• 제목/요약/키워드: building surface design

검색결과 356건 처리시간 0.027초

가공 제품 품질 향상을 위한 면취장비의 설계 개선 (Design Alterations of a Chamfering Machine Structure for the Improved Surface Quality)

  • 이일환;노승훈;한대성;김영조;길사근;박인규
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.117-122
    • /
    • 2019
  • Pipes are widely used in various industries such as automobile, anti-vibration devices, factories and ship building. Chamfering is one of the most critical processes in pipe manufacturing which removes burrs of the pipes for better surface quality. In most cases, the defects of the chamfered surface are originated from the structural vibrations of the chamfering machine. In this study, the dynamic characteristics of a chamfering machine have been analyzed though the experiment and the computer simulation. And the effects of the design parameters affecting the stability of the machine have been investigated to stabilize the machine structure and further to reduce structural vibrations. The result shows that design alterations to stabilize the machine can suppress the defects of the machined surface as well as the vibrations during chamfering.

초기 설계단계에서 개산 견적의 수량산출에 의한 건축공사비 작성에 대한 고찰 - 공사비 관리 사례 및 작업 방법을 중심으로 - (Consideration on the Creation of Construction Cost by Calculating the Quantity at the Planning Design Stage - Focusing on Construction Cost Management Vases and Work Methods -)

  • 현동명;전상훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.329-330
    • /
    • 2021
  • The calculation of the correct construction value in the construction should be investigated after the quantity is calculated. In order to calculate the quantity requires a lot of cost and time, and the initial accurate quantity calculation is not possible. Therefore, in the planning step in order to successfully complete the project to demonstrate the practicality of the difference between the construction cost by the construction design by presenting a method for calculate the quantity through the estimate with the construction open, floor plan, surface view, section.

  • PDF

지표수 열교환기의 용량과 적용 효과에 대한 설계 인자의 영향 (Impact of Design Parameters on Length and Application Effect of Surface Water Heat Exchanger(SWHE))

  • 손병후;민경천
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.49-56
    • /
    • 2016
  • 본 연구에서는 설계 인자가 지표수 열교환기 길이에 미치는 영향을 분석하였다. 또한 수직 밀폐형 지중열교환기와 지표수 열교환기를 같이 이용한다고 가정한 후, 지중 순환수의 온도 변화를 분석하였다. 지표수 열교환기 출구 온도와 연못 온도의 차이를 크게 하면, 열교환기 파이프 길이는 줄어들었다. 아울러 연못 온도가 높을수록 파이프 길이는 감소하지만, 파이프 바깥지름의 영향은 상대적으로 적었다. 또한 파이프 두께가 얇을수록 전도 열전달에서 열저항의 영향이 감소하기 때문에 파이프 길이는 감소하였다. 수직 밀폐형 시스템에 지표수 열교환기를 추가 적용하면, 지중열교환기 순환수 온도는 시간이 지날수록 감소하였다.

이용자의 도시적 공간체험을 유도하는 도서관 공간 특성 연구 (A Study on the Characteristics of the Library Space for Introducing Urban Experiences)

  • 문은미
    • 한국실내디자인학회논문집
    • /
    • 제23권4호
    • /
    • pp.240-247
    • /
    • 2014
  • This study is aimed to examine the characteristics of library space, in which user experiences and social networking are central in its design. Today, a library is a place to provide diverse accesses and experiences to information networks, where various individuals and user groups come and share mutual understanding and experiences. Library users developed social ties and a sense of community through library experiences. As a multipurpose space of a community, a library has the characteristics of urban public space like sidewalks and plazas. The eight case studies of libraries are analyzed from the viewpoint of each factor of library experience, including landscape, sidewalk, and plaza experience. The study drew its conclusions as follows. First, a library is a regional landmark for the users. Thus, it tends to be designed to allow transparency on its surface which introduces inner and outer landscape into the inside of the building. Second, the users experience a library similarly as they experience an urban street where they interface, browse, and interact with people and information. As they interact and share experiences, they develop solidarity and social ties among them. A library is designed to preserve continuity to adjacent streets, which increases accessibility to the building and hosts street activities into the building. Third, a library today is designed to be a flexible open space with information networking as well as community networking which allows library users diverse activities within it. For example, a multipurpose grand stairs in the middle of the main circulation of a building allows the users diverse activities. A large open stack with reading areas gives the users the feeling of an urban plaza where they can move vertically and horizontally. In conclusion, all findings of this study imply a user-oriented design for a library building.

열전모듈 제습기의 에너지 효율과 성능에 미치는 설계 인자의 영향 분석 (The Analysis of the Effects of Design Parameters on the Energy Efficiency and Performance of TEM Dehumidifiers)

  • 이태희
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.1-7
    • /
    • 2020
  • To provide a design direction for high efficiency thermoelectric module(TEM) dehumidifiers, the effects of design factors of TEM dehumidifiers on dehumidification energy efficiency and performance were numerically investigated. The design factors considered in this study are the TEM capacity, the performance of heat exchangers on the heating and cooling surfaces of the TEM. The higher capacity of the TEM results the higher dehumidification energy efficiency and performance at some operating voltage. The enhanced performance of the heat exchanger on heating surface increased the dehumidification energy efficiency and performance at all the operating voltage. The enhanced performance of the heat exchanger on cooling surface decreased the dehumidification energy efficiency and performance at all operating voltage.

공간디자인에서 디지털 표피 재 조직화, 물리적 구현 방법 연구 - 표피 재 조직화, 가공 중심으로 - (A Study on methodology of physical Fabrication & reorganization of Epidermis in Space Design - Focused on reorganization of Epidermis, Fabrication -)

  • 박정주
    • 한국실내디자인학회논문집
    • /
    • 제17권2호
    • /
    • pp.150-161
    • /
    • 2008
  • It requires more close cooperation process and mediator for smooth communication in this industry structure where design and engineers are separated. The database of design integrates separate system and helps connection between organizations. The application category is utilized variously from formation to operation. Architectures addressed in this content as Frank Gehry and Nox are making differentiated design on the base of 3d digital methodology and using it widely from generation to fabrication. Especially they got to be free from the generative limit as it became available to analyse, digital surface organization, and realize the complex system form. Now more integrated and delicate works got to be affordable owing to various kinds of improved CNC, RP(rapid-prototype) machines, and architecture hardwares. With a linkage of software now at their disposal, architects can create a digital model of a building and all of its design elements, and in turn use this 3d information to construct actual building components using machines driven by CNC and other advanced manufacturing techniques. Digital technologies are enabling a direct correlation between what design and construction, thus bringing to the forefront the issue of the significance of information, the production, communication, application, and control of digital information in the industrial system. The central requirement is the clear, reliable, and consistent exchange of information among all parties involved in creating a given project.

건물통합형 PV Solar Roof의 통풍효과 실험분석 (Experimental Analysis of Ventilation Effect on the Performance of Building-Integrated PV Solar Roof)

  • 김진희;이강록;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.73-79
    • /
    • 2006
  • The integration of PV modules into building facades or roof could raise PV module temperature that results in the reduction of electrical power generation. Lowering operating temperature of PV module is important in this respect, and PV module temperature should be considered more accurately, for building-integrated PV(BIPV) systems in predicting their performance. This paper describes a BIPV solar roof design and verifies its performance through experiment In relation to the effect of ventilation in space between PV module and roof surface. The results showed that the ventilation in the space had a positive effect in lowering the module temperature of the BIPV solar roof that enhanced the performance of its electricity generation.

Moisture Absorption and Desorption Properties of Douglas Fir, Hinoki, Larch, Plywood, and WML Board in Response to Humidity Variation

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권4호
    • /
    • pp.488-502
    • /
    • 2020
  • In this study, the moisture absorption and desorption properties presented by the Health-Friendly Housing Construction Standards of South Korea were compared using the wood of three tree species (Douglas-fir, Hinoki, Larch) and two types of wood-based materials(Plywood, WML Board). The national standards for functional building materials present that the amounts of moisture absorption and desorption should be at least 65g/㎡ on average, respectively according to the test method under KS F 2611:2009. Therefore, in this study, the moisture absorption/desorption properties of materials with no treatment (Control), with punching, and with surface stain finishing and the moisture absorption/desorption property improvement effects of the treatments were compared and analyzed. According to the results of this study, it was evaluated that all five types of wood and wood-based materials tested did not satisfy the amount of moisture absorption/desorption of at least 65g/㎡, which is the performance standard for moisture absorption/desorption functional building materials, indicating that untreated wood and wood-based materials cannot be applied as functional finishing materials according to the Health-Friendly Housing Construction Standards. The surface stain finishing greatly reduced the moisture absorption and desorption rates of the materials, and the amounts of moisture absorbed and desorbed were also shown to decrease by at least two times on average. When the surfaces of the materials were punched with Ø4mm holes at intervals of 20 mm, the moisture absorption/desorption areas increased from 18% to 51%, and this increase was shown to be capable of increasing the amounts of moisture absorbed/desorbed by 29% on average at the minimum, and 81% on average at the maximum. The effects of punching were shown to be identical even in cases where the materials were stain finished. For the application of wood or wood-based materials as eco-friendly, health-friendly, and moisture absorption/desorption functional building materials hereafter, it is judged that new physical and chemical improvement studies should be conducted, and treatment methods should be developed.

Multiple wall dampers for multi-mode vibration control of building structures under earthquake excitation

  • Rahman, Mohammad Sabbir;Chang, Seongkyu;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • 제63권4호
    • /
    • pp.537-549
    • /
    • 2017
  • One of the main concerns of civil engineering researchers is developing or modifying an energy dissipation system that can effectively control structural vibrations, and keep the structural response within tolerable limits during unpredictable events like earthquakes, wind and any kind of thrust load. This article proposes a new type of mass damper system for controlling wideband earthquake vibrations, called Multiple Wall Dampers (MWD). The basic principle of the Tuned Mass Damper (TMD) was used to design the proposed wall damper system. This passive energy dissipation system does not require additional mass for the damping system because the boundary wall mass of the building was used as a damper mass. The multi-mode approach was applied to determine the location and design parameters of the dampers. The dampers were installed based on the maximum amplitude of modes. To optimize the damper parameters, the multi-objective optimization Response Surface Methodology was used, with frequency response and maximum displacement as the objective functions. The obtained structural responses under different earthquake forces demonstrated that the MWD is one of the most capable tools for reducing the responses of multi-storied buildings, and this system can be practically used for new and existing building structures.

사무소 건물에서 광선반의 채광성능 분석 (An Analysis of Daylighting Performance of Light Shelf in Office Building)

  • 박병일;양인호;나미현
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.1-11
    • /
    • 2008
  • 본 논문의 목적은 광선반을 사무소건물에 효율적으로 적용할 수 있는 기준자료를 제시하는 것이다. 광선반의 채광성능 시뮬레이션을 위해 3Ds Studio Max 프로그램이 사용되었으며, 광선반의 폭, 표면반사율, 설치각도와 같은 주요 변수의 최적값을 도출하였다. 다음으로 이러한 최적값을 이용하여 광선반의 채광성능을 분석하였다. 시뮬레이션 결과 사무소건물에서 광선반을 설치함으로써 주광성능을 향상시킬 수 있는 것으로 나타났다.