• Title/Summary/Keyword: building connection

Search Result 695, Processing Time 0.023 seconds

Ultimate strength of composite structure with different degrees of shear connection

  • Kim, Sang-Hyo;Jung, Chi-Young;Ahn, Jin-Hee
    • Steel and Composite Structures
    • /
    • v.11 no.5
    • /
    • pp.375-390
    • /
    • 2011
  • Composite beam, which combined the material characteristic of the steel and concrete, has been widely used in the construction of various building and bridge system. For the effective application of the composite beam, the composite action on the composite interface between the concrete element and the steel element should be achieved by shear connectors. The behavioral characteristics of composite beam are related with the degree of interaction and the degree of shear connection according to the shear strength and shear stiffness of the stud shear connectors. These two concepts are also affected by the number of installed shear connector and the strength of composite materials. In this study, experimental and analytical evaluations of the degree of shear connection affected by stud diameter were conducted, and the relationship between structural behavior and the degree of shear connection was verified. The very small difference among the ultimate loads of the specimens depending on the change of the degree of connection was possibly because of the dependence of the ultimate load on the characteristic of plastic moment of the composite beam.

The Effects of The Creating Shared Value on Building Self-Brand Connection and Brand Loyalty (기업의 공유가치창출이 브랜드 자아 연대의식 및 브랜드 충성도 형성에 미치는 영향에 관한 연구)

  • Jin, Chang-Hyun
    • Asia-Pacific Journal of Business
    • /
    • v.9 no.4
    • /
    • pp.201-221
    • /
    • 2018
  • The purpose of this study is to investigate the relationship between association of a company's CSV activity and association of corporative competence and consumers' self-brand connection. The study examine how consumer self-brand connection affect self-identification and corporate identification as well as how these factors influenced on brand loyalty. The paper attempts to examine authenticity of CSV activity and product plays a moderating role when association of CSV and authenticity of product affects self-brand connection. a total of 700 consumers who have experience with the target company and products. A target company was selected by investigates. The company is one manufactures as well as implements CSV activities as a means of ethical management. The results indicated that CSV association and corporative competence are closely related to the self-brand connection. Such attitude in turn affected the consumers' formation of self-and corporate-identification and brand loyalty. Authenticity of CSV activity and product was proven to play a moderating variables for brand loyalty and perception of company.

Rotational Stiffness of Connection in Multi-span Vinyl Greenhouse (내재해형 연동 비닐하우스 접합부의 회전강성)

  • Kim, Min-Sun;Choi, Ki-Sun;Shin, Ji-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.3-10
    • /
    • 2018
  • Recently, severe damage to domestic horticultural structures is frequently observed due to extreme climate effects. To minimize the structures' damage, a study on the structural stability of multi-span vinyl greenhouses is needed. This paper presents to measure the rotational stiffness of different connectors to improve the design capacities of the specification. The paper investigated fourteen types of the different connectors, which was commonly used in the multi-span greenhouses, and three different types of the connectors predicted to be under moment-connection were selected: i) T-clamp, ii) U-clamp, iii) C-clamp. Static loading tests for three different connectors were performed to measure the rotational stiffness. Additionally, the boundary condition for the structural design was proposed based on the experimental results of the rotational stiffness. One of three connectors, C-clamp had larger rotational stiffness than other connectors, and the experimental results presented the three connectors had boundary conditions; i) T-clamp was pinned-connection, ii) U-clamp was semi-rigid connection, iii) C-clamp was semi-rigid connection.

Experimental Study on Pull-out Strength of Glued-in Rods Connection according to Adhesive (접착제에 따른 Glued-in Rod 접합부 인발성능에 관한 실험 연구)

  • Park, Keum-Sung;Oh, Keunyeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.2
    • /
    • pp.149-160
    • /
    • 2022
  • In this study, a pull-out test considering the adhesive type, embedded length, and direction of re-bar was conducted to evaluate the pull-out performance of glued-in rod joints using timber and adhesive produced in Korea. In the test, the specimens using liquid adhesive showed better pull-out performance, and the longer the embedded length of the re-bar, the higher the maximum tensile load by inducing the yield of the re-bar first. Through the test results, a glued-in rod joints design, which is advantageous to design the adhesive strength stronger than the yield strength of re-bar, was proposed, and a correction factor of 0.75 for the adhesive strength considering construction error was also suggested.

Evaluation and Selection of Building Materials based on Life Cycle Cost Prediction (생애주기비용 예측 기반 건물재료 경제성 평가 및 선정)

  • Ahn, Junghwan;Lim, Jinkang;Oh, Minho;Lee, Jaewook
    • Journal of KIBIM
    • /
    • v.5 no.2
    • /
    • pp.34-45
    • /
    • 2015
  • As buildings become larger and more complicated, construction costs have increased with a considerable effect on buildings' Life Cycle Cost (LCC). However, there has been little consideration on economic aspects in the selection of construction materials due to limited information on the materials and dependency in architects' experience and inefficiency in cost estimation, causing design changes, increase in maintenance cost, difficulty in budgeting, and decrease in building performance. To solve these problems, this study proposed a BIM-based material selection model which reflects the comprehensive economic efficiency of building materials. Our cost prediction model can estimates the material-related cost during the entire building life cycle. Furthermore, we implemented the proposed model in connection with BIM, which can analyze and compare LCC by material. Through the validation of the model, we could confirm the necessity of LCC-based material selection in comparison with the conventional cost-centered material selection.

Study on the check list composition at Sustainable building strategies and Design methods of Long-life housing (장수명 공동주택의 친환경 요소기술 및 계획기법 체크리스트 구성에 관한 연구)

  • Han, Nam-Soo;Lee, Young
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.103-112
    • /
    • 2010
  • This Study is about the check-List composition for 'Low carbon green growth' of Long-life housing. That utilization for required the check-list composition at Sustainable building strategies and Design methods. That for long life housing, sustainable building strategies part of building construction and interior, the proper foundation for legislative system, maintenance methods with in building life cycle, sustainable and green architecture capability realization prepare for connection plan with 'Low carbon-green growth'. Extracting from elements of Architectural planing answer to basic concept of Low carbon-green growth and aimed at Low carbon scheme for energy saving, green growth scheme for environmental conservation as to each application purpose reconstitute by classify Check-list category about elements of Architectural planing. Through this architectural research deduce elements of architectural planing that can be research utilization with in Check-list composition.

Improving Data Input of ECO2-OD Program Utilizing BIM (BIM을 이용한 ECO2-OD 프로그램의 정보입력 개선)

  • Kang, Min-Su;Kim, Ka-Ram;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.205-207
    • /
    • 2013
  • In a situation that building energy consumption is increasing worldwide, the research utilizing BIM technology to analyze building energy has been actively conducted. On the other hand, data input method of the building energy analysis has been still manually entered. This paper proposed a improved input method of required information for building energy analysis using the ECO2-OD program. As a result, although some required information of BIM based design software could be almost entered when it comes to general information and architectural sector, it has a problem to be handled in HVAC sector. Therefore, in the both of general and architectural sectors, the BIM information from the BIM-based design software could be directly used to automatically and systematically input the information. Future research should be studied the algorism and method in connection with data exchange to utilize input method of ECO2-OD from BIM data.

  • PDF

Study on the Connection Node System of Irregular-shaped Curtain wall Facade using 3D Printed Smart Node System (자유형상 커튼월 구현을 위한 3D 프린팅을 활용한 스마트노드 시스템의 연구)

  • Na, SangHo;Yoo, SeungKyu;Park, YoungMi;Park, JungJoon;Kim, SungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.8-9
    • /
    • 2018
  • 3D printing has the unique advantage of the ability to customize freeform product even in small quantity. However, we need to select and apply the only necessary parts of it because of the high cost of the manufacturing technology. It is of critical importance in irregular-shaped curtain walls to ensure precision of construction as well as quality fo finish. Complex shape that have structural members at varying angles can have nodes of different shapes making it unfeasible to construct using a general node connection detail. Therefore, this study aims to utilize smart node system using 3D printing as a solution to complex irregular-shaped curtain wall design.

  • PDF

Structural Characteristic of Beam-to-Column Connections in Rectangular CFT Structures Considering Concrete Filling (충전성을 개선한 각형CFT 기둥-보 접합부의 구조 특성)

  • Park, Je Young;Lee, Myung Jea
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • CFT structures require a diaphragm to prevent buckling of steel at connections. An outer diaphragm has better concrete filling than a through diaphragm due to a large bore, but due to the larger size than the through diaphragm, it has poorer constructability and cooperation with building equipment. The building structure has a floor slab that was unified with the upper diaphragm, so the outer diaphragm was placed at the upper bound. Moreover, the through diaphragmwas placed at the lower connection to avoid obstruction of the building equipment. The CFT structure with the improved concrete filling showed the same structural behavior as the CFT structure with the use of the same type of diaphragms at the upper and lower connections.

Comparison of Turkish Steel Building Specifications, TS 648 and SDCCSS 2018

  • Bozkurt, Mehmet Bakir;Ergut, Abdulkerim;Ozkilic, Yasin Onuralp
    • Steel and Composite Structures
    • /
    • v.45 no.4
    • /
    • pp.513-533
    • /
    • 2022
  • This study presents similarities and differences between Turkish Building Code for Steel Structures, which are TS 648 and SDCCSS (Specification for Design, Calculation and Construction of Steel Structures) in terms of the design of the members. Hot-rolled I-shaped steel sections for symmetrical and U-shaped steel sections (i.e., channels) for monosymmetric sections were elaborated in detail. The design strength of tension members under tensile load, compression members under axial load and flexural members under flexure and shear were examined separately. Connection details for tension members, slenderness for compression members and distance between lateral supports for flexural members were considered as prime variables. Analysis results revealed the design strength of the tension members where at least one of the cross-sectional parts is not connected to the connection plates, I-shaped compression members where a slenderness ratio is below 39 (𝛌<39), U-shaped compression members and flexural members where Lb is between Lp and Lr (Lpb≤Lr) designed based on TS 648 are greater than those designed based on SDCCSS 2018. Strength differences between the specification can reach 79% for tensile members, 13% for compression members and 9% for flexural members.