초전도 전력케이블의 전력계통 적용을 위한 고장전류 특성에 관한 연구 (A Study on the Fault Current Characteristics for the Utility Application of HTS Power cable)

  • 김재호;박민원;심기덕;조전욱;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.75-76
    • /
    • 2007
  • Several kinds of High Temperature Superconducting(HTS) power cables have already been developed and evaluated for use in the utility power network. HTS power cable is expected to be used as a very powerful energy delivery system supplying electric power for densely populated cities in the near future, because HTS power cable is capable of the high current density delivery with low AC loss and the size effect comparing with the conventional cable whose capacity is same. Before applying the HTS power cable to real utility network system analysis should be carried out by some simulation tools. Hereby the electrical power system analysis is very important for the practical use of HTS power devices. In this paper, authors propose a real-time simulation method which incorporates a real HTS tapes into the simulated 22.9kV utility power network system using Real Time Digital Simulator(RTDS). For the simulation analysis, a test sample of HTS tapes was actually manufactured, and the transient phenomenon of HTS power cable system was analyzed in the simulated utility power network.

  • PDF

DTS를 활용한 광복합 지중 배전계통 실시간 감시시스템 개발 및 성능평가 (A Development and Performance Assessment of On-Line Monitoring System for Optical Fiber Composite Underground Distribution Network using DTS)

  • 조진태;김주용;이학주;조휘창;최명호
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.115-121
    • /
    • 2011
  • Intelligent distribution equipment is inevitable to realize self-healing which is one of smart grid functions in distribution network. Therefore, most of distribution equipment have been developed with self diagnostic sensors. However, it is not effective to construct on-line monitoring system for underground distribution cable because of high cost and low sensitivity. Recently, optical fiber composite cable is being considered for communication and power delivery in order to cope with increasing communication in distribution network. This paper presents the design and performance assessment results of underground cable on-line monitoring system using DTS(Distributed Temperature Sensing) and optical fiber composite underground cable.

WPTS BLE 비콘 기반 센서 네트워크 구축 방안 연구 (Study on the Building Method of a Sensor Network based on BLE Beacons with WPTS)

  • 장호덕
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.8-13
    • /
    • 2022
  • 본 논문에서는 RF (Radio Frequency) 에너지 하베스팅 센서 노드의 설계 방안과 CATV 망과 누설 동축 케이블 (leaky coaxial cable)을 활용한 센서 네트워크 구축 방안을 연구하였다. 센서 노드는 915MHz 주파수 대역에서 동작하는 WPTS (Wireless Power Transfer System) 전력 수신기로 전원공급부를 설계하였다. WOC (WiFi over Coax) 기술을 활용하여 CATV 망으로 센서의 BLE 무선통신 신호와 WPTS 전력 송신기 신호를 전송하고, 누설 동축 케이블로 RF 신호를 방사시키는 센서 네트워크 구축 방안을 제안하였다. 센서 네트워크를 구축하는 지점에 누설 동축 케이블을 활용하면 센서 노드의 수신 신호 강도 지표가 허용되는 최소값 (-78dBm)을 만족하는 지점까지 센서 네트워크의 커버리지를 확장할 수 있다.

Dynamic deflection monitoring method for long-span cable-stayed bridge based on bi-directional long short-term memory neural network

  • Yi-Fan Li;Wen-Yu He;Wei-Xin Ren;Gang Liu;Hai-Peng Sun
    • Smart Structures and Systems
    • /
    • 제32권5호
    • /
    • pp.297-308
    • /
    • 2023
  • Dynamic deflection is important for evaluating the performance of a long-span cable-stayed bridge, and its continuous measurement is still cumbersome. This study proposes a dynamic deflection monitoring method for cable-stayed bridge based on Bi-directional Long Short-term Memory (BiLSTM) neural network taking advantages of the characteristics of spatial variation of cable acceleration response (CAR) and main girder deflection response (MGDR). Firstly, the relationship between the spatial and temporal variation of the CAR and the MGDR is described based on the geometric deformation of the bridge. Then a data-driven relational model based on BiLSTM neural network is established using CAR and MGDR data, and it is further used to monitor the MGDR via measuring the CAR. Finally, numerical simulations and field test are conducted to verify the proposed method. The root mean squared error (RMSE) of the numerical simulations are less than 4 while the RMSE of the field test is 1.5782, which indicate that it provides a cost-effective and convenient method for real-time deflection monitoring of cable-stayed bridges.

역전파 신경망을 이용한 케이블의 색깔인식 (Cable Color Recognition Using a Back-Propagation Neural Network)

  • 이문규;윤찬균
    • 산업공학
    • /
    • 제8권1호
    • /
    • pp.5-13
    • /
    • 1995
  • Automated vision inspection has become a vital part of computer related industries. Most of the existing inspection systems mainly utilize black and white images. In this paper, we consider an application of automated vision inspection in which cable color has to be recognized in order to detect the quality status of assembled wire harness. A back-propagation neural network is proposed to classify seven different cable colors. To represent a single point in image space, we use the ($L^*,\;a^*,\;b^*$) model which is one of commonly used color-coordinate systems in image processing. After training the neural network with ($L^*,\;a^*,\;b^*$) data obtained from color image, we tested its performance. The results show that the neural network is able to classify cable colors with high performance.

  • PDF

철도 광케이블을 이용한 화상전송방안에 관한 연구 (A study on the moving picture transmission method by railway fiber optics cable)

  • 조봉관;장석각;류상환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.468-473
    • /
    • 2003
  • CCTV network has been implemented to transmit the image information of platfo gate and transfer section to local headquarters in the KNR(Korean National Railroa But. communication system for transferring image information around accident field has not been established yet. thus, at present implementation of communication equipment is necessary for dyn of unspecified accident to be transmitted to headquarters. Copper cable communication network is run by KNR, but it is processing installatio optics cable in connection with the implemental plan for high-speed network from n And, the capacity of communication channel will be guaranteed much more than een station and station, station and central headquarters when fiber optics cable is This study analyzes the image equipment of field for transmission and estimated m transmit image information of accident field to headquarters with using communicat ucture. And, the study considers implemental method of communication network for nce image transmission from dozens to hundreds kilometers.

  • PDF

스마트 폰을 이용한 광 통신망 감시 시스템 (Optical Network Monitoring System Using Smart Phone)

  • 정소기
    • 한국통신학회논문지
    • /
    • 제42권1호
    • /
    • pp.218-226
    • /
    • 2017
  • 본 논문은 스마트 폰을 활용하여 광 전송망 구간을 실시간으로 감시하는 시스템이다. 기존의 광 통신망 구간은 스마트 폰과 접속함체의 여장판에 스위치 설치를 활용하여 현장의 상황을 실시간으로 인지 하는 시스템이 없었다. 본 연구는 스마트 폰의 Application과 접속함체 스위치를 이용하여 실시간으로 유지보수를 할 수 있도록 했다. 스마트 폰 Web은 접속함체 장애 위치를 찾는데 유용하며, 접속함체 내부에 있는 여장판 벨크로 타이를 분리하면 스위치가 작동하여 심선의 밴딩을 주어서push message를 발생하게 한다. 접속함체 작업과 장애가 발생하면 스마트폰을 이용하여 OTDR측정을 하여 위치 추적을 할 수 있도록 하는 연구이다. 스마트 폰을 이용하여 실시간 광케이블 구간을 관리함으로써 장애 시간 단축과 전송망 품질을 효율적으로 유지보수 할 수 있다.

전력회사 계통에 22kV급 초전도 케이블 도입을 위한 적용 개소 고찰 (A Study on the Application of 22kV class Superconducting Cable in Utility Network)

  • 김종율;윤재영;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.20-29
    • /
    • 2003
  • As power systems grow more complex and power demands increase, the need of underground transmission system is increasing gradually. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable can carry very high current densities with strongly reduced conductor loss and allow high power transmission at reduced voltage. Therefore HTS cable can transfer more power to be moved in existing ducts, which means very large economical and environmental benefits. A development project for a 22kV class HTS cable is ongoing at a research centers, and the cable manufacturer in Korea. In this paper, we carried out investigation for application of 22kV class HTS cable in Korean utility networks. The results show that the HTS cable is applicable to replace IPB in pumping-up power plant, withdrawal line in distributed generation, withdrawal line in complex power plant, and conventional under ground cable. Finally, as the cost of HTS wire and refrigeration drops, the technical and economical potential of HTS cable is evaluated positively.

A novel method for vehicle load detection in cable-stayed bridge using graph neural network

  • Van-Thanh Pham;Hye-Sook Son;Cheol-Ho Kim;Yun Jang;Seung-Eock Kim
    • Steel and Composite Structures
    • /
    • 제46권6호
    • /
    • pp.731-744
    • /
    • 2023
  • Vehicle load information is an important role in operating and ensuring the structural health of cable-stayed bridges. In this regard, an efficient and economic method is proposed for vehicle load detection based on the observed cable tension and vehicle position using a graph neural network (GNN). Datasets are first generated using the practical advanced analysis program (PAAP), a robust program for modeling and considering both geometric and material nonlinearities of bridge structures subjected to vehicle load with low computational costs. With the superiority of GNN, the proposed model is demonstrated to precisely capture complex nonlinear correlations between the input features and vehicle load in the output. Four popular machine learning methods including artificial neural network (ANN), decision tree (DT), random forest (RF), and support vector machines (SVM) are refereed in a comparison. A case study of a cable-stayed bridge with the typical truck is considered to evaluate the model's performance. The results demonstrate that the GNN-based model provides high accuracy and efficiency in prediction with satisfactory correlation coefficients, efficient determination values, and very small errors; and is a novel approach for vehicle load detection with the input data of the existing monitoring system.

Development of innovative superconducting DC power cable

  • Matsushita, Teruo;Kiuchi, Masaru
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권3호
    • /
    • pp.1-7
    • /
    • 2017
  • It is required to reduce the cost of superconducting cable to realize a superconducting DC power network that covers a wide area in order to utilize renewable energy. In this paper a new concept of innovative cable is introduced that can enhance the current-carrying capacity even though the same superconducting tape is used. Such a cable can be realized by designing an optimal winding structure in such a way that the angle between the tape and magnetic field becomes small. This idea was confirmed by preliminary experiments for a single layer model cable made of Bi-2223 tapes and REBCO coated conductors. Experiments of three and four layer cables of practical sizes were also done and it was found that the current-carrying capacity increased as theoretically predicted. If the critical current properties of commercial superconducting tapes are further improved in a parallel magnetic field, the enhancement will become pronounced and this technology will surely contribute to realization of superconducting DC power network.