• 제목/요약/키워드: c-type dislocation

검색결과 41건 처리시간 0.019초

Microstructure and Mechanical Property of Irradiated Zr-2.5Nb Pressure Tube in Wolsong Unit-1

  • 김영숙;안상복;오동준;김성수;정용무
    • 소성∙가공
    • /
    • 제8권3호
    • /
    • pp.241-241
    • /
    • 1999
  • With the aim of assessing the degradation of Zr-2.5Nb pressure tubes operating in the Wolsong unit-1 nuclear power plant, characterization tests are being conducted on irradiated Zr-2.5Nb tubes removed after 10-year operation. The examined tube had been exposed to temperatures ranging from 264 to 306℃ and a neutron fluence of 8.9×$10^{21}$ n/cm²(E>1 MeV) at the maximum. Tensile tests were carried out at temperatures ranging from RT to 300℃. The density of a-type and c-type dislocations was examined on the irradiated Zr-2.5Nb tube using a transmission electron microscope. Neutron irradiation up to 8.9×$10^{21}$ n/cm²(E>1 MeV) yielded an increase in a-type dislocation density of the Zr-2.5Nb pressure tube to 7.5×$10^{14} m^{-2}$, which was highest at the inlet of the tube exposed to the low temperature of 275℃. In contrast, the c-component dislocation density did not change with irradiation, keeping an initial dislocation density of 0.8×$10^{14} m^{-2}$ over the whole length of the tube. As expected, the neutron irradiation increased mechanical strength by about 17-26% in the transverse direction and by 34-39% in the longitudinal direction compared to that of the unirradiated tube at 300℃. The change in the mechanical properties with irradiation is discussed in association with the microstructural change as a function of temperature and neutron fluence.

견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술 (Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture)

  • 김진섭;전진호;정영기
    • Clinics in Shoulder and Elbow
    • /
    • 제2권2호
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

MOCVD방법으로 InP 기판 위에 성장시킨 InAs 박막에서의 부정합 전위 생성 연구 (A Study on Misfit Dislocation Generation in InAs Epilayers Grown on InP Substrates by Metalorganic Chemical-Vapor Deposition)

  • 김좌연;윤의중;박경순
    • Applied Microscopy
    • /
    • 제27권4호
    • /
    • pp.483-488
    • /
    • 1997
  • A misfit dislocation generation in InAs epilayers grown on (001) InP substrates (oriented $2^{\circ}$ off (001) toward the [110] direction) using metalorganic chemical-vapor deposition was studied. The InAs film of 17 nm thickness grown at $405^{\circ}C$ showed the three different arrays of dislocations: a straight orthogonal array to the <110> direction, an array to the >100> direction, and an array tilted by a degree of $5\sim45^{\circ}$ from the [110] direction. All of the dislocations had a/2<101> Burgers vectors inclined $45^{\circ}$ to the interface. Upon annealing at $660^{\circ}C$ the InAs films with 60, 140 and 220 nm thicknesses, most of the misfit dislocations became the Lomer type $(\sim100%)$ oriented exactly along the >110> direction. These misfit dislocation spacings were decreased with increasing the InAs thickness up to 220 nm thickness. This phenomena was interpreted by the relationship between the dislocation interaction energy among parallel misfit dislocations and the opposite remnant InAs epilayer strain energy. The distance between misfit dislocations was measured by transmission electron microscopy.

  • PDF

KOH Etching을 통한 4H-SiC Epitaxy 박막에서의 전위결함 거동 (Characterization of Dislocations in 4H-SiC Epitaxy Using Molten-KOH Etching)

  • 신윤지;김원정;문정현;방욱
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.779-783
    • /
    • 2011
  • The morphology of etch pits in commercial 4H-SiC epi-wafer were investigated by molten-KOH etching. The etching process was optimized in $525{\sim}570^{\circ}C$ at 2~10 min and the novel type of etch pits was revealed. This type of etch pits have been considered as TED (threading edge dislocation) II, its origin and nature, however, are not reported yet. In this work, the morphology and evolution of etch pits during epitaxial growth were analyzed and the different behavior between TED and TEDII was discussed.

Microstructural Characteristics of the Fuel Cladding Tubes Irradiated in Kori Unit 1

족관절의 골절-탈구에 대한 임상적 고찰 (The Clinical Study of Ankle Fracture and Dislocation)

  • 김지훈;송재광;서진수
    • 대한족부족관절학회지
    • /
    • 제17권3호
    • /
    • pp.182-188
    • /
    • 2013
  • Purpose: We evaluate clinical manifestations and radiologic features of ankle fracture & dislocation, as well as the usefulness of computed tomography on posterior ankle fracture & dislocation to study factors contributing to ankle fracture & dislocation. Material and Methods: Ankle dislocation was defined as the center of talar body being translated over the cortex of tibia on AP or lateral view on simple X-ray. Surgical treatments of 30 patients from January 2007 to March 2012 were categorized according to the injury mechanism, the direction of dislocation and fracture site. Joint involvement of posterior malleoalr fracture was evaluated through simple x-ray and computed tomography. We treated surgically if posterior malleolus fracture involves more than 25% of dital tibial articular surface. Thereafter, clinical outcomes were identified through radiographs and by using the AOFAS score. Results: The mean age was 42(13-78) years old, and slip down was the most common injury mechanism (13 cases). Car accident (6 cases) and fall accident (4 cases) were the next frequently found injury mechanisms. As for the types of ankle fracture, posterior fracture and dislocation (21 cases, 43.3%) was most commonly found. Out of these 21 cases, 15 cases involved trimalleolar fracture, and 19 cases were associated with posterior malleolar fracture. Danis-weber type B and C patients were 11 cases and 10 cases respectively. Articular involvement of posterior malleolar fracture turned out to be average 27.9%(5.1%~49.1%) on simple x-ray. The rate was evaluated as average 31.7%(12.6%~55.3%) on computed tomography which was conducted 15 times, and led us to more meaningful data. Conclusion: Anterolateral fracture and dislocation often accompanied open dislocation. Posterior fracture dislocation was most commonly found. Posterior malleolus was an important factor that ensures posterior stability of the ankle joint. Computed tomograph is useful to evaluate the articular involvement of posterior malleolar fracture.

고에너지비소 이온 주입후 2단계 열처리시 2차결함에 대한 연구 (A Study on Secondary Defects in Silicon after 2-step Annealing of the High Energy $^{75}AS^+$ Ion Implanted Silicon)

  • 윤상현;곽계달
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.796-803
    • /
    • 1998
  • Intrinsic and proximity gettering are popular processes to get higher cumulative production yield and usually adopt multi-step annealing and high energy ion implantation, respectively. In order to test the combined processed of these, high energy \ulcornerAs\ulcorner ion implantation and 2-step annealing process were adopted. After the ion implantation followed by 2-step annealing, the wafers were cleaved and etched with Wright etchant. The morphology of cross section on samples was inspected by FESEM. The concentration profile of As was measured by SRP. The location and type of secondary defects inspected by HRTEM were dependent on the 1st annealing temperatures. That is, a line of dislocation located at $1.5mutextrm{m}$ apart from the surface at $600^{\circ}C$ lst annealing was changed to some dislocation lines or loops nearby the surface at 100$0^{\circ}C$. The density of dislocation line was reduced but the size of the defects was enlarged as the temperature increased.

  • PDF

중수로 압력관 재료의 조사 열화에 따른 인장거동 특성 (Tensile Behavior Characteristics of CANDU Pressure Tube Material Degraded by Neutron Irradiations)

  • 안상복;김영석;김정규
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.188-195
    • /
    • 2002
  • To investigate the degradation of mechanical properties induced mainly by neutron irradiation, the tensile tests were conducted from room temperature to 300\\`c using the irradiated and the unirradiated Zr-2.5Nb pressure tube materials. The irradiated longitudinal and transverse specimens were collected from the coolant inlet, middle, and outlet parts of M-11 tube which had been operated in Wolsung CANDU Unit-1 and exposed to different operating temperatures and irradiation fluences. The different tensile behavior was characterized not by the fluences of irradiation but by the tensile loading direction. The transverse specimen showed the higher strength and lower elongation than those of the longitudinal one. It was believed that these phenomena resulted from the microstructure anisotropy caused by the extrusion process. The increased strength hardening and decreased elongation embrittlement of the irradiated material were compard to those of the unirradiated one. While the tensile strength of the inlet was higher than that of the outlet, the elongation of the inlet was lower than that of outlet. Considering the operation condition, it was proposed that the operating temperature could be a more effective parameter than the irradiation fluence for long-time life. Through the TEM observation, it was found that while the a-type dislocation density was increased, the c-type dislocation was not changed in the irradiated. The fact that the higher dislocation density was sequentially distributed over the inlet, the middle, and the outlet parts was consistent with the distribution of the tensile strength.

급성 제 5형 견봉쇄골관절 탈구의 치료 (Acute Type V Acromioclavicular Injury Treated by the Modified Bosworth Technique)

  • 김승기;이상훈;박종범;박원종;장일석;장 한
    • Clinics in Shoulder and Elbow
    • /
    • 제2권2호
    • /
    • pp.126-132
    • /
    • 1999
  • Purpose : To evaluate the functional and radiographic outcome of the modified Bosworth method in the surgical treatment of acute type V acromioclavicular joint dislocation. Materials and Methods: From June 1995 to May 1998, 20 patients were operated on for acute and complete acromioclavicular dislocation(Rockwood type V). The operative technique includes fixation of the coracoclavicular joint with Bosworth screw or 6.5mm cancellous screw and imbrication of trapezius and deltoid muscles. The average age was 34 years(range, 19 to 51 years). These 20 patients with an average follow-up of 18months, were evaluated clinically using the UCLA scoring system. Additional radiographical assessment was performed with stress radiographs. Results: Excellent or good clinical results were obtained in 95%(19 cases). And the average coracoclavicular interval ratio was decreased from 3.31(2.2-6.0) to 1.13(1-1.4) in stress radiographs. There were 4 cases of hetero­topic calcification postoperatively but there was no correlation with clinical result. Posttraumatic A-C joint arthritis was developed in one case. In that case, the distal clavicular resection was done under the arthroscopic technique. Conclusion: The severe displacement observed with type V injuries is incompatible with normal shoulder function if the shoulder is left in its displaced position. In type V injuries, significant damage to the deltoid and trapezius musculature and overlying fascia occurs, therefore open reduction and good fixation must be obtained with imbrication of trapezius and deltoid muscles. In our type V acute complete acromioclavicular dislocation, the modified Bosworth technique provides excellent results with a low complication rate.

  • PDF

Reproducing kernel based evaluation of incompatibility tensor in field theory of plasticity

  • Aoyagi, Y.;Hasebe, T.;Guan, P.C.;Chen, J.S.
    • Interaction and multiscale mechanics
    • /
    • 제1권4호
    • /
    • pp.423-435
    • /
    • 2008
  • This paper employs the reproducing kernel (RK) approximation for evaluation of field theory-based incompatibility tensor in a polycrystalline plasticity simulation. The modulation patterns, which is interpreted as mimicking geometrical-type dislocation substructures, are obtained based on the proposed method. Comparisons are made using FEM and RK based approximation methods among different support sizes and other evaluation conditions of the strain gradients. It is demonstrated that the evolution of the modulation patterns needs to be accurately calculated at each time step to yield a correct physical interpretation. The effect of the higher order strain derivative processing zone on the predicted modulation patterns is also discussed.