• Title/Summary/Keyword: breast cancer patient's

Search Result 187, Processing Time 0.026 seconds

Study on relationship of patients' information need, e-Health system use and outcomes: CHIS system in patients with breast cancer center (환자들의 정보요구가 e-Health 시스템 사용과 성과에 미치는 영향에 관한 연구: 유방암환자대상 수요자의료정보시스템을 중심으로)

  • Lee, Seog-Jun;Park, Sung-Sik;Hahm, Yukeun;Gustafson, D.
    • The Journal of Information Systems
    • /
    • v.22 no.2
    • /
    • pp.105-129
    • /
    • 2013
  • Recently, since the interest with well-being has been getting higher than ever, people want reliable source of information related with health and medical treatment. Because of the characteristics of information related with medical care, there have been difficulties to find the information from books, television and internet surfing, for treating disease. Misinformation that can be obtained when considering dangerous situations or side effects, the role of the e-Health system is becoming more important. The objective of this study is an analysis of correlation and effect among patient's information need, e-Health system use and system outcome. To achieve the object of this study, e-Health system had been given to patients of breast cancer in Wisconsin and Detroit for 16 weeks. As a result, 282 sample was gathered and modified to meet purpose of the study. As a result, the information needs of patients due to the performance of the e-Health systems and shown to affect even the perception of patients' emotional and physical health and social support.

Effects of Skin Mobilization on Pain and Joint Range Improvement in Patients with Axillary Web Syndrome: A Single Case Report

  • Choi, Suhong;Lee, Sangyeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.112-115
    • /
    • 2021
  • Objective: This study was conducted to apply skin mobilization to patients with Axillary web syndrome following breast cancer resection and to see the resulting changes in pain and joint range of motion. Design: Single case study,pre-post comparison. Methods: The subject was a female patient in her 40s who performed a mastectomy after being diagnosed with breast cancer, and then complained of uncomfortable pain from the shoulder joint to the axilla and limited range of motion. To implement a skin mobilization, the palms were adhered to the inner half of the arm, the arms were raised to a pain-free extent, and skin mobilization was performed. The skin was pulled in the direction of axilla and kept for 5 seconds 10 times for a total of 2 sets. Immediate changes in range of motion and pain were identified. Results: Following skin mobilization, there was an immediate increase in range of motion (pre 116°, post 140°) and a decrease in pain (NRS pre 5, post 2). And also uncomfortable pain, which is hard to define in words, also seems to have improved. Conclusions: Skin mobilization, which considers skin mobility for patients with Axillary web syndrome, can be considered for improving range of motion and restoring function in patients with pain due to fibrous bands around veins and lymphatic vessels, and is recommended as a new intervention method not used as a conventional treatment.

Relationship between erb-B2 mRNA Expression in Blood and Tissue of Invasive Ductal Carcinoma Breast Cancer Patients and Clinicopathological Characteristics of the Tumors

  • Moazzezy, Neda;Ebrahimi, Fatemeh;Sisakht, Mahsa Mollapour;Yahyazadeh, Hossein;Bouzari, Saeid;Oloomi, Mana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.249-254
    • /
    • 2016
  • Molecular detection methods such as RT-PCR for detecting breast cancer-associated gene expression in the peripheral blood have the potential to modify breast cancer (BC) staging and therapy. In this regard, we evaluated the potential of erb-B2 molecular marker in BC detection and analyzed the expression of erb-B2 mRNA in the peripheral blood and fresh tissue samples of 50 pretreated female BC patients and 50 healthy females by reverse transcription-PCR (RT-PCR) method. We also assessed the correlation of erb-B2 mRNA marker positivity in peripheral blood and tumor tissue samples with clinical and pathological factors in BC patients in order to evaluate its prognostic value. It was shown that there is a significant difference between healthy females and BC patients with expression of the erb-B2 molecular marker (p<0.01). A significant difference between the expression of erb-B2 in the peripheral blood and tissue samples of BC patients (p<0.01) and the frequency of circulating erb-B2 mRNA expression in peripheral blood and in tissue was detected by RT-PCR. No correlation was found between erb-B2 mRNA expression in blood or tumor tissue samples and lymph node, tumor grade, tumor stage, tumor size, patient's age, ki67, estrogen receptor (ER), progesterone receptor (PGR), P53, and HER-2 status. However, in a small subset of 31 BC patients we found that expression of erb-B2 in peripheral blood or in both peripheral blood and tumor tissue was directly correlated with lympho-vascular invasion and perineural invasion as poor prognostic features. The highest rates of erb-B2 expression in peripheral blood or tumor tissue were in the ER and PR negative and HER-2 positive group. This study suggests that the application of the RT-PCR and immunohistochemical methods for erb-B2 molecular marker detection would provide a higher detection rate, especially in early stage BC.

Evaluation of electron dose distribution obtained from ADAC Pinnacle system against measurement and Monte Carlo method for breast patients

  • Lee, S.;Lee, R.;Park, D.;S. Suh
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.82-82
    • /
    • 2003
  • Introduction: With the development of dose calculation algorithms for electron beams, 3D RTP systerns are available for electron beam dose distribution commercially. However, no studies evaluated the accuracy of dose calculation with ADAC Pinnacle system for electron beams. So, the accuracy of the ADAC system is investigated by comparing electron dose distributions from ADAC system against the BEAMnrc/DOSXYZnrc. Methods: A total of 33 breast cancer patients treated with 6, 9, and 12MeV electrons in our institution was selected for this study. The first part of this study is to compare the dose distributions of measurement, TPS and the BEAMnrc/DOSXYZnrc code in flat water phantom at gantry zero position and for a 10 ${\times}$ 10 $\textrm{cm}^2$ field. The second part is to evaluate the monitor unit obtained from measurement and TPS. Adding actual breast patient's irregular blocks to the first part, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and 3D RTP system. In addition, the dose distributions using blocks were compared between TPS and the BEAMnrc/DOSXYZnrc code. Finally, the effects of tissue inhomogeneities were studied by comparing dose distributions from Pinnacle and Monte Carlo method on CT data sets. Results: The dose distributions calculated using water phantom by the TPS and the BEAMnrc/ DOSXYZnrc code agreed well with measured data within 2% of the maximum dose. The maximum differences of monitor unit between measured and Pinnacle TPS in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. In real-patient cases, comparison of depth doses and lateral dose profiles calculated by the Pinnacle TPS, with BEAMnrc/DOSXYZnrc code has generally shown good agreement with relative difference less than +/-3%. Discussion: For comparisons of real-patient cases, the maximum differences between the TPS and BEAMnrc/DOSXYZnrc on CT data were 10%. These discrepancies were due in part to the inaccurate dose calculation of the TPS, so that it needs to be improved properly. Conclusions: On the basis of the results presented in this study, we can conclude that the ADAC Pinnacle system for electron beams is capable of giving results absolutely comparable to those of a Monte Carlo calculation.

  • PDF

Evaluation of New Material Mammopad (맘모패드의 새로운 재질에 관한 평가)

  • Moon, Young-Ju;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2019
  • Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.

A Study on Determinats of Cancer Patients's Length of Hospital Stay on Medical Charges Pattern (암 환자 재원일별 진료비 발생 양상에 미치는 결정요인)

  • Kim, Han-Kyoul;Lee, Kyoung-Sook;Kim, Yong-Ha;Kim, Kwang-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.4
    • /
    • pp.53-58
    • /
    • 2011
  • This Study is to propose the resonable management for cancer patients by identifying correlation among the treatment, their length of hospital stay and medical charges. Research subjbject is 144 patient that breast cancer, uterine cancer and Family Medical patients of inpatients in K University Hospital in Korea during six month, from January 1, 2010 to June 30, 2010. The analysis shows that the emergecy is superior range thag outpatient because each of them has 97.9%, 2.1% by looking at the path to admission. And the age of 40-49 is the higest group by age. When matrix components of breast cancer patients, principal component is composed of two axes. Factors associated with the first component appeared correlations between all variables without the age. Following results, this study is considered similar types of disease or treatments are need to introduce the DRG.

Financial Burden of Cancer Drug Treatment in Lebanon

  • Elias, Fadia;Khuri, Fadlo R;Adib, Salim M;Karam, Rita;Harb, Hilda;Awar, May;Zalloua, Pierre;Ammar, Walid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3173-3177
    • /
    • 2016
  • Background: The Ministry of Public Health (MOPH) in Lebanon provides cancer drugs free of charge for uninsured patients who account for more than half the total case-load. Other categories of cancer care are subsidized under more stringent eligibility criteria. MOPH's large database offers an excellent opportunity to analyze the cost of cancer treatment in Lebanon. Materials and Methods: Using utilization and spending data accumulated at MOPH during 2008-2013, the cost to the public budget of cancer drugs was assessed per case and per drug type. Results: The average annual cost of cancer drugs was 6,475$ per patient. Total cancer drug costs were highest for breast cancer, followed by chronic myeloid leukemia (CML), colorectal cancer, lung cancer, and Non-Hodgkin's lymphoma (NHL), which together represented 74% of total MOPH cancer drug expenditure. The annual average cancer drug cost per case was highest for CML ($31,037), followed by NHL ($11,566). Trastuzumab represented 26% and Imatinib 15% of total MOPH cancer drug expenditure over six years. Conclusions: Sustained increase in cancer drug cost threatens the sustainability of MOPH coverage, so crucial for socially vulnerable citizens. To enhance the bargaining position with pharmaceutical firms for drug cost containment in a small market like Lebanon, drug price comparisons with neighboring countries which have already obtained lower prices may succeed in lowering drug costs.

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Analysis of Multivariate System Using Mahalanobis Taguchi System (Mahalanobis Taguchi System을 이용한 다변량 시스템의 해석에 관한 연구)

  • Hong, Jung-Eui;Kwon, Hong-Kyu
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.20-25
    • /
    • 2009
  • Mahalanobis Taguchi System (MTS) is a pattern information technology, which has been used in different diagnostic applications to make quantitative decisions by constructing a multivariate measurement scale using data analytic methods without any assumption regarding statistical distribution. The MTS performs Taguchi's fractional factorial design based on the Mahahlanobis Distance (MS) as a performance metric. In this work, MTS is used for analyzing Wisconsin Breast Cancer data which has ten attributes. Ten different tests are conducted for the data to determine if the patient has cancer or not. Also, MTS is used for reducing the number of test to define the relationship between each attribute and diagnosis result. The accuracy of diagnosis is compare with two different previous research.

Internal Mammary Lymph Node Irradiation after Breast Conservation Surgery: Radiation Pneumonitis versus Dose-Volume Histogram Parameters (유방보존술 후 내유림프절 방사선 조사: 방사선 폐렴과 체적-선량 히스토그램 변수들)

  • Kim, Joo-Young;Lee, Ik-Jae;Keum, Ki-Chang;Kim, Yong-Bae;Shim, Su-Jung;Jeong, Kyoung-Keun;Kim, Jong-Dae;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • Purpose: To evaluate the association between radiation pneumonitis and dose-volume histogram parameters and to provide practical guidelines to prevent radiation pneumonitis following radiotherapy administered for breast cancer including internal mammary lymph nodes. Materials and Methods: Twenty patients with early breast cancer who underwent a partial mastectomy were involved in this study. The entire breast, supraclavicular lymph nodes, and internal mammary lymph nodes were irradiated with a dose of 50.4 Gy in 28 fractions. Radiation pneumonitis was assessed by both radiological pulmonary change (RPC) and by evaluation of symptomatic radiation pneumonitis. Dose-volume histogram parameters were compared between patients with grade <2 RPC and those with grade ${\geq}$2 RPC. The parameters were the mean lung dose, V10 (percent lung volume receiving equal to and more than 10 Gy), V20, V30, V40, and normal tissue complication probability (NTCP). Results: Of the 20 patients, 9 (45%) developed grade 2 RPC and 11 (55%) did not develop RPC (grade 0). Only one patient developed grade 1 symptomatic radiation pneumonitis. Univariate analysis showed that among the dose-volume histogram parameters, NTCP was significantly different between the two RPC grade groups (p<0.05). Fisher's exact test indicated that an NTCP value of 45% was appropriate as an RPC threshold level. Conclusion: This study shows that NTCP can be used as a predictor of RPC after radiotherapy of the internal mammary lymph nodes in breast cancer. Clinically, it indicates that an RPC is likely to develop when the NTCP is greater than 45%.