• 제목/요약/키워드: buried pipelines

검색결과 186건 처리시간 0.025초

철탑과 매설배관의 이격거리 관련 기준 (Standards of Separation Distance between Tower and Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.53-55
    • /
    • 2005
  • Because of the continuous growth of energy consumption and also the tendency to site power lines and pipelines along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. The lightning strokes collected by an electric substation or power line tower might cause arcing through the soil to an adjacent gas pipeline. This paper gives the review of the breakdown mechanism and the standards of separation distance between lower and pipelines.

  • PDF

Application of Ground Penetrating Radar (GPR) coupled with Convolutional Neural Network (CNN) for characterizing underground conditions

  • Dae-Hong Min;Hyung-Koo Yoon
    • Geomechanics and Engineering
    • /
    • 제37권5호
    • /
    • pp.467-474
    • /
    • 2024
  • Monitoring and managing the condition of underground utilities is crucial for ground stability. This study aims to determine whether images obtained using ground penetrating radar (GPR) accurately reflect the characteristics of buried pipelines through image analysis. The investigation focuses on pipelines made from different materials, namely concrete and steel, with concrete pipes tested under various diameters to assess detectability under differing conditions. A total of 400 images are acquired at locations with pipelines, and for comparison, an additional 100 data points are collected from areas without pipelines. The study employs GPR at frequencies of 200 MHz and 600 MHz, and image analysis is performed using machine learning-based convolutional neural network (CNN) techniques. The analysis results demonstrate high classification reliability based on the training data, especially in distinguishing between pipes of the same material but of different diameters. The findings suggest that the integration of GPR and CNN algorithms can offer satisfactory performance in exploring the ground's interior characteristics.

발파진동에 의한 매설가스관의 진동 해석 (Vibration Analysis of Buried Gas Pipeline by Blast Vibration)

  • 정석영;박춘수;홍성경;김준호;고재필
    • 한국가스학회지
    • /
    • 제6권1호
    • /
    • pp.46-51
    • /
    • 2002
  • 지하철 공사나 도로 공사에서는 다양한 건설장비의 사용으로 인해 발생되는 진동이 가스관에 직$\cdot$간접적으로 영향을 미치고 있다. 특히, 매설가스관은 매설된 위치와 근접한 곳에서 시행되는 발파로 인한 진동영향이 큰 상태이다. 매설가스관 근처의 발파작업시 발생되는 진동에 대한 응답을 해석하기 위해서 등가선형해석법을 적용하여 지반의 비선형거동을 구현하였다. 해석 결과, 매설가스관에서의 가속도 응답치는 실측치와 근사한 결과를 보였고, Peak치 발생시간도 실측치와 거의 일치하였다. 그러므로 매설가스관의 동적해석을 할 때 일반적인 지진해석 메카니즘의 적용이 가능함을 알 수 있었다.

  • PDF

Strain demand prediction method for buried X80 steel pipelines crossing oblique-reverse faults

  • Liu, Xiaoben;Zhang, Hong;Gu, Xiaoting;Chen, Yanfei;Xia, Mengying;Wu, Kai
    • Earthquakes and Structures
    • /
    • 제12권3호
    • /
    • pp.321-332
    • /
    • 2017
  • The reverse fault is a dangerous geological hazard faced by buried steel pipelines. Permanent ground deformation along the fault trace will induce large compressive strain leading to buckling failure of the pipe. A hybrid pipe-shell element based numerical model programed by INP code supported by ABAQUS solver was proposed in this study to explore the strain performance of buried X80 steel pipeline under reverse fault displacement. Accuracy of the numerical model was validated by previous full scale experimental results. Based on this model, parametric analysis was conducted to study the effects of four main kinds of parameters, e.g., pipe parameters, fault parameters, load parameter and soil property parameters, on the strain demand. Based on 2340 peak strain results of various combinations of design parameters, a semi-empirical model for strain demand prediction of X80 pipeline at reverse fault crossings was proposed. In general, reverse faults encountered by pipelines are involved in 3D oblique reverse faults, which can be considered as a combination of reverse fault and strike-slip fault. So a compressive strain demand estimation procedure for X80 pipeline crossing oblique-reverse faults was proposed by combining the presented semi-empirical model and the previous one for compression strike-slip fault (Liu 2016). Accuracy and efficiency of this proposed method was validated by fifteen design cases faced by the Second West to East Gas pipeline. The proposed method can be directly applied to the strain based design of X80 steel pipeline crossing oblique-reverse faults, with much higher efficiency than common numerical models.

콘크리트 매설관의 동적응답해석에 대한 곡선적합식의 개발 (Development of Curve Fitted Equation about Dynamic Response Analysis of a Buried Concrete Pipelines)

  • 정진호;김성반;안명석
    • 화약ㆍ발파
    • /
    • 제24권1호
    • /
    • pp.9-19
    • /
    • 2006
  • 본 연구는 일단고정-일단자유 단부 경계조건을 가진 콘크리트 매설관의 동적응답을 연구하고, 내진성능 평가 시 실용적이고 실무적용성이 높은 곡선 적합식의 개발을 목적으로 한다. 매설관의 동적응답을 연구하기 위해 기존 연구에서 개발된 수치해석 프로그램을 사용하여 일단고정-일단자유 단부 경계조건에 대한 최대변형 률 발생지점을 산정한 후, 산정된 지점에 대하여 5-1000(m) 의 파장${\lambda}$과 100-2000(m/see)의 전파속도 $(V_s)$를 적용하여 파장${\lambda}$의 변화와 전파속도 $(V_s)$의 변화에 따른 단위 (휨) 변형률 곡선식을 산출하였다. 적합성이 높은 곡선 적합식을 개발하기 위해 비선형 최소자승법을 이용하여 다양한 형태의 지수방정식을 검정한 후, 가장 좋은 결과를 나타내는 곡선 적합식과 필요한 계수 값을 제시하였다.

Numerical modeling of uplift resistance of buried pipelines in sand, reinforced with geogrid and innovative grid-anchor system

  • Mahdi, Majid;Katebi, Hooshang
    • Geomechanics and Engineering
    • /
    • 제9권6호
    • /
    • pp.757-774
    • /
    • 2015
  • Reinforcing soils with the geosynthetics have been shown to be an effective method for improving the uplift capacity of granular soils. The pull-out resistance of the reinforcing elements is one of the most notable factors in increasing the uplift capacity. In this paper, a new reinforcing element including the elements (anchors) attached to the ordinary geogrid for increasing the pull-out resistance of the reinforcement, is used. Thus, the reinforcement consists of the geogrid and anchors with the cylindrical plastic elements attached to it, namely grid-anchors. A three-dimensional numerical study, employing the commercial finite difference software FLAC-3D, was performed to investigate the uplift capacity of the pipelines buried in sand reinforced with this system. The models were used to investigate the effect of the pipe diameter, burial depth, soil density, number of the reinforcement layers, width of the reinforcement layer, and the stiffness of geogrid and anchors on the uplift resistance of the sandy soils. The outcomes reveal that, due to a developed longer failure surface, inclusion of grid-anchor system in a soil deposit outstandingly increases the uplift capacity. Compared to the multilayer reinforcement, the single layer reinforcement was more effective in enhancing the uplift capacity. Moreover, the efficiency of the reinforcement layer inclusion for uplift resistance in loose sand is higher than dense sand. Besides, the efficiency of reinforcement layer inclusion for uplift resistance in lower embedment ratios is higher. In addition, by increasing the pipe diameter, the efficiency of the reinforcement layer inclusion will be lower. Results demonstrate that, for the pipes with an outer diameter of 50 mm, the grid-anchor system of reinforcing can increase the uplift capacity 2.18 times greater than that for an ordinary geogrid and 3.20 times greater than that for non-reinforced sand.

3차원 시간이력해석을 통한 매설가스배관 종방향 지진응답 예측을 위한 경험적 설계법의 적용성 평가 (Estimation of Applicability of Empirical Design Procedure for Predicting Seismic Response of Buried Gas Pipelines through 3D Time-history Analysis)

  • 곽형주;박두희;이장근;강재모
    • 한국지반공학회논문집
    • /
    • 제31권9호
    • /
    • pp.53-68
    • /
    • 2015
  • 매설가스배관의 내진설계에서 종방향 변형률은 중요한 평가 요소이다. 일반적으로 지진파를 조화파로 단순화하며 이의 파장은 토층의 주기와 전단파 속도의 곱으로 계산하여 매설관의 응답을 계산하는 경험적 설계방법이 널리 사용되지만 이의 정확성이 평가된 사례가 없다. 본 연구에서는 1차원 지반응답해석을 수행하여 매설심도에서의 변위-시간 이력을 추출하였으며, 이를 적용한 시간이력해석을 수행하여 매설관의 응답을 평가하였다. 매설관과 지반의 상호작용은 3차원 쉘-스프링 모델을 사용하여 모사하였다. 시간이력해석으로 계산된 결과는 설계방법과 비교하여 이의 정확성을 평가하였다. 비교 결과, 파장을 예측하기 위해서는 지반응답해석을 수행해야 하는 것으로 나타났다. 토층의 고유주기는 가속도의 탁월주기를 예측하는 데에는 활용될 수 있으나 변위의 탁월주기를 예측할 수 없는 것으로 나타났다. 반면, 파장에 대한 정확한 정보가 제공될 경우, 조화파에 대하여 제시된 해석해는 정확도가 높으며 설계에 적용 가능한 것으로 나타났다. 본 연구 대상이 동시베리아 지역에 적용될 매설가스관이라 동시베리아 지역의 대표 주상도를 해석 에 사용하였지만 본 연구의 결론은 기타 모든 지역에 적용 가능하며 가스관뿐만 아니라 상수도관 등 다양한 매설관에 적용 가능하다.

지반의 수분 상태에 따른 매립 배관에서의 유도초음파 모드 감쇠 변화 (Effect of Moisture Conditions in Soils on Mode Attenuation of Guided Waves in Buried Pipes)

  • 이주원;신성우;나원배;김영상
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.42-47
    • /
    • 2010
  • Recently, many techniques have been developed for the inspection of pipelines using guided waves. However, few researches have been made on the application of those techniques for buried underground pipes. Guided wave motions in the buried pipes are somewhat different from those of on-ground pipes which have traction-free (air) boundary condition on outer pipe walls and thus are strongly affected by the mechanical property of the surrounding soils. Therefore, it should be investigated the effect of soil properties on the guided wave behavior in buried pipe. On the other hand, the mechanical property of soil is largely depending on its moisture conditions nevertheless of other influential factors such as void ratio. In this study, the effect of moisture conditions in soils on mode attenuation of guided waves in the buried pipe is investigated. To this end, numerical study is performed to characterize mode attenuation behavior in buried pipes and the effective mode which is suitable for long range inspection is identified.

주파수 대역 변화를 이용한 배관의 누수지점 추정 개선 연구 (Improved Estimation of Leak Location of Pipelines Using Frequency Band Variation)

  • 이영섭;윤동진
    • 비파괴검사학회지
    • /
    • 제34권1호
    • /
    • pp.44-52
    • /
    • 2014
  • 스마트워터그리드 시스템의 지하 상수도 배관 관리에 있어서 누수는 중요한 요소인데, 특히 그 배관이 낡았고 인구가 많은 도시의 포장도로나 다양한 건축물의 아래에 매설된 경우이다. 이러한 누수지점의 정확한 탐지는 이들 배관의 효율적인 운용을 위해 필수적이기 때문에, 주파수 대역 변화, 창 필터 그리고 확률에 바탕한 새로운 누수지점 탐지 방법론을 본 논문을 통해 제안한다. 정확한 누수지점의 추정은 누수음에 의한 센서 신호간의 시간 지연 추정의 정확성에 따라 결정된다는 것이 알려져 있기 때문에 중요한 주파수에 가중치를 부여하는 몇 가지의 창 함수들이 개선된 상호상관함수를 계산하기 위해 적용되었다. 실제 주철로 제작된 길이 253.9 m의 지하매설 상수도 배관에 대해 새로운 방법론을 적용한 실험결과는 향상된 누수지점 탐지 성능을 보여 주었다.

국내 및 미국 시방서에 따라 시공된 지중매설관의 동적거동 (Dynamic Behavior of Buried Pipelines Constructed by Domestic and USA Specifications)

  • 전상수;김재민
    • 한국방재학회 논문집
    • /
    • 제11권1호
    • /
    • pp.59-66
    • /
    • 2011
  • 지진재해로 인한 라이프라인의 피해는 구조물의 손상뿐만 아니라, 통신장애, 전력 가스 수자원 등 다양한 생활에너지의 공급에 장애를 발생시킨다. 이러한 지진재해에 효율적으로 대응하기 위해 미국과 일본에서는 HAZUS 및 HERAS와 같은 지진재해평가 시스템을 구축하여 활용하고 있다. 국내에서도 이러한 시스템 구축을 위해 노력하고 있으나, 근본적으로 구조물의 지진 해석을 통한 평가자료가 부족한 실정이다. 이에 본 연구에서는 다양한 구조물 중 국내에 시공된 수많은 매설관을 조사하여 관 재질 특성에 따라 연성관과 취성관으로 분류하고 이에 대한 동적 거동을 분석하였다. 다양한 지진하중 하에서 국내 및 미국의 시공기준에 따라 매설관의 동적 거동을 비교 평가하였다. 본 연구를 통하여 미국 HAZUS 프로그램의 알고리즘에 따른 국내의 매설관 손상평가의 적정성을 조사하였다.