• 제목/요약/키워드: building dynamic characteristics

검색결과 372건 처리시간 0.025초

건축 구조물 제진용 대용량 하이브리드형 리니어 모터 댐퍼의 개발 (Development of a Large Capacity Hybrid-type Linear Motor Damper for the Vibration Control of Building Structures)

  • 정태영;임채욱;허영철;장석명;정상섭;김두훈;박해동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.951-957
    • /
    • 2001
  • A large capacity hybrid-type linear motor damper was designed and fabricated for the application to the vibration control of a large building structure model. It has been designed to be able to move the damper mass, 1,500kg up to $\pm$ 250mm strokes at the first mode natural frequency of the building structure model, 0.51Hz. Dynamic response characteristics of the fabricated damper were investigated by experimentally and analytically.

  • PDF

A fuzzy grey predictor for civil frame building via Lyapunov criterion

  • Chen, Z.Y.;Meng, Yahui;Wang, Ruei-Yuan;Chen, Timothy
    • Computers and Concrete
    • /
    • 제30권5호
    • /
    • pp.357-367
    • /
    • 2022
  • In this paper, we propose an efficient control method that can be transformed into a general building control problem for building structure control using these reliability criteria. To facilitate the calculation of controller H∞, an efficient solution method based on Linear Matrix Inequality (LMI) is introduced, namely H∞-based LMI control. In addition, a self-tuning predictive grey fuzzy controller is proposed to solve the problem caused by wrong parameter selection to eliminates the effect of dynamic coupling between degrees of freedom (DOF) in Self-Tuning Fuzzy Controllers. We prove stability using Lyapunov's stability theorem. To check the applicability of the proposed method, the proposed controller is applied and the control characteristics are determined. The simulation assumes system uncertainty in the controller design and emphasizes the use of acceleration feedback as a practical consideration. Simulation results show that the performance of the proposed controller is impressive, stable, and consistent with the performance of LMI-based methods. Therefore, an effective control method is suitable for seismic reinforcement of civil buildings.

Dynamic to static eccentricity ratio for site-specific earthquakes

  • Kamatchi, P.;Ramana, G.V.;Nagpal, A.K.;Iyer, Nagesh R.;Bhat, J.A.
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.391-413
    • /
    • 2015
  • Damage of torsionally coupled buildings situated on soil sites has been reported in literature, however no site-specific studies are available for torsionally coupled buildings having site characteristics as a parameter. Effect of torsion is being accounted in seismic codes by the provision of design eccentricity where the dynamic to static eccentricity ratio is a parameter. In this paper, a methodology to determine dynamic to static eccentricity ratio of torsionally coupled buildings has been demonstrated for Delhi region for two torsionally coupled buildings on three soil sites. The variations of average and standard deviations of frame shears for stiff and flexible edges are studied for four eccentricity ratios for the two buildings for the three sites. From the limited studies made, it is observed that the dynamic to static eccentricity ratios observed for site-specific earthquakes are different from Indian seismic code specified value, hence a proposal is made to include a comment in Indian seismic code. Methodology proposed in this paper can be adopted for any region, for the estimation of dynamic to static eccentricity ratio for site specific earthquake.

비틀어진 형상(Twisted) 고층 구조물의 평면 회전 각도별 동적 응답 분석 (Dynamic Response Analysis of Twisted High-Rise Structures by Plane Rotation Angle)

  • 이다혜;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제21권1호
    • /
    • pp.105-112
    • /
    • 2021
  • In this paper, the dynamic response was analyzed by performing linear dynamic analysis using historic earthquake loads on twisted-shaped structures and fixed structure among free-form high-rise structures with atypical elevation shape following prior studies. In addition, the dynamic characteristics of the analysis models according to the plane rotation angle of the twisted structure were compared and analyzed. As a result of the analysis, as the plane rotation angle of the twisted structure increased, the interlayer deformation rate increased in the high-rise part of 50th floors or more. The story shear force and the story absolute acceleration were similar in the entire structure. In the case of the story shear force, the response of the twisted shape model was rather reduced in the middle part. As a result of analyzing the dynamic response, the vulnerable layer where the response amplification of the twisted structure occurs was found to be 31st story.

Expected extreme value of pounding force between two adjacent buildings

  • Rahimi, Sepideh;Soltani, Masoud
    • Structural Engineering and Mechanics
    • /
    • 제61권2호
    • /
    • pp.183-192
    • /
    • 2017
  • Seismic pounding between adjacent buildings with inadequate separation and different dynamic characteristics can cause severe damage to the colliding buildings. Efficient estimation of the maximum pounding force is required to control the extent of damage in adjacent structures or develop an appropriate mitigation method. In this paper, an analytical approach on the basis of statistical relations is presented for approximate computation of extreme value of pounding force between two adjacent structures with equal or unequal heights subjected to stationary and non-stationary excitations. The nonlinearity of adjacent structures is considered using Bouc-Wen model of hysteresis and the pounding effect is simulated by applying the nonlinear viscoelastic model. It is shown that the proposed approach can significantly save computational costs by obviating the need for performing dynamic analysis. To assess the reliability and accuracy of the proposed approach, the results are compared with those obtained from nonlinear dynamic analysis.

동태적 고객만족 모형의 전략적 활용 - 통신서비스를 중심으로 - (A System Dynamics Approach to Building a Dynamic Customer Satisfaction Model)

  • 연승준;박상현;김상욱
    • 한국시스템다이내믹스연구
    • /
    • 제4권1호
    • /
    • pp.5-31
    • /
    • 2003
  • Customer satisfaction is generally assumed to be a significant determinant of repeat sales, positive word-of-mouth, and customer loyalty. Therefore most companies in telecommunication industry have tried to satisfy customers with high quality at low price in Korea. Even though these efforts have been tried by companies, customers are not satisfied with discrepancy between their expectation and perceived quality. Moreover, the expectation has dynamic and variable characteristics in results from various effects such n technical progress, improved quality and promotions by companies, word-of-mouth, and so on, Therefore, there are not political leverages in assessing the quality and surveying customer satisfaction index in a point of time. As an initial attempt to tackle the questions listed above, this paper puts an effort to make a dynamic customer satisfaction model to understand customer satisfaction in variable situations by introducing 'systems thinking'.

  • PDF

15층 철근콘크리트 건물에 설치된 통신설비 면진장치 동적 거동에 대한 실험적 연구 (An Experimental Study on the Dynamic Behavior of the Seismic Isolator for Telecommunication Equipment Installed in a 15-Story Reinforced Concrete Building)

  • 최형석;정동혁;서영득;백은림
    • 한국지진공학회논문집
    • /
    • 제25권6호
    • /
    • pp.241-249
    • /
    • 2021
  • Communication facilities play an essential role in disaster situations. Therefore, communication facilities need to have structural and functional safety during and after earthquakes. Recently, technology for partial seismic isolation has been increasing to protect data facilities and communication equipment installed in buildings from earthquakes. However, excessive displacement may occur in the seismic isolator during an earthquake due to the resonance between the building and the seismic isolator having long-period characteristics, which may cause overturning and separation of the installed equipment. In this study, analytical and experimental studies were conducted to evaluate the safety of seismic isolators installed in high-rise buildings. It was confirmed that damages might occur in buildings' seismic isolator, with resonance characteristics of less than 1 Hz.

Seismic fragility curves of single storey RC precast structures by comparing different Italian codes

  • Beilic, Dumitru;Casotto, Chiara;Nascimbene, Roberto;Cicola, Daniele;Rodrigues, Daniela
    • Earthquakes and Structures
    • /
    • 제12권3호
    • /
    • pp.359-374
    • /
    • 2017
  • The seismic events in Northern Italy, May 2012, have revealed the seismic vulnerability of typical Italian precast industrial buildings. The aim of this paper is to present a seismic fragility model for Italian RC precast buildings, to be used in earthquake loss estimation and seismic risk assessment by comparing two building typologies and three different codes: D.M. 3-03-1975, D.M. 16-01-1996 and current Italian building code that has been released in 2008. Based on geometric characteristics and design procedure applied, ten different building classes were identified. A Monte Carlo simulation was performed for each building class in order to generate the building stock used for the development of fragility curves trough analytical method. The probabilistic distributions of geometry were mainly obtained from data collected from 650 field surveys, while the material properties were deduced from the code in place at the time of construction or from expert opinion. The structures were modelled in 2D frameworks; since the past seismic events have identified the beam-column connection as the weakest element of precast buildings, two different modelling solutions were adopted to develop fragility curves: a simple model with post processing required to detect connection collapse and an innovative modelling solution able to reproduce the real behaviour of the connection during the analysis. Fragility curves were derived using both nonlinear static and dynamic analysis.

주파수응답함수 기반 다자유도 골조 구조물의 동특성치 도출 및 구조모델링 적용 (Derivation of Dynamic Characteristic Values for Multi-degree-of-freedom Frame Structures based on Frequency Response Function(FRF))

  • 김소연;김민영;이승재;최경규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권4호
    • /
    • pp.1-10
    • /
    • 2023
  • 구조물의 내진설계 시 지진력은 구조모델 수립 및 구조해석에 기반하여 산정되는데, 구조모델이 실제 구조물의 동특성치를 정확하게 반영하기 위해서는 실제 계측을 통한 보정이 요구된다. 본 연구에서는 실제 건물을 모사한 4층 골조 시험체를 대상으로 각 층별 가속도계를 부착하여 1축 진동대 실험을 수행하였다. 실험체의 주기는 실제 건축물의 주기와 유사하며, 수평부재의 무한강성을 고려하여 기둥은 이중곡률로 거동하도록 설계하였다. 입력지진파의 특성에 따른 영향을 고려하기 위해 다양한 주파수와 가속도 크기를 갖는 역사지진파와 인공지진파를 가력하였다. 동적응답신호를 통해 얻은 주파수응답함수를 이용하여 고유진동수와 감쇠비, 모드벡터를 도출하였으며, Mode assurance criterion(MAC)를 통해 입력지진파에 따른 모드벡터 간의 편차를 확인하였다. 또한 진동대 실험을 통해 도출된 감쇠비를 구조모델에 적용하였으며, 실험 결과와의 비교를 통하여 동특성 도출 방법을 검증하였다.

Field Measurements of the New CCTV Tower in Beijing

  • Xu, Y.L.;Zhan, S.;Xia, H.;Xia, Y.;Zhang, N.
    • 국제초고층학회논문집
    • /
    • 제2권3호
    • /
    • pp.171-178
    • /
    • 2013
  • The emergence of a growing number of tall buildings, often with unusual shapes and innovative structural systems, has led to the realization of the need for and the importance of field measurements. The new China Central Television (CCTV) Tower in Beijing is one of tall buildings with a highly unusual shape and a complex structural system, requiring field measurements to identify its dynamic characteristics for the subsequent dynamic analysis of the tower under wind excitation, seismic-induced ground motion and traffic-induced ground motion. The structural system and the finite element model of the CCTV Tower are first introduced in this paper. The computed natural frequencies and mode shapes are then presented as a reference for the field measurement. After introducing the arrangement of the ambient vibration measurement, the field measured natural frequencies and damping ratios of the CCTV Tower are presented and the measured natural frequencies are finally compared with the computed ones. It was found that the structural damping ratios of the CCTV Tower are small and the computed natural frequencies are smaller than the measured ones by about 12~17%.