• Title/Summary/Keyword: building complex

Search Result 1,565, Processing Time 0.031 seconds

A Study on the Quality Control Effectiveness in the High-rise residential-commercial Complex Building Project (초고층 주상복합건물의 품질관리 효율성에 관한 연구)

  • Kim, Suk-Hoi;Im, Chil-Soon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.4
    • /
    • pp.79-87
    • /
    • 2007
  • The object of this study is to understand of the effectiveness characteristic in the field work which is controlled by the quality in the high-rise residential-commercial complex building. From the previous study, the quality improvement factors are investigated. Through the structured questionnaire, the opinions of the field engineers(University, Design firms, Construction company) are gathered in the improvement factors of construction phase. Comparing the results of questionnaire with the conception of field engineers, this study helps in revising and improving the quality control system including tangible factors and intangible factors in the frame work of the high-rise residential-commercial complex building project.

  • PDF

Development of an Information Framework for Representing 3D Object-based Model of Complex Facilities as 2D Drawing - Focusing on the Building Service Objects - (복합시설물의 3D 객체기반 모델의 2D 표현을 위한 정보체계 개발 - 빌딩서비스 객체를 중심으로 -)

  • Kang, Byung-Chul;Choi, Sam-Rak;Kim, In-Han;Kim, Hak-Doo;Kim, Mi-Hui;Kwon, Jeong-Min
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Recently, the needs for sharing and exchanging drawing information between 2D and 3D data in complex facilities are well recognized throughout the construction industries. The purpose of this study is to propose an information framework to represent 3D IFC (Industry Foundation Classes) -based drawing of building services in complex facilities as 2D drawing. In this study, 1) attributes of building service objects which are used in 3D CAD system are analyzed and present drawing standards are analyzed, 2) based on the analysis, an information framework is developed to represent 3D model in 2D representation, and 3) further more, to test a compatibility of the information sharing framework, number of standardized APIs and an IFC2Dbrowser are developed during the study.

Structural Design of Nakanoshima Festival Tower

  • Okada, Ken;Yoshida, Satoshi
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.173-183
    • /
    • 2014
  • Nakanoshima Festival Tower is a 200 m high-rise complex building which contains a renewed 2700-seat capacity concert hall known as "Festival Hall" and offices including headquarter of a news company. In order to build up an office tower on the hall which requires large open space, a giant truss system is employed. The giant trusses being composed of mega-trusses and belt-trusses support all the building weight above them and transfer the load to the outside of the hall. The building also requires high seismic resistance performance for a news company. Application of mid-story seismic isolation enables the building to satisfy high-level seismic resistance criteria.

TECHNIQUE OF EXTRACTING BUILDING BOUNDARIES FROM SEGMENTED ALS POINTS

  • Lee, Jeong-Ho;Kim, Yong-II
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.141-144
    • /
    • 2008
  • Many studies have been conducted on extracting buildings from ALS(Airborne Laser Scanning) data. After segmentation or classification of building points, additional steps such as generalization is required to get straight boundary lines that better approximate the real ones. In much research, orthogonal constraints are used to improve accuracies and qualities. All the lines of the building boundaries are assumed to be either parallel or perpendicular mutually. However, this assumption is not valid in many cases and more complex shapes of buildings have been increased. A new algorithm is presented that is applicable to various complex buildings. It consists of three steps of boundary tracing, grouping, and regularization. The performance of our approach was evaluated by applying the algorithm to some buildings and the results showed that our proposed method has good potential for extracting building boundaries of various shapes.

  • PDF

Study on the Change of Wind Field and Temperature According to Location of High-rise Building Using Micrometeorology Numerical Model (미기상 수치 모델을 이용한 고층아파트 입지에 따른 바람장 및 기온 변화 연구)

  • Seo, Houng-Seok;Kim, Yoo-Gon;Young, Go-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.340-352
    • /
    • 2011
  • This study was carried out to analyze the change of wind filed and heat island according to the location of the high rise building using micrometeorology numerical model Envi-met3.0. In this study, the real urban planning of Jeonju city was used as input for the location and height of buildings. Modeling was performed for two conditions as input data. Case 1 is that wind direction is SSE and case 2 is W. To analyse the change of wind filed, wind speed results were used. To analyze the change of heat island, temperature results were used. Below the building height, wind speed increased 0.2~2.5 m/s at the inflow area and decreased 0.5~2.0 m/s at the area between the buildings. Above the building height, wind speed decreased 0.1~0.8 m/s near the building complex. On the other hand, wind speed increased 0.2~0.4 m/s in the outside area of the building complex. In the case of temperature, below the building height, temperatures increased $0.01{\sim}0.1^{\circ}C$ in the building complex and leeward area. On the other hand, temperature decreased $0.01{\sim}0.005^{\circ}C$ in the outside area of the building complex. Above the buildings height, temperatures decreased $0.05{\sim}0.2^{\circ}C$ in most of the area.

A Study on the Right of Light Impact at Adjacent Residential Area by High-rise Residential Commercial Complex Building (상업지역내 고층건물의 인접주거 지역 일조권 영향에 관한 연구)

  • Lee, Sang-Hwa;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.10-18
    • /
    • 2009
  • In order to determine the violation of right of light impact at adjacent residential area by high-rise building, analysis on the right of light for high-rise residential commercial complex building block at Gahngnam-ku, Seoul, Korea was carried out using Google Sketchup Pro. After the analysis th sunshine duration of B apartment decreased from 5 hours 16 minutes 3 hours 48 minutes by I hour 42 minutes after construction. It shows that the total sunshine duration is less than the Seoul City Government Standard which is more than 4 hours a day, or more than 2 consecutive hours. Lowering the heights of apartments by 54m would increase the total sunshine duration which would meet the Seoul City Government Standard by four hours seven minutes. Problems that rna lead to the violation on the right of light in the adjacent area should be discussed in advance and minimized by analyzing the right of light among buildings and structures which are scheduled to be constructed on the site during construction penni! process when high-rise building is proposed.

An Analysis of Heating and Cooling Energy Cost according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 비용 분석)

  • Roh, Ji-Woon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.96-105
    • /
    • 2013
  • This study aims to investigate the energy performance of apartment in respect of complex design, building type and generation house layout and finally to produce the guide line for energy saving design. To grasp the present condition and problem about this subject, apartment building types were examined and representative types were extracted. Considering azimuth angle, private area, and generation number, building type of the subject apartment was classified in detail, energy simulation was conducted, and the effect to energy cost was compared. In the research, using VE energy simulation program, the heating and cooling load were calculated and converted to energy cost. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Energy cost is compared according to several azimuth in plank '一' type apartment. As the results, calculated gas cost is the best in $49^{\circ}$, but total cost is in $-31^{\circ}$. 2) Apartment buildings of tower types are compared, it is resulted that 'Y' type (azimuth $-7^{\circ}$, $-20^{\circ}$) is the best in gas cost, but the total cost is worst because of high cooling load.

Study on the Space Composition Characteristics in the Urban Complex Building (도심복합시설의 공간용도구성 특성에 관한 연구)

  • Lee, Kang-Hee;Chae, Chang-U
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.109-116
    • /
    • 2010
  • The city means not only a geographical area as a role of the spatial boundary, but also a socio-economic place to communicate with each area. It requires various functions to get the income and economic-activities. But city has a limitation of a available land to provide the required functions and a sufficient space to supply the urban activity. Therefore, the development trend of city has not been to spread to the horizontal area any more and considered the vertical area. In addition, various functions put into a massive building because many people want to solve the daily requirements without spending time and cost in outer area. In this paper, it aimed at classifying the mixed-use building into function, circulation, relation according to the public and private space and the building shape to provide the design information such as land area, functional complex, accessibility, etc.. The classification of the mixed-use buildings is divided into four areas. The data are collected with foreign countries in Japan, Europe and US. Results of the study are as follows; First, the commercial function is mainly centered with other functions. Second, after studied the development scale, accessibility, building form, the commercial and residential area overwhelmly share at the total area.

An Investigative Study on the Structural Characteristics of High-Rise Complexes in Korea (국내 고층 주상복합 건물의 구조적 특성에 관한 조사 연구)

  • Kang Suk-Won;Lee Sung-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.137-144
    • /
    • 2003
  • Recently, the interest in a complex building increases rapidly in Korea. High-rise complex is not simply the combination of a residential apartment and a business office as previous but a building with the object of the convenience of the residents familiar with city-life style through adapting the high class life style and new residential culture to the business space, and the efficiency in using the limited building site in the town. This study presents an exploratory analysis focusing the structural system with the help of the extensive survey of the construction site in Korea, and aims a guideline for the structural design and construction of high rise complex. Through the survey, change and development in the design and the construction can be seen as the height and size of the complex grow. It is almost indispensable to design a structural system against lateral forces like earthquake or wind, which is usually measured by story drift ratio or story displacement. Improvement of the structural materials and their usages is also included for the efficiency of the structural system. Useful slab-beam system contributing to the decrease of the story height is still a concern.

Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building (주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토)

  • Park, Kwang-Seob;Kim, Yun-Tae;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.33-40
    • /
    • 2019
  • A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.