• Title/Summary/Keyword: calculation program

Search Result 1,343, Processing Time 0.028 seconds

Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines (병행 배전선로에서의 통신선 유도전압 계산)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seong-Heon;Kim, Seong-Arm;Weon, Bong-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

A Technique for a Short-Circuit Current Calculation to The Single-Phase Transformer in the Three-Phase Systems (3상계통에서 단상변압기에 대한 단락전류계산 기법)

  • Park, Jae-Hwae;Jin, Tae-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.170-175
    • /
    • 2008
  • This paper describes the exact short-circuit current calculation technique for the single-phase transformer which is installed in the three-phase systems and shorted in the secondary side. Not only the results for a short-circuit current calculation in the existing literatures are wrong, but also little literature deals with the short-circuit current for a single-phase transformer. So, this paper presents a theoretical study and calculation method for a single-phase short current. The validity of the presented method is investigated through Simulation using "Power Tools" and "PSim" program.

Development of Nursing Activity Cost Calculation Program Using Time-Driven Activity-Based Costing (TD-ABC) (병동 간호활동 원가계산 프로그램 개발 :시간동인 활동기준원가계산 기반으로)

  • Lim, Ji Young;Kang, Sung Bae;Lee, Hyun Hee
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.4
    • /
    • pp.480-494
    • /
    • 2018
  • The purpose of this study is to develop a nursing activity cost calculation program based on Lee's doctoral dissertation using TD-ABC. The developed program has been supplemented with data storage, print out, and graph conversion functions to expand the application possibility. The development of the program consisted of three steps: program requirements analysis, program design and development, and program validation. This program was designed not only to do the cost calculation, but also to compare the cost-effectiveness and cost consumption trends. Consequently, this program is meaningful in that the nursing manager can obtain the cost information necessary for nursing unit management and extend the utilization so that the cost management strategy can be established based on the cost information. Therefore, we propose that the cost-management capacity of clinical nurses should be strengthened and the nursing performance measurement research should be expanded by applying it to various actual clinical nursing management settings. It is suggested that this program should be used as a training medium to strengthen nurse cost management capacity by combining nursing management curriculum at undergraduate level.

Dose Calculation for the Buckler Remote Afterloading System (Buchler 강내조사장치의 선량계산에 대한 연구)

  • Chung Weon Kuu;Kim Soo Kon;Kang Jeong Ku;Lee Jeong Ok;Moon Sun Rock;Kim Seung Kon
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.247-253
    • /
    • 1996
  • Purpose : The dose calculation program for the Buckler type remote after-loading system was developed. This program also can be used to calculate dose for various sealed sources. Materials and Methods : We determined the source length and distribution by dividing the program disk to 72 points. The dose rate for the each program disk and source was calculated. The dose rate table for the xy coordinate was established. The dose rate for the interesting points of the patient were calculated by using this table, We also made isodose curve from this calculations. Results : The storage size for the dose rate table were increased. But the calculation of the dose rate for the patient were carried out rapidly. So we could get real time calculation. Conclusion : By using this program, we could calculate the dose rate for the various points of the patient quickly and accurately. This program will be useful for the treatment with various linear sources.

  • PDF

Development and Inspection of the Ortho-Calc v1.0 Program for the Calculation of the Orthometric Correction (정사보정량 계산을 위한 Ortho-Calc v1.0 프로그램의 개발과 검증)

  • Lee, Suk Bae;Sim, Jung Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.3
    • /
    • pp.41-47
    • /
    • 2015
  • To determine the accurate height, it should be considered geometric height difference obtained by levelling as well as the physical height difference what so called orthometric correction. The orthometric correction amount is small enough to ignore at flatland but the amount is big at high mountains, so it should be considered to obtain accurate height at high mountains. But the calculation process is difficult and complex, not easy to calculate. So, to make the process easy using a user-friendly visual, a orthometric correction calculation program Ortho-Calc. v1.0 was developed in this study. This program was adopted the algorithm of Nassar and Hwang & Hsiao, and Strang Van Hees and it could be to selectivily calculate the correction amount. The inspection result exhibited high accuracy with the standard deviation of 0.024mm by the comparison of previous study. Therefore, This program Ortho-Calc. v1.0 developed in this study, will contribute orthometric correction calculation quickly and easily. And, if this program is widely popular, it could be expected to make a contribution the Benchmark's official height renewal using orthometric correction.

The Teaching of Statistics using Excel VBA

  • Choi, Hyun-Seok
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.155-161
    • /
    • 2006
  • To enhance the interest and comprehension of learners studying Statistics. The program which learners can use is needed. With the help of this program, the interest and concentration of the learners can be enhanced, and the effects of the study of Statistics can be maximized, through the convenience of calculation to the theoretical contents of Statistics, various graphs, the, simulation.

  • PDF

Predictors of Drug Calculation Competence of Nursing Students (간호 대학생의 약물계산역량에 영향을 미치는 요인)

  • Kim, Myung Hee;Park, Jung Ha;Kim, Myoung Soo
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.3
    • /
    • pp.174-182
    • /
    • 2012
  • Purpose: The objective of this study was to identify predictors of drug calculation competence of nursing students. Methods: A total of 120 students were recruited from 3 universities from November 10 to 20, 2011. The instruments for this study were drug calculation competence, self-efficacy for drug dosage calculation, anxiety for drug dosage calculation, and the academic self-efficacy scale. The data were analyzed by descriptive analysis, chi-square test, t-test, Scheffe test, partial correlation coefficients, and stepwise multiple regression using the SPSS 18.0 program. Results: The mean score of good competence group was $0.67{\pm}0.08$ and the mean score of no-good competence group was $0.42{\pm}0.10$. The drug calculation competence was positively related to self-efficacy for drug dosage calculation and academic self-efficacy scale, but negatively related to anxiety for drug dosage calculation after controlling personal attributes. The main predictors of drug calculation competence in nursing students were identified as anxiety for drug dosage calculation (${\beta}$=-.25, p=.046), academic self-efficacy (${\beta}$=.19, p=.035). These two factors explained about 10% of variance in drug calculation competence. Conclusion: Based on the results, the strategies reducing the anxiety for drug dosage calculation and improving the academic self-efficacy should be developed and implemented.

Study on the Dose Calculation for Iridium and Cessium Sources (이리듐과 세슘의 혼합선원을 이용한 강내치료의 선량계획에 관한 연구)

  • Kang, Jeong-Ku;Kim, Soo-Kon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.42-46
    • /
    • 2005
  • The Dose calculation program for the Buchler remote after-loading system was developed. We use iridium source for the tandem and cessium for the ovoids. We determined the source length and distributions by dividing the program disk to 72 points. The dose rate for the each program disk were calculated and stored to the tables for the xy coordinates. The dose rate for the interesting points for the patients were calculated by using these tables. We also made isodose curve from the calculations. By using the program, we could calculate the dose rate for the various points of the patient quickly and accurately.

  • PDF