• Title/Summary/Keyword: breakdown

Search Result 4,095, Processing Time 0.038 seconds

Asymmetric 및 Symmetric MOSFET 소자의 Drain Breakdown 특성 분석

  • Choe, Pyeong-Ho;Kim, Sang-Seop;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.232.2-232.2
    • /
    • 2013
  • 본 연구에서는 asymmetric과 symmetric MOSFET 소자의 drain breakdown 및 snapback 특성을 분석하였다. 실험에서는 두 MOSFET 소자의 동작 영역에서 게이트와 드레인에 각각 전압을 인가하였다. 드레인 전류-전압 곡선으로 부터 drain breakdown 전압과 snapback 전압을 추출하였다. 결과 avalanche breakdown 발생 전의 드레인 전류는 asymmetric 구조의 경우 더 작은 값을 보였으며 이는 asymmetric 구조에서의 drain field 가 더 낮기 때문이다. 따라서 impact ionization은 asymmetric 구조에서 덜 발생하며, snapback 전압은 avalanche breakdown voltage가 작은 asymmetric 구조에서 크게 나타났다.

  • PDF

불평등 전계에서 $SF_6/N_2$의 초고압 AC전압 절연내력 시뮬레이션

  • Heo, Chang-Su;Lee, Byeong-Taek;Choe, Sun-Ho;Sim, Myeong-Seop;An, Jeong-Sik;Hwang, Cheong-Ho;Jang, Yong-Mu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.37-37
    • /
    • 2010
  • In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. In this paper, breakdown experiment values and breakdown simulation value are compared. Streamer theory was used for predicting breakdown voltage. For accurate simulation, this simulation apply utilization factor using CST program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. But with gap lengths increasing, the breakdown voltage is saturated. So simulation need surface roughness factor.

  • PDF

Prediction of Life-Time on the Macroscopic Interface between Solid Materials with Analysis of V-t Characteristics (V-t 특성 분석에 의한 고체 거시계면의 수명 평가)

  • 오재한;이경섭;배덕권;김충혁;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.607-611
    • /
    • 2000
  • The characteristics on the interface between Epoxy and EPDM which are materials of the underground insulation systems of power delivery have studied. The breakdown strength of specimens are observed by applying high AC voltage at the room temperature. The breakdown times under the constant voltage below the breakdown voltage were gained. As constant voltage is applied the breakdown time is proportion to the breakdown strength. The life exponent n is gained by inverse power law and the long breakdown life time can be evaluated. AC breakdown strength and life time is improved by oiling to the interface. When the low viscosity oil is spread interface has the highest life time.

  • PDF

Analysis for Breakdown Voltage of Double Gate MOSFET according to Device Parameters (소자파라미터에 따른 DGMOSFET의 항복전압분석)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.372-377
    • /
    • 2013
  • This paper have presented the breakdown voltage for double gate(DG) MOSFET. The analytical solution of Poisson's equation and Fulop's breakdown condition have been used to analyze for breakdown voltage. The double gate(DG) MOSFET has the advantage to reduce the short channel effects as improving the current controllability of gate. But we need the study for the breakdown voltage of DGMOSFET since the decrease of the breakdown voltage is unavoidable. To approximate with experimental values, we have used the Gaussian function as charge distribution for Poisson's equation, and the change of breakdown voltage has been observed for device geometry. Since this potential model has been verified in the previous papers, we have used this model to analyze the breakdown voltage. As a result to observe the breakdown voltage, the smaller channel length and the higher doping concentration become, the smaller the breakdown voltage becomes. Also we have observed the change of the breakdown voltage for gate oxide thickness and channel thickness.

V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages ($SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성)

  • Lee, Bok-Hui;Lee, Gyeong-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

Copper Particle Effect on the Breakdown Strength of Insulating Oil at Combined AC and DC Voltage

  • Wang, You-Yuan;Li, Yuan-Long;Wei, Chao;Zhang, Jing;Li, Xi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.865-873
    • /
    • 2017
  • Converter transformer is the key equipment of high voltage direct current transmission system. The solid suspending particles originating from the process of installation and operation of converter transformer have significant influence on the insulation performance of transformer oil, especially in presence of DC component in applied voltage. Under high electric field, the particles easily lead to partial discharge and breakdown of insulating oil. This paper investigated copper particle effect on the breakdown voltage of transformer oil at combined AC and DC voltage. A simulation model with single copper particle was established to interpret the particle effect on the breakdown strength of insulating oil. The experimental and simulation results showed that the particles distort the electric field. The breakdown voltage of insulating oil contaminated with copper particle decreases with the increase of particle number, and the breakdown voltage and the logarithm of particle number approximately satisfy the linear relationship. With the increase of the DC component in applied voltage, the breakdown voltage of contaminated insulating oil decreases. The simulation results show that the particle collides with the electrode more frequently with more DC component contained in the applied voltage, which will trigger more discharge and decrease the breakdown voltage of insulating oil.

Dielectric Characteristics of Subcooled $LN_2$ for Insulation Design of HTS Fault Current Limiters (고온초전도 한류기의 절연설계를 위한 과냉각 액체질소의 절연내력 특성)

  • 백승명;정종만;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.46-50
    • /
    • 2003
  • In the dielectric insulation design of any high temperature superconducting (HTS) apparatus as well as HTS fault current limiter in the electrical power systems, the breakdown characteristics of cryogenic coolants such as liquid nitrogen ($LN_2$) are an important factor of the insulating engineering. Previous reports concerned with the breakdown characteristics of liquid nitrogen have pointed out that bubbles and gaseous nitrogen have a treat influence on their breakdown phenomena, However, useful data for practical insulation design of HTS fault CUITent limiter operating at subcooled L$N_2$ have not been obtained enough. Therefore, this paper presents an experimental investigate of breakdown phenomena in liquid nitrogen under AC voltage, And, we observed the breakdown voltage (BDV) of liquid nitrogen with lowering temperature. The Weibull plots of the breakdown voltage of subcooled $LN_2$ for the needle-plane electrode with d= 10 mm are studied, The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated, The relationship between the AC breakdown characteristics and the temperature were clarified.

Breakdown Characteristics of Liquid Nitrogen Induced by Quench (Quench에 의해 유도되는 액체 $N_2$의 절연파괴 특성)

  • Kim, Yeong-Seok;Jeong, Jong-Man;Gwak, Min-Hwan;Jeong, Sun-Yong;Kim, Sang-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • Electrical breakdown characteristics of liquid nitrogen($LN_2$) used as both coolant and insulator for high $T_c$ superconductor system are very important. This paper presents dynamic breakdown characteristics fo $LN_2$ by quench phenomena of thermal bubble under high electric field. Experimental results revealed dynamic breakdown voltage fell down drastically compared with the static breakdown voltage without the quench. Because of increasing heat power, bubble size becomes big and breakdown voltage decreases. The breakdown voltage mechanism of $LN_2$ depends on thermal bubble effect. In the Electrode arrangement, electrical breakdown voltage of horizontal arrangement appears lower than that of vertical arrangement. Also, we observed the behavior of thermal bubbles in $LN_2$ which were generated after quench using camera.

  • PDF

Correlation Coefficient of Leaf Breakdown with Some Agronomic Characters in Flue- Cured Tobacco (Nicotiana tabacum L.) (황색종 연초(Nicotiana tabacum L.)에서 엽탈락과 농경적 형질과의 상관)

  • 조수헌;진정의
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.11 no.2
    • /
    • pp.149-155
    • /
    • 1989
  • This study was conducted to obtain the breeding information for the leaf breakdown, and correlation coefficients between leaf breakdown and some agronomic characters in flue-cured tobacco at Taegu Experiment Station, Korea Ginseng & Tobacco Research Institute. NC 95 and NC 2326 were used as parents. The bulk method procedure was used from the F2 to the F4 generations, 54 plants were selected among F4, and 11 lines were selected among 54 F5 which based on high resistance to bacterial wilt compared with NC2326. The entries were composed of parents and 11 F6 advanced lines, and designed in randomized block with 3 replications. Plant seedlings were transplanted in 16 April. The number of breakdown leaf were investigated at flowering stage, 18 June. There were significant difference between NC 95 and NC 2326 for the number of breakdown leaf, number and weight of ground suckers, days to flower, yield and resistance to bacterial wilt, and similar results were appeared among lines. Estimated heritability in the broad-sense ranged from 59.3% to 87.4% for all characters. Most of genetic correlations were higher than phenotypic coefficients between characters. Number of breakdown leaf was positively correlated with days to flower, the number and weight of ground suckers, while it was negative to yield. One line among 11 had few breakdown leaf, low producted ground suckers and high resistance to bacterial wilt. Above results suggest that the number and weight of ground suckers can be use as a selection criterion for leaf breakdown even under the condition without leaf breakdown.

  • PDF

A Study on Breakdown Voltage of Double Gate MOSFET (DGMOSFET의 항복전압에 관한 연구)

  • Jung, Hak-Kee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.693-695
    • /
    • 2012
  • This paper have presented the breakdown voltage for double gate(DG) MOSFET. The analytical solution of Poisson's equation and Fulop's breakdown condition have been used to analyze for breakdown voltage. The double gate(DG) MOSFET as the device to be able to use until nano scale has the adventage to reduce the short channel effects. But we need the study for the breakdown voltage of DGMOSFET since the decrease of the breakdown voltage is unavoidable. To approximate with experimental values, we have used the Gaussian function as charge distribution for Poisson's equation, and the change of breakdown voltage has been observed for device geometry. Since this potential model has been verified in the previous papers, we have used this model to analyze the breakdown voltage. As a result to observe the breakdown voltage, the smaller channel length and the higher doping concentration become, the smaller the breakdown voltage becomes. Also we have observed the change od the breakdown voltage for gate oxide thickness and channel thickness.

  • PDF