The Characteristics of Bubbles in a Column Heat Exchanger for the Application of Direct Contact LNG Evaporator (직접접촉식 LNG기화기 응용을 위한 칼럼 열교환기 기포특성에 관한 연구)

  • Kim, S.J.;Han, S.T.;Kim, J.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.142-151
    • /
    • 1991
  • In the present investigation, it has been proposed to utilize a direct contact heat exchanger as an evaporator to solve the difficulties such as scaling, corrosion and law thermal efficiencies, associated with the conventional evaporator. Liquified nitrozen was utilized as a working fluid to investigate basic natures of bubble dynamics in the evaporator, and spray nozzles were adopted to inject liquified nitrozen into the spray column with varying flow rates of dispersed phase fluids. Experimentations were carried out in the range of $6.54{\times}10^{-4}kg/s$ - 0.030 kg/s for dispersed phase flow rates with one, three and five nozzle holes. Observing the bubble dynamics for the evaporator the feasibility of utilizing a direct contact heat exchanger as a LNG evaporator has been evaluated. The results show that no eruption phenomena was observed in the present investigation with $LN_2$ and the interface between $N_2$ bubbles and water was fully turbulent. It is believed that the high injection velocity of $LN_2$ through the spray nozzles provide good mixing effects for both heat and mass transfers between water and $N_2$ bubbles. Ice was formed on the surface of the spray nozzle for higher $LN_2$ flow rates. However, even in this case, it is observed that the ice was detached as soon as it was formed. Under the present experimental conditions, the shapes of $LN_2$ bubbles were in the spherical-cap region according to the Clift, Grace and Weber Graphs. The height of foam region caused by the breakup of larger bubbles keeps increasing with high injection velocities until it reaches it's maximum height.

  • PDF

The Effects of Acetate and $CO_2$ Supplements for Cell Growth of Haematococcus pluvialis in Bubble Column Photobioreactors

  • Seo, Mun-Won;Lee, Cheol-Gyun
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.298-300
    • /
    • 2001
  • Haematococcus pluvialis was cultured autotrophically and mixotrophically for astaxanthin production in bubble column photobioreactors with $CO_2$ and/or acetate supplements. Four different schemes were tested using 5% $CO_2$ balanced with 95% $N_2$ at the aeration rate of 0.1 vvm and supplementation of acetate (l g/L) to the basal medium, MBBM. Average specific growth rates based on cell total volume of each case were 0.138 $day^{-1}$ in control (without $CO_2$ and acetate supplements), 0.125 $day^{-1}$ with only acetate supplementation, 0.315 $day^{-1}$ with only $CO_2$ supplement, 0.304 $day^{-1}$with both $CO_2$ and acetate. The growth rate under $CO_2$ supply was much higher than that without $CO_2$ supply. DCO and DO seemed to be a possible limitation factor. Another interesting observation was the growth rate under $CO_2$ supplement (without acetate) was higher than that under both $CO_2$ and acetate supply. This result is the opposite of the previously reported works. From the result, the existence of acetate may suppress the dark reaction of $CO_2$ fixation or photosynthesis. Conclusively, the growth of H. pluvialis under photoautotrophic condition found to be higher than that under mixotrophic condition.

  • PDF

Specific Light Uptake Rate Can be Served as a Scale-Up Parameter in Photobioreactor Operations

  • Lee, Ho-Sang;Kim, Z-Hun;Jung, Sung-Eun;Kim, Jeong-Dong;Lee, Choul-Gyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.12
    • /
    • pp.1890-1896
    • /
    • 2006
  • Lumostatic operation for cultivation of Haematococcus pluvialis was assessed to test the scale-up strategy of photobioreactors. Lumostatic operation is a method of maintaining a proper light condition based on the specific light uptake rate ($q_e$), by cells. Lumostatic operations were performed in 0.4-, 2-, 10-, and 30-1 scale bubble column photobioreactors and the results were compared with cultures illuminated with constant light intensity. Significant differences were observed in the maximal cell concentrations obtained from 0.4-, 2-, 10-, and 30-1 scale photobioreactors under constant light intensity, yielding the maximal cell concentrations of $2.8{\times}10^5$, $2.2\times10^5$, $1.5\times10^5$, and $1.1\times10^5$ cells/ml, respectively. The maximal cell concentration in a 0.4-1 photobioreactor under lumostatic operation was $4.3\times10^5$ cells/ml. Furthermore, those in 2-, 10-, and 30-1 scale photobioreactors were about the same as that in the 0.4-1 photobioreactor. The results suggest that lumostatic operation with proper $q_e$ is a good strategy for increasing the cell growth of Haematococcus pluvialis compared with a constant supply of light energy. Therefore, lumostatic operation is not only an efficient way to achieve high cell density cultures with minimal power consumption in microalgal cultures but it is also a perfect parameter for the scale-up of photobioreactors.

Botryococcus braunii 배양에서 탄화수소의 two-stage 동시추출공정

  • An, Jin-Yeong;Choe, Jeong-Gyu;Sim, Sang-Jun;Kim, Byeong-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.229-232
    • /
    • 2000
  • The carbon dioxide, nitrogen, and phosphate removals from wastewater using microalgae have extensively been studied. Especially, the green colonial algae Botryococcus braunii is characterized by unusual high hydrocarbon contents, ranging from 15 to 75% of dry weight, as long-chain unsaturated hydrocarbons. These hydrocarbons suggest that the possibility of renewable biofuels to be converted into useful fuels such as gasoline by simple catalytic cracking. The poor recovery (18 - 32%) of hydrocarbon from B. braunii culture in two-phase bubble column seems to be caused by insufficient mixing between two phases, which was operated using only aeration on the narrow interface between hydrophobic solvent and cell suspension. In addition, hydrocarbon was entrapped tightly in cell-matrix (formed by exopolysaccharide) of algal colony, which make difficult to extract using two-phase system. In order to overcome low recovery efficiency, two-stage extraction culture system including culture vessel and two-phase separator is now under development, resulted improving contact between solvent phase and cell suspension. Hydrocarbon recovery using this process was more than two times as that using two-phase extraction culture.

  • PDF

이상추출배양을 통한 Botryococcu braunii에서의 탄화수소 생산

  • Sim, Sang-Jun;An, Jin-Yeong;Kim, Byeong-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.112-115
    • /
    • 2002
  • The green colonial algae Botryococcus braunii is characterized by unusual high hydrocarbon contents, ranging from 15 to 75% of dry weight, as long-chain unsaturated hydrocarbons. In two-phase bubble column using various organic solvents, poor recovery 08 - 32%) of hydrocarbon seems to be caused by insufficient mixing between two phases, which was operated using only aeration on the narrow interface between hydrophobic solvent and cell suspension. In addition, hydrocarbon was entrapped tightly in cell-matrix (formed by exopolysaccharide) of algal colony, which make difficult to extract using two-phase system. To improve recovery efficiency, mixed-solvent of extractive solvent (octane) and biocompatible solvent (octane) was tested in two-phase column for in situ extraction. In two-phase extraction culture using mixed-solvent, the algal growth was intensely inhibited even at low concentration of polar octanol solvent. the hydrocarbon recovery in two-stage cell-recycle extraction showed a 2.9 fold increase (57%) over that in two-phase extraction. Up to 60 % of hydrocarbon could be recovered without serious cell-damage in the case of downstream separation for 6 h at the high recycle flow rate using this process after batch culture.

  • PDF

Far Ultraviolet Observations of the Spica Nebula and the Interaction Zone

  • Choi, Yeon-Ju;Park, Jae-Woo;Lim, Tae-Ho;Min, Kyoung-Wook;Seon, Kwang-Il;Jo, Young-Soo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.99.1-99.1
    • /
    • 2012
  • We report the results of our analysis of far ultraviolet (FUV) observations made for the broad region around the ${\alpha}$ Vir (Spica) including the interaction zone of the Loop I and the Local Bubble. We employed the datasets of the GALEX and the FIMS, which made observations at similar FUV wavelengths. First, we noted that the GALEX image was enhanced in the southern region where the interaction zone exists. We attribute this enhanced FUV emission to dust scattering of the stellar photons, mostly from the background field stars with small contributions from the central star Spica. While the region is optically thin in general, the FUV intensity did not correlate well with the dust extinction level, indicating that the local radiation field has significant fluctuations. On the other hand, the GALEX FUV intensity well with the $H{\alpha}$ intensity as well as the dust extinction level in the northern part. In fact, the neutral hydrogen column density correlated very well with the dust extinction level throughout the whole region in consideration. The relationship between the neutral hydrogen column density and the color excess was estimated to be ${\sim}7{\times}10^{21}atoms\;cm^{-2}$, which is a little higher than the previous observations made for a diffuse interstellar medium. The spectral analyses of the FIMS observations showed the enhanced C IV emission throughout the whole region, indicating that the C IV emission arises by the interaction of the hot gases with the shell boundaries. A simple model showed that a large portion of the C IV emission comes from the Loop I side of the interaction zone, compared to the Local Bubble side. The FIMS spectrum also showed indications of the molecular hydrogen fluorescence lines for the interaction zone.

  • PDF

Enhancement of Carbon Dioxide Fixation by Alteration of Illumination during Chlorella Vulgaris-Buitenzorg's Growth

  • Wijanarko Anondho;Dianursanti Dianursanti;Gozan Misri;Andika Sang Made Krisna;Widiastuti Paramita;Hermansyah Heri;Witarto Arief Budi;Asami Kazuhiro;Soemantojo Roekmijati Widaningroem;Ohtaguchi Kazuhisa;Koo Song-Seung
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.6
    • /
    • pp.484-488
    • /
    • 2006
  • Alteration of illumination with optimum carbon dioxide fixation-based curve in this research successfully enhanced the $CO_{2}-fixation\;(q_CO_{2}$ capability of Chlorella vulgaris Buitenzorg cultivated in a bubble column photo bioreactor. The level of $CO_{2}$ fixation was up to 1.91 times that observed from cultivation with intensification of illumination on an optimum growth-based curve. During 144 h of cultivation, alteration of light intensity on an optimum $CO_{2}-fixation-based$ curve produced a $q_CO_{2}$ of $12.8\;h^{-1}$. Meanwhile, alteration of light intensity with a growth-based curve only produced a $q_CO_{2}$ of $6.68\;h^{-1}$. Increases in light intensity based on a curve of optimum $CO_{2}-fixation$ produced a final cell concentration of about 5.78 g/L. Both cultivation methods were carried out under ambient pressure at a temperature of $29^{\circ}C$ with a superficial gas velocity of $2.4\;m/h(U_{G}$. Cells were grown on Beneck medium in a 1.0 L Bubble Column Photo bioreactor illuminated by a Phillips Halogen Lamp (20 W/12 V/50 Hz). The inlet gas had a carbon dioxide content of 10%.

Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process (원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법)

  • Son, Bong-Ho;Lim, Bong-Su;Oa, Seong-Wook;Lee, Byung-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

Gas hold-up variation with sparging direction in bubble column (기포탑 반응기에서 기체 분사 방향에 따른 gas hold-up 변화)

  • Yang, Jung Hoon;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Lee, Ho-Tae;Jung, Heon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.112.2-112.2
    • /
    • 2010
  • 슬러리 기포탑 반응기는 열 및 물질 전달의 용이성, 낮은 운전비용 및 장치의 간단성의 장점을 가지고 있어서 Fischer-Tropsch 반응, bio-reaction 등에 많이 응용되고 있다. 그러나 기포탑 반응기 내의 물질 거동은 매우 복잡하기 때문에 많은 연구가 이루어지고 있음에도 불구하고 그 현상에 대한 명확한 이해는 어려운 상황이다. 특히 기포탑반응기내에 기체의 포집율(gas hold-up)을 증가시키는 것을 목적으로 하는 연구들이 활발히 진행되고 있다. 본 연구에서는 기체의 분사 방향에 따른 기체 포집율의 변화를 관찰하였다. 기체 분사는 0.6 mm의 pore가 66개로 구성된 perforated plate를 통해서 이루어졌고, 수직방향, 수평방향, 45도 그리고 수직/수평 조합의 네 가지 분사방향에 대해서 실험을 수행하였다. 반응기는 내경이 0.15 m이고 높이 2.0 m 아크릴 반응기를 이용하였다. 사용된 연속상은 수돗물을 사용하였고 분산상 기체로는 압축 공기를 이용하였다. 전체적인 기체 포집율은 수직방향의 분사방향에서 가장 높게 측정되었다. 그리고 수직/수평의 조합 분사방향의 경우, 기체 포집율이 가장 낮게 관찰되었다. 이것은 분사방향이 수직/수평으로 서로 엇갈릴 경우, 기포간의 충돌 가능성이 높아지고 bubble coalescence가 증가하였기 때문인 것으로 보인다. 실제로 homogeneous flow regime에서 heterogeneous flow regime으로 전환되는 기체선속도는 분사방향이 수직, 45도, 수평, 수직/수평 조합의 순서로 감소하였다. 즉 이 순서로 기체흐름의 와류가 증가하는 것을 알 수 있었다. 또한 Dynamic Gas Disengagement(DGD) 분석을 통하여 큰 기포가 발생하기 시작하는 기체 선속도의 변화를 관찰하였다. 이 경우, 예상되듯이 수직/수평 조합에서는 1.5 cm/sec 기체 선속도에서 큰 기포가 발생하기 시작한 반면 수직 방향 분사의 경우에는 2.5 cm/sec의 보다 높은 기체 선속도에서 관찰되기 시작하였다. 이러한 현상들을 종합하였을 때, 기체 분사방향을 수직으로 일정하게 했을 때, 기포간 출동을 최소화하고 와류발생을 최대한 지연시키며 전체 기체 포집율을 증가시킬 수 있음을 알 수 있다.

  • PDF

Comparison of Growth Characteristics of Tricholoma matsutake Mycelium Among the Types of Air Bubble Bioreactor (공기부양식 생물반응기의 형태별 송이균사의 생장특성 비교)

  • Lee, Wi-Young;Ahn, Jin-Kwon;Ka, Kang-Hyeon;Kwon, Young-Jin
    • The Korean Journal of Mycology
    • /
    • v.31 no.2
    • /
    • pp.89-93
    • /
    • 2003
  • In order to select suitable bioreactor type inhibiting cell stress during submerged culture of Tricholoma matsutake mycelium, the growth characteristics and ergosterol contents were investigated using the external-loop type of air-lift bioreactor (ETAB), balloon type of air bubble bioreactor (BTBB) and column type of air bubble bioreactor (CTBB). Dry weights of the T. matsutake in the BTBB, ETAB and CTBB were 12 g, 11.4 g, and 9.5 g per 1 litter, respectively. BTBB, ETAB and CTBB reached stagnant phases 16, 20, and 24 days after cultivation, respectively, The BTBB was more suitable for liquid culture of T. matsutake mycelium compared to other bioreactors owing to much mycelia product and short culture period. The ergosterol contents produced by the mycelium in the bioreactors were in sequence of BTBB, CTBB, and ETAB at every growth phase. BTBB might affect the mycelium on producing the smallest size of pellets. BTBB and CTBB got the mycelium precipitated and coagulated under operation of bioreactor sparser, whereas ETAB shown no effect of above phenomenon. A renovated bioreactor combined between a balloon shape of BTBB and an external-loop of ETAB was developed to enhance the efficiency of culture technique.