• Title/Summary/Keyword: cable length

Search Result 372, Processing Time 0.032 seconds

An Improved Initial Force Method for Determining the Initial Configuration of Suspension Bridges (현수교 시스템의 초기형상 결정을 위한 개선된 초기부재력법)

  • Kim, Min;Kim, Ho-Kyung;Kim, Moon-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.237-247
    • /
    • 2011
  • This paper presents an improved initial force method for determining the initial shape of suspension bridges. After determining the initial shape factors through the force equilibrium conditions of each hanging point, the initial force method was applied with the computed values, each node's coordinates, and unstrained lengths of the cable element as inputs. The unstrained length of each cable element was regarded as a fixed value in each iteration step, unlike in the typical initial force method. This method can be applied to 2D and 3D suspension bridge models. The validity of the present method was demonstrated by comparing the results of the numerical examples.

A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway (전철 지중배전선로의 충전전류보상에 관한 연구)

  • Kim, Yang-Su;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

Explosion Shock Measurement System of the Precursor Warhead for the Tandem Projectile (탠덤 비행체의 선구탄두 기폭 충격 측정 시스템 구현)

  • Choi, Donghyuk;An, Jiyeon;Kim, Yubeom;Son, Joongtak;Lee, Ukjun;Park, Hyunsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.503-510
    • /
    • 2021
  • This paper presents a system that measures the acceleration of the shock caused by the explosion of the precursor warhead for the tandem projectile. The proposed system, which is implemented based on the MIL-STD-810G, Method 517.1, consists of a miniaturized shock measurement device, a cable, accelerometers, and a trigger circuit. The shock measurement device has a size of ¢102 × 171 mm and cable has a length of 3 m. The operational confirmation test is conducted by implementing the measurement system. The Analysis of shock data(accelerometer output data) is carried out using Shock Response Spectrum(SRS), pseudo velocity and plot of acceleration time transient. Through measurement analysis, one can predict the damage of electronics in projectile when precursor warhead is exploded.

Temperature Measurement System for Refrigerated Vehicle (냉동차량을 위한 온도 측정 시스템)

  • Lim, Yong-Jin;Kim, Jung-Hwan;Lim, Joon-hong
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.159-163
    • /
    • 2019
  • The food service industry has been grown due to improvement of living standards. In addition, the demand for frozen food delivery is increasing day by day at online/offline and the refrigerated vehicles are used in most of these food distributions. One of the most important factors in a refrigerated car is to measure the temperature accurately. Conventional temperature recording systems are generally connected directly to temperature sensor modules. Since the temperature data are transmitted to the temperature recorder by using the electric wire, there is a disadvantage that the resistance error must be compensated according to the cable length. In this paper, we propose a method to correct errors due to cable resistance using digital processing and CAN (Controller Area Network) communication. We use PT-1000 platinum sensor to increase the accuracy of the temperature measurement.

Development of CICC for KSTAR PF coil system (KSTAR PF 코일 시스템을 위한 CICC 제작)

  • B. Lim;S. Lee;J. Choi;J. Kim;Y. Chu;H. Park;M. Kim;S. Baang;W. Chung
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.306-309
    • /
    • 2002
  • A superconducting CICC (Cable-In-Conduit-Conductor) is adopted the KSTAR (Korea Superconducting Tokamak Advanced Research) superconducting magnet system which consists of 16 TF coils and 14 PF coils. For the test of KSTAR CICC, an ambient magnetic field of $\pm$ 8 T With a maximum change rate of 20 T/s is required and a background-field magnet system is being developed for SSTF (Samsung Superconductor Test Facility). The CICC for PF1~5 is used as the conductor for background-field coils to check the validity of the PF CICC design. Two pieces of cables have been fabricated and the cable has the length of 870 m and the diameter of 20.3 mm. A continuous CICC jacketing system is developed for the KSTAR CICC fabrication and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The design specification of CICCs and the fabrication process is described.

  • PDF

Analysis of PCI Cable Effects in HEMP Conducted Disturbance (HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석)

  • Jang, Tae-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.772-780
    • /
    • 2013
  • The high-altitude electromagnetic pulse(HEMP) conducted environment and the HEMP radiated environment are established as the consequences of a high-altitude nuclear explosion. The IEC 61000-2-10, the international standard, defines the HEMP conducted environment. The IEC 61000-5-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. The IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. The IEC 61000-4-24:1997 mainly describes the measurement method of small protective components. However, it does not provide the measurement method for a combination filter of a protective component and a filter which is widely used in recent. It is important to consider the characteristic of the measurement setup parameters like thickness and length of the cable and its height above ground plane etc. in establishing measurement setup because HEMP conducted disturbances include the frequency spectrum below 50 MHz. This paper deals with the optimized measurement method, considering the frequency spectrum of HEMP conducted disturbance, current waveform, and analyzing the effects of cables existing in the measurement setup.

Beach-chair lateral traction position using a lateral decubitus distracter in shoulder arthroscopy

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.164-164
    • /
    • 2008
  • The beach-chair traction position is designed to allow the use of traction while allowing the surgeon to orient the shoulder in an upright position and convert to an open procedure, if necessary. The patient is placed in the beach-chair position under general anesthesia. A three-point shoulder holder (Arthrex, Naples, Florida) is attached to the rail of the operating table on the same side as the surgeon, whereas it is placed on the side opposite the surgeon in the lateral decubitus position. A shoulder traction and rotation sleeve (Arthrex) are affixed to the arm following the manufacturer's instructions. Positioning the thumb toward the closed side of the sleeve ensures a field for the anterior portion of the rotator cuff and prevents the tendency of the suspension apparatus to place the arm in internal rotation. The arm is maintained in 30 to 40 degree abduction and 30 to 40 degree flexion by controlling the length and height of the bar and the location of the universal clamp. The universal clamp allows multiple planes of adjustment to control abduction and forward movement of the arm. The sleeve is attached to the longitudinal traction cable using a sterile hook, and a lateral strap is secured around the proximal portion of the sleeve to the overhead traction cable to ensure a field for glenohumeral reconstruction. The use of a lateral strap permits ideal shoulder positioning for improved access to the anterior and inferior glenohumeral joint. The lateral strap can be released or removed to widen the subacromial space during subacromial decompression or rotator cuff repair. A 10-lb weight is attached to the longitudinal traction cable for an average-sized person.

  • PDF

Distribution Characteristics of Irregular Voltage in Stator Windings of IGBT PWM Inverter-Fed Induction Motors (IGBT PWM 인버터 구동 유도전동기 고정자 권선에서의 과도전압 분포특성)

  • 황돈하;김용주;이인우;배성우;김동희;노체균
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.351-358
    • /
    • 2003
  • This paper describes distribution characteristics of switching surge voltage in stator windings of induction motor driven by IGBT PWM inverter. To analyze the voltage distribution between the turns and coils of stator winding, equivalent circuit model of induction motor including cable was proposed and high frequency parameter is computed by using finite-element method (FEM). From the electro-magnetic transient program (EMTP) simulation of the whole system for induction motor, feeder cable, and PWM inverter, the variable effect on rising time of the inverter, cable length, and switching frequency on the voltage distribution is also presented. In order to experiment, an induction motor, 380[V], 50[HP], with taps from one phase are built to consider the voltage distribution so that these results can be helpful when filter was designed to remove high dv/dt.

Characteristics of Coaxial Typed Magnetic Sensor Using Amorphous Wire (자성와이어를 이용한 동축케이블형 자계센서의 특성)

  • Kim, Y.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.55-59
    • /
    • 2007
  • Co-based amorphous magnetic wire with a diameter of $125{\mu}m$ and a length of 40 mm was used as an inner conductor of a coaxial cable to construct a magnetic sensor. Sensor characteristics was measured up to 3 GHz with applied up to 60 Oe by using network analyzer. Frequency dependence of impedance for this sensor was very close to the impedance resonant pattern of transmission line and 250 MHz was obtained as a 1/4 wavelength without external magnetic field. Large impedance change was measured in the magnetic field range between 0 Oe and 1 Oe, which was influenced by permeability change of magnetic amorphous wire. Because ${\Delta}Z/{\Delta}H$ value of $300{\Omega}/Oe$ was obtained at 0.1 Oe, this coaxial cable with amorphous wire can be useful as a magnetic sensor.

Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System (초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석)

  • Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.