• Title/Summary/Keyword: building surface

Search Result 1,844, Processing Time 0.027 seconds

Analysis the case study of tower type apartment by opening types of building surface (탑상형 아파트의 외피개방유형에 따른 전기에너지 사용량 사례 분석)

  • Kim, Yu-Won;Lee, Hyun-Soo;Kim, Eun-Hye
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.111-115
    • /
    • 2011
  • The purpose of this study was the analysis of electric energy consumption with the case study of tower type apartment's opening of building surface. We analyze the relationship between tower type apartment's opening of building surface and using electric energy consumption. The results of this study are: 1) The highest energy consumption of electric energy was on August without any influence of opening types of building surface. 2) Also, the south-west sides consumption of August was 848 kWh on Type B(one side opening) and it was the highest usage. 3) A house if facing west used more electricity than facing east when its opening of building surface's datum level is facing south. However, the house of facing east used more power than west when its opening of building surface's datum level is facing north. 4) When opening of building surface is facing on north-west or north-east, the opening of building surface's side of west and east used more electric power than north-west or north-east sides.

  • PDF

Paneling of Curved NURBS Surface through Marching Geodesic - Application on Compound Surface - (일방향 지오데식을 활용한 곡면 형상의 패널링 - 복합 곡면을 중심으로 -)

  • Hong, Ji-Hak;Sung, Woo-Jae
    • Journal of KIBIM
    • /
    • v.11 no.4
    • /
    • pp.42-52
    • /
    • 2021
  • Paneling building facades is one of the essential procedures in building construction. Traditionally, it has been an easy task of simply projecting paneling patterns drawn in drawing boards onto 3d building facades. However, as many organic or curved building shapes are designed and constructed in modern architectural practices, the traditional one-to-one projection is becoming obsolete for the building types of the kind. That is primarily because of the geometrical discrepancies between 2d drawing boards and 3d curved building surfaces. In addition, curved compound surfaces are often utilized to accommodate the complicated spatial programs, building codes, and zoning regulations or to achieve harmonious geometrical relationships with neighboring buildings in highly developed urban contexts. The use of the compound surface apparently makes the traditional paneling pattern projection more challenging. Various mapping technics have been introduced to deal with the inabilities of the projection methods for curved facades. The mapping methods translate geometries on a 2d surface into a 3d building façade at the same topological locations rather than relying on Euclidean or Affine projection. However, due to the intrinsic differences of the planar 2d and curved 3d surfaces, the mapping often comes with noticeable distortions of the paneling patterns. Thus, this paper proposes a practical method of drawing paneling patterns directly on a curved compound surface utilizing Geodesic, which is faithful to any curved surface, to minimize unnecessary distortions.

Influence of Moisture on Mold Growth in Building Materials (건축자재 내의 수분이 곰팡이 성장에 미치는 영향)

  • Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.12
    • /
    • pp.852-857
    • /
    • 2012
  • Recently, the indoor air pollution by microbes such as fungi and mites have become a concern as important research topic on indoor air quality. Fungal growth is significantly affected by humidity. In this study, we examined the influence of relative humidity on the surface of building materials and the water content of building materials on the fungal growth rate by measuring the mycelium length of fungi in the fungal detector placed on the surface of building materials. As a result, even if the relative humidity on the surface of building materials is identical, the more water content of building materials is, the more fungi grow faster. It was suggested that fungal growth rate depends on not only the relative humidity on the surface of building materials but also the water content of building materials.

A Study on the Analysis of Energy Consumption Patterns According to the Building Shapes with the Same Volume (동일 체적의 건물 형상에 따른 에너지 소비량 패턴에 대한 분석 연구)

  • Choi, Won-Ki;Kim, Heon-Joong;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.103-109
    • /
    • 2007
  • This study was focused on the establishment of a fundamental DB(database) that is available in the building design process, so we performed the simulation analysis about the energy consumption on the various same volume buildings. Because energy consumption in building is affected by the exterior surface area, the ratio of long/short length in surface and the adjacent internal surface area etc.. For these purpose, we assumed the unit module and made a constructable 16 model buildings which are composed of the 16 unit modules. Then we analyzed the simulation using the TRNSYS 16 and the Seoul weather data. In results, energy consumption in building is more reduced that in case of the smaller exterior surface area, the lower stories building and the larger adjacent surface area etc.. Further study is to be required the sensitivity analysis on the various weather conditions, building shapes and window area etc..

AUTOMATIC IDENTIFICATION OF ROOF TYPES AND ROOF MODELING USING LIDAR

  • Kim, Heung-Sik;Chang, Hwi-Jeong;Cho, Woo-Sug
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.83-86
    • /
    • 2005
  • This paper presents a method for point-based 3D building reconstruction using LiDAR data and digital map. The proposed method consists of three processes: extraction of building roof points, identification of roof types, and 3D building reconstruction. After extracting points inside the polygon of building, the ground surface, wall and tree points among the extracted points are removed through the filtering process. The filtered points are then fitted into the flat plane using ODR(Orthogonal Distance Regression). If the fitting error is within the predefined threshold, the surface is classified as a flat roof. Otherwise, the surface is fitted and classified into a gable or arch roof through RMSE analysis. Based on the roof types identified in automated fashion, the 3D building reconstruction is performed. Experimental results showed that the proposed method classified successfully three different types of roof and that the fusion of LiDAR data and digital map could be a feasible method of modelling 3D building reconstruction.

  • PDF

Surface displacements due to tunneling in granular soils in presence and absence of geosynthetic layer under footings

  • Rebello, Nalini E.;Shivashankar, R.;Sastry, Vedala R.
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.739-744
    • /
    • 2018
  • This paper presents the results of numerical modeling studies on the effect of displacements of tunneling in granular soils. Presence of building loads is considered, to find displacement generated at the surface on tunnel. Effect of varying eccentricities of building is simulated, to find influence of building on vertical and horizontal displacement. Studies were carried out in two cases of with and without a geosynthetic layer installed at the bottom of the footing. Results of analysis revealed, the presence of geosynthetic layer under footing, with building placed on centre line, reduced the surface displacements compared to displacement generated without geosynthetic layer. Presence of geosynthetic layer under footing had a dominant effect in reducing displacements in high storey structures. However, when the building was shifted to greater eccentricities from centre line, presence of geosynthetic layer, led to insignificant reduction of displacements on the centre line at the surface.

Numerical study of wind load on the high-rise building (고층건물에 작용하는 풍하중에 관한 수치 해석적 연구)

  • Song, C.S.;Park, S.O.;Kim, D.W.;Ha, Y.C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.205-208
    • /
    • 2008
  • The wind load on building surface is numerically investigated. The geometry of target building is a square cross section and aspect ratio (height (H) to width (d)) is 6. On building surface, the pressure was measured, compared to obtained value from numerical simulation. The numerical simulations were done using URANS with three different turbulence models such as v2-f model, k-${\omega}$model, and k-${\varepsilon}$ model, respectively. The v2-f model showed the best agreement with experimental data in simulating mean pressure coefficients on front, rear and side surface. But unsteady characteristics of pressure history measured on surface is shown a discrepancy between experiment and numerical simulation.

  • PDF

Impact of Building Blocks on Inundation Level in Urban Drainage Area (지표 건물이 도시유역의 침수특성에 미치는 영향)

  • Lee, Jeong-Young;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.1
    • /
    • pp.99-107
    • /
    • 2013
  • This study is an impact assessment of building blocks on urban inundation depth and area. LiDAR data is used to generate two original data set in terms of DEM with $5{\times}5$ meter and building block elevation layer of the study drainage area in Cheongju and then the building block elevation layer is modified again to the mesh data with same size to DEM. Two-dimensional inundation analysis is carried out by applying 2D SWMM model. The inundation depth calculated by using the building block elevation layer shows higher reliability than the DEM. This is resulted from the building block interference to surface flow. In addition, the maximum flooded area by DEM is two times wider than the area by building block layer. In the case of the surface velocity, the difference of velocity is negligible in either DEM or building block case in the low building impact zone. However, If the impact of building on the surface velocity was increase, the gap of velocity was significant.

Case Study of Concrete Surface Design and Construction Method for Freeform Building Based on BIM -Focused on Tri-Bowl, Korea-

  • Ryu, Han-Guk;Kim, Sung-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.3
    • /
    • pp.347-357
    • /
    • 2012
  • While it is generally possible to install curved panels manufactured in a factory within the permitted error range on an irregular surface frame of concrete or steel, it is difficult and expensive. Freeform architecture is thus designed and constructed differently from formal buildings. In order to more easily and inexpensively actualize freeform architecture, Building Information Modeling (hereinafter referred to as BIM) has recently been applied in the construction industry. However, the related research and case analyses are not sufficient to identify the implications and contributions of freeform buildings in future similar projects. Therefore, this research will study design and construction methods for freeform surfaces, particular the concrete surface frame of freeform buildings based on BIM, focused on the Tri-Bowl project. This study attempts to analyze the pros and cons of each method for the concrete surface frame of the Tri-Bowl, and then presents the lessons learned and implications related to the design and construction process of the freeform architecture. Several implications for design and construction of concrete surface frame of the freeform building, the Tri-Bowl, are found. The first is that manufacturing and installation of a curved concrete frame is precisely performed based on the exact numerical values of materials and installation made using BIM 3D technologies, such as CATIA and Rhino. The second is that close and continuous collaboration among the different participants in the construction of the Tri-Bowl allowed them to cope with virtual conditions. The third is that design and construction processes have changed, and high quality of the surface frame of a freeform building is required.

Properties of Surface Grossing on the Design-Concreat by Developing of Design-Forms for Building Wall (건축물 벽체용 문양거푸집 개발을 통한 의장콘크리트의 표면광택 특성)

  • Oh, Jung-Keun;Gong, Min-Ho;Cho, Sang-Young;Jung, Keun-Ho;Jung, Sang-Jin;Jung, Jae-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.1
    • /
    • pp.131-138
    • /
    • 2003
  • Contemporary architecture calls for a wide range of surface textures and treatments. A surface compatible with the architect's design may vary from a glass-smooth finish to one requiring special sculptured ornamentation. These surfaces require many different types of form sheathing and lining. The purpose of study is development of new design form and made elaborateness shape. Architecture finish material not used expenses working hours, personnel expenses, architecture finish material cost. After this, building wall apply a variety shape in concrete surface and Easy to used in field.