• 제목/요약/키워드: brachytherapy source

검색결과 82건 처리시간 0.026초

Personal computer를 이용한 자궁경부암의 고선량을 강내치료 계획 (Treatment Planning Software for High Dose Rate Remote Afterloading Brachytherapy of Uterine Cervical Cancer)

  • 허승재;강위생
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.183-186
    • /
    • 1986
  • 고선량율을 이용한 자궁강내 치료시 정확하고 신속한 계산을 위하여 저자들은 개인용 컴퓨터를 이용하여 기준점의 선량분포 및 방사선조사 시간을 간편하게 계산할 수 있는 software를 개발하였다. 치료 계획용 software를 이용하여 짧은 시간내에 선량 분포 및 조사시간을 용이하고 정확하게 계산할 수 있으며, 고선량을 자궁경부암 임상적응에 효과적으로 이용할 수 있어서 보고한다.

  • PDF

근접조사 치료에 사용되는 $^{60}$ Co source의 조직내에서 선량분포 (Dose Distribution of $^{60}$ Co Source as Brachytherapy in Tissue)

  • 유명진
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.85-90
    • /
    • 1990
  • Berger formulation was used to calculate the dose distribution of $^{60}$ Co source in tissue. $^{60}$ Co source was supposed as point source. The effect of the stainless-steel around the source was considered and Taylor Approximation Method was used for calculating exposure build-up factor. Calculated depth dose data was compared with measured data which was measured by the ionization chamber.

  • PDF

전립선암 근접시료시 주변 장기 선량 평가 (Radiation Dose Calculation in the Surrounding Organs during Brachytherapy of Prostate Cancer)

  • 김정훈;임창선;황주호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권3호
    • /
    • pp.172-177
    • /
    • 2008
  • 정량적인 방사선치료 선량을 예측하기위한 일환으로 한국표준남성에 기초하여 수학적 모의피폭체를 제작하였다. 이후 전립선을 선원장기로 하여 전립선암 근접치료 시 발생할 것으로 예상되는 전립선 및 주변장기의 흡수선량을 산정하였다. 모의모사를 위하여 방사성핵종은 전립선 근접치료에 유용하게 사용되는 $^{25}I$$^{103}Pd$선정하였고, 초기 방사능을 1 Ci를 투여하는 것으로 가정하였다. 그 결과 선원장기인 전립선이 $^{125}I$$^{103}Pd$ 경우 각각 101 Gy/Ci와 7.24 Gy/Ci를 나타냈으며, 전립선을 제외하고 흡수선량이 높은 장기는 비교적 전립선과 인접되어 있는 장기 즉 음경과 음낭, S자결장, 정소, 방광순으로 나타났다.

  • PDF

밀봉선원의 성능시험을 위한 장치 개발 및 적용 (Development and Application of Test Apparatus for Classification of Sealed Source)

  • 김동학;서기석;방경식;이주찬;손광재
    • Journal of Radiation Protection and Research
    • /
    • 제32권1호
    • /
    • pp.35-44
    • /
    • 2007
  • 밀봉선원은 과학기술부고시에 의거하여 사용용도별로 등급에 따라 해당 성능시험을 수행하고, 각 성능시험을 거친 후 해당 방사성핵종의 방사능 누설량이 200베크렐을 초과하지 아니하여야 한다. 이러한 성능시험은 온도시험, 의부압력시험, 충격시험, 진동시험 및 관통시험으로 구성되어 있으며 등급에 따라서 각 성능시험의 조건이 각각 다르다. 본 연구에서는 진동시험을 제외한 성능시험을 위한 장치를 개발하고 이를 세 가지 종류의 밀봉선원의 성능시험에 적용하였다. 의료용 근접치료기에 사용되는 근접치료기용 선원은 5등급의 온도시험, 3등급의 외압시험, 2등급의 충격시험을 수행하여 'C53211' 등급의 기준에 적합함을 보였다. 산업용 조사기에 사용되는 $^{75}Se$$^{169}Yb$ 선원에 대하여 4등급의 온도시험, 3등급의 외압시험, 5등급의 충격시험과 관통시험을 실시하여 'C43515' 등급의 기준에 적합함을 입증하였다.

근접방사선치료용 CsPbBr3 선량계 제작 및 적용가능성 평가 (Development and Feasibility Evaluation of CsPbBr3 Dosimeter for Brachytherapy)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.405-410
    • /
    • 2022
  • 근접방사선치료에서는 종양조직을 사멸시키기 위하여 선원을 인체 내부에 삽입하기 때문에 선원의 위치 정확성을 정확히 파악하는 것이 중요하다. 본 연구에서는 기존 사용되는 검출기 재료로 사용되는 물질보다 저렴하고 제조 공정이 간단하여 기존 물질들을 대체할 수 있는 CsPbBr3를 사용하여 근접방사선치료용으로 사용가능한 선량계를 개발하고자 하였다. 그리고 192Ir 선원에서의 재현성, 선형성, 거리의존성 분석하여 선량계의 기초 성능을 평가하였다. 재현성 평가 결과, RSD는 1.36%로 기준치 1.5%를 만족하였다. 선형회귀분석에 따른 선형성 평가결과, 0.9993의 R2값으로 기준치 0.9990 이상의 R2이 제시되었다. 거리의존성 평가결과 거리가 멀어짐에 따라 지수적으로 일정하게 감소하는 신호값을 확인하였다. 재현성, 선형성, 거리의존성 평가결과에 기준 이상의 성능을 제시하여 제작된 CsPbBr3 선량계가 근접방사선치료용 선량계로 활용 가능한 것으로 보여주었다.

방사선근접치료 분야의 선량 측정을 위해 제조된 Lead(II) Iodide 선량계의 적용가능성 연구 (The Study on Applicability of Manufactured Lead(II) Iodide Dosimeter for Dose Measurement in Brachytherapy)

  • 양승우;한무재;박성광
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.789-794
    • /
    • 2021
  • 근접방사선치료는 방사선동위원소를 신체 내부에 넣어 종양에 방사선을 집중적으로 조사하는 치료법이다. 근접방사선 치료는 고선량율의 방사선동위원소 선원을 사용하기 때문에 정확한 선원의 위치 및 선량등을 파악하는 것이 매우 중요하다. 하지만 임상에서는 ruler, autoradiograph등을 통하여 육안으로 부정확하게 평가하는 실정이다. 이에 본 연구에서는 Lead(II) Iodide(PbI2) 물질을 사용하여 방사선근접치료에 사용할 수 있는 선량계를 개발하고, 재현성, 선형성, PID 항목을 분석하여 적용가능성을 평가하였다. 재현성 평가 결과, RSD 값은 1.41%로 평가기준 1.5%를 만족하였다. 선형성 평가결과, R2값은 0.9993으로 평가기준 0.9990을 만족하였다. PID 평가 결과 50% 선량 감약지점에서 거리의 역자승 법칙의 이론값과 비교하여 0.06 cm의 차이만을 나타내었다. 본 실험에서 제작된 선량계는 모든 평가에서 기준치를 만족하는 결과값을 나타내어 방사선근접치료 영역에서의 선량계 적용 가능성이 충분한 것으로 판단된다.

근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가 (Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation)

  • 이준성;김양수;김민걸;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발 (Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source)

  • 최태진;예지원;김진희;김옥배;이호준;한현수
    • Radiation Oncology Journal
    • /
    • 제20권3호
    • /
    • pp.283-293
    • /
    • 2002
  • 목적 : 고선량률의 Ir-192 선원을 이용한 근접조사의 모의촬영 영상을 개인컴퓨터(PC)에 입력하여 해부학적 영상에 선량분포를 구현하고 히스토그램, 선량-용적히스토그램 및 3차원 선량분포를 전산화하였다. 대상 및 방법 : 선량전산화에 이용된 선원은 원격근접조사장치(Buchler 3K, 독일)의 Co-60 대체선원으로 한국원자력 연구소와 공동으로 개발한 Ir-192이다. 선원 모양에 의존하는 선량분포의 비등방성은 선원을 미소 분할하여 구한 선량과 선원 중심에서 측방 기준점의 공중선량을 기준으로 규격화한 값을 이용하였다. 선원 주위의 조직선량은 선원 중심에서 측방으로 실측된 조직감쇠와 산란에 의한 보정계수와 에너지에 따른 공기 저지능에 대한 조직의 저지능 비로 공중-조직선량 변환계수를 적용하고 기준점에 대해 규격화한 선량률표를 검색하여 얻도록 하였다. 선량계획 전산화 과정에 모의촬영 영상입력, 선원입력과 선원의 축면 결정과 해부학적 영상을 이용한 선량분포와 점선량, 히스토그램 및 선량-용적 히스토그램을 구현하였다. 결과 : 저자들이 개발한 근접조사 선량계획시스템에는 선원모의촬영 영상을 스켄하여 비트맵 파일로 저장하고, 좌표원점과 확대율을 정해, 선원위치를 결정하고 선량분포와 선량분석 프로그램을 포함한 선량전산화를 구현하였다. 실험에 이용된 Ir-192 선원의 조직내 선량은 공중선량율과 조직에 의한 감쇠 및 산란에 의한 실험식을 이용하였다. 선원 중심에서 축상의 거리와 축에서 떨어진 거리에 따른 선량률표에서 행렬 검색하여 얻도록 하였다. 근접조사선량계획은 선원좌표 입력과 선원의 축면(principal plane)을 결정하여 선원이 포함된 평면상의 선량을 구현하였으며, 시뮬레이션 영상인 관상면과 시상면에 선량분포를 구현하였다. 선량-히스토그램에 의한 선량분포 분석은 임의의 해부학적 영상면 위에 커서가 놓인 위치의 선량 스켓치로 얻었다. 임상에 필요한 선량분석은 선원의 축에서 면의깊이를 이동하여 선량분포를 구할 수 있게 하였으며, 선량-용적 히스토그램과 3차원 선량분포를 구현하였다. 결론 : 고선량률 Ir-192를 이용하여 근접조사선량계획을 전산화하였으며, 선량분포의 분석에는 해부학적 영상의 선량분포와 선량-히스토그램, 선량-용적히스토그램을 구현하였으며, 선량분포의 면을 임의 선택할 수 있고 3차원 선량분포를 포함한 선량계획시스템을 준비하였다.

고선량률 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교연구 (Comparison of Calibration Methods of $^{192}\textrm{Ir}$ Sources for High Dose Rate Brachytherapy)

  • 허현도;박성용;이레나;신동오;권수일;노준규;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.192-196
    • /
    • 2004
  • 본 연구는 국내에서 이용되고 있는 고선량률 근접치료기에 사용되는 Ir-192 선원에 대하여 Farmer type전리함과 우물형 전리함을 이용하여 선원의 세기를 측정하여 제조사에서 제공된 값과의 오차를 확인하고 두 증기간의 오차를 비교하였다. 동일한 Ir-192가 장착되어 가동 중인 6개의 병원의 고선량률 근접치료기(microSelctron, Nucletron, Netherlands)를 대상으로 선원의 모델별로 구분하여 상품화된 교정 Jig와 우물형 전리함 시스템을 이용, 선원의 세기를 측정하고 제조사에서 제공된 값과 비교하여 오차를 구하였다. 교정용 Jig를 이용한 선원 세기의 오차범위는 -2.40~+3.12%이고 우물형 전리함의 경우 오차범위는 -3.31~0.00%를 나타내었다. 측정 결과 두 장비 모두 제조사에서 제공된 값과 비교하였을 때 ${\pm}5%$의 오차를 넘지 않았으므로 임상 적용에는 문제가 없다. 외국의 사고 사례 보고에 따르면 계산 값에 의존하지 말고 새로운 선원이 교체될때 반드시 치료에 사용되기 전에 측정 도구를 이용하여 방사능의 세기를 측정하고 계산된 값과 비교하여 오차범위 내에서 일치하는지에 대한 확인 절차과정을 거치는 것이 필요하다.

  • PDF

근접 방사선치료용 이리듐 선원의 선량분포에 대한 몬데칼로 시뮬레이션 (Monte Carlo Simulation for Dose Distributions from Ir-192 in Brachytherapy)

  • 김승곤;강정구;이정옥;정동혁;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.187-194
    • /
    • 2002
  • 본 연구에서는 근접 방사선치료용 Ir-192 선윈의 흡수선량에 관한 물리적 특성들을 몬테칼로 계산을 이용하여 조사하였다. 몬테칼로 계산은 EGS4 코드로 수행하였으며 이를 위하여 원통형 선원과 팬텀 그리고 에너지 분포의 입력과 처리가 가능한 사용자 코드를 작성하였다. 베타선에 대한 계산 결과, 베타선들은 선원과 0.5-5.0 cm 거리에서 전체 흡수선량에 평균 0.02% 기여하는 것으로 나타났다. 이것은 초기 베타선들이 선원과 밀봉물질에서 대부분 흡수를 당하지만 이 과정에서 발생한 저에너지 제동복사 광자들이 원거리까지 기여하기 때문이다. 밀봉물질에 의한 흡수선량의 변화는 백금으로 취한 경우에 평균 2.8% 그리고 철로 취한 경우에 평균 1.1% 감소하는 것으로 나타났다. 몬테칼로 계산으로 구한 반경선량함수는 선원과 0.5-10.0 cm 반경거리 구간에 대하여 TG-43 보고서의 값들과 $\pm$3% 이내로 일치하였다. 본 연구에서 작성한 사용자 코드는 다른 종류 및 다른 크기의 선원에 대해서도 계산을 수행할 수 있어서 근접 방사선치료용 선원의 생산 및 가공에 관한 연구에 다양하게 이용될 수 있다.

  • PDF