• Title/Summary/Keyword: breakage

Search Result 827, Processing Time 0.023 seconds

Ozone Inactivation of Bacteriophage f2 (오존에 의한 bacteriophage f2의 살균작용(殺菌作用))

  • Kim, Chi-Kyung
    • Applied Microscopy
    • /
    • v.11 no.1
    • /
    • pp.29-38
    • /
    • 1981
  • Bacteriophage f2 were treated with ozone at various concentrations for 20 minutes. The inactivation kinetics of f2 phage were examined during ozonation. In order to study the mode of action of ozone on the phage f2, absorption of the phage to the host pili was meassured by utilyzing radioactivity of tritium incorporated into the phage RNA. Sucrose density gradient analysis and electron microscopy were also used to prove the mechanism of ozone inactivation of the phage. Strucural proteins of the phage were broken by ozonation into many protein subunits. The extent of phage breakage was proportional to ozone concentration and reaction time. Percent decrease of the phage absorption to the host pili was coincident with the rate of ozone inactivation of the phage. Ozone inactivation of bacteriophage f2 was shown to be caused by the breakage of the structural protein and blockage of the phage absorption to the host pili.

  • PDF

Breakage of Core Reamer During Anterior Cruciate Ligament Reconstruction -A Case Report- (자가 슬개건을 이용한 전방십자인대 재건술 시 경골터널 생성중 핵심 확공기의 파열 - 증례보고 -)

  • Noh, Jung-Ho;Yang, Bo-Kyu;Park, Jung-Tae;Je, Min-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.1
    • /
    • pp.33-35
    • /
    • 2010
  • This is a case of the core reamer breakage during anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. A 19-year-old man with acute anterior cruciate ligament rupture had reconstruction surgery. During tunneling in the proximal tibia, the core reamer have been cracked open and broken. Rest of the procedure was performed routinely except the tibial sided fixation of bone block which was performed with larger interference screw than usual. The patient followed the accelerated rehabilitation program. The result was satisfactory at 2 years after surgery.

  • PDF

Percutaneous self-injury to the femoral region caused by bur breakage during surgical extraction of a patient's impacted third molar

  • Yu, Tae Hoon;Lee, Jun;Kim, Bong Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.5
    • /
    • pp.281-283
    • /
    • 2015
  • Extraction of an impacted third molar is one of the most frequently performed techniques in oral and maxillofacial surgery. Surgeons can suffer numerous external injuries while extracting a tooth, with percutaneous injuries to the hand being the most commonly reported. In this article, we present a case involving a percutaneous injury of the surgeon's femoral region caused by breakage of the fissure bur connected to the handpiece during extraction of the third molar. We also propose precautions to prevent such injuries and steps to be undertaken when they occur.

Fault Detection of a Gear with Initial Pitting using the Boomed Phase Map of Continuous Wavelet Transform (연속 웨이블렛 변환의 확대된 위상 지도를 이용한 기어의 초기 퍼팅 결함 진단)

  • Lee, Sang-Gwon;Sim, Jang-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1759-1766
    • /
    • 2001
  • Vibration transient generated by developing localized fault in gear can be used as indicators in gear fault detection. In this paper, we propose the zoomed phase map for a fault signal using continuous wavelet transfers to detect this vibration transient. Local fault induces the abrupt fluctuation of load exciting tooth and phase lag in the vibration signal measured on the gearbox. The relatively large fault like "tip breakage" easily can be detected by the clear fluctuation of exciting load. However, minor fault like "initial pitting"cannot be detected using the load fluctuation. To defect this kind of minor fault, the phase map for a fault signal is taken into account. The phase lag by minor fault is observed well in the zoomed phase map.

SPC 기법에 의한 밀링공구의 파손분석 및 검색

  • 서석환;전치혁;최용종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.47-51
    • /
    • 1992
  • Automatic detection of tool breakage during NC machining is a key issue not only for improving productivity but to implement the unattended manufacturing system. In this paper, we develop a vibration sensor-based tool breakage detection system for NC milling processes. The system obtains the time-domain vibration signal from the sensor attached on the spindle bracket of our CNC machine and declares tool failures through the on-line monitoring schemes. For on-line detection, our approach is to use the PSC(statistical process control) methods being increasingly used for on-line process control. The main thrust of this paper is to propose and compare the performance of SPC methods including : a) X-bar control scheme, b) S control scheme, c)EWMA (exponentially weighted moving average) scheme, and d) AEWMA (adaptive exponentially weighted moving average) scheme. The performance of the control schemes are compared in terms of the type 1 and 2 error calculated from the experiment data.

A Study on Tool Monitoring for High Speed Tapping using AE Signal (AE센서를 이용한 고속 탭핑용 공구 모니터링에 관한 연구)

  • 김용규;이돈진;김선호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.315-318
    • /
    • 1997
  • In terms of productivity, the speed of machining process has been increasing in most of engineering part. But the tapping process does not reach at enough level compared with other machining processes because of its complicate cutting mechanism. In the high speed tapping process, the one of important elements is tool monitoring system to prevent tool breakage. This paper describes tool monitoring system by acoustic emission(AE) in the tapping process. We used 2 types of AE sensors in this test. The one is commercial sensor which is used in other machining monitoring system like polishing and the other is a self-fabricated sensor for this test. In this test we purpose to find out the frequency of AE signal in tapping process and verify the possibility of applying AE sensor in in-process tapping monitoring system. Also grasp of characteristic of tapping process by AE signal is handled.

  • PDF

A Study on Guide System for Optimization of Machining Process (기계가공 최적화를 위한 가이드시스템에 관한 연구)

  • Choi, Jong-Geun;Yang, Min-Yang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.4
    • /
    • pp.71-83
    • /
    • 1989
  • The optimization in the machining process has been a long-standing goal of the manufacturing community. The optimization is composed of two main subjects;one is to select an optimum cutting condition, and the other is to detect the emergency situation and take necessary actions in real-time base. This paper proposes a reliable and practical guide system whose purpose is the optimization of cutting conditions, and the detection of tool failure in the machining process. The optimal cutting conditions are determined through the estimation of tool wear rate and the establishment of access- ible field from the measured cutting temperature and force. Tool breakage is detected by the normal force component acting on minor flank face extracted from on-line sensed feed force and radial force. In experiments, the proposed guide system has proved availability for the decision of reliable cutting conditions for the given tool-work system and the detection of tool breakage in ordinary cutting environments.

  • PDF

Roll의 수명예측 model 개발

  • 배용환;장삼규;이석희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.306-312
    • /
    • 1992
  • The prevention of roll breakage in hot rolling process is improtant to reduce maintenance cost and production loss. Rolling conditions such as the roll force and torque have been intensively studied to overcome the roll breakage. in the present work, a model for life prediction of work rolls under working condition was developed and discussed. The model consists of stress analysis, crack propagation, wear and fatigue calculation model. Roll life can be predicted by stress, crack depth and fatigue damage calculated from this model. The reliability of stress analysis is backed up by the FEM analysis. From the result of simulation using by pressent model, although the fatigue damage of back up roll reachs 80% of practical limit, that of workroll was less than 40%. In edge section of workroll stress amplification is found by wear and bender effect. We can judge that workroll failures are not due to fatigue damage, crack propagation by bending stress but stress amplification by wear and bender in present working condition.

Centrifuge Model Experiments on Failure of Reinforced Earth Retaining Walls due to Breakage of Reinforcements (보강재 절단에 의한 보강토옹벽의 파괴에 관한 원심모형실험)

  • Yoo, Nam Jae;Kim, Young Gil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.161-167
    • /
    • 1992
  • Centrifuge model tests were performed to find the capacity and the failure mechanism of reinforced earth retaining wall subjected to the failure due to breakage of reinforcements. Parametric model tests were carried out to figure out effects of factors on the capacity of wall by changing materials of reinforcing strip, strip length, strip arrangement. Tests were analyzed and were compared with the various design methods currently in use to verify feasibility of them. As a result of it, a proper design method was recommended.

  • PDF

Effect of the Extrusion Ratios on Fiber Breakage and Orientation in Hot Extrusion Process in Metal Matrix Composites (금속복합재료의 열간압출공정에 있어서 압출비가 섬유의 파단 및 배향에 미치는 영향)

  • Kang, C.G.;Kang, S.S.;Kim, B.H.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1740-1750
    • /
    • 1993
  • The aluminar short fiber reinforced composite materials for hot extrusion were fabricated by semi-solid stirring method, and extruded at extrusion temperature $400^{\circ}C$ with various extrusion ratio. The hot extrusion load of volume fraction 15% metal matrix composites and base alloy Al7075 has been compared. The fiber length distribution, fiber breakage and fiber orientation are investiged to know the fiber behaviour in before and after hot extrusion. The tensile strength of the hot extruded billet are experimentally determined for different of extrusion ratios, and compared with theorically calculated strength.