• 제목/요약/키워드: calibrated numerical model

검색결과 189건 처리시간 0.087초

Evaluation of performance of piled-raft foundations on soft clay: A case study

  • Khanmohammadi, Mohammadreza;Fakharian, Kazem
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.43-50
    • /
    • 2018
  • Applicability of constructing piled raft foundations on soft clay has been given attention in recent years. Lack of sufficient stiffness for soil and thus excessive settlements to allow higher contribution of piles is the major concern in this regard. This paper presents a numerical investigation of performance of piled-raft foundations on soft clay with focusing on a case study. A 3D FEM numerical model is developed using ABAQUS. The model was calibrated by comparing physical and numerical modeling results of other researchers. Then the possibility of using piled-raft system in construction of foundation for a water storage tank in Sarbandar, Iran is assessed. Soil strength parameters in the numerical model were calibrated using the instrumentation data of a heavily instrumented preloading project at the construction site. The results indicate that choosing the proper combination of length and spacing for piles can lead to acceptable differential and total settlements while a high percentage of total bearing capacity of piles can be mobilized, which is an efficient solution for the project. Overall, the construction of piled-rafts on soft clays is promising as long as the total settlement of the structure is not imposing restrictions such as the common 25 mm allowable settlement. But instead, if higher allowable settlements are adopted, for example in the case of rigid steel tanks, the method shall be applicable with considerable cost savings.

Effect of model calibration on seismic behaviour of a historical mosque

  • Demir, Ali;Nohutcu, Halil;Ercan, Emre;Hokelekli, Emin;Altintas, Gokhan
    • Structural Engineering and Mechanics
    • /
    • 제60권5호
    • /
    • pp.749-760
    • /
    • 2016
  • The objective of the study is to investigate the effects of model calibration on seismic behaviour of a historical mosque which is one of the most significant Ottomon structures. Seismic analyses of calibrated and noncalibrated numeric models were carried out by using acceleration records of Kocaeli earthquake in 1999. In numerical analysis, existing crack zones on real structure was investigated in detail. As a result of analyses, maximum stresses and displacements of calibrated and noncalibrated numerical models were compared each other. Consequently, seismic behaviour and damage state of historical masonry Hafsa Sultan mosque was determined as more realistic in the event of a severe earthquake.

2차원 유한체적 수치모형을 이용한 대구획 논의 용배수 특성해석(관개배수 \circled2) (An Analysis of Irrigation and Drainage Characteristics at Large-Sized Paddy Fields Using a Two-Dimensional Numerical Model)

  • 박종민;박승우;강문성;강민구
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.162-168
    • /
    • 2000
  • A two-dimensional numerical model based on a finite volume method was formulated to solve the shallow water equations and applied for evaluating irrigation and drainage characteristics at large-sized paddy fields. Manning roughness coefficient was calibrated using the observed inundating depths at drainage tests and used for validating the model with the results from irrigation and drainage test. The simulated results were in good agreement with the observed inundating depths.

  • PDF

3층 전단벽 구조물의 지진응답에 관한 수치해석 (Numerical Study on Seismic Behavior of a Three-Story RC Shear Wall Structure)

  • 박다원;최영준;홍정욱
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.111-119
    • /
    • 2021
  • A shear wall is a structural member designed to effectively resist in-plane lateral forces, such as strong winds and earthquakes. Due to its efficiency and stability, shear walls are often installed in residential buildings and essential facilities such as nuclear power plants. In this research, to predict the results of the shaking table test of the three-story shear wall RC structure hosted by the Korea Atomic Energy Research Institute, three types of numerical modeling techniques are proposed: Preliminary, Calibrated 1, and Calibrated 2 models, in order of improvement. For the proposed models, an earthquake of the 2016 Gyeongju, South Korea (peak ground acceleration of 0.28 g) and its amplified earthquake (peak ground acceleration of 0.50 g) are input. The response spectra of the measuring points are obtained by numerical analysis. Good agreement is observed in the comparisons between the experiment results and the simulation conducted on the finally adopted numerical model, Calibrated 2. In the process of improving the model, this paper investigates the influences of the mode shape, material properties, and boundary conditions on the structure's seismic behavior.

Approximations of Optimal Calibration Experimental Designs Using Gaussian Influence Diagrams

  • Kim, Sung-Chul
    • Journal of the Korean Statistical Society
    • /
    • 제22권2호
    • /
    • pp.219-234
    • /
    • 1993
  • A measuring instrument must be calibrated for accurate inferences of an unknown quantity. Bayesian calibration designs with respect to squared error loss based on a linear model are discussed in Kim and Barlow (1992). In this paper, we consider approximations of the optimal calibration designs using the idea of Gaussian inflence diagrams. The approximation is evaluated by means of numerical calculations, where it is compared with the exact values from the numerical integration.

  • PDF

1차원 현장 soil column 실험을 통한 SAT 반응 모델 검증

  • 김정우;;차우석;최희철
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.83-86
    • /
    • 2003
  • Soil Aquifer Treatment (SAT) is a technique in which secondary- or tertiary-treated wastewater is infiltrated through unsaturated soil and stored in the saturated zone. In SAT, contaminants are removed by physical and biochemical reactions taking place in soils. In this study, a numerical model was developed to predict changes in water quality during SAT operations. The contaminant species considered in the model were ammonium, nitrate, dissolved organic carbon, and dissolved oxygen. The model was calibrated against experimental data obtained from one dimensional soil column tests conducted for 84 days. The calibrated model will be used to find out optimum conditions for the pilot- and regional-scale SAT operations to be scheduled for the next phase of this project.

  • PDF

진동 계측 데이터를 이용한 명동 성당 유한요소 모델 개선 (FE Model Calibration of Myeong-dong Cathedral Using Vibration Measurement Data)

  • 황인환;전진용;김지영
    • 한국소음진동공학회논문집
    • /
    • 제23권11호
    • /
    • pp.987-995
    • /
    • 2013
  • One of the most important processes to accurately predict structural responses is to evaluate accurate structural dynamic characteristics using finite element(FE) models. The numerical structural dynamic characteristics usually show considerable discrepancies with the measured ones because structural details are commonly simplified in the FE models. To identify such discrepancies, FE models of them have been calibrated using the measured dynamic characteristics in previous researches. In this study, the dynamic characteristics were measured for a historic cathedral and the FE model of it was calibrated using the measured results as a reference. Finally, a procedure of the FE model construction for the unreinforced masonry cathedral were tentatively proposed.

Numerical analysis for the punching shear resistance of SFRC flat slabs

  • Baraa J.M. AL-Eliwi;Mohammed S. Al Jawahery
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.425-438
    • /
    • 2023
  • In this article, the performance of steel fiber-reinforced concrete (SFRC) flat slabs was investigated numerically. The influence of flexural steel reinforcement, steel fiber content, concrete compressive strength, and slab thickness were discussed. The numerical model was developed using ATENA-Gid, user-friendly software for non-linear structural analysis for the evaluation and design of reinforced concrete elements. The numerical model was calibrated based on eight experimental tests selected from the literature to validate the actual behavior of steel fiber in the numerical analysis. Then, a parametric study of 144 specimens was generated and discussed the impact of various parameters on the punching shear strength, and statistical analysis was carried out. The results showed that slab thickness, steel fiber content, and concrete compressive strength positively affect the punching shear capacity. The fib Model Code 2010 for specimens without steel fibers and the model of Muttoni and Ruiz for SFRC specimens presented a good agreement with the results of this study.

투과성 해안구조물의 소상파 및 내부수위변동에 관한 수치모델링 (Numerical Modeling of Wave Run-up and Internal Set-up on and in Permeable Coastal Structures)

  • 남인식;김종욱;류청로
    • 한국해양공학회지
    • /
    • 제16권5호
    • /
    • pp.34-40
    • /
    • 2002
  • A numerical model has been developed for the permeable coastal structures to simulate hydraulic characteristics on the permeable slopes, which interact with internal four field the structures. The model includes hydraulics in the porous medium. Numerical model was calibrated using hydraulic model experiments performed in 2-D wave flume in the Institute of Ocean Hydraulics in PKNU. Better aggrements were obtained with the model which employed inertia resistance term than with the conventional model, PBREAK.

투과성해안구조물의 소상파 및 내부수위변동에 관한 수치모델링 (Numerical modeling of wave run-up and internal setup on and in permeable coastal structures)

  • 남인식;윤한삼;김종욱;류청로
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.172-179
    • /
    • 2001
  • A numelical model has been developed for the permeable coastal structures to simulate hydraulic characteristics on the permeable slopes, which interact with internal flow field of the structures. The model includes hydraulics in the porous medium. Numerical model was calibrated using hydraulic model experiments performed in 2-D wave flume in the Institute of Orean Hydraulics in PKNU. Good agreement were obtained with the model which employed inertia resistance term than with the conventional model, PBREAK.

  • PDF