• Title/Summary/Keyword: breast ultrasound

Search Result 144, Processing Time 0.027 seconds

Contrast-Enhanced Spectral Mammography Versus Ultrasonography: Diagnostic Performance in Symptomatic Patients with Dense Breasts

  • Zhongfei Lu;Cuijuan Hao;Yan Pan;Ning Mao;Xin Wang;Xundi Yin
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.442-449
    • /
    • 2020
  • Objective: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) versus ultrasonography (US) in symptomatic patients with dense breasts, while using histology as the gold standard. Materials and Methods: After obtaining approval from the local ethics board, this prospective study collected data from patients with symptomatic breasts who underwent CESM and US examinations from May 1, 2017 to September 30, 2017. We then selected those with dense breasts and pathological results as our sample population. Both CESM and US results were classified by a radiologist through the Breast Imaging Reporting and Data System, and the results were compared with their corresponding histological results. The chi-square test was conducted to compare the diagnostic performance of CESM and US, and the receiver operating characteristic curves for the two imaging modalities were obtained. Results: A total of 131 lesions from 115 patients with dense breasts were included in this study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 93.8%, 88.1%, 88.2%, 93.7%, and 90.8% for CESM, and 90.6%, 82.1%, 82.9%, 90.2%, and 86.3% for US, respectively. The p values for sensitivity, specificity, PPV, NPV, and accuracy were 0.687, 0.388, 0.370, 0.702, and 0.238, respectively. The area under the curve of CESM (0.917) was comparable with that of US (0.884); however, the differences between CESM and US were not statistically significant (p = 0.225). Eight false-positive cases and 4 false-negative cases for breast cancer were found in CESM, while 12 false-positive cases and 6 false-negative cases were found in US. Conclusion: The diagnostic performances of CESM and US are comparable in symptomatic women with dense breasts; however, the routine use of additional US imaging is questionable for lesions that can be detected by CESM.

Usefulness of Color-overlay Pattern of Breast Elastic Ultrasonography (유방 탄성초음파의 Color overlay pattern에 대한 유용성)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.401-406
    • /
    • 2017
  • Breast cancer rates are increasing every year, biopsy for diagnosing breast cancer is increasing as well. Biopsy also invasive test, have bad side effects from patients anxiety, infection, bleeding. In this study, Conduct a survey of 69 patients who brest lesion patient, both B-mode ultrasound and elastography exam and B-mode ultrasound was classified according to the BI-RADS category, and the elastography exam was classified according to the Color overlay pattern that the value of the kPa expressed in relation to the propagation velocity of Transverse waves. The optimal cut off value of the highest sensitivity and specificity was 54.70 kPa. In the color overlay pattern, Dark Blue 42 people, Light blue ~ Red 27 people classified results and BI-RADS classification results, benign 40 people and malignant 29 people classified results showed similar results. Therefore, It is judged that the color overlay pattern is positive when classified into Dark Blue, and malignant when classified into Light blue ~ Red. In conclusion, breast elastography is expected to play a innovative role in reducing the number of breast cancer examinations and classify between benign and malignant tumor.

A simple calculation for the preoperative estimation of transverse rectus abdominis myocutaneous free flap volume in 2-stage breast reconstruction using a tissue expander

  • Kono, Hikaru;Ishii, Naohiro;Takayama, Masayoshi;Takemaru, Masashi;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.333-339
    • /
    • 2018
  • Background Flap volume is an important factor for obtaining satisfactory symmetry in breast reconstruction with a transverse rectus abdominis myocutaneous (TRAM) free flap. We aimed to develop an easy and simple method to estimate flap volume. Methods We performed a preoperative estimation of the TRAM flap volume in five patients with breast cancer who underwent 2-stage breast reconstruction following an immediate tissue expander operation after a simple mastectomy. We measured the height and width of each flap zone using a ruler and measured the tissue thickness by ultrasound. The volume of each zone, approximated as a triangular or square prism, was then calculated. The zone volumes were summed to obtain the total calculated volume of the TRAM flap. We then determined the width of zone II, so that the calculated flap volume was equal to the required flap volume ($1.2{\times}1.05{\times}$the weight of the resected mastectomy tissue). The TRAM flap was transferred vertically so that zone III was located on the upper side, and zone II was trimmed in the sitting position after vascular anastomosis. We compared the estimated flap width of zone II (=X) with the actual flap width of zone II. Results X was similar to the actual measured width. Accurate volume replacement with the TRAM flap resulted in good symmetry in all cases. Conclusions The volume of a free TRAM flap can be straightforwardly estimated preoperatively using the method presented here, with ultrasound, ruler, and simple calculations, and this technique may help reduced the time required for precise flap tailoring.

Satisfaction with the Effect of Local Dynamical Micro-massage Therapy on the Pain and Discomfort after Breast Reconstruction Surgery

  • Ahn, Kwang Hyeon;Lee, Sun Jae;Park, Eun Soo;Park, Yu Gil
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.39-43
    • /
    • 2020
  • Background and Objectives Breast reconstruction has the advantage of reducing the loss of the body image of patients after mastectomy surgery, and also improving the quality of the social and sexual life of breast cancer patients. However, in surprising and unfortunate number of patients, acute postoperative pain persists beyond the normal course of postsurgical recovery. We set out to investigate the effect of local dynamical micro-massage (LDM) treatment for achieving pain relief and reducing other postoperative complications. Materials and Methods We performed a retrospective analysis on 58 patients who underwent LDM treatment for postoperative pain management at Soonchunhyang University Bucheon Hospital between February 2017 and June 2019. Those patients who complained of persistent postoperative pain, which was uncontrollable with medication, were treated with LDM. The degree of pain and discomfort with contracture were recorded using numerical rating scale (NRS) scoring system with numbers from 0 to 10 ('none' to 'worst'). Results The median NRS score of pain was reduced by 62.3% from the start to the end of LDM treatment (p<0.001). Further, the NRS score of discomfort with contracture was reduced 66.0% (p<0.001). There was no complication related to the LDM treatment. Conclusion Dual-frequency ultrasound LDM can be an effective therapeutic option for persisting pain after breast reconstruction surgery. It was also effective in improvement of discomfort with contracture and erythema of the surgical wound.

Analysis of Risk Factors Affecting Breast Cancer Incidence : Breast Ultrasonography (유방암 발생에 영향을 미치는 위험인자 분석: 유방초음파 검진자 대상으로)

  • An, Hyun;Yang, Sung-Hee;Im, In-Chul;Lee, Jin-soo
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.289-295
    • /
    • 2017
  • In general, a number of studies have been conducted on factors affecting breast cancer development, but systematic investigations of risk factors are rare. The purpose of this study was to investigate the factors involved in breast cancer screening before breast ultrasound diagnosis and the risk factors associated with breast cancer screening by ultrasound. Self-administered questionnaire was performed on 417 patients who underwent breast ultrasonography and classified as benign and malignant. Breast cancer was associated with age, BMI, and type of medication(p<0.05). Multivariate analysis showed that the odds ratio was 4.93 times higher in the 50s compared to the less than 50s, 2.43 times higher in the obese group than in the normal group, 0.14 times and 0.16 times lower in hormonal replacement therapy(p<0.05). Therefore, as age increases, periodical examination of health and appropriate weight management are needed. So this study is expected to provide basic data for identification of risk factors affecting breast cancer development.

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

Diagnostic Performance of Breast MRI in the Evaluation of Contralateral Breast in Patients with Diagnosed Breast Cancer

  • Saeed, Shaista Afzal;Masroor, Imrana;Beg, Madiha;Idrees, Romana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7607-7612
    • /
    • 2015
  • Aims: The purpose of our study was to evaluate the diagnostic performance of breast magnetic resonance imaging (MRI) in the evaluation of contralateral breast in patients with diagnosed breast cancer. A secondary objective was to determine accuracy of breast MRI in diagnosing multi-focal and multicentric lesions in the ipsilateral breast. Materials and Methods: Using a non-probability convenience sampling technique, patients with histopathologically diagnosed breast cancer with MRI of breast performed to exclude additional lesions were included. MRI findings were correlated with histopathology. In addition, follow-up imaging with mammography and ultrasound was also assessed for establishing stability of negative findings and for the detected of benign lesions. Results: Out of 157 MRI breast conducted during the period of 2008 to 2013, 49 were performed for patients with diagnosed breast cancer. The sample comprised of all females with mean age $50.7{\pm}11.0years$. The patient follow-up imaging was available for a period of 2-5 years. The sensitivity, specificity, and positive and negative predictive values of MRI in the detection of multifocal/multicenteric lesions was 85.7%, 88.8%, 60% and 96.6% respectively and for the detection of lesions in the contralateral breast were 100%, 97%, 83.3% and 100% respectively. Conclusions: Our study highlights the diagnostic performance and the added value of MRI in the detection of multifocal/multicenteric and contralateral malignant lesions. In patients with diagnosed breast cancer having dense breast parenchyma and with infiltrating lobular carcinoma as the index lesion MRI is particularly useful with excellent negative predictive value in the exclusion of additional malignant foci in the ipsilateral and contralateral breasts.

Imaging Findings of Metastatic Breast Malignant Fibrous Histiocytoma: A Case Report (전이성 유방 악성 섬유성 조직구종의 영상 소견: 증례 보고)

  • Lee, Hyun Sil;Kang, Bong Joo;Kim, Sung Hun;Lee, Ahwon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.316-320
    • /
    • 2013
  • Malignant fibrous histiocytoma (MFH) of the breast is extremely rare and most of the previous reports were focused on the clinicopathological features of breast MFH, so analysis of its imaging findings have been limited. We report a case of MFH involving left breast and left axilla, metastasized from known MFH of left forearm, with focusing on imaging findings based on radiologic evaluation of the breast including mammography, ultrasound and breast MRI.

Unusual US Findings of Diffuse Large B-Cell Lymphoma of the Breast: A Case Report (유방의 B세포 림프종의 비전형적 초음파 영상 소견: 증례 보고)

  • Kyung Eun Lee;Ok Hee Woo;Chung Yeul Kim;Kyu Ran Cho;Bo Kyoung Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.415-420
    • /
    • 2024
  • Lymphoma is an uncommon type of breast malignancy, with low prevalence. The ultrasonographic findings of breast lymphoma have been described as nonspecific. Breast lymphoma most commonly appears as a solitary hypoechoic mass on US, and usually shows hypervascularity on color Doppler US. Herein, we report an unusual case of breast lymphoma that presented as multiple bilateral hyperechoic nodules on US.

Primary Invasive Ductal Carcinoma Arising in Axillary Accessory Breast: A Case Report (겨드랑이 부유방 조직에서 발생한 원발성 유방암: 증례 보고)

  • Seo Young Park;Jeeyeon Lee;Ji Young Park;Gab Chul Kim;Jongmin Park;Jung Geun Cha;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.421-427
    • /
    • 2024
  • Ectopic breast tissue can develop along the mammary ridge from the axilla to the groin, and the most common site is the axillae. Primary carcinoma of ectopic breast tissue is extremely rare. We report a rare case of a 61-year-old woman with a palpable mass in her left axilla who had a history of surgical excision of accessory breast tissue in the same area. Mammography (MMG), including axillary tail view, ultrasound (US), and breast MRI were performed. We evaluated the extent and characteristics of the microcalcifications in the axillary tail view. A US-guided biopsy was done, and histopathology revealed an invasive ductal carcinoma. Enhanced abdominal CT revealed multiple hepatic masses consistent with metastases, and the patient received palliative chemotherapy. Herein, we present a rare case of breast cancer arising from accessory breast tissue in the axilla, best appreciated on the axillary tail view of the patient's MMG.