• 제목/요약/키워드: brightness contrast

검색결과 287건 처리시간 0.026초

플루오레신나트륨의 농도 범위 분석 (Analysis for Concentration Range of Fluorescein Sodium)

  • 이다애;김용재;윤기철;김광기
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권2호
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

Holographic phase gratings in back- and frontlights for LCD's

  • Bastiaansen, C.W.M.;Heesch, C. van;Broer, D.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.421-421
    • /
    • 2006
  • The light and energy-efficiency of classical liquid crystal displays is notoriously poor due to the use of absorption-based linear polarisers and colour filters. For instance, the light efficiency of PVAL polarisers is typically between 40 and 45 % and the colour filters have a typical efficiency below 35 % which results in a total light and energy-efficiency of the display below 10 %. In the past, a variety of polarizers were developed with an enhanced efficiency in generating linearly polarized light. Typically, these polarizers are based on the polarisationselective reflection, scattering or refraction of light i.e. one polarisation direction of light is directly transmitted to the LCD/viewer and the other polarization direction of light is depolarised and recycled which results in a typical efficiency for generating linearly polarized light of 70-85 %. Also, special colour filters have been proposed based on chiral-nematic reactive mesogens which increase the efficiency of generating colour. Despite the enormous progress in this field, a need persists for improved methods for generating polarized light and colour based on low cost optical components with a high efficiency. Here, the use of holographic phase gratings is reported for the generation of polarized light and colour. The phase grating are recorded in a photopolymer which is coated onto a backor frontlight for LCDs. Typically the recording is performed in the transmisson mode or in the waveguiding mode and slanted phase gratings are generated with their refractive index modulation at an angle between 20o and 45o with the normal of the substrate. It is shown that phase gratings with a high refractive index modulation and a high efficiency can be generated by a proper selection of the photopolymer and illumination conditions. These phase gratings coupleout linearly polarized light with a high contrast (> 100) and the light is directed directly to the LCD/viewer without the need for redirection foils. Dependent on the type of phase grating, the different colours are coupled-out at a slightly different angle which potentially increases the efficiency of classical colour filters. Moreover, the phase gratings are completely transparent in direct view which opens the possibility to use them in frontlights for LCDs. Holographic polarization gratings posses a periodic pattern in the polarization state of light (and not in the intensity of light). A periodic pattern in the polarization direction of linearly polarized light is obtained upon interference of two circularly polarized laser beams. In the second part of the lecture, it is shown that these periodic polarization patterns can be recorded in a linear photo-polymerizable polymer (LPP) and that such an alignment layer induces a period rotation in the director of (reactive and non-reactive) liquid crystals. By a proper design, optical components can be produced with only first order diffraction and with a very high efficiency (>0.98). It is shown that these diffraction gratings are potentially useful in projection displays with a high brightness and energy efficiency

  • PDF

근광장 측정에서 방사선 사진술의 정확도 (The Accuracy of the Radiographic Method in Root Canal Length Measurement)

  • 조은영;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

세종 합강리 유적 출토 고대 유리구슬의 특성 연구 (A Characteristics on the Ancient Glass Beads Excavated from the Site of Hapgang-ri in Sejong, Korea)

  • 김은아;김규호;강지원;윤천수
    • 보존과학회지
    • /
    • 제36권5호
    • /
    • pp.405-420
    • /
    • 2020
  • 본 연구는 세종 합강리 유적을 중심으로 발굴 유적과 유물을 조사한 고고학적 접근과 주구토광묘 15호에서 유일하게 출토된 유리구슬의 표면, 단면, 조성 특성을 분석한 보존과학적 접근으로 구분하여 융합적 연구를 시도하였다. 묘의 형태와 출토유물을 통한 고고학적 연구에서 합강리 유적은 주구토광묘의 등장 시기가 2세기 후엽부터이고 유리구슬이 출토된 주구토광묘 15호 편년은 2세기 후엽~3세기 초엽으로 추정할 수 있다. 유리구슬 완형은 형태, 색상 및 제작기법을 파악하고 유리구슬편 16점은 단면관찰과 화학 조성을 분석한 결과에서 청색 계통은 감청색과 자색으로, 적색 계통은 적갈색으로 구분되며 세부 색상에서 청색 계통은 광택과 명도에 따라 다양하게 분포하나 적색 계통은 균일도가 높게 나타난다. 제작기법은 표면의 줄무늬와 기포배열에서 늘인기법으로 확인되며 구슬 양 끝부분에서 열처리나 연마 흔적도 관찰된다. 유리구슬 편 16점의 화학 조성은 포타쉬유리군 3점과 소다유리군 13점으로 분류된다. 소다유리군 13점에 대한 안정제 특성은 청색과 적색 계통에 따라 구분된다. 이중에서 적색 계통의 안정제 특성은 지금까지 다른 지역에서 확인된 적갈색 유리구슬과 다른 조성으로 구분되는 점이 특이하다. 착색제는 청색 계통이 MnO 성분을 함유한 코발트(Co), 그리고 적색 계통은 구리(Cu)와 철(Fe)이다.

TV 화질에 대한 감성평가척도 개발 (Development of Emotion Assessment Scale in Evaluation of Television Picture Quality)

  • 장은혜;최상섭;이경화;손진훈
    • 감성과학
    • /
    • 제12권1호
    • /
    • pp.121-128
    • /
    • 2009
  • 본 연구의 목적은 TV 화질에 대한 사용자들의 심리적 특성을 평가하기 위한 화질평가척도를 개발하고, TV 화질의 심리 특성과 물리적 특성의 관계를 확인하는 것이다. TV 화질과 관련된 형용사 152개 중 집단설문(남녀 대학생 80명)을 통하여 TV 화질을 잘 표현하는 형용사로 19개의 형용사를 선정하였다. 선정된 형용사는 다음과 같다; '깔끔하다-지저분하다', '깨끗하다-더럽다', '산뜻하다-침울하다', '편안하다-긴장된다', '매끄럽다-거칠다', '밝다-어둡다', '화려하다-수수하다', '변화스럽다-단조롭다', '자연스럽다', '감각적이다', '만족스럽다'. 126명의 남녀 대학생을 대상으로 이들 형용사의 유사성 평정을 실시하고, 유사성 점수에 대하여 요인분석(주성분분석, oblique 회전)을 실시한 결과, '깔끔함' 차원과 '화려함' 차원으로 분류되었다. 그리고 31명의 남녀 대학생을 대상으로 TV 화질에 대한 감성과 물리적 특성과의 관계를 확인하였다. 그 결과 TV 화질에 대한 감성 형용사들은 밝기, 명암, 색농도와 색상의 변화에는 민감하였으나, 선명도의 변화에는 민감하지 않은 것으로 나타났다.

  • PDF

흉부 엑스레이 영상에서 배경 제거 및 관심영역 분할 기법 (Background Removal and ROI Segmentation Algorithms for Chest X-ray Images)

  • 박진우;송병철
    • 전자공학회논문지
    • /
    • 제52권11호
    • /
    • pp.105-114
    • /
    • 2015
  • 본 논문은 흉부 엑스레이 영상에서 배경 제거 및 관심 영역을 분할하는 기법을 제안한다. 일반적으로 화질 개선 기법을 적용할 때 영상의 밝기 정보나 주파수 정보를 이용하여 영상 선명도와 대비를 개선하는 방법을 사용한다. 이러한 기법을 엑스레이 영상 전체에 적용하는 경우 배경과 같은 영상의 불필요한 정보 때문에 좋은 성능을 얻기 어렵다. 그래서 본 논문은 사용자가 원하는 영역에만 화질 개선 기법을 적용할 수 있도록 배경 제거 및 관심 영역 (ROI)을 분할하는 방법을 제안한다. 배경 제거를 위해 먼저 원본 영상의 히스토그램 분포를 분석하고 문턱치 처리로 몸체와 배경을 일차적으로 분리한다. 다음으로 유도 필터 (guided filter)를 이용하여 몸체 경계 혹은 배경 경계를 보정한다. 관심 영역 분할을 위해서는 먼저 폐의 위치 정보를 이용하여 폐의 주 밝기 값을 찾는다. 이를 이용하여 문턱치 처리를 한 후 번호 매김과 상기 배경 정보를 이용하여 분류 이외의 것을 제거한다. 마지막으로 폐만 검출된 이진영상을 통해 경계 상자 영역을 생성한다. 모의실험을 통해 제안하는 기법의 우수성을 검증하였다.

Classification of Diabetic Retinopathy using Mask R-CNN and Random Forest Method

  • Jung, Younghoon;Kim, Daewon
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권12호
    • /
    • pp.29-40
    • /
    • 2022
  • 본 논문에서는 딥러닝 기법의 하나인 Mask R-CNN과 랜덤포레스트 분류기를 이용해 당뇨병성 망막병증의 병리학적인 특징을 검출하고 분석하여 자동 진단하는 시스템을 연구하였다. 당뇨병성 망막병증은 특수장비로 촬영한 안저영상을 통해 진단할 수 있는데 밝기, 색조 및 명암은 장치에 따라 다를 수 있으며 안과 전문의의 의료적 판단을 도울 인공지능을 이용한 자동진단 시스템 연구와 개발이 가능하다. 이 시스템은 미세혈관류와 망막출혈을 Mask R-CNN 기법으로 검출하고, 후처리 과정을 거쳐 랜덤포레스트 분류기를 이용하여 안구의 정상과 비정상 상태를 진단한다. Mask R-CNN 알고리즘의 검출 성능 향상을 위해 이미지 증강 작업을 실시하여 학습을 진행하였으며 검출 정확도 측정을 위한 평가지표로는 다이스 유사계수와 Mean Accuracy를 사용하였다. 비교군으로는 Faster R-CNN 기법을 사용하였고 본 연구를 통한 검출 성능은 평균 90%의 다이스 계수를 통한 정확도를 나타내었으며 Mean Accuracy의 경우 91% 정확도의 검출 성능을 보였다. 검출된 병리증상을 토대로 랜덤포레스트 분류기를 학습하여 당뇨병성 망막 병증을 진단한 경우 99%의 정확도를 보였다.