• Title/Summary/Keyword: calculated EMC

Search Result 74, Processing Time 0.025 seconds

Evaluation of the Characteristics of Semi-Anechoic Chamber for the Vertical Polarization (전파발무향심의 수직편파에 대한 특성평가)

  • 김동일;정세모;김민석
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.3
    • /
    • pp.107-115
    • /
    • 1996
  • With the rapid advance of electronic equipments and the frequent, use of them, the electromagnetic environments including EMC or EMI problems are very complicated. The radiation of electromagnetic waves from electronic equipments has strictly been controlled by the authorities concerned from many years ago. Though it is the most proper to test EMI or EMC in the open area test site, we have used the anechoic chamber in place of the test site because of its various restrictions. To achieve the purpose, in this paper, the performances of a few anechoic chambers according to absorbing materials are analyzed for horizontal and vertical polarizations respectively. Furthermore, the calculated and the measured site attenuations in semi-anechoic chamber made with ferrite grid are compared. The obtained results are to be valuable for designing an anechoic chamber.

  • PDF

Space Harmonic Analysis of PM type LSM taking into account Slot by Equivalent Magnetizing Current (등가자화전류를 이용한 영구자석형 선형동기전동기의 슬롯을 고려한 공간고조파해석)

  • Jo, Jae-Ok;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.192-194
    • /
    • 1997
  • This paper propose an efficient space harmonic analysis method for magnetic field. Permanent magnet and primary core considered slot are replaced by EMC(equivalent magnetizing current). And the resultant air gap flux density is calculated by superposition due to the permanent magnet and EMC. We analyze the harmonic distribution of air gap flux density taking into account slot for PMLSM.

  • PDF

Runoff Characteristics of Non-point Pollutant Sources in an Agricultural Area Watershed (농촌지역 비점오염물질의 유출 특성)

  • Ryu, Kwang-Hyun;Lee, Geon-Jik;Seong, Jin-Uk;Kim, Dong-Sup;Park, Jae-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.2
    • /
    • pp.178-186
    • /
    • 2011
  • This study was conducted to investigate runoff characteristics of non-point pollutant sources in an agricultural area watershed in Boeun area, Chungbuk Province. The monitoring site represented 1.56 $km^2$, about 44.4% of which was covered with paddy fields. The monitoring was conducted for six events in a period of 5 month. Event Mean Concentration (EMC) and Site Mean Concentration (SMC) of suspended solids (SS), biochemical oxygen demand (BOD), chemical oxygen demand (COD), total nitrogen (T-N) and total phosphorus (T-P) were calculated using the results of the water quality parameters. A comparison between arithmetic mean concentration and EMC revealed that nearly all EMCs were higher than the corresponding arithmetic mean concentrations. First-flushing effects were exhibited for SS, BOD, and T-P, with relatively high concentrations in early-stage storm events.

Contribution of Non-Point Pollution to Water Quality and Runoff Characteristics from Agricultural Area of the Upstream Watersheds of Lake Chinyang

  • Lee, Chun-Sik;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.259-267
    • /
    • 2013
  • In this study, non-point source(NPS) contribution was investigated based on flow rates and water qualities of streams into the lake during rainfall events. Event mean concentration(EMC) and the pollution loads were calculated to establish a database for NPS control measurement in the survey area, and so on. The runoff characteristics of NPS were investigated and estimated on the basis of the ratio of an agricultural to forest area in the stream of sub-catch basin during rainfall events. Non-point source pollution loads were also calculated to establish a database for NPS control measure in the upstream lake Chinyang. At a rainfall event, BOD concentrations rise sharply at the early peak time of runoff, however, peaks of TSS concentration were observed at the similar time of peak flow. This was a phenomenon shown at the watersheds caused by forest and geological types. The discharged EMC range was 2.9-4.8 mg/L in terms of BOD. The discharged EMC range was 6.2-8.2 mg/L in terms of SS. The discharged EMCs of T-N and T-P were 1.4-2.5 mg/L and 0.059-0.233 mg/L, respectively. Total BOD loading rate through the 3 tributaries to the lake Chinyang was 1,136 kg/d during dry weather. The upper watershed area of the Nam-river dam in this study was divided into 14 catchment basins based on the Korean guideline for total maximum daily load(TMDL) of water quality pollutants. The higher the agricultural land-use ratio, the more NPS loading rate discharged, but the more occupied a forest area, the lower more NPS loading rate discharged. In an agricultural land-use area more than 20%, the increase of NPS loadings might be dramatically diffused by increasing the integrated complex-use like vinyl-house facilities and fertilizer use etc. according to the effective land-use utilization. The NPS loading rates were BOD 0.3 $kg/ha{\cdot}day$, SS 0.21 $kg/ha{\cdot}day$, TN 0.02 $kg/ha{\cdot}day$, TP 0.005 $kg/ha{\cdot}day$ under less than 10% agricultural land-use. In agricultural land-use of 20%-50%, these values were investigated in the range of 0.32 $kg/ha{\cdot}day$-0.73 $kg/ha{\cdot}day$ for BOD, 0.92 $kg/ha{\cdot}day$-3.32 $kg/ha{\cdot}day$ for SS, 0.70 $kg/ha{\cdot}day$-0.90 $kg/ha{\cdot}day$ TN, 0.03 $kg/ha{\cdot}day$-0.044 $kg/ha{\cdot}day$ for TP.

Development of the Design Algorithm Using the Equivalent Magnetic Circuit Method for Colenoid Type Electromagnetic Linear Actuator (등가자기회로를 활용한 콜레노이드 타입 선형 액츄에이터 설계 알고리즘 개발)

  • Han, Dong-Ki;Chang, Jung-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.2
    • /
    • pp.55-61
    • /
    • 2016
  • This study proposes the design algorithm of an electromagnetic linear actuator with a divided coil excitation system, such as the colenoid (COL) system, using the equivalent magnetic circuit (EMC) method. Nowadays, the clamping device is used to hold workpiece in the electrically driven chucking system and is needed to produce a huge clamping force of 40 kN like hydraulic system. The design algorithm for electromagnetic linear actuator can be obtained using the EMC method. At first, the parameter map is used to decide the slot width ratio in the initial design. Next, to make the magnetic flux density uniform at each pole, the pole width is adjusted by the pole width adjusting algorithm with EMC. When the dimensions of the electromagnetic linear actuator are decided, the clamping force is calculated to check the desired clamping force. The design results show that it can be used to hold a workpiece firmly instead of using a hydraulic cylinder in a chucking system.

Characteristics of Non-point Pollutant Discharge from Upper Watershed of Seomjin Dam during Rainy Season (섬진강댐 상류 유역의 강우시 비점오염물질 유출 특성)

  • Kwak, Dong-Heui;Yoo, Seung-Joon;Kim, Ji-Hoon;Lim, Ik-Hyun;Kwon, Ji-Young;Chung, Paul-Gene
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.39-48
    • /
    • 2008
  • This study was carried out to investigate the characteristics of the pollutant discharge from non-point source and to estimate the unit loads of the pollutant discharge from the upper watershed of Seomjin Dam during rainy season. The upper watershed of Seomjin Dam is located in the middle of Jeonbuk province is formed two tributaries mainly. A sub-branch stream of those tributaries is Imsil stream of which flow rate is about 13% of the main stream of Seomjin reservoir normally. On the basis of measurement result in this study, the water quality of Imsil stream was fluctuated highly and the quantity of measured pollutant discharge was higher than the value calculated with the proportion of flow rate during dry season. On the contrary, during rainy season the mean values of flow rate and water quality were higher than the quartile according to the statistical analysis. That means rainfall can influence strongly on the water quality of the upper watershed of Seomjin reservoir. Among the several criteria of water quality, SS discharge was most sensitive to the flow rate variation of stream, which was fluctuated in proportion of rainfall, basically. It was evaluated the event mean concentration (EMC) of non-point source pollutants depending on rainfall events as well. Though the pollutant discharge unit of Imsil stream was lower than the main stream of Seomjin reservoir, the EMC value of Imsil stream was higher than the main stream of Seomjin reservoir.

Characteristics of Water Quantity and Quality of the Anyangcheon using SWAT Model and Calculation Result of EMC (SWAT 모형과 EMC 산정결과를 이용한 안양천의 수량 및 수질 특성)

  • Chung, Eun-Sung;Lee, Kil Seong;Shin, Mun-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.648-657
    • /
    • 2006
  • Characteristics of water quantity and quality of the Anyangcheon were analyzed through many field measurements and the distributed hydrologic simulation model, Soil and Water Assessment Tool (SWAT). Event mean concentrations (EMCs) and baseflow mean concentrations were calculated from the data and the daily runoff were simulated by SWAT. The runoff was divided into the direct runoff and the baseflow. Using those values and quantity and quality data of release from the wastewater treatment plant (WWPT), unit loads of BOD, COD, SS, $NO_2-N$, $NO_3-N$, $NH_3-N$, and Dis-P were derived. EMCs of BOD and SS were even higher than the baseflow mean concentrations. The total runoff from October to April (7 months) of 2004 was just 13.5%, since the rainfall usually is concentrated in summer season. Futhermore BOD and SS were loaded during the event by 50.9% and 70.9%, respectively and over three quarters of total COD, $NO_2-N$, $NO_3-N$, $NH_3-N$, and Dis-P were flowed into the Anyangcheon during the remaining period. Therefore, the efficiency of WWPT for COD, $NO_2-N$, $NO_3-N$, $NH_3-N$, and Dis-P should be intensified from Oct. to Apr. and the runoff quality management of BOD and SS should be planned during the summer season.

Changes of Specific Surface Area of the Steam Exploded Wood (폭쇄처리 목재의 비표면적변화)

  • Yang, Jae-Kyung;Kim, Hyun-Jung;Lee, Weon-Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.54-60
    • /
    • 1995
  • This paper reports on the changes of equilibrium moisture contents and specific surface areas of Poplar wood(Populus euramericana) for various steam explosion treatments. Equilibrium moisture contents(EMC) and specific surfaces of steam exploded woods were measured under the moisture adsorption course at 25$^{\circ}C$, and compared with those of other materials and wood meals. The EMCs of steam exploded wood meal were 1~5% less in comparison with that of wood meal. In the case of delignified steam exploded wood meal and delignified wood meal, the same tendency was appeared too. But absolute values of EMCs for delignified wood meals were larger than those of the wood meal. For the changes of EMC by the steam exploded conditions, the EMC decreased with the increase of the steam explosion pressure. On the other hand, specific surface areas were calculated from BET plots based on amounts of monomolecular vapor adsorption of various wood meals. Specific surface areas of the wood meal and delignified wood meal were 90~145, 34~90($m^2/g$) respectively, and which were greater in comparison with those of steam exploded wood meals and delignified steam exploded wood meals. From these results, it is considered that the amount of water vapor adsorption was decreased by the increase of the crystallinity, effect of heat treatment, and coating by melted lignin in during the steam explosion.

  • PDF

A Study on the Evaluating Characteristics of EM Wave Absorber for Noise Suppression from PCB (PCB상의 노이즈 제거용 전파흡수체의 특성 평가에 관한 연구)

  • Kim, Dong-Il;Choi, Dong-Soo;Yoon, Sang-Gil;Yoo, Gun-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.6
    • /
    • pp.509-515
    • /
    • 2009
  • In this paper, we analyzed and evaluated noise suppression characteristic of EM wave absorber. We fabricated several absorber samples in different ratios of Sendust and Amorphous with CPE(Chlorinated Ploy-ethylene) as binder and calculated material constants by measured S-parameter. Then, we confirmed that the noise suppression characteristic of EM wave absorbers using microstrip line. A microstrip line with EM wave absorber placed on its top was used to evaluate the conduction noise suppression. As a result, noise suppression effect show different charateristic by changing relative permeability. Therefore, EM wave absorber using Sendust show excellent characteristic. In particular the maximum power absorption over 90 % in 1.7 GHz to over 6 GHz has obtained when composition of Sendust:CPE=80:20wt.%.

A Study on the Estimation Methods of Nonpoint Pollutant Unit Load - Focus on Nonpoint Pollutant Unit Load in Paddy Field - (비점오염 발생 원단위 산정방법에 대한 고찰 - 논 비점오염 원단위를 중심으로 -)

  • Choi, DongHo;Choi, Soon-Kun;Kim, Min-Kyeong;Hur, Seung-Oh;Hong, Sung Chang;Yeob, So-Jin;Yoon, KwangSik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.15-22
    • /
    • 2019
  • In order to preserve water environment, Total Maximum Daily Load(TMDL) is used to manage the total amount of pollutant from various sources, and the annual average load of source is calculated by the unit load method. Determination of the unit load requires reliable data accumulation and analysis based on a reasonable estimation method. In this study, we propose a revised unit load estimation method by analyzing the unit load calculation procedure of National Institute of Environment Research(NIER) method. Both methods were tested using observed runoff ratio and water quality data of rice paddy fields. The estimated values with the respective NIER and revised NIER methods were highly correlated each other. However, the Event Mean Concentration(EMC) and the runoff ratio considered in the NIER method appeared to be influenced by rainfall classes, and the difference in unit load increases as the runoff and EMC increase. The error can be further increased when the EMC and runoff ratio are changed according to changes in rainfall patterns by climate change and change of agricultural activities. Therefore, it is recommended to calculate unit load by applying the revised NIER method reflecting the non point pollution runoff characteristics for different rainfall classes.