• Title/Summary/Keyword: breath sound

Search Result 21, Processing Time 0.022 seconds

A Study on Realistic Sound Reproduction for UHDTV (UHDTV를 위한 실감 오디오 재현 기술)

  • Jang, Daeyoung;Seo, Jeongil;Lee, Yong Ju;Yoo, Jae-Hyoun;Park, Taejin;Lee, Taejin
    • Journal of Broadcast Engineering
    • /
    • v.20 no.1
    • /
    • pp.68-81
    • /
    • 2015
  • Owing to the latest development of component and media processing technologies, UHDTV as a successor of the HDTV is expected that this will be coming soon realization. Accordingly, an audio technology that provides a 5.1-channel surround sound in home should be contemplating on what services should be provided with the advent of UHDTV era. In fact, however, the market of 5.1-channel audio is struggling, due to the difficulty of installation and maintenance of the multi speakers in a home. Meanwhile, the movie sound market for a long time been used in 5.1 and 7.1-channel sound formats, have changed as Dolby ATMOS, IOSONO, AURO3D etc. are launched one after another with the introduction of hybrid audio technologies that include the ceiling and object-based sounds. This very object-based audio technology is assured to be introduced in the home theater and broadcast audio market, and this change in audio technology is expected to be a breath of pioneering technological advances and market growth from the channel-based audio market that lacks flexibility. In this paper, we will investigate a suitable realistic audio solution for UHDTV, and introduce hybrid audio technologies, which is expected to be an audio technology for UHDTV, and we will describe the hybrid audio content format and reproduction methods in a home and consider the future prospects of realistic audio.

Plan for the Development of a Standardized Dummy for Persons in Need of Rescue in a Confined Space (밀폐공간 구조 요구자를 위한 더미 표준화 개발 방안)

  • Choi, Seo-Yeon;Rie, Dong-Ho;Kim, Hyung-Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.99-105
    • /
    • 2016
  • This study was conducted to develop a dummy in an environment similar to the human body, to prepare a standard for evaluation and to present the process of the production in order to evaluate the performance of the robot that can detect the persons needing rescue in a confined space, who are difficult for fire-fighting officials to rescue in case of fire and disaster. As a result, a standard for evaluation was developed and standardized into four parts 'Normal,' 'Risk Stage 1,' 'Risk Stage 2' and 'Risk Stage 3'based on the number of breath cycles, carbon dioxide concentration, core temperature and criteria for hearing to recognize the voice. In addition, in order to produce a dummy, fever, breathing capacity and voice output function were compared and analyzed. This study has significance that it built up basic data of the method of producing the actual dummy, by presenting characteristics and controlling methods using the waterproof insulation heating coil for the function, solenoid valve for the consecutive output of breathing capacity and USB program sound board for voice output.

A Case of Superior Vena Cava Syndrome Caused by Klebsiella Pneumonia (폐렴간균 폐렴에 의해 유발된 상대정맥 증후군 1예)

  • Kim, Ju-Young;Lim, Chae-Man;Kim, Seon-Hee;Chu, Yun-Ho;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.58-62
    • /
    • 1994
  • Superior vena cava(SVC) syndrome is mostly related to a malignant process, but many different benign causes have also been described. We report a case of SVC syndrome caused by Klebsiella pneumonia diagnosed by sputum culture and serial chest X-ray changes. A 27-year-old man had been in stable health until three days before admission, when he complained of pleuritic chest pain, facial flushing, and shortness of breath. Examination of the head and neck disclosed edema of face and both arms, and jugular venous distention to the angle of the jaw. The chest auscultation revealed decreased breath sound without crack1e on right upper lung field. The chest roentgenogram showed homogenous air space consolidation on right upper lobe, asociated with downward displacement of minor fissure and contralateral displacement of trachea, but air bronchogram was not seen. We began antibiotic therapy under impression of pneumonia after available culture was taken from blood and sputum. SVC scintigraphy showed stasis of drain of right brachiocephalic vein at the proximal portion with reflux into the right internal jugular vein and faintly visible SVC via the collaterals. Sputum culture revealed Klebsiella pneumoniae. Antibiotic therapy resulted in a cure of infection and disappearance of facial swelling. Follow-up SVC scintigraphy after 20 days showed normal finding. We first report a case of SVC syndrome caused by klebsiella pneunonia.

  • PDF

Nasalance Changes in Nasal Disease Patients after Nasal Cavity Operation (비질환 환자에서 비강수술 후 비음도 변화)

  • Lee, Jae-Hoon;Kim, Joo-Yeon;Lee, Kang-Dae;Kim, Seung-Tae;No, Yong-Hyeon;Kim, Kyung-A;Seo, Yun-Suk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.21 no.2
    • /
    • pp.128-132
    • /
    • 2010
  • Background and Objectives : This study was designed to examine the effect of nasal cavity surgery on voice in terms of nasalance by using subjective test, Visual analogue scale (VAS) and Nasometer and compare the pre op and post op results among patiets with nasal cavity disease. Materials and Method : From April 2009 to November 2009, data of thirty one patients who underwent nasal cavity surgery were prospectively evaluated. 24 males and 7 females with age range between 12 years to 80 years old (average 34 years old) were chosen. VAS was questioned to patients group before, after 1 week, after 1 month, and after 3 months from the surgery. Nasometer, was also conducted. Results: After the surgery symptoms like nasal obstruction, mouth breath, snoring, and sleep apnea were all improved. Improvements for nasal obstruction and mouth breath were observed statistically in post operative day (POD) 1 month and POD 3 months. Also snoring was improved statistically in POD 1 month. Objective nasalance test showed increases in a single and double vowel for POD 3 months. Only /je/ sound statistically-significant increased in all post operative periods. Nasalance increase were observed in other test results. Conclusion : All the symptoms are improved after nasal cavity surgery. Also there are some nasalance changes during whole period of study and return to the pre operative state in POD 3 months. Therefore, patients must be warned and understood about nasalance changes, and surgeons need to aware of various facts, which can affect voice changes before the surgery.

  • PDF

Literature for YangsaengKigong (한국전통사상으로 살펴본 양생기공에 대한 고찰)

  • Jeon, Chun-San;Han, Chang-Hyun;Park, Soo-Jin;Lee, Sang-Nam;Kwon, Young-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.740-745
    • /
    • 2008
  • Although the demand on 'Ki' training because of the increased interest in health, there has not been an established theory and system in 'Ki' training from the perspective of oriental medicine. Therefore, many training associations are in operation without sound basis. The general use of the terminology 'Kigong' is the influence of China. As it was distributed to the general public through the translation and introduction of Chinese Kigong theory, the genuine Korean YangsaengKigong was not emphasized but it was included in or considered as the second-class to the Chinese Kigong. The purpose of the study was to establish and review YangsaengKigong based on our traditional ideologies. Korean Yangsaengkigong can be defined as the training method nurturing mind, energy, body based on the Sambeob training method such as Pause of thinking, Modulation of breath and Prohibition of sensibility with the goal of Yangsaengkigong, good health and long life and the maximum service for the benefit of humanity. Although this study can identify the differecnes between Korean Yangseangkigong and Chinese kigong through Korean traditional ideology, we could not develop this study to the necessity of ideological background of medical Kigong and concrete methodology of Yangsaengkigong and our traditional ideology because of scarce literature on Korea and Korean traditional ideologies. For the purspose of the study, we need cooperation between Studies of Korea, Studies of National History, and Oriental Medicine.

Cardiorespiratory Responses of Qi-training: A Pilot Study

  • Lee, Myeong-Soo;Kim, Soo-Keun;Kim, Hye-Jung;Moon, Sun-Rock
    • Advances in Traditional Medicine
    • /
    • v.4 no.1
    • /
    • pp.18-21
    • /
    • 2004
  • Six volunteers (mean $age=25.7{\pm}1.7$, $height=173{\pm}1.9$ and $weight=63.4{\pm}2.3{\;}kg$) participated in a graded exercise test and one hour of basic form of ChunDoSunBup (CDSB) Qi-training to investigate the cardiorespiratory responses and exercise intensity of Qi-training, a Korean traditional psychosomatic training. In the maximal exercise, the trainee showed $96.2{\pm}8.89{\;}l/min$ in ventilation (VE), $46.0{\pm}4.4$ in breath frequency (BF), $1.31{\pm}0.05$ in respiratory exchange ratio (RER), $180.7{\pm}3.0$ in heart rate (HR), and $2.6{\pm}1.1{\;}l/min$ or $40.7{\pm}2.3{\;}ml/kg/ml$ in oxygen consumption $(VO_2)$. Qi-training induced significant changes in BF, RER, HR, and $VO_2$. The exercise intensity of Qi-training were 42.3%, 46.9% and 38.7% of $HR_{max}$ during the sound exercise, slow motion (haeng-gong) and meditation respectively and the average was 46.2% of $HR_{max}$. We conclude that Qi-training is an aerobic exercise of a light (mild) intensity exercise, and it leads to decrease the metabolic rate in the trainee by breathing efficiently and relaxing them. In addition, Qi-training may affect cardiorespiratory function of BF, RER, HR and $VO_{2max}$ in trainees.

Comparison of Sleep Pattern, Factors of Sleep Disturbance and Sleep Enhancement Behaviors between Sleep Disturbance and Non-Sleep Disturbance Aged Patients (수면장애 노인 환자와 일반 노인 환자의 수면양상, 수면장애요인 및 수면증진행위)

  • Han, Suk-Jung;Lee, Eun-Young;Kim, Kyung-Mi;Park, Sun-Nam
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.14 no.1
    • /
    • pp.62-71
    • /
    • 2007
  • Purpose: This study was done to compare sleep patterns, factors of sleep disturbance and sleep enhancement behaviors between sleep disturbance and non-sleep disturbance elderly patients. Method: The participants were 117 patients over 65 years old who were hospitalized at 5 general hospitals in Seoul. There were 83 patients in the good sleeper group and 34 in the poor sleeper group. The survey questionnaires included questions on general characteristics, sleep patterns, sleep disturbing factors, and sleep enhancement behaviors of the patients. Results: For sleep patterns and environmental factors of sleep disturbance, the poor sleepers was significantly higher than that of the good sleepers. Significant differences between good sleepers and poor sleepers were also found on the following variables: Environmental factors of sleep disturbance -'Sound of other patient's or care-giver's', 'Discomfort of bed, linen, pillow and patient's gown', 'Light in the room', 'Emergency situations', 'Temperature of patients rooms too hot or too cold'. The significant physical factor of sleep disturbance was 'Hard to breath even without moving' and for sleep enhancement behaviors: 'Use of ear plugs or eye covers' Conclusion: Consequently it is necessary to develop positive and differentiated programs for sleep enhancement for the inactive and poor sleeper among the elderly patients.

  • PDF

A study on the Characteristics of the Adult Men Sound as by Sasang Constitution Analysed with PSSC-2004 (사상체질음성분석기(四象體質音聲分析機)(PSSC-2004)를 통한 성인남성(成人男性)의 체질별(體質別) 음향특성(音響特性))

  • Kim, Dong-Jun;Jung, Woon-Ki;Choi, Jae-Wan;Kim, Dal-Rae;Jeon, Jong-Weon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.17 no.1
    • /
    • pp.67-83
    • /
    • 2005
  • 1. Objectives The purpose of this study lies on the objectification of the Sasang Constitutional diagnosis. This study was analyzing the constitutional characteristic of adult men voices by PSSC-2004. 2. Methods The study was conducted on the subjects inputted /a/ 2.5-3 sec of 231 adult men voices to PSSC-2004. The statistical analyses are applied to three groups: total group, under 55 year-old group, over 55 year-old group. The group of total 231 was composed with 5 Taeyangins, 32 Soyangins, 102 Taeumins and 92 Soeumins. The under 55 years old group was composed with 4 Taeyangins, 23 Soyangins, 83 Taeumins and 77 Soeumins. The over 55 year-old group was composed with 1 Taeyangin, 9 Soyangins, 19 Taeumins and 15 Soeumins. 3. Results 1) In total group, the Soeumin's mean value of center pitch(4)$(1,000{\sim}2,000Hz)$ was significantly high compared with the others (P=0.034). 2) In total group, the Soeumin's group 3 APQ was significantly low compared with the others (P=0.042). 3) In under 55 year-old group, the Soeumin's center value of center pitch 4$(1,000{\sim}2,000Hz)$ was significantly high compared with the others (P=0.025) 4) In over 55 year-old group, no statistical significance was found between the Taeyangin, Soyangin, Taeumin and Soeumin. 4. Conclusions In under 55 year-old group, Soeumin's voice showed high pitched sound (clearness) at the low frequency (1000-2000Hz). In over 55 year-old group, there is no significant differences. This fits in with that 'Soeumin's voice is 'Yu-tone' born by 'Shang-tone', very short and high.' 'Yu-tone' corresponds to 'Ra' and witch is highest among Gong, Shang, Gao, Chi and Yu. This is related with the appearance that the Soeumin's voice is weak, thin and high tone. Therefore it is supposed that Soeumin adult men's voices are thick, and there are vibrations of the ending. It is accepted one of the Soeumin's characters like as a mild tremor of limbs and deep breath caused by Soeumin's Qi-deficiency. This outcome accords with the theory that Soeumin's Qi is less than the Other constitutions.

  • PDF

Detection of Tracheal Sounds using PVDF Film and Algorithm Establishment for Sleep Apnea Determination (PVDF 필름을 이용한 기관음 검출 및 수면무호흡 판정 알고리즘 수립)

  • Jae-Joong Im;Xiong Li;Soo-Min Chae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.119-129
    • /
    • 2023
  • Sleep apnea causes various secondary disease such as hypertension, stroke, myocardial infarction, depression and cognitive impairment. Early detection and continuous management of sleep apnea are urgently needed since it causes cardio-cerebrovascular diseases. In this study, wearable device for monitoring respiration during sleep using PVDF film was developed to detect vibration through trachea caused by breathing, which determines normal breathing and sleep apnea. Variables such as respiration rate and apnea were extracted based on the detected breathing sound data, and a noise reduction algorithm was established to minimize the effect even when there is a noise signal. In addition, it was confirmed that irregular breathing patterns can be analyzed by establishing a moving threshold algorithm. The results show that the accuracy of the respiratory rate from the developed device was 98.7% comparing with the polysomnogrphy result. Accuracy of detection for sleep apnea event was 92.6% and that of the sleep apnea duration was 94.0%. The results of this study will be of great help to the management of sleep disorders and confirmation of treatment by commercialization of wearable devices that can monitor sleep information easily and accurately at home during daily life and confirm the progress of treatment.

Validity of Nursing Diagnoses Related to Difficulty in Respiratory Function (호흡기능장애와 관련된 간호진단의 타당도 조사)

  • 김조자;이원희;유지수;허혜경;김창희;홍성경
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.4
    • /
    • pp.569-584
    • /
    • 1993
  • This study was done to verify validity of nursing diagnoses related to difficulty in respiratory function. First, content validity was examined by an expert group considering the etiology and the signs / symptoms of three nursing diagnoses - ineffective airway clearance, ineffective breathing pattern, impaired gas exchange. Second, clinical validity was examined by comparing the frequencies of the etiologies and signs / symptoms of the three nursing diagnoses in clinical case studies with the results of the content validity. This study was a descriptive study. The sample consisted of 23 experts (professors, head nurses and clinical instructors) who had had a variety of experiences using nursing diagnoses in clinical practice, and 102 case reports done by senior student nurses of the college of nursing of Y-university. These reports were part of their clinical practice in the ICU. The instrument used for this study was a checklist for etiologies and signs and symptoms based on the literature, Doenges and Moorhouse (1988), Kim, McFarland, McLane (1991), Lee Won Hee et al. (1987), Kim Cho Ja et at. (1988). The data was collected over four month period from May 1992 to Aug. 1992. Data were analyzed using frequencies done with the SPSS / PC+ package. The results of this study are summarized as follows : 1. General Characteristics of the Expert Group A bachelor degree was held by 43.5% and a master or doctoral degree by 56.5% of the expert group. The average age of the expert group was 35.3 years. Their average clinical experience was 9.3 years and their average experience in clinical practice was 5.9 years. The general characteristics of the patients showed that there were more women than men, that the age range was from 1 to over 80. Most of their medical diagnoses were diagnoses related to the respiratory. system, circulation or neurologic system, and 50% or more of them had a ventilator with intubation or a tracheostomy. The number of cases for each nursing diagnoses was : · Ineffective airway clearance, 92 cases. · Ineffective breathing pattern, 18 cases. · Impaired gas exchange, 22 cases. 2. The opinion of the expert group as to the classification of the etiology, and signs and symptoms of the three nursing diagnoses was as follows : · In 31.8% of the cases the classification of etiology was clear. · In 22.7%, the classification of signs and symptoms was clear. · In 17.4%, the classification of nursing interventions was clear. 3. In the expert group 80% or mere agreed to ‘dysp-nea’as a common sign and symptom of the three nursing diagnoses. The distinguishing signs and symptoms of (Ineffective airway clearance) were ‘sputum’, ‘cough’, ‘abnormal respiratory sounds : rales’. The distinguishing sings and symptoms of (Ineffective breathing pattern) were ‘tachypnea’, ‘use of accessory muscle of respiration’, ‘orthopnea’ and for (Impaired gas exchange) it was ‘abnormal arterial blood gas’, 4. The distribution of etiology, and signs and symptoms of the three nursing diagnoses was as follows : · There was a high frequency of ‘increased secretion from the bronchus and trachea’ in both the expert group and the case reports as the etiology of ineffective airway clearance. · For the etiologies for ineffective breathing pat-tern, ‘rain’, ‘anxiety’, ‘fear’, ‘obstructions of the tract, ca and bronchus’ had a high ratio in the ex-pert group and ‘decreased expansion of lung’ in the case reports. · For the etiologies for impaired gas exchanges, ‘altered oxygen -carrying capacity of the blood’ and ‘excess accumulation of interstitial fluid in lung’ had a high ratio in the expert group and ‘altered oxygen supply’ in the case reports. · For signs and symptoms for ineffective airway clearance, ‘dyspnea’, ‘altered amount and character of sputum’ were included by 100% of the expert group. ‘Abnormal respiratory. sound(rate, rhonchi)’ were included by a high ratio of the expert group. · For the signs and symptoms for ineffective breathing pattern. ‘dyspnea’, ‘shortness of breath’ were included by 100% of the expert group. In the case reports, ‘dyspnea’ and ‘tachypnea’ were reported as signs and symptoms. · For the sign and symptoms for impaired gas exchange, ‘hypoxia’ and ‘cyanosis’ had a high ratio in the expert group. In the case report, ‘hypercapnia’, ‘hypoxia’ and ‘inability to remove secretions’ were reported as signs and symptoms. In summary, the similarity of the etiologies and signs and symptoms of the three nursing diagnoses related to difficulty in respiratory function makes it difficult to distinguish among them But the clinical validity of three nursing diagnoses was established through this study, and at last one sign and symp-tom was defined for each diagnosis.

  • PDF