• 제목/요약/키워드: brass

검색결과 414건 처리시간 0.02초

어류 가두리에 적용하기 위한 황동 직조 어망의 성능 평가 (Evaluation of brass weaving fishing nets for aquaculture cage applications)

  • 김건우;박수봉
    • 수산해양기술연구
    • /
    • 제60권2호
    • /
    • pp.186-193
    • /
    • 2024
  • Most fishing nets used in fish cage aquaculture are made of synthetic fibers such as polyamide (PA) and polyethylene (PE). Therefore, it is challenging to maintain the internal volume of the fish cage due to biofouling, which can increase the load on the cage or reduce dissolved oxygen levels by impeding smooth current flow. To address this issue, research has been conducted to replace conventional synthetic fiber cage nets with brass nets, demonstrating certain benefits such as improved productivity and ease of fish cage management. However, given the need for a more thorough examination of brass fishing net weaving technology and performance, this study assessed the optimal weaving method for brass fishing nets to be used in fish cages. Additionally, it provided essential data for the practical application of brass fishing nets by evaluating their weight, tensile strength, elongation, fatigue resistance, and wear resistance. The study concluded that weaving brass fishing nets using the chain link method ensures durability, ease of installation, and compact storage in a scroll-like form. Moreover, due to their superior fatigue and wear resistance properties, brass nets can offer increased utility if appropriate net diameter and length are selected to compensate for their higher weight per unit area and relatively higher cost compared to existing fiber fishing nets.

전자현미경 In-Situ 관찰방법을 이용한 황동의 절삭성평가 (Estimation of Machinability of Lead Brass Based on In-Situ Observation in Scanning Electron Microscope)

  • 정승부;임옥동;안성욱
    • Applied Microscopy
    • /
    • 제24권3호
    • /
    • pp.87-93
    • /
    • 1994
  • In order to elucidate the machinability of lead brass, orthogonal machining experiment was conducted in SEM(Scanning Electron Microscope) equipped with a micro-machining device at a cutting speed of $7{\mu}m/s$ for brass containing 0.2 to 3wt% Pb. The microfactors (i.e., shear angle, contact length between chip and tool) were determined by in-situ observations. Machinability of brass containing lead is discussed in terms of the microfactors and the cutting resistant force tested by lathe cutting. The dynamic behavior of the chip formation of lead brass during the machining process was examined: The chips of lead brass form as a shear angle type. The shear angle increases with the content of lead in (6:4) brass. The pronounced effect of lead on the contact length between chip and tool was observed above 1% Pb. The cutting resistant force tested by lathe decreases remarkably with the lead content in brass. The observed microfactors are in close relation to the tested resistant force in macromachining.

  • PDF

선박용 Al-황동세관의 SCC에 미치는 부식환경의 영향 (Effect of corrosion environment on the SCC of Al-brass tube for vessel)

  • 임우조;정해규
    • 수산해양기술연구
    • /
    • 제39권4호
    • /
    • pp.291-297
    • /
    • 2003
  • Al-brass is usually used as the tube material of vessel's heat exchanger for seawater cooling system because it has high thermal conductivity and good mechanical properties and high corrosion resistance due to cuprous oxide (Cu20) layer against seawater. However, Al-brass tubes of heat exchanger for vessel at the actual environment is reported that local corrosion such as stress corrosion cracking occurred by synergism effect between mechanical factor and corrosion environment In this paper, the effect of corrosion environment on the stress corrosion cracking of Al-brass in various NH4OH of 3.5% NaCl solution, under flow by constant displacement tester. Based on the test results, the behavior of polarization, stress corrosion crack propagation and dezincification phenomenon of Al-brass are investigated. The main results are as follows:(1) Increasing range of potential from open circuit potential to repassivation gets lower, as the contain rate of NH4OH gets higher. (2) As contain rate of NH4OH gets higher, SCC of Al-brass is become activation but the protection film(Cu20) of Al-brass is created in 3.5% NaCl solution. (3) According as content of NH4OH increases in 3.5% NaCl solution, the dezincifiction area is spread. It is concluded that dezincification occurred by localized preferential anodic dissolution at stress focusing region.

6.6kV-200A급 초전도 한류기 DC Reactor용 전류도입선의 비정상상태 해석 (Unsteady-state analysis of current lead for DC Reactor of 6.6kV-200A superconductor current limiter)

  • 김형진;권기범;정은수;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.182-185
    • /
    • 2003
  • Temperature distribution and cooling load in binary current lead are analized, occurring fault current at DC Reactor type superconductor fault current limiter. It is assumed that Normal operating current is 300 A and fault current is 3000 A. Unsteady-state temperature distribution and cooling load of brass current lead optimized for 300 A and 1000 A are calculated by numerical method with TDMA. In the result of calculation, temperature increase in the brass current lead optimized for 300 A is higher than that in the brass current lead optimized for 1000 A, but the temperature increase in the brass current lead optimized for 300 A is not serious. Moreover, increase of cooling load in the brass current lead optimized for 300 A is higher than that in the brass current lead optimized for 1000 A, but normal cooling load in the brass current lead optimized for 300 A is lower than that in the brass current lead optimized for 1000 A. Therefore, designing current lead in superconductor fault current limiter had better to optimize for normal operating current.

  • PDF

Influence of brass laminate volume fraction on electromechanical properties of externally laminated coated conductor tapes

  • Bautista, Zhierwinjay M.;Shin, Hyung-Seop;Lee, Jae-Hun;Lee, Hunju;Moon, Seung-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권3호
    • /
    • pp.6-9
    • /
    • 2016
  • The enhancement of mechanical properties of coated conductor (CC) tapes in practical application are usually achieved by reinforcing through lamination or electroplating metal layers on either sides of the CC tape. Mechanical or electromechanical properties of the CC tapes have been largely affected by the lamination structure under various loading modes such as tension, bending or even cyclic. In this study, the influence of brass laminate volume fraction on electromechanical properties of RCE-DR processed Gadolinium-barium-copper-oxide (GdBCO) CC tapes was investigated. The samples used were composed of single-side and both-side laminate of brass layer to the Cu-stabilized CC tape and their $I_c$ behaviors were compared to those of the Cu-stabilized CC tape without external lamination. The stress/strain dependences of $I_c$ in laminated CC tapes under uniaxial tension were analyzed and the irreversible stress/strain limits were determined. As a result, the increase of brass laminate volume fraction initially increased the irreversible strain limit and became gradual. The corresponding irreversible stress limit, however, showed no difference even though the brass laminate volume fraction increased to 3.4. But the irreversible load limit linearly increased with the brass laminate volume fraction.

Brass fillers in friction composite materials: Tribological and brake squeal characterization for suitable effect evaluation

  • Kchaou, Mohamed;Sellami, Amira;Abu Bakar, Abd. Rahim;Lazim, Ahmad Razimi Mat;Elleuch, Riadh;Kumar, Senthil
    • Steel and Composite Structures
    • /
    • 제19권4호
    • /
    • pp.939-952
    • /
    • 2015
  • In this paper, brake pad performance of two organic matrix composites namely, Sample 1 (contains no brass filler) and Sample 2 (contains 1.5% brass filler), is studied based on tribological and squeal noise behavior. In the first stage, a pin-on-disc tribometer is used to evaluate the frictional behavior of the two pads. On the following stage, these pads are tested on squeal noise occurrence using a drag-type brake dynamometer. From the two type of tests, the results show that; (i) brass fillers play a dual role; firstly as reinforcing element of the brake pad providing primary contact sites, and secondly as solid lubricant by contributing to the formation of a layer of granular material providing velocity accommodation between the pad and the disc; (ii) brass fillers contribute to friction force stabilization and smooth sliding behavior; (iii) the presence of small weight quantity of brass filler strongly contributes to squeal occurrences; (iv) there is close correlation between pin-on-disc tribometer and brake dynamometer tests in terms of tribological aspect.

Application of brass scrubber filter with copper hydroxide nanocomposite structure for phosphate removal

  • Hong, Ki-Ho;Yoo, In-Sang;Kim, Sae-Hoon;Chang, Duk;Sunwoo, Young;Kim, Dae-Gun
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.199-204
    • /
    • 2015
  • In this study, a novel phosphorus removal filter made of brass scrubber with higher porosity of over 96% was fabricated and evaluated. The brass scrubber was surface-modified to form copper hydroxide on the surface of the brass, which could be a phosphate removal filter for advanced wastewater treatment because the phosphates could be removed by the ion exchange with hydroxyl ions of copper hydroxide. The evaluation of phosphate removal was performed under the conditions of the batch type in wastewater and continuous type through filters. Filter recycling was also evaluated with retreatment of the surface modification process. The phosphate was rapidly removed within a very shorter contact time by the surface-modified brass scrubber filter, and the phosphate mass of 1.57 mg was removed per gram of the filter. The possibility of this surface-modified brass scrubber filter for phosphorus removal was shown without undesirable sludge production of existing chemical phosphorus removal techniques, and we feel that it would be very meaningful as a new wastewater treatment.

공구 경사각의 변화에 따른 연질 재료(Cu alloy and Al alloy)의 절삭 특성에 관한 연구 (A study on the cutting character of soft materials(Cu alloy and Al alloy) with change of tool rake angles)

  • 염성하;현청남;오재응
    • 오토저널
    • /
    • 제10권4호
    • /
    • pp.85-96
    • /
    • 1988
  • 제품생산의 고정밀화 및 고품질화로 정밀 절삭가공에서 공구의 형사에 따라 많은 변수가 있으므로 공구의 상면 경사각을 변화시키면서 절삭저항, 비절삭저항, 거칠기 등을 energy mothod에 의하여 최적조건을 구한 결과(6-4) brass 에서는 경사각 20.deg., 25.deg.에서 Al alloy 에서는 0.deg., 20.deg.에서 가장 작게 나타났으며 거칠기는 (6-4)brass 에서는 경사각 20.deg. 에서 Al alloy에서는 15.deg.에서 가장 작게 나타났다.

  • PDF

유방암 방사선치료시 조직등가보상체와의 비교를 통한 Brass mesh bolus의 유용성 평가 (Comparison and validation of Brass mesh bolus using tissue equivalent bolus in the breast cancer radiotherapy)

  • 봉주연;김경태;전미진;하진숙;신동봉;김세준;김종대
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.93-101
    • /
    • 2017
  • 목 적: 유방암 방사선 치료에서 조직등가보상체의 단점을 해결하기 위해 황동그물망보상체(Brass mesh bolus)가 최근 연구되고 있다. 본 연구의 목적은 국내에 처음 소개되는 황동그물망보상체의 안정성을 조사하고, 표면선량을 평가하고자 하였다. 대상 및 방법: 조직등가보상체 5 mm와 가장 비슷한 황동그물망보상의 두께를 확인하기 위해 표면선량을 측정하였다. 6 MV 선형가속기와 광자극형광선량계(optically stimulated luminescent dosimeter, OSLD)를 사용하였다. 흉곽팬텀을 이용한 2문 대항접선조사를 황동그물망보상체와 조직등가보상체의 비교를 통하여 연구에 적용하였다. 결 과: 표면선량 측정을 기반으로 조직등가보상체 5 mm와 가장 유사한 두께는 황동그물망보상체를 두 겹에 해당되는 3 mm였고, 평균 상대오차율은 0.38 %였다. 흉곽팬텀을 사용한 황동그물망보상체의 표면선량은 조직등가보상체에 비해 약 1.069배 증가하였다. 결 론: 본 실험에서 황동그물망보상체는 기존 조직등가보상체 선량균등도가 향상된 것으로 확인되었다. 실험을 바탕으로 황동그물망보상체가 기본 조직등가보상체를 대체 가능 할 것으로 사료된다. 하지만 다양한 임상적 평가가 필요할 것으로 사료된다.

  • PDF

Effects of differently hardened brass foil laminate on the electromechanical property of externally laminated CC tapes

  • Bautista, Zhierwinjay;Shin, Hyung-Seop;Mean, Byoung Jean;Lee, Jae-Hun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권4호
    • /
    • pp.21-24
    • /
    • 2016
  • The mechanical properties of REBCO coated conductor (CC) wires under uniaxial tension are largely determined by the thick component layers in the architecture, namely, the substrate and the stabilizer or even the reinforcement layer. Depending on device applications of the CC tapes, it is necessary to reinforce thin metallic foils externally to one-side or both sides of the CC tapes. Due to the external reinforcement of brass foils, it was found that this could increase the reversible strain limit from the Cu-stabilized CC tapes. In this study, the effects of differently hardened brass foil laminate on the electromechanical property of CC tapes were investigated under uniaxial tension loading. The tensile strain dependence of the critical current ($I_c$) was measured at 77 K and self-field. Depending on whether the $I_c$ of CC tapes were measured during loading or after unloading, a reversible strain (or stress) limit could be determined, respectively. The both-sides of the Cu-stabilized CC tapes were laminated with brass foils with different hardness, namely 1/4H, 1H and EH. From the obtained results, it showed that the yield strength of the brass laminated CC tapes with EH brass foil laminate was comparable to the one of the Cu-stabilized CC tape due to its large yield strength even though its large volume fraction. It was found that the brass foil with different hardness was mainly sensitive on the stress dependence of $I_c$, but not on the strain sensitivity due to the residual strain induced in the laminated CC tapes during unloading.