A Comparative Study on the Mechanical Properties of Plywood treated with Several Fire Retardant Chemicals (I) - Effect of Soaking Time on the Static Bending Strength of Treated Plywood - (수종(數種) 내화약제(耐火藥劑)로 처리(處理)된 합판(處理)의 기술적(技術的) 성질(性質)에 관(關)한 비교연구(比較硏究)(I) - 처리합판(處理處理)의 휨강도(强度)에 미치는 침지시간(浸漬時間)의 영향(影響) -)

  • Kim, Jong-Man;Chung, Woo-Yang;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.20-26
    • /
    • 1984
  • This study was carried out to investigate the influence of chemical type and its retention in the fire-retardant treated plywoods on the static bending strength, a property peculiar to plywood. Being soaked in 20% aqueous solution of $(NH_4)_2SO_4$, $NH_4H_2PO_4$, $(NH_4)_2HPO_4$. Borax-Boric acid and Minalith for 3 to 12 hours at three-hour intervals and redried at $120^{\circ}C$ in hot press, the treated plywoods were put to static bending test. The values of chemical treated plywoods in Stress at proportional limit, Modulus of elasticity, Modulus of rupture and Work per unit volume to proportional limit were widely higher than those of water treated plywoods(control) and Borax-Boric acid treatment showed the highest value in the four mechanical data. And the bending strength of fire-retardant treated plywoods increased with the extension of soaking time or the increase of chemical retention in themselves. Borix-Boric acid was the desirable fire-retardant for thin plywood in view of mechanical strength and soaking defects in this study.

  • PDF

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF

A Study on Combustion Property of Cellulose Insulation according to Particle Size (입도에 따른 셀룰로오스 단열재의 연소특성에 관한 연구)

  • Choi, Jeong-hwa;Kim, Hong;Yoo, Kyong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.62-67
    • /
    • 1996
  • The smouldering combustion of cellulose Insulation treated with boric acid - borax - aluminium sulfate as combustion retardants are examined by candle type combustibility tester. The flammability behavior of combustion process is LOI, Smouldering region, Smouldering, Flamming spread region and Flame spread region. In this experiment, Particle size of four examined LOI, L.Point, H.Point, at the biggest size show high LOI. The surface area is connected with thermal conduction. The phenomena of combustion transition are governed by quantity of combustible gas generation in heating zone of cellulose insulation.

  • PDF

Studies of the Smoke Emission from Cellulose Fiber Insulation (셀룰로오스 단열재의 연기발생에 관한 연구)

  • Kim, Hong;Kang, Young-Goo
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.2
    • /
    • pp.12-17
    • /
    • 1994
  • Smoke evolved from burning cellulose insulation treated with boric acid-borax-alum as combustion retardants has been studied using a light absorption method. It has been shown that the quantity of smoke are decreased with the increase of oxygen concentration. Applied fire retardants did not increase smoke generation from investigated cellulose insulation in range of themal degradation without flaming. These same fire retardants increased from in the range of flaming combustion. The results of this work have been analysed using imperical equation, which correlated the smoke density at oxygen content of combustion transition. This equation may be. $\sigma$=$\sigma$$_{T}$ exp{-7.24$\times$10$^{-7}$ ( $O_2$ $O_{2.T}$)}Where $O_2$is the concentration of oxygen in the oxidizing gas, and $O_{2.T}$ refers to oxygen concentration of combustion transition.n.n.n.

  • PDF

Smouldering Combustion of Cellulose Insulation and Its Transition to Flaming Combustion (석면 대체용 셀룰로오스 단열재의 연소전이에 관한 연구)

  • Kim, Hong;Kim, Ki-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.3
    • /
    • pp.14-21
    • /
    • 1992
  • The smouldering combustion of cellulose insulation treated with boric acid-borax-alum as combustion retardants are examined by Candle type combustibility tester. This sequence was examined quantitatively for longitudinal cylinder bed of cellulose insulation. Two configuration are possible, downward and upward smoulder spread ; both were investigated exprimentally. The smoulder spread velocity of cellulose insulation was 2.5cm/s -5.0cm/s in smoulder region. As results of critical oxygen content measurement, the effectiveness of alum as third combustion retardant are acceptable for flaming retardant effect. The phenomena of combustion transition are governed by quantity of commbustible gas generation In heating zone of cellulose insulation. The critial oxygen content are decreased with the increase of gas flow rate.

  • PDF

THE PARTICLE SIZE EFFECT ON COMBUSTION BEHAVIOR OF CELLULOSE INSULATION

  • Choi, Jeong-Hwa;Kim, Hong;Ryu, Kyong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.185-192
    • /
    • 1997
  • The combustion of cellulose insulation treated with Borax, Boric acid and Aluminum Sulfate as combustion retardants is examined by candle type combustion tester. The cellulose fibers in cellulose insulation are classified by diameter as less than 0.2mm, 0.2mm-0.5mm, 0.5mm-2mm and more than 2mm. The burning behavior of cellulose insulation are studied by LOI (Limit Oxygen Index: Beginning point of smoldering), L- point (Lower point of combustion transition from smoldering- flaming to flaming combustion), LOI, L-point and H-point rise with the increasing particle size of cellulose fibers because thermal decomposition rate of cellulose fiber decreases. The phenomena of combustion transition from smoldering to flaming combustion are determined by the generating rate of combustible gas and the formation rate of combustible gas mixture within the zone of cellulose fiber heated.

  • PDF

Effect of fire - retardant treatment and redrying on the mechanical properties of radiata pine (내화처리(耐火處理) 및 재건조(再乾操)가 라디에타소나무의 역학적(力學的) 성질(性質)에 미치는 영향(影響))

  • Chung, Doo-Jin;Jo, Jae-Sung;Yun, Ki-Eon;Kim, Jae-Jin;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 1999
  • The effect of fire-retardant treatment and redrying on the mechanical properties of radiata pine sapwood were evaluated. Small, clear specimens were treated with three different fire-retardant(FR) chemicals, borax-boric acid(BRX), minalith(MIN), and pyresote(PYR), with target retentions of 30 and 60kg/$m^3$, and then redried at maximum dry-bulb temperature of $25^{\circ}C$, $60^{\circ}C$, $80^{\circ}C$ or $110^{\circ}C$. Each specimen, including untreated and water-treated controls, was tested in static bending and in compression parallel to grain. The extent of strength reduction was dependent on the type of FR chemicals, retention, and redrying temperature, and a highly significant interaction existed between FR treatment and redrying temperature. Modulus of rupture(MOR) and work to maximum load(WML) were significantly decreased by FR treatment and redrying. None of three FR chemicals adversely affect modulus of elasticity (MOE) and maximum crushing strength(MCS). MOE of BRX treatment and MCS of both BRX and PYR treatment increased significantly compared to untreated controls. No significant differences existed between retention levels except for MOE and MCS of some combinations of FR chemicals and redrying temperatures. Although MOE and MCS was not significantly affected by any of the redrying temperatures, these properties were generally decreased with the increase in redrying temperature. The significant reduction in MOR and WML was observed in BRX treatment when dried at temperatures of $60^{\circ}C$ and above, and in MIN and PYR treatment when dried at temperatures of $80^{\circ}C$ and above. Consequently, BRX-treated radiata pine should not be redried at temperatures >$60^{\circ}C$, and MIN- and PYR-treated radiata pine should not be redried at temperatures > $80^{\circ}C$ where bending strength and energy-related properties are important design considerations.

  • PDF

Studies on Press Drying of Fire-Retardant Treated Plywood (내화처리합판(耐火處理合板)의 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Kim, Jong Man
    • Journal of Korean Society of Forest Science
    • /
    • v.56 no.1
    • /
    • pp.1-25
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable and can cause fire accidents. causing destruction of human life and property. To diminish the fire disaster, fire retardant plywood is indeed required. In the methods of manufacturing the fire retardant plywood, a soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions redrying of soaked plywood is of the utmost importance. In this study 3.5mm and 5.0mm thickness plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid minalith, and water solution, 1-, 3-, 6-, and 9 hour-soaking treatments in borax-boric acid and minalith, and 6- and 9 hours in the other chemicals were applied and after the treatment hot drying was applied to treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$ of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1) In the 9 hours-soaking treatment of fire retardants by hot and cold bath method, the chemical retentions of 3.5mm thickness plywood could be attained within the range ($1.125-2.25kg/(30cm)^3$) of minimum retention specification as follows: $1.353kg/(30cm)^3$ in monoammonium phosphate, $1.331kg/(30cm)^3$ in diammonium phosphate, $1.263kg/(30cm)^3$ in ammonium sulfate, $1.226kg/(30cm)^3$ in borax-boric acid. But the chemical retention, $0.906kg/(30cm)^3$, in minalith could not be attained within the range of minimum retention specification. And also in case of 5.0mm thickness plywood, chemical retentions, as $1.356kg/(30cm)^3$ and $1.166kg/(30cm)^3$ respectively, of ammonium sulfate and diammonium phosphate could be attained within the range minimum retention specification, but the other fire retardant chemicals could not. 2) In the 6- and - hours-soaking treatments of 3.5mm and 5.0mm thickness plywood, the drying curve sloped of chemical treated plywood was smaller than that of water treated. The drying rate related to thickness of treated plywood, was about three times as fast in 3.5mm thickness plywood compared with 5.0mm thickness plywood. 3) In the treatment at $120^{\circ}C$ of hot platen temperature, the drying rates of chemical-treated plywood showed the highest quantity in diammonium phosphate of 3.5mm and 5.0mm thickness plywood. But the drying rate of water treated plywood was highest during the 6- and 9 hours-soaking treatments. 4) The drying rate remarkably increased with proportion to increase of the platen temperature, and the values were respectively 1.23%/min., 6.54%/min., 25.75%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 3.5mm thickness plywood and 0.55%.min., 2.49%/min., 8.19%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 5.0mm thickness plywood. 5) In the fire retardant degree of chemical treated plywood, the loss in weight was the smallest in diammonium phosphate, next was in monoammonium phosphate and ammonium sulfate, and the greatest was in borax-boric acid and minalith. And the fire-retardant effect in burning time, flame-exhausted time and carbonized area were greatest in diammouniun phosphate, next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric acid and minalith.

  • PDF

Mechanical Behaviour of Non-Oxide Boride Type Ceramics Formed on The AISI 1040 Plain Carbon Steel

  • Sen, Saduman;Usta, Metin;Bindal, Cuma;UciSik, A.Hikmet
    • The Korean Journal of Ceramics
    • /
    • v.6 no.1
    • /
    • pp.27-31
    • /
    • 2000
  • A series experiments were performed to evaluate mechanical behavior of non-oxide boride type ceramics formed on the AISI 1040 plain carbon steel. Boronizing was performed in a slurry salt bath consisting of borax, boric acid, and ferro-silicon at $950^{\circ}C$ for 2-6h. The AISI 1040 steel used as substrate material was containing 0.4%C, 0.13%Si, 0.65%Mn, 0.02%P, 0.014%S. The presence of non-oxide boride type ceramics $Fe_2B $ and FeB formed on the surface of steel was confirmed by metallographic technique and X-ray diffraction (XRD) analysis. The hardness of borides measured via Vickers indenter with a load of 2N reached a microhardness of up to 1800 DPN. The hardness of unborided steel was 185 DPN. The fracture toughness of borides measured by means of Vickers indenter with a load of 10N was about 2.30 MPa.$m^{1/2}$. The thickness of boride layers ranged from 72$\mu\textrm{m}$ to 145$\mu\textrm{m}$. Boride layers have a columnar morphology.

  • PDF

Flexural Properties of Heat-Treatment Samama (Anthocephalus macrophyllus) Wood Impregnated by Boron and Methyl Metacrylate

  • CAHYONO, Tekat Dwi;DARMAWAN, Wayan;PRIADI, Trisna;ISWANTO, Apri Heri
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.76-85
    • /
    • 2020
  • This study was conducted to analyze the application of boron compounds, methyl methacrylate (MMA), and heat treatment (HT) on changes in the density, moisture content, and flexural properties of samama (Anthocephalus macrophyllus) wood. Samama wood was impregnated with borax (BX) and boric acid (BA) using a pressure method at 5 atm for 4 h. Afterwards, the wood was impregnated with MMA at the same pressure and duration. Finally, the samama wood was given HT at 90 ℃ and 180 ℃. The results indicate that there was a weight gain of 93.4% in the wood impregnated using BA and MMA monomer and HT at 90 ℃. Consequently, the wood's density increased by 82.3%. Increased MOE and MOR percentages of 32.2% and 29.4%, respectively, were also found. HT at 180 ℃ degraded the wood components and MMA, and consequently, the density, MOE, and MOR also decreased. The wood impregnated by BX, BA, and MMA, and subjected to HT also had decreased moisture content (MC). This research recommends that the application of boron (BX, BA) should be combined with an MMA monomer and HT at 90 ℃ as an alternative method to improve samama wood quality. If darker color is preferable, HT should be conducted at 180 ℃.