• 제목/요약/키워드: broken wires

검색결과 15건 처리시간 0.025초

와이어 로프의 파단특성에 관한 실험적 연구 (An Experimental Study on the Fracture Characteristics of Wire Ropes)

  • 김종현;이근오;태순호
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.3-10
    • /
    • 1994
  • This study examines fracture characteristics of wire rope of 6$\times$37+FC 14mm B degree, Which has been widely used for the strength support for machinery, cranes and shipping. The examination Is based on the fellowing experimental conditions. Firstly, this study analyzes the effect of the strength of wlre rope. When number of broken wires is occuring at the level of 5%, 10% and 15% degree respectively in the following two cases:1) Case of broken down to each strand equally. 2) Case of broken down to one strand only. Secondly, this study analyzes the effect of corrosion on the strength of wire rope. Corrosion times are 72hours, 144hours and 216hours corrosion respectively under following conditions. 1) Case of only a corrosion without wire breaking. 2) Case of corrosion after 5% degree wire breaking to each strand equally. Some outcomes of these experiment are as follows. 1) From the of tension test, We can find that the ratio of strength reduction case of wire broke down to one strand concentrically is greater than that ratio case of broke down to each strand equally. 2) From the corrosion test, We can also find that the ratio of strength reduction case of corroded after 5% degree wire breaking to each strand equally Is greater than that ratio case of corroded without wire breaking. 3) After comparing theoretical fracture load of wires with experimental fracture load of wires, we can find the fracture load of the case of broken down to each strand equally is most similar to theoretical fracture load. 4) It is proposed that safety rules on wire rope in the Industrial safety and healthy labor of law have to change “breaking over 10% of number of wires in one strand of wire rope(excluded filler wire )”has to be replaced by“breaking over 10% of number of all wires in all strand of wire rope(excluded filler wire)”

  • PDF

LASER WELDING OF TI-NI SHAPE MEMORY ALLOY WIRE

  • Kim, Young-Sik;Kim, Jong-Do
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.139-144
    • /
    • 2002
  • Ti-50.9at%Ni wires were welded using pulsed YAG laser. The laser welded wires were tested for investigating the shape memo교 effect and the ability of super elasticity. The fatigue properties of the welded wires were investigated using the rotary bending fatigue tester specially designed for wires. Moreover, the effect of defocusing distance during laser welding on the static and fatigue properties was investigated. The shape memory effect and super elasticity of the laser welded wires were approximately identical with that of base metal at the test temperature below 353K. However, the welded wires were broken within elastic limit at the test temperature above 353k. Under the cyclic bending loading conditions, the welded wires could be useful only below the elastic limit, while the base metal had sufficient fatigue life even the stress induced M-phase region. The fatigue strength of the welded wires was about half of that of the base metal. The deterioration of the static and fatigue properties in the welded wires was proven to be from the large difference of the transformation behavior between the base metal and welded part that is caused by vaporization of Ni-content at the welded part during the welding process. The defocusing distance below 3mm acted more largely on lowering the strength of the welded wires than that of 6mm or 8mm.

  • PDF

Fatigue Properties of Ti-Ni Shape Memory Alloy Wire Welded by Nd: YAG Laser

  • Kim, Y.S.;Kim, J.D.;Kil, B.L.
    • International Journal of Korean Welding Society
    • /
    • 제3권1호
    • /
    • pp.39-44
    • /
    • 2003
  • The welded specimens were made by butt welding of the 2 wires of 50mm length using the pulsed YAG laser. The laser welded wires were tested for investigating the shape memory effect and the ability of super elasticity. The fatigue properties of the welded wires were investigated using the rotary bending fatigue tester specially designed for wires. Moreover, the effect of defocusing distance during laser welding on the static and fatigue properties was Investigated. The shape memory effect and super elasticity of the laser welded wires were approximately identical with that of base metal at the test temperature below 353K. However, the welded wires were broken within elastic limit at the test temperature above 353k. Under the cyclic bending loading conditions, the welded wires could be useful only below the elastic limit, while the base metal had sufficient fatigue life even the stress induced M-phase region. The fatigue strength of the welded wires was about half of that of the base metal. The deterioration of the static and fatigue properties in the welded wires was proven to be from the large difference of the transformation behavior between the base metal and welded part that is caused by vaporization of Ni-content at the welded part during the welding process. The defocusing distance below 3mm acted more largely on lowering the strength of the welded wires than that of 6mm or 8mm.

  • PDF

리스프랑 관절 골절 및 탈구: 나사와 Kirschner 강선을 이용한 치료 (Fracture and Dislocation of Lisfranc Joint: Treatment with Screw and Kirschner Wire)

  • 하동준;김전교;곽희철;장의찬
    • 대한족부족관절학회지
    • /
    • 제19권4호
    • /
    • pp.181-187
    • /
    • 2015
  • Purpose: The purpose of this study is to retrospectively analyze the clinical results of screws and Kirschner wire (K-wire) fixation in patients with fracture dislocation of Lisfranc joint and the consequence of screw breakage. Materials and Methods: Sixty patients underwent Lisfranc joint open reduction and removal of internal fixators from January 2007 to December 2011. Forty-nine cases (81.7%) underwent operations with screw alone, and 11 cases (18.3%) underwent operations with both screws and K-wires. Type of internal fixators, duration of internal fixator removal, breakage of internal fixators and satisfaction with reduction were investigated. Additionally, American Orthopaedic Foot and Ankle Society (AOFAS) midfoot scales were analyzed. Results: The internal fixator was broken in 5 cases (8.3%). The average duration of instrument removal was 154 days in the non-broken screw group and 268.6 days in the broken screw group (p<0.05). The average AOFAS midfoot scale was 77.4 in the non-broken screw group and 74.2 in the broken screw group. The most commonly damaged portion was the first tarsometatarsal (Lisfranc) joint. Conclusion: Treatment with screws and K-wires was effective in patients with fracture dislocation of Lisfranc joint. The appropriate time for screw removal should be considered.

냉점보상과 단선감지 기능을 갖는 R-형 열전쌍 인터페이스 설계 (Design of R-type thermocouple interface with cold-junction compensator and its broken wire detection)

  • 차형우;김영선;박소현;현필수;김대한;윤영식;유호영;김병조
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.847-848
    • /
    • 2006
  • R-type thermocouple(TC) interface circuits with cold-junction compensator(CJC) and its broken wires detection was developed. The circuit consists of a CJC device, a instrumentation amplifier(IA), and two resistor and a diode for broken wire detection. The experiment results show that the interface circuit has a good CJC function on the temperature range for $20^{\circ}C$ to $1400^{\circ}C$. At the range the output voltage of the IA was -14V when the TC was broken. At normal operation condition the output voltage of IA was 0V to 10V for the temperature range.

  • PDF

견봉 쇄골 관절 탈구에 사용된 K-강선의 경추부로의 이동 - 증례보고(2예) - (Migration of K-wires from the Acromioclavicular Joint to the Neck - Case Report(2 cases) -)

  • 이우승;김택선;윤정로;김영배;서동훈;권제호
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.196-201
    • /
    • 2006
  • We report two cases of migration of K-wires from the acromioclavicular joint to the neck. A 73-year-old man complained of right shoulder pain for one month and had undergone orthopedic surgery because of acromioclavicular joint dislocation about 27 years earlier. Another 56-year-old man complained of left shoulder pain and neck pain for 5 years and had undergone orthopedic surgery because of acromioclavicular joint dislocation about 25 years earlier. In both cases, we took X-rays to look for the cause of shoulder pain and discovered broken and migrated K-wires in the neck. We removed the K-wires from the trapezius muscle and the paraspinal muscle respectively. K-wire fixation technique is simple and effective but should be followed up with X-rays periodically. In addition, we should warn patients of the possibility of migration of K-wire. And it is desirable for us to avoid using K-wire near major neurovascular structures like the sternoclavicular joint and the clavicle.

Conservation of the Old Hat

  • Im Sung-Kyung;Han Myung-Sook
    • The International Journal of Costume Culture
    • /
    • 제7권2호
    • /
    • pp.151-157
    • /
    • 2004
  • This research is to conservate the old hat and restore its shape and place it on a supportive form in a stable protective container. The hat is a homemade construction, utilizing three different machine made laces, and two cotton net fabrics. The exterior, particularly the top crown piece, as well as the lace along the brim's edge has been generally soiled and discolored. Inside the crown, the cotton net has broken threads, and thread loss in several areas. The paper covering the two wires is very weak, and has discolored the lace in the areas of contact. The plastic buckles of the velvet ribbon have also discolored the areas where there is contact. The wash/bleach bath procedure was very effective. Virtually all of the light brown surface discoloration stains were removed. The darker brown spots, particularly concentrated around the two paper covered wires and assumed to be rust, were $90\%$ removed by the treatment. The brown spots apparently were due to the degradation of the paper covering, and not caused by the wire itself. The buckram foundation lost about $50\%$ of its stiffness, but this was not a major concern due to the fact that this hat should remain it its mount, which has been designed to serve for both storage and exhibition purposes.

  • PDF

OPGW Corrosion Detection Using Nondestructive Test Method

  • Jeong, Jae-Kee;Yoon, Gi-Gab;Kang, Ji-Won;Yang, Hai-Won
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권1호
    • /
    • pp.45-50
    • /
    • 1998
  • This paper deals with some characteristics of a nondestructive eddy current detector to measure OPGW(Composite overhead ground wire with optical fiber) corrosion. This detector is designed to automatically run on OPGW and to continuously inspect the corrosion of the line. The impedance of the eddy current coil changing by any corrosion phenomenon of OPGW is analyzed. Several performances of the detector are described and experimental procedures and test results are also given. As a result, it is shown that the implemented detector can be measured some quantitative data for crack, broken wires or severe deteriorations in OPGW. This nondestructive test method would be applied to improve the reliability and efficiency of transmission line in service.

  • PDF

승객용 엘리베이터 와이어로프의 유효수명 및 교체시기 평가 (Evaluation of Replace period and Useful lifetime of the wire ropes for the Passenger's Elevator)

  • 손두익;박재석;오환섭
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.35-38
    • /
    • 2003
  • The wire rope, one of the component of the elevator, is extremely important for the sage operation of the elevator. That is why the wire rope is replaced at a specific interval regradless of the operating conditions or the degree of damage to prevent the breakage of the wire rope. This is the waste of resources, causing economic and environmental loss. This paper has surveyed and analyzed and analyzed the status of replacing wire-rope by buildings that use elevators, in order to compare the replacement cycles of the wire rope under each operating conditions.

국보 제193호 봉수형유리병 금사의 특성과 제작기법 연구 (A Study on the Characteristic and Manufacture Technique for the Gold wire of Phoenix-Shaped Glass Ewer by National Treasure No. 193)

  • 황현성;윤은영
    • 보존과학회지
    • /
    • 제31권1호
    • /
    • pp.21-27
    • /
    • 2015
  • 국보 제193호 봉수형유리병은 5세기에 조성된 것으로 알려진 황남대총 남분의 수많은 부장품들 사이에 독특한 형태의 녹색 유리 편들로 심하게 파손된 채 출토되었다. 1984년 국립중앙박물관 보존과학실에서 본격적으로 보존처리를 실시하여 박물관에서 오랜 기간 동안 전시되어 왔지만, 30년이라는 세월로 인해 기존에 사용한 접착제는 심하게 열화가 되어 매우 불안전한 상태가 되었으며 특히 복원제로 사용한 에폭시 수지가 빛과 열에 의해 심하게 황변이 되어 더 이상 유물의 안정한 전시와 효과적인 전시가 이루어질 수 없어 이번에 재 보존처리를 하게 되었다. 이번 연구에서는 그동안 연구가 전혀 진행되지 않았던 세 조각으로 파손된 봉수형유리병 손잡이 부분을 금사로 정성스럽게 감아 수리에 사용한 3 조각의 금사를 중점적으로 살펴보았다. 금사에 대한 분석방법으로는 SEM-EDS와 Stereo Microscope를 사용하여 비파괴적으로 분석하였다. 먼저, SEM-EDS 분석 결과, Au 91.9wt%-Au 92.8wt% 와 Ag 5.9wt.%-Ag 6.5wt.%으로 Au 과 Ag의 합금인 금제로 밝혀졌다. 다음으로 광학현미경으로 금사의 제작기법을 관찰한 결과, 일반적으로 금사는 덩이 금을 두드려서 만들거나 구멍에 밀어 넣어 뽑아내는 인발 가공 또는 금판을 꼬아서 제작하는 방법으로 제작하는데 봉수형유리병 손잡이에서 분리한 금사는 표면에서 꼬임 흔적은 전혀 나타나지 않고 단지 길이 방향으로 미세한 줄무늬가 관찰되고 단면이 모두 채워진 상태인 것으로 보아 인발 가공하여 만든 것을 사용하여 보수한 것으로 생각된다. 이러한 분석 결과는 그동안 금사에 대한 연구가 대부분 금제품 유물의 구성품으로만 인식된 채 별도의 유물로 주목받지 못해 금사에 대한 제작기법에 대한 체계적인 연구가 매우 미흡한 편이기 때문으로 장차 금사에 대한 추가적인 연구가 진행된다면 이번 봉수형유리병 손잡이 고정에 사용된 금사 분석 결과가 기존 신라시대 금제 유물의 금사와의 상호 연관성을 밝혀내는데 좋은 자료가 될 것으로 생각된다.