• 제목/요약/키워드: bulk decay

검색결과 56건 처리시간 0.029초

EPANET 2.0과 관망실험을 통한 배수관망 염소농도 감쇄 비교연구 (A comparative study for the decay of chlorine residual using EPANET2.0 and an experimental pipeline system)

  • 백다원;김현준;김상현
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.411-419
    • /
    • 2018
  • The residual chlorine concentration is an essential factor to secure reliable water quality in the water distribution systems. The chlorine concentration decays along the pipeline system and the main processes of the reaction can be divided into the bulk decay and the wall decay mechanisms. Using EPANET 2.0, it is possible to predict the chlorine decay through bulk decay and wall decay based on the pipeline geometry and the hydraulic analysis of the water distribution system. In this study, we tried to verify the predictability of EPANET 2.0 using data collected from experimental practices. We performed chlorine concentration measurement according to various Reynolds numbers in a pilot-scale water distribution system. The chlorine concentration was predicted using both bulk decay model and wall decay model. As a result of the comparison between experimental data and simulated data, the performance of the limited $1^{st}$-order model was found to the best in the bulk decay model. The wall decay model simulated the initial decay well, but the overall chlorine decay cannot be properly predicted. Simulation also indicated that as the Reynolds number increased, the impact of the wall.

상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발 (Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network)

  • 정보배;김기범;서지원;구자용
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

배급수계통에서 잔류염소 감소 특성 및 적용연구 (Modeling and Application of Chlorine Bulk Decay in Drinking Water Distribution System)

  • 안재찬;박창민;구자용
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.487-496
    • /
    • 2005
  • Chlorine bulk decay tests were carried out by bottle test under controlled conditions in a laboratory. Experiments were performed at different temperatures: $5^{\circ}C$, $15^{\circ}C$, $25^{\circ}C$, and the water temperatures when samples were taken from the effluent just before entering to its distribution system. 38 bulk tests were performed for water of Al (water treatment plant), 4 bulk tests for A2 (large service reservoir), and A3(pumping station). Residual chlorine concentrations in the amber bottles were measured over time till about 100 hours and bulk decay coefficients were evaluated by assuming first-order, parallel first-order, second-order. and $n^{th}-order$ reaction. The $n^{th}-order$ coefficients were obtained using Fourth-order Runge-Kutta Method. A good-fit by the average coefficient of determination ($R^2$) was first-order ($R^2=0.90$) < parallel first-order ($R^2{_{fast}}=0.92$, $R^2{_{slow}}=0.95$) < second-order ($R^2=0.95$) < $n^{th}-order$ ($R^2=0.99$). But if fast reaction of parallel first-order bulk decay were applied to the effluent of large service reservoir with ca. 20 hours of travel time and slow reaction in the water distribution system following the first 20 hours, parallel first-order bulk decay would be best and easy for application of water quality modeling technique.

전자빔 조사 폴리머의 전자 분포의 축퇴 과정 (Decay Process of Charge Distribution in E-beam Irradiated Polymers)

  • 최용성;김형곤;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.69-72
    • /
    • 2008
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

E-빔 조사된 폴리머의 전하 분포의 축퇴 과정 (Decay Process of Charge Distribution in E-Beam Irradiated Polymers)

  • 윤주호;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.329-330
    • /
    • 2007
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

시간 경과에 따른 YBCO 초전도 복합체의 포획 자기장 감쇄 (The Trapped Field Decay of YBCO Superconductor Composite with Times)

  • 이만수;장건익;전병혁;하동우;손명환;한영희;박병준
    • Progress in Superconductivity
    • /
    • 제12권2호
    • /
    • pp.82-87
    • /
    • 2011
  • We studied the trapped field properties of bulk Y-Ba-Cu-O superconductors by applying 3 T of the permanent or $Nb_3Ti$ superconducting magnet. The 28 mm circular type of YBCO bulk superconductor was prepared and then hole at the center of bulk, parallel to the c-axis, was mechanically drilled. Typical size of hole in YBCO bulk was 10 mm in diameter. In order to examine the trapped field variation in terms of different impregnated materials, a hole in YBCO bulk was filled with resin and indium respectively. The trapped field decay due to flux flow was determined in terms of time. Our preliminary result indicates the trapped field value measured on the YBCO without hole after 30 minute by applying 3 T, was 6,500 G, which is much higher than that, 4,500 G, measured on YBCO with hole. Also, we confirmed that the tendency of a trapped field decrement with time was almost the same regardless of the impregnated materials in YBCO.

온도 상승시에 전자빔 조사된 폴리머내의 전하 분포의 축퇴 현상 연구 동향 (A Research Trend on Space Charge Analysis in Polymer Irradiated by Electron Beam)

  • 고성민;김남용;김대열;최용성;문종대;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1992-1993
    • /
    • 2007
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

하수재이용수의 유리잔류염소 수체감소 특성 연구 (Characteristics of Residual Free Chlorine Decay in Reclaimed Water)

  • 강성원;이재영;이현동;박재현;곽필재;오현제
    • 대한환경공학회지
    • /
    • 제35권4호
    • /
    • pp.276-282
    • /
    • 2013
  • 하수재이용수는 부족한 수자원 문제를 해결할 수 있는 대표적인 대안으로 주목받고 있다. 본 연구에서는 하수재이용수의 공급시 유리잔류염소의 수체감소 특성을 온도별(5, 15, $25^{\circ}C$), 초기 주입농도별(1, 2, 4, 6 mg/L)로 살펴보았고 그 결과를 이용하여 최적 염소주입량을 산정하는 방법에 대하여 연구하였다. 하수재이용수는 정수와 비교하여 염소주입시 반응속도가 초기에 매우 빠르게 나타나 기존의 general first-order decay model ($C_t=C_o(e^{-k_bt})$)을 사용하기에 부적합하여 exponential firstorder decay model ($C_t=a+b(e^{-k_bt})$)을 적용한 결과 유리잔류염소의 감소를 더욱 정확하게 예측할 수 있었다($r^2$=0.872~0.988). 수체감소계수를 산출한 결과 초기주입량 1 mg/L, $25^{\circ}C$의 조건에서 653 $day^{-1}$로 가장 크게 나타났고, $5^{\circ}C$, 초기주입량 6 mg/L의 조건에서 3.42 $day^{-1}$로 가장 낮았다. 수체감소계수는 온도가 증가함에 따라 수체감소계수는 증가하는 경향을 나타내었고, 초기 주입농도가 증가함에 따라 수체감소계수는 감소하는 경향을 나타내었다. 적정 초기 염소요구량을 산정하기 위해서 전체 반응기간을 0~30분, 30~5,040분으로 구분한 후, 30~5,040분의 실험결과를 사용한 예측식을 사용함으로써 더욱 정확한 염소주입량 산정을 할 수 있었다. 또한, 온도별로 최적 염소주입량을 산정한 결과 염소주입 후 4시간이 경과한 시점에서 유리잔류염소 0.2 mg/L를 유지하기 위해서는 온도(x)별 초기 염소요구량(y)의 관계를 y = 1.409 + 0.450x와 같이 얻을 수 있었다.

레이저 형광여기법(LIF)를 이용한 복잡 난류유동장의 혼합특성에 관한 연구 (A Study on the Mixing Characteristics in Complex Turbulent Flow by a Laser Induced Fluorescence Method)

  • 김경천;정은호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.542-547
    • /
    • 2001
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera can be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration in each region after the dye infusion reflects the large scale mixing while the followed slow decay reveals the small scale mixing. The temporal change of concentration probability functions conjectures the two sequential processes in the batch type mixing. An inactive column of water existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

  • PDF

레이저 형광여기법(LIF)를 이용한 러쉬톤 터빈 교반기의 혼합특성에 관한 연구 (A Study on the Mixing Characteristics in a Rushton Turbine Reactor by a Laser Induced Fluorescence Method)

  • 정은호;김경천
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1145-1152
    • /
    • 2002
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields was obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera could be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter. height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration after the dye infusion reflects the large scale turbulent mixing while the fellowed slow decay reveals the small scale molecular mixing. The temporal change of concentration variance field conjectures the two sequential processes for the batch type mixing. An inactive column of water is existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.