Aging of Solid Fuels Composed of Zr and ZrNi Part 1: Thermal/Chemical/Spectroscopic Analysis (Zr과 ZrNi로 구성된 고체연료의 노화 연구 Part 1: 열/화학/분광학적 분석)

  • Han, Byungheon;Ryu, Jihoon;Yang, Junho;Oh, Juyoung;Gnanaprakash, K.;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.2
    • /
    • pp.1-13
    • /
    • 2020
  • The characterization of aging of the pyrotechnic device is conducted thermally, chemically, and spectroscopically. The device is comprised of two parts: (i) igniter composed of Zr and (ii) pyrotechnic delay composed of ZrNi alloy. The thermally induced chemical reaction is identified through Differential Scanning Calorimetry (DSC) and Thermogravimetry Analysis (TGA). The peak deconvolution of the themo-chemical data is used to estimate the enthalpy change of each metallic fuel component. Laser Induced Breakdown Spectroscopy (LIBS) and X-ray Photoelectron Spectroscopy (XPS) are used for chemical species analysis. The decomposition of oxidants by moisture significantly affected the fuel aging, and the formation of oxide film and metal oxide on the fuel surface gave rise to the thermal energy decrease.

A Case of Cavitary Lung Lesion as a Consequence of Smoke Inhalation Injury (흡입화상 치료과정에서 생긴 공동성 폐 병변)

  • Shin, Hyun Won;Kim, Cheol Hong;Eom, Kwang Seok;Park, Yong Bum;Jang, Seung Hun;Kim, Dong Gyu;Lee, Myung Goo;Hyun, In-Gyu;Jung, Ki-Suck;Lee, Eil Seong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.5
    • /
    • pp.564-570
    • /
    • 2006
  • Toxic gases and soot deposition as a consequence of smoke inhalation can cause direct injury to the upper and lower airways and even to the lung parenchyma. A delay in proper and prompt therapy can be detrimental to critically ill burn patients with an inhalation injury. Therefore, serial chest radiography is an important diagnostic tool for pulmonary complications during treatment. The radiographic findings of the chest include normal, consolidation, interstitial and alveolar infiltrates, peribronchial thickening, atelectasis, cardiogenic and non-cardiogenic pulmonary edema, and a pneumothorax as acute complications of smoke inhalation. In addition, bronchiectasis, bronchiolitis obliterans and pulmonary fibrosis can occur as late complications. We encountered a case of 44-year-old male who presented with acute lung injury after an inhalation injury. He required endotracheal intubation and mechanical ventilation due to respiratory failure. He was managed successfully with conservative treatment. Later, a cavitary lesion of the left upper lobe was observed on the chest radiography and computed tomography, which was complicated by massive hemoptysis during the follow-up. However, the cavitary lesion disappeared spontaneously without any clinical consequences.

The Performance of the Combined Operation of Sprinkler and Smoke Curtain for Smoke Control in the Sloped Stairway Corridor (경사통로로 전파되는 연기에 대한 스프링클러와 제연커텐의 통합제연성능)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.1-12
    • /
    • 2006
  • In this study, CFD computer simulations by FDS are carried out in order to confirm the performance of the combined operation of both sprinkler system and smoke curtain of 0.54 m depth installed for cooling and blocking the smoke which propagates beneath the sloped ceiling of a stairway corridor of which dimensions are 17.92 m long, 4.00 m wide, and 6.12 m high. It is shown that the response time of sprinklers decreases with fire size and it increases more about 1.1 second in case without smoke curtain than in case with smoke curtain, that the time of smoke transport from the fire source to the stairway outlet decreases considerably with fire size, and that the delay effect of smoke transport is not related to the sprinkler system, whether it is operated or not. This study shows that the combined operation of both sprinkler system and smoke curtain is very effective in smoke cooling, but it is a little for effect on smoke blockage. Although the hazard of skin burn due to radiative heat flux from hot smoke layer is decreased by spray cooling effect, the hazard of smoke suffocation and the weakening of visibility is increased by smoke downdrag and the turbulence of smoke-air mixing due to water spray. These conditions may result in preventing occupants from going out of the stairway during evacuation.

The Result and Attentiveness of Reconstructive Surgery by Anterolateral Thigh Perforator Free Flap (전외측 대퇴부 천공지 유리피판술의 실패 원인과 합병증)

  • Kang, Kyung-Dong;Lee, Jae-Woo;Kim, Kyoung-Hoon;Oh, Heung-Chan;Choi, Chi-Won;Choi, Soo-Jong;Bae, Yong-Chan;Nam, Su-Bong;Kim, Jung-Il;Chu, Gi-Seok
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: Anterolateral thigh (ALT) perforator free flap is commonly used because of its various benefits. The author reports important factors of preoperative and perioperative ALT perforator free flap and causes of failure. Methods: 84 patients who were treated with ALT perforator free flap from December 2004 to 2008, and February 2010 to April 2010 were studied. 61 patients were male and 23 were female. The mean age of patients was 51.1. The main cause was neoplasm and the main reconstructive areas were head and neck area. The size of flap was various from $3{\times}4$ to $12{\times}18$ cm. 6 patients received split thickness skin graft at donor site. Preoperative angiography was checked to all patients. Results: Among the 84 patients, partial necrosis of flaps occurred in 4 patients because of atherosclerosis, varicose vein, or inattention of patient, etc. And total flap necrosis in 5 patients because of abnormal vessels of recipient area or delay of operation, etc. One case of serous cyst was found as the complication of donor area. Two cases of skin graft on donor site were done because of suspected muscle compartment syndrome, 4 cases of that because of large flap. Septocutaneous perforators were found in 7 cases. The author couldn't find reliable perforator in 3 cases, ipsilateral anteromedial thigh perforator and contralateral ALT perforator and latissimus dorsi musculocutaneous free flap were done instead of ALT. There was no case which needed reoperation because of the impairment of blood supply, and 3 cases were revised by leech because of the burn injury by a lamp or venous congestion. Conclusion: Although ALT perforator free flap is widely used with its various merits, many factors such as preoperative condition of donor or recipient area, morphology of defect and operating time need to consider to prevent flap necrosis. And operators should need careful technique because septocutaneous perforator is uncommon, and musculocutaneous perforator is common but difficult to dissect.

Numerical Study of Evaporation and Ignition of in-line Array Liquid Droplets (액적 배열의 증발과 착화에 관한 수치해석적 연구)

  • 김충익;송기훈
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • The spreading fire of very small floating particles after they are ignited is fast and t therefore dangerous. The research on this area has been limited to experiments and global simulations which treat them as dusts or gaseous fuel with certain concentration well m mixed with air. This research attempted micro-scale analysis of ignition of those particles modeling them as liquid droplets. For the beginning, the in-line array of fuel droplets is modeled by two-dimensional, unsteady conservation equations for mass, momentum, energy and species transport in the gas phase and an unsteady energy equation in the liquid phase. They are solved numerically in a generalized non-orthogonal coordinate. The single step chemical reaction with reaction rate controlled by Arrhenius’ law is assumed to a assess chemical reaction numerically. The calculated results show the variation of temperature and the concentration profile with time during evaporation and ignition process. Surrounding oxygen starts to mix with evaporating fuel vapor from the droplet. When the ignition condition is met, the exothermic reactions of the premixed gas initiate a and burn intensely. The maximum temperature position gradually approaches the droplet surface and maximum temperature increases rapidly following the ignition. The fuel and oxygen concentration distributions have minimum points near the peak temperature position. Therefore the moment of ignition seems to have a premixed-flame aspect. After this very short transient period minimum points are observed in the oxygen and fuel d distributions and the diffusion flame is established. The distance between droplets is an important parameter. Starting from far-away apart, when the distance between droplets decreases, the ignition-delay time decreases meaning faster ignition. When they are close and after the ignition, the maximum temperature moves away from the center line of the in-line array. It means that the oxygen at the center line is consumed rapidly and further supply is blocked by the flame. The study helped the understanding of the ignition of d droplet array and opened the possibility of further research.

  • PDF