• 제목/요약/키워드: building dynamic characteristics

검색결과 372건 처리시간 0.025초

Hysteretic characteristics of medium- to low-rise RC structures controlled by both shear and flexure evaluated by FEA and pseudo-dynamic testing

  • Ju-Seong Jung;Bok-Gi Lee;Kang-Seok Lee
    • Computers and Concrete
    • /
    • 제33권2호
    • /
    • pp.217-240
    • /
    • 2024
  • The purpose of this study is to propose new hysteretic characteristics of medium- to low-rise RC structures controlled by both shear and flexure. Through previous study, the dual lateral force-resisting system composed of shear and flexural failure members has a new failure mechanism that cooperates to enhance the flexural capacity of the flexural failure member even after the failure of the shear member, and the existing theoretical equation significantly underestimates the ultimate strength. In this study, the residual lateral strength mechanism of the dual lateral force-resisting system was analyzed, and, as a result, an equation for estimating the residual flexural strength of each shear-failure member was proposed. The residual flexural strength of each shear-failure member was verified in comparison with the structural testing results obtained in previous study, and the proposed residual flexural strength equation for shear-failure members was tested for reliability using FEA, and its applicable range was also determined. In addition, restoring-force characteristics for evaluating the seismic performance of the dual lateral force-resisting system (nonlinear dynamic analysis), reflecting the proposed residual flexural strength equation, were proposed. Finally, the validity of the restoring-force characteristics of RC buildings equipped with the dual lateral force-resisting system proposed in the present study was verified by performing pseudo-dynamic testing and nonlinear dynamic analysis based on the proposed restoring-force characteristics. Based on this comparative analysis, the applicability of the proposed restoring-force characteristics was verified.

Field measurement-based wind-induced response analysis of multi-tower building with tuned mass damper

  • Chen, Xin;Zhang, Zhiqiang;Li, Aiqun;Hu, Liang;Liu, Xianming;Fan, Zhong;Sun, Peng
    • Wind and Structures
    • /
    • 제32권2호
    • /
    • pp.143-159
    • /
    • 2021
  • The 246.8-m-tall Beijing Olympic Tower (BOT) is a new landmark in Beijing City, China. Its unique architectural style with five sub-towers and a large tower crown gives rise to complex dynamic characteristics. Thus, it is wind-sensitive, and a double-stage pendulum tuned mass damper (DPTMD) has been installed for vibration mitigation. In this study, a finite-element analysis of the wind-induced responses of the tower based on full-scale measurement results was performed. First, the structure of the BOT and the full-scale measurement are introduced. According to the measured dynamic characteristics of the BOT, such as the natural frequencies, modal shapes, and damping ratios, an accurate finite-element model (FEM) was established and updated. On the basis of wind measurements, as well as wind-tunnel test results, the wind load on the model was calculated. Then, the wind-induced responses of the BOT with the DPTMD were obtained and compared with the measured responses to assess the numerical wind-induced response analysis method. Finally, the wind-induced serviceability of the BOT was evaluated according to the field measurement results for the wind-induced response and was found to be satisfactory for human comfort.

지진에 의한 원전 보조건물 전단벽의동적 응답 특성 추정 (Seismic Response Characterization of Shear Wall in Auxiliary Building of Nuclear Power Plant)

  • 모터 라만;타미나 나하르;백건휘;김두기
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.93-102
    • /
    • 2021
  • The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.

건물일체형 풍력발전기의 진동저감 기법 연구 (A Study on Vibration Isolation Technique of Building-augmented Wind Turbine)

  • 이종원;문석준
    • 한국소음진동공학회논문집
    • /
    • 제25권3호
    • /
    • pp.160-168
    • /
    • 2015
  • Vibration issue of a building structure due to a wind turbine should be resolved for the application of building-augmented wind turbine. In this study, a dynamic analysis for an horizontal-axis upwind wind turbine is carried out to calculate vibration excited to an example building structure. Characteristics of vertical vibration transfer of the building structure are analytically studied and compared with a criteria. Then, a method to isolate the vibration is presented by analyzing the vibration characteristics of the wind turbine, and verified by applying to the building structure.

진동계측에 의한 저층 철근콘크리트조 건물의 동적특성 (The Dynamic Characteristics for Low-rise Reinforced Concrete Buildings by Vibration Measurements)

  • 강동균;윤성원
    • 한국공간구조학회논문집
    • /
    • 제3권1호
    • /
    • pp.47-55
    • /
    • 2003
  • This paper is concerned with the dynamic characteristics of buildings, especially with the measurement of the natural frequencies(natural periods) and the damping. Process of ambient vibration and synchronized human excitation tests for natural period and damping are given. Data from measurement on 16 reinforced concrete buildings in Seoul and Seoul national university of technology are given. 16 Low-rise Reinforced concrete buildings are measured for ambient vibration to obtain the vibrations characteristics. The natural periods obtained by ambient vibration measurements are compared with those of forecast model suggested by standards and foreign researchers. The natural periods show a clear dependence on building height. On the other hand, the damping ration scatter under the influence of various factors, for example, building height and natural frequency.

  • PDF

봉정사 대응전의 지진응답 특성 (Seismic Response Characteristics of the Main Building of Bongjeong Temple)

  • 주석준;홍성걸;김남희;이영욱;정성진;황종국
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2007
  • For the identification of the 3 dimensional dynamic characteristics of the Bongjeong Temple, the dynamic test for 1/3 scaled model was performed. Dynamic test with impulse excitation and vibration table excitation can provide useful data for the estimation of dynamic characteristics such as natural frequencies, damping ratios, mode shapes and stiffness center. This will complement the previous research from the 2-dimensional static test and provide the reference data for the enhanced structural analysis of the traditional wooden structures.

  • PDF

Dynamic analysis of buildings considering the effect of masonry infills in the global structural stiffness

  • de Souza Bastos, Leonardo;Guerrero, Carolina Andrea Sanchez;Barile, Alan;da Silva, Jose Guilherme Santos
    • Coupled systems mechanics
    • /
    • 제8권2호
    • /
    • pp.169-184
    • /
    • 2019
  • This research work presents a study that aims to assess the dynamic structural behaviour and also investigate the human comfort levels of a reinforced concrete building, when subjected to nondeterministic wind dynamic loadings, considering the effect of masonry infills on the global stiffness of the structural model. In general, the masonry fills most of the empty areas within the structural frames of the buildings. Although these masonry infills present structural stiffness, the common practice of engineers is to adopt them as static loads, disregarding the effect of the masonry infills on the global stiffness of the structural system. This way, in this study a numerical model based on sixteen-storey reinforced concrete building with 48 m high and dimensions of $14.20m{\times}15m$ was analysed. This way, static, modal and dynamic analyses were carried out in order to simulate the structural model based on two different strategies: no masonry infills and masonry infills simulated by shell finite elements. In this investigation, the wind action is considered as a nondeterministic process with unstable properties and also random characteristics. The fluctuating parcel of the wind is decomposed into a finite number of harmonic functions proportional to the structure resonant frequency with phase angles randomly determined. The nondeterministic dynamic analysis clearly demonstrates the relevance of a more realistic numerical modelling of the masonry infills, due to the modifications on the global structural stiffness of the building. The maximum displacements and peak accelerations values were reduced when the effect of the masonry infills (structural stiffness) were considered in the dynamic analysis. Finally, it can be concluded that the human comfort evaluation of the sixteen-storey reinforced concrete building can be altered in a favourable way to design.

Ambient vibration tests on a 19 - story asymmetric steel building

  • Shakib, H.;Parsaeifard, N.
    • Structural Engineering and Mechanics
    • /
    • 제40권1호
    • /
    • pp.1-11
    • /
    • 2011
  • Ambient vibration tests were carried out to evaluate the dynamic properties of an asymmetric steel building with semi-rigid connections. The test case has many non-structural elements, constructed in the city of Tehran (Iran). The tests were conducted to obtain natural frequencies, mode shapes and damping ratio of the structure and then Fourier transform were used to analyze the velocity records obtained from the tests. The first and second natural periods of the building were obtained as 1.37 s and 1.28 s through the test and damping ratio for the first mode was calculated as 0.047. However, Natural periods obtained from finite element model have higher values from those gained from ambient vibration. Then the model was calibrated by modeling of the in-fill masonry panels at their exact locations and considering the boundary conditions by modeling two blocks near the block No. 3, but the differences were existed. These differences may be due to some hidden stiffness of nonstructural elements in the low range of elastic behavior, showing the structure stiffer than it is in reality.

Blast-load-induced interaction between adjacent multi-story buildings

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • 제17권1호
    • /
    • pp.17-29
    • /
    • 2019
  • The present study aims to present a comprehensive understanding of the performance of neighboring multi-story buildings with different dynamic characteristics under blast loads. Two different scenarios are simulated in terms of explosion locations with respect to both buildings. To investigate the effect of interaction between the neighboring buildings in terms of the induced responses, the separation gap is set to be sufficiently small to ensure collisions between stories. An adequately large separation gap is set between the buildings to explore responses without collisions under the applied blast loads. Several blast loads with different peak pressure intensities are employed to perform the dynamic analysis. The finite-element toolbox Computer Aided Learning of the Finite-Element Method (CALFEM) is used to develop a MATLAB code to perform the simulation analysis. The dynamic responses obtained in the scenarios considered herein are presented comparatively. It is found that the obtained stories' responses are governed mainly by the location and intensity of the applied blast loads, separation distances, and flexibility of the attacked structures. Moreover, explosions near a light and flexible building may lead to a significant decrease in blast resistance because explosions severely influence the dynamic responses of the building's stories.

라멘조 건축구조물의 수직진동 전달특성에 관한 실험연구 (An Experimental Study on the Vertical Vibration Transfer according to Rahmen Building Structures due to Train Loads)

  • 전호민
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.469-475
    • /
    • 2004
  • The vibration on building structures due to exciting vibration forces has been studied only for the vibration level on existing buildings. Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the dynamic characteristics of vertical vibration transfer from lower stories to upper ones on the Rahmen building structures due to traffic loads. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on one building structures. The results of this study suggest that the characteristics of vertical vibration transfer are different in terms of the type of trains.

  • PDF