pesticides in dead birds by Orbitrap high resolution mass spectrometry (HRMS) to identify the cause of death for birds. METHODS AND RESULTS: Extraction and clean-up method of residual pesticides in liver of dead birds was used QuEChERS (Quick Easy Cheap Effective Rugged and Safe) and method validations was conducted using liquid chromatography and gas chroamtography with triple-quadrupole mass spectrometer (LC/MS/MS and GC/MS/MS) Also, we were evaluated screening method for the determination of residual pesticides in liver of dead birds by LC and GC Orbitrap Mass Spectrometry. Results of method validations, Correlation coefficients of the matrix matched calibration curves were >0.978, and the method detection limits (MDLs) and limits of quantitation (LOQ) were 2.8~72.1 ng/g (18.4 ng/g on average) and 9.0~230 ng/g (58.5 ng/g on average). The accuracy ranged from 69.1%to 130% (103% on average), and the precision values were less than 14.8%(3.8%on average). The screening of residual pesticides in liver of dead birds by LC and GC Orbitrap HRMS was detected monocrotophos, carbofuran, carbosulfan, deltametrin, benfuracarb, carbofuran, phosphamidon, prochloraz in investigated samples. CONCLUSION: This results showed that accurate mass were extraction of residual pesticides in dead birds by Orbitrap HRMS. It suggested that this screening method is applicable to the residual pesticide analysis for the cause of death as a main tool.

통조림관 코팅제에서 식품유사용매로 이행되는 비스페놀류의 분석 (Determination of Bisphenols Migrating from Epoxy Can Coatings to Aqueous Food Simulants)

  • 강경모;신효선
    • 한국식품과학회지
    • /
    • 제32권3호
    • /
    • pp.570-577
    • /
    • 2000
  • 세가지 식품유사용매(증류수, 4% acetic acid, 20% ethanol)중의 비스페놀류(BPF, BPA, BFDGE, BADGE)를 형광검출기의 역상 HPLC와 GC/MSD에 의해 분석하는 방법을 제안하였다. 각 비스폐놀류는 $5{\sim}800\;{\mu}g/L$의 검량선에서 상관계수 0.9998 이상이었고 검출한계는 $1.2\;{\mu}g$이하였다. $200\;{\mu}g/L$에서의 정밀도는 3.1%이하였다. 각 식품유사용매에 비스페놀류를 일정량씩 첨가하여 동시 분석하였을 때 BPF와 BPA의 회수율은 95% 이상이었고, BFDGE와 BADGE는 약 80%였으나, 개별 첨가하였 때는 BFDGE와 BADGE 회수율이 95%이상으로 증가하였다. 이 때 검출한계는 모두 $0.40\;{\mu}g$이하였다. Epoxy phenol, modified epoxy, epoxy ester phenol 및 thermoset vinyl의 재질로 내부 코팅한 통조림관에서 식품유사용매로 이행되는 비스페놀류는 역상 HPLC에 의한 정량과 GC/MSD로 확인하였다 모든 재질에서 3가지 식품유사용매에 의해 BPF, BFDGE, BADGE는 검출되지 않았으나 4% acetic acid와 20% ethanol에 의해 modified epoxy를 제외한 재질에서 모두 BPA가 검출되었다.

  • PDF

Thermoluminescence 측정에 의한 조미분말식품의 방사선 조사유무 확인 (Detection of Irradiation Treatment for Seasoned-Powdered Foods by Thermoluminescence Measurement)

  • 정형욱;권중호
    • 한국식품과학회지
    • /
    • 제30권3호
    • /
    • pp.509-516
    • /
    • 1998
  • 조개추출물분말, 해물조미베이스, 라면분말수프, 정어리추출물분말 등 조미분말식품에 대한 TL 검지방법의 적용가능성을 확인하였다. 이들 시료의 방사선 조사선량과 TL response 간의 $R^2$는0.5966 이상을 보여 주었고, 특히 라면수프는 0.9500 이상의 상관계수를 보이면서 방사선 조사선량이 증가할수록 TL intensity도 증가하였다. 따라서 라면수프 시료를 대상으로 re-irradiation step에 의한 TL response의 검증을 실시하였고, 미지시료의 검지에 필요한 역치(threshold value)를 측정하였다. 이때 비조사 시료의 역치는 최고 1.37 이하였고, 감마선 조사시료(2.5 kGy) 역치는 최저 6.06 이상이였다. 그리고 1.37과 6.06 사이의 역치를 나타내는 미지시료는 재조사하여 방사선 조사유무를 검지하였고, 검지시료의 호기성 전세균의 수를 측정함으로써 검지 결과를 검증하였다. Blind test의 일환으로 실시한 미지시료 검지실험에서는 본 실험에서 설정한 역치의 적용으로 총 167개 시료(감마선 82, 전자선 85)의 방사선 조사유무를 정확하게 확인할 수 있었다. 방사선 조사선량을 예측하기 위하여 3가지 예측모델식을 설정하고 조사선량을 예측하여 본 결과, 2차회귀식이 가장 적합하였으나 실제 조사선량과는 상당한 오차를 보였다.

  • PDF

Nylon Membrane Filter에서의 발광증폭을 이용한 $Eu^{+3}$$Tb^{+3}$ 이온의 극미량 분석법 (A New Analytical Method for the $Eu^{+3}$ and $Tb^{+3}$ Ions Using the Luminescence Enhancement by the Treatment of o-Phenanthroline on the Nylon Membrane)

  • 안성희;이병민;박종목;김해동;정혁
    • 대한화학회지
    • /
    • 제39권9호
    • /
    • pp.705-714
    • /
    • 1995
  • 란탄이온의 특성 발광선 세기가 Nylon Membrane상에서 증폭되는 현상을 이용하여 $Eu^{+3}$$Tb^{+3}$이온에 대한 고감도의 미량분석법에 대하여 연구아였다. 수용액(혹은 에탄올 용액) 상태에서의 $Eu^{+3}$$Tb^{+3}$두이온의 발광선의 세기에 비하여 주어진 용액 시료를 Nylon Membrane에 점적하면 이온의 방출선의 세기가 매우증가하였으며 특히 점적된 이온에 o-phenanthroline을 추가로 점적하면 방출선의 세기가 더욱 증가하는 증폭현상을 이용하여 $Eu6{+3}$$Tb^{+3}$이온의 검출한계를 용액 시료에 비하여 $10_7$배 이상 개선하였으며 이때의 검정곡선은 검출한계 근처에서 2-3 order의 선형범위(dynamic range)와 상관계수가 0.99 이상인 직선성을 나타냈으며 또한 TLC 방법에 비하여 10배정도의 검출한계 개선효과를 얻었다. 한편 o-phenanthroline의 변화에 따른 선세기의 변화를 관찰한 결과 -4몰비 정도에 최대의 선세기를 보였으며 그 이상에서는 일정한 선세기를 나타내었는데 이런한 발광증폭의 이론적인 배경으로 착물내의 리간드와 란탄이온 사이의 energytransfer mechanism을 설명하였다.

  • PDF

체계신뢰성(體系信賴性) 방법(方法)에 기초(基礎)한 R.C. 도로교(道路橋) 상부구조(上部構造)의 근사적(近似的) 신뢰성해석(信賴性解析) 모형(模型) (Approximate Reliability Analysis Model for R.C. Bridge Superstructures based on Systems Reliability Methods)

  • 조효남;구본성
    • 대한토목학회논문집
    • /
    • 제7권2호
    • /
    • pp.79-88
    • /
    • 1987
  • 본(本) 연구(硏究)는 체계신뢰성방법(體系信賴性方法)에 기초(基礎)하여 R.C. 도로교(道路橋) 상부구조(上部構造)의 체계신뢰성(體系信賴性) 모형(模型)을 제안(提案)하는데 주안점을 두고 있다. R.C. T 항교(桁橋)에서 두개의 인접거어더가 파괴될때 상부구조(上部構造)가 극한내하력상관(極限耐荷力狀觀)에 도달된다는 근사적인 가정(假定)하에 Level 2 체계모형화(體系模型化)시켜 병직렬(並直列)(parallel-series)체계(體系)의 파괴확률(破壞確率)을 구(求)하는 점추정(點推定) 해법(解法)을 실용적(實用的)인 쳬계신뢰성(體系信賴性) 해법(解法)으로 제안(提案)하였다. 제안(提案)된 체계신뢰성모형(體系信賴性模型)을 실제(實際) 보존교량(보存橋梁)에 적용(適用)하여 각(各) 파괴요소(破壞要素) 및 破壞(破壞)모드간(間) 상관계수(相關係數)의 변화(變化)에 따른 쳬계신뢰성(體系信賴性)의 예민도(銳敏度) 분석(分析)을 행(行)하였으며 요소신뢰성(要素信賴性)과 체계신뢰성(體系信賴性)의 관계(關係)도 고찰(考察)하였다. 본(本) 연구(硏究)에서 제시(提示)하는 점추정방법(點推定方法)에 의한 체계신뢰성(體系信賴性)은 Ditlevsen 구간해(區間解)의 평균치(平均値)에 해당하는 안전측해(安全側解)를 나타내었다. 또한 체계신뢰성(體系信賴性) ${\beta}_s$는 각(各) 파괴요소(破壞要素) 및 파괴(破壞)모드간(間) 상관계수(相關係數)의 변화(變化)에 대단히 예민(銳敏)하게 변화(變化)하는 것을 알수 있었다. 본(本) 연구(硏究)에서 제시(提案)한 체계신뢰성(體系信賴性) 모형(模型)에 의한 근사해법(近似解法)으로 실제(實際) 보존교량(보存橋梁)의 체계신뢰성(體系信賴性)을 해석(解析)하고 요소신뢰성(要藥信賴性)과의 차이(差異)를 비교(比數)하였으며, 아울러 체계목표신뢰성(體系目標信賴性) 개념에 기초(基礎)한 신뢰성규준(信賴性規準)의 검정방향(檢定方向)을 제시(提示)하였다.

  • PDF

Studies on the Analysis of Benzo(a)pyrene and Its Metabolites on Biological Samples by Using High Performance Liquid Chromatography/Fluorescence Detection and Gas Chromatography/Mass Spectrometry

  • Lee, Won;Shin, Hye-Seung;Hong, Jee-Eun;Pyo, Hee-Soo;Kim, Yun-Je
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권5호
    • /
    • pp.559-565
    • /
    • 2003
  • An analytical method the determination of benzo(a)pyrene (BaP) and its hydroxylated metabolites, 1-hydroxybenzo(a)pyrene (1-OHBaP), 3-hydroxybenzo(a)pyrene (3-OHBaP), benzo(a)pyrene-4,5-dihydrodiol (4,5-diolBaP) and benzo(a)pyrene-7,8-dihydrodiol (7,8-diolBaP), in rat urine and plasma has been developed by HPLC/FLD and GC/MS. The derivatization with alkyl iodide was employed to improve the resolution and the detection of two mono hydroxylated metabolites, 1-OHBaP and 3-OHBaP, in LC and GC. BaP and its four metabolites in spiked urine were successfully separated by gradient elution on reverse phase ODS $C_{18}$ column (4.6 mm I.D., 100 mm length, particle size 5 ㎛) using a binary mixture of MeOH/H₂O (85/15, v/v) as mobile phase after ethylation at 90 ℃ for 10 min. The extraction recoveries of BaP and its metabolites in spiked samples with liquid-liquid extraction, which was better than solid phase extraction, were in the range of 90.3- 101.6% in n-hexane for urine and 95.7-106.3% in acetone for plasma, respectively. The calibration curves has shown good linearity with the correlation coefficients (R²) varying from 0.992 to 1.000 for urine and from 0.996 to 1.000 for plasma, respectively. The detection limits of all analytes were obtained in the range of 0.01-0.1 ng/mL for urine and 0.1-0.4 ng/mL for plasma, respectively. The metabolites of BaP were excreted as mono hydroxy and dihydrodiol forms after intraperitoneal injection of 20 mg/kg of BaP to rats. The total amounts of BaP and four metabolites excreted in dosed rat urine were 3.79 ng over the 0-96 hr period from adminstration and the excretional recovery was less than 0.065% of the injection amounts of BaP. The proposed method was successfully applied to the determination of BaP and its hydroxylated metabolites in rat urine and plasma for the pharmacokinetic studies.

용매 고분자막 상에 고정된 나트륨 이온선택성 물질의 착물형성상수 결정 (Determination of Complex Formation Constant of Sodium-Selective Ionophores in Solvent Polymeric Membranes)

  • 강태영;김성배;오현준;한상현;차근식;남학현
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.466-473
    • /
    • 2000
  • 용매고분자막 상에 칼륨과 다양한 나트륨이온 선택성 중성 운반체의 착물형성상수(${\beta}_{MLn}$)를 고분자막형 광센서(optode)와 이온선택성 전극(ISE)을 이용하여 결정하였다. 수소이온선택성 발색물질(chromoionophore : ETH 5294)에 가장 널리 쓰이는 나트륨 이온선택성 물질들(4-tert-butylcalix[4]arenetetraacetic acid tetraethyl ester, ETH 2120, bis[(12-crown-4)methyl] dodecyl-methylmalonate 및 monensin methyl ester)을 첨가한 막과 첨가하지 않은 막으로 두 가지 다른 조성의 PVC 막을 제작하여, 일정 pH(0.05 M Tris-HCl, pH7.2)에서 알칼리금속 양이온(나트륨과 칼륨)의 농도 변화에 따른 광학적 감응을 측정하고, 또 일정한 알칼리금속 양이온 농도(0.1M)에서 pH변화에 따른 광학적 감응을 측정하였다. 또한 유사한 조성의 막을 각각 재래식 전극체에 장착하고 일정한 알칼리금속 양이온의 농도(0.1M)에서 pH 변화에 따른 전위치를 측정하였다. 양이온/수소이온의 활동도 비($a_{M^+}/a_{H^+}$)와 상대흡광도로 도시한 광센서 감응곡선과 수소이온농도에 따른 전위차 감응곡선으로부터 나트륨 이온선택성 리간드들의 착물형성상수를 결정하였다. 목적이온과 방해이온에 대한 착물형성상수들의 비로부터 얻어진 값은 실험적으로 얻어진 이온선택성 전극의 선택계수와 근접함을 확인하였다.

  • PDF

LC-MS/MS를 이용한 베타락탐계 항생제와 베타차단제의 동시분석 (Simultaneous analysis of β-lactam antibiotics and β-blockers by LC-MS/MS)

  • 손보영;김준일;안치화;이수원;김복순;정득모
    • 분석과학
    • /
    • 제29권4호
    • /
    • pp.179-185
    • /
    • 2016
  • 물 시료 중에 잔류하는 β-차단제 3종(아테놀롤, 메토프롤롤, 프로프라놀롤)과 β-락탐계 항생제 6종(아목시실린, 페니실린G, 세파클러, 세파드록실, 세파렉신, 세프라딘)을 다른 두 종류의 카트리지를 사용하여 효과적인 분석방법을 정립하였다. 고분자 친수성-친유성 균형 카트리지(Hydrophile-lipophile balance, HLB)와 강한 양이온 교환 혼합 모드인 고분자 흡수 카트리지(Mixed mode cation exchange, MCX)를 사용하여 자동고체상 추출장치(Solid-phase extraction, SPE)로 전처리를 하였다. 충분한 크로마토그래피 분리를 위해 XDB-C18 (1.8 μm; 3.0 mm × 100 mm) 컬럼을 사용하였다. 정량을 위한 검정곡선의 상관계수(r²)가 0.995 이상으로 우수한 직선성을 나타내었다. 방법검출한계(Method detection limits, MDL)와 정량한계(Limit of quantitation, LOQ)는 각각 1.1~3.9 ng/L와 5~13 ng/L이었다. 이 분석방법으로 한강으로 유입되는 지천과 원수를 실태 조사 한 결과 N.D.~0.209 μg/L 농도로 검출되었다.

주성분 회귀분석 및 인공신경망을 이용한 AE변수와 응력확대계수와의 상관관계 해석 (Analysis on Correlation between AE Parameters and Stress Intensity Factor using Principal Component Regression and Artificial Neural Network)

  • 김기복;윤동진;정중채;박휘립;이승석
    • 비파괴검사학회지
    • /
    • 제21권1호
    • /
    • pp.80-90
    • /
    • 2001
  • AE 신호와 재료의 기계적 물성과의 관계를 정량적으로 제시할 수 있는 방법을 개발하였다. 재료의 여러 가지 기계적 성질들 중 피로균열 거동에 관련된 응력확대계수를 중심으로 AE 신호와 같은 다변량 데이터의 처리에 많이 사용되고 있는 주성분 회귀분석과 비선형적 문제 해결에 적합한 신경회로망 기법을 이용하였다. 이를 위하여 강교량 부재인 SWS490B 강에 대한 피로균열전파 실험을 수행하였으며 표준 CT 시편에 대한 피로균열진전 시 발생하는 AE 신호의 각 변수와 응력확대계수와의 관계를 고찰하였다. 통계분석 방법인 변수선택법을 적용한 결과 AE 카운트(RC), 에너지(EN), 신호지속시간(ED)의 각각에 대한 유의성이 높은 것으로 나타났으나 전반적으로 전체 AE 변수를 모두 이용할 경우 통계적 유의성이 높은 것으로 나타났다. 부재의 반복하중 시 발생하는 피로균열진전을 정량적으로 도출할 수 있는 응력확대계수 추정모델을 개발하고 평가하였다. 미지 시료에 대하여 개발된 모델의 응력확대계수 예측 성능을 분석한 결과 주성분 회귀모델과 인공신경망 모델 모두 우수한 예측성능을 나타내었으나 전반적으로 인공신경망 모델이 주성분 회귀모델보다 다소 양호한 것으로 분석되었다.

  • PDF

LC-MS/MS 및 GC-MS/MS를 활용한 수산물 중 디아제팜의 정량분석법 개발 (Development of the Analytical Method for Diazepam in Fishery Products using Liquid and Gas Chromatography-tandem Mass Spectrometry)

  • 신다솜;강희승;김주혜;정지윤;이규식
    • 한국식품위생안전성학회지
    • /
    • 제33권2호
    • /
    • pp.110-117
    • /
    • 2018
  • 본 연구는 국내 생산 및 수입 양식 수산물에 대해 잔류할 수 있는 향정신성 의약품인 디아제팜 대한 안전관리강화기반을 위해 마련되었다. 중국인민공화국 국가 표준시험법(GB 29697-2013)을 기반으로 전처리 방법을 개선하여 GC-MS/MS 시험법을 확립하였으며, LC-MS/MS 방법과의 기기간 검증을 통해 확립된 시험법의 선택성, 정량한계 및 회수율에 대한 검증을 통해 디아제팜 시험법으로서의 유효성을 확인하였다. LC-MS/MS의 경우 아세토니트릴로 추출 후 PSA를 이용해 정제하였고, GC-MS/MS의 경우 아세토니트릴로 추출후 $C_{18}$카트리지를 이용해 정제하였다. 디아제팜은 표준용액을 정량한계를 포함한 농도에 따라 검량선을 작성한 결과 두 기기 모두 $r^2$> 0.99 이상의 직선성을 확인하였다. 본 실험에서의 검출한계와 정량한계는 LC-MS/MS 및 GC-MS/MS 모두 0.0004 mg/kg, 0.001 mg/kg 수준이었으며, 평균 회수율은 각각 99.8~106%, 109~124%이었다. 또한, 분석오차는 모두 15% 이하로 정확성 및 재현성이 우수하였으며, CODEX 가이드라인 규정에 만족하는 수준이었다. 따라서 개발된 시험법은 안전한 수산물의 국내 유통과 잔류실태조사를 위해 활용될 것으로 기대한다.