• Title/Summary/Keyword: bone densitometry

Search Result 60, Processing Time 0.023 seconds

Relationship of Bone Mineral Density Measured by Ultrasound Bone Densitometry and Body Composition or Backmuscle Strength (초음파방식으로 측정된 골밀도와 신체조성 및 배근력의 관계)

  • Lee, Won-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.721-728
    • /
    • 2019
  • The purpose of this study was to evaluate the relationship between bone mineral density (BMD) and body composition (BC) or backmuscle strength (BS). Sixty-one participants were measured by BMD using ultrasound bone densitometry and Inbody for BC (i.e., SLM=Soft lean mass, SMM=Skeletal muscle mass, FS=Fitness score. et al.), BS after self-questionnaire for life cycle. This study was performed after approving Institutional Review Board and obtaining the informed concent from all participants. Participants was divided into two group by BMD T-score; $T-score{\geq}-1.0$, T-score<-1.0. Statistical analysis was performed by using SPSS ver. 22.0(USA), Spearma test for correlation between BMD and BC or BS. BMD or SLM, BS was increased with increasing physical activity or body mass index. SMM or SMM, FS of BMD $T-score{\geq}-1.0$ group was higher than that of T-score <-1.0 group as well as BS(p>0.05). BMD T-score was correlated positively with SLM(r= 0.424) or SMM(r= 0.431) in men, as well as in women(p<0.05). BS was correlated positively with SLM or SMM, FS. BS was significantly positive correlated with BMD in women group (r= 0.591, p= 0.001), but not in men group. We concluded that BMD is the relationship with SLM or SMM, as well as BS in women.

Short Segment Fixation for Thoracolumbar Burst Fracture Accompanying Osteopenia : A Comparative Study

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Lee, Sung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • Objective : The purpose of this study was to compare the results of three types of short segment screw fixation for thoracolumbar burst fracture accompanying osteopenia. Methods : The records of 70 patients who underwent short segment screw fixation for a thoracolumbar burst fracture accompanying osteopenia (-2.5< mean T score by bone mineral densitometry <-1.0) from January 2005 to January 2008 were reviewed. Patients were divided into three groups based on whether or not bone fusion and bone cement augmentation procedure 1) Group I (n=26) : short segment fixation with posterolateral bone fusion; 2) Group II (n=23) : bone cement augmented short segment fixation with posterolateral bone fusion; 3) Group III (n=21) : bone cement augmented, short segment percutaneous screw fixation without bone fusion. Clinical outcomes were assessed using a visual analogue scale and modified MacNab's criteria. Radiological findings, including kyphotic angle and vertebral height, and procedure-related complications, such as screw loosening or pull-out, were analyzed. Results : No significant difference in radiographic or clinical outcomes was noted between patients managed using the three different techniques at last follow up. However, Group I showed more correction loss of kyphotic deformities and vertebral height loss at final follow-up, and Group I had higher screw loosening and implant failure rates than Group II or III. Conclusion : Bone cement augmented procedure can be an efficient and safe surgical techniques in terms of achieving better outcomes with minimal complications for thoracolumbar burst fracture accompanying osteopenia.

A Study of both Femurs Bone Densitometry's Difference for Exercise (운동유무에 따른 양측 대퇴골 골밀도 차이에 관한 연구)

  • Jang, Eun-Ju;Kim, Eun-Hye;Kim, Ho-Sung;Shin, Sang-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.73-76
    • /
    • 2009
  • Purpose: Bone mineral densitometry test region advised by ISCD (International Society for Clinical Densitometry) is both site in case of femur, whereas our medical center measures left femur except for few extraordinary cases. It is said that right-handers had higher mean femur BMD in the left side than in the right side, but the factor influence the femur BMD is unknown. Thus, we investigate whether testing left femur only is a adequate clinical diagnosis. Materials and Methods: Subjects were 209 right-handers and 20 left-handers patient in Asan Medical Center from July to August, 30 to 70 years of age ($51{\pm}6.7$). Subjects fill out the questionnaire on hand preference and taking regular exercise. Total BMDs of bilateral femur were measured with GE Lunar Prodigy advance densitometer, and the statistical soft ware SPSS 12.0 for windows was used for statistical analysis. Results: In the total sample of the exercise group (n=127), the difference of both femur mean BMDs are $0.001{\pm}0.127\;g/cm^2$ and the non-exercise group's (n=102) both femur difference is $0.002{\pm}0.126\;g/cm^2$, there is no significant difference. And in exercise group, classified according to hand preference, each t-value is shown at right handers (n=114) are 0.65, left handers (n=13) are -0.39. Also, In non-exercise group, right handers (n=95) are -0.78, left handers (n=7) are -0.64. In the 95% confidence limit, there was no statistically significant difference (p>0.05). Conclusions: In recently researchs, there have been differences between both femurs according to hand preference. However, Our study have no significant difference both femurs BMDs. Therefore we suggest that BMD measurement of femur has no problem only one side, except for particular case like femur operation.

  • PDF

Age-related Reference Intervals for Total Collagen-I-N-terminal Propeptide in Healthy Korean Population

  • Yoo, Jun-Il;Park, Ae-Ja;Lim, Yong Kwan;Kweon, Oh Joo;Choi, Jee-Hye;Do, Jae Hyuk;Kim, Sunjoo;Kim, Youngri;Ha, Yong-Chan
    • Journal of Bone Metabolism
    • /
    • v.25 no.4
    • /
    • pp.235-241
    • /
    • 2018
  • Background: Procollagen type I N-terminal propeptide (PINP) is one of the most clinically useful bone formation biomarkers. Therefore, the purpose of this study was to independently evaluate the performance of automated total PINP assay and established age- and gender- specific reference intervals for PINP in healthy Korean population. Methods: The imprecision, linearity, and detection capability of Elecsys total PINP assay was determined and reference interval was established using 599 serums from Korean population with normal bone mineral densities based on bone densitometry. Age groups were divided into 20s, 30s, 40s, 50s, 60s and over. Results: Elecsys total PINP had excellent performance in imprecision, linearity, and detection capability. When partitioning age groups in Korean male and female populations, there was significant difference in total PINP between different age groups. In male populations, PINP level was decreased with increasing age, then it remained steady after middle-age. In female populations, there was a decreasing tendency similar to that in the male population with a sharp increase in the 50 to 59 age group. Conclusions: Elecsys total PINP assay showed precise and reliable performance in our study. We established age-related PINP reference intervals for Korean male and female population with normal bone mineral densities.

The Precision Test Based on States of Bone Mineral Density (골밀도 상태에 따른 검사자의 재현성 평가)

  • Yoo, Jae-Sook;Kim, Eun-Hye;Kim, Ho-Seong;Shin, Sang-Ki;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.67-72
    • /
    • 2009
  • Purpose: ISCD (International Society for Clinical Densitometry) requests that users perform mandatory Precision test to raise their quality even though there is no recommendation about patient selection for the test. Thus, we investigated the effect on precision test by measuring reproducibility of 3 bone density groups (normal, osteopenia, osteoporosis). Materials and Methods: 4 users performed precision test with 420 patients (age: $57.8{\pm}9.02$) for BMD in Asan Medical Center (JAN-2008 ~ JUN-2008). In first group (A), 4 users selected 30 patient respectively regardless of bone density condition and measured 2 part (L-spine, femur) in twice. In second group (B), 4 users measured bone density of 10 patients respectively in the same manner of first group (A) users but dividing patient into 3 stages (normal, osteopenia, osteoporosis). In third group (C), 2 users measured 30 patients respectively in the same manner of first group (A) users considering bone density condition. We used GE Lunar Prodigy Advance (Encore. V11.4) and analyzed the result by comparing %CV to LSC using precision tool from ISCD. Check back was done using SPSS. Results: In group A, the %CV calculated by 4 users (a, b, c, d) were 1.16, 1.01, 1.19, 0.65 g/$cm^2$ in L-spine and 0.69, 0.58, 0.97, 0.47 g/$cm^2$ in femur. In group B, the %CV calculated by 4 users (a, b, c, d) were 1.01, 1.19, 0.83, 1.37 g/$cm^2$ in L-spine and 1.03, 0.54, 0.69, 0.58 g/$cm^2$ in femur. When comparing results (group A, B), we found no considerable differences. In group C, the user_1's %CV of normal, osteopenia and osteoporosis were 1.26, 0.94, 0.94 g/$cm^2$ in L-spine and 0.94, 0.79, 1.01 g/$cm^2$ in femur. And the user_2's %CV were 0.97, 0.83, 0.72 g/$cm^2$ L-spine and 0.65, 0.65, 1.05 g/$cm^2$ in femur. When analyzing the result, we figured out that the difference of reproducibility was almost not found but the differences of two users' several result values have effect on total reproducibility. Conclusions: Precision test is a important factor of bone density follow up. When Machine and user's reproducibility is getting better, it’s useful in clinics because of low range of deviation. Users have to check machine's reproducibility before the test and keep the same mind doing BMD test for patient. In precision test, the difference of measured value is usually found for ROI change caused by patient position. In case of osteoporosis patient, there is difficult to make initial ROI accurately more than normal and osteopenia patient due to lack of bone recognition even though ROI is made automatically by computer software. However, initial ROI is very important and users have to make coherent ROI because we use ROI Copy function in a follow up. In this study, we performed precision test considering bone density condition and found LSC value was stayed within 3%. There was no considerable difference. Thus, patient selection could be done regardless of bone density condition.

  • PDF

[ $^{99m}Tc$ ]-MDP Bone Scintigraphy Findings Representing Osteoporosis ($^{99m}Tc$-MDP 골스캔에서 골다공증을 시사하는 소견)

  • Nam, Dae-Gun;Moon, Tae-Geon;Kim, Ji-Hong;Son, Seok-Man;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.161-167
    • /
    • 2001
  • Purpose: Bone scintigraphy with $^{99m}Tc$-labeled phosphates is one of the most common procedures in evaluation of various skeletal disorders. Metabolic bone diseases show involvement of the whole skeleton and are associated with increased bone turnover and increased uptake of $^{99m}Tc$-labeled phosphates. In this study, we investigated apparently normal women who were examined with routine bone scintigraphy applied bone densitometry to correlate it with skeletal uptake in bone scan. Materials and Methods: This study includes 79 women who were performed both of bone mineral density(BMD) and bone scintigraphy. We investigated the relation of bone scan findings and BMD of lumbar, femur, radius. Results: Regional BMD were negatively correlated with increased age. Among the bone scintigraphy findings representing metabolic bone disease, uptakes by the long bones, skull and mandible increased with age in women, while that in the costochondral junction decreased. Increased skull and mandible uptakes is associated with decreased BMD, and it has statistically significance. Conclusion: Our results show that increased radionuclide uptake in bone scintigraphy, especially skull and mandible uptake was associated with decreased lumbar, femur BMD in women. So that, increased skull and mandible uptake in women would be a scintigraphic sign of osteopenia of osteoporosis.

  • PDF

A comparative study of the quantitative assessment on the panoramic and intraoral radiographs (파노라마 방사선사진과 구내 방사선사진에서 골조직 정량평가의 비교연구)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.129-133
    • /
    • 2001
  • Purpose: To compare the copper equivalent values measured at premolar and molar areas in the copper equivalent images of panoramic and intraoral radiographs and to evaluate the possibility of the copper equivalent images of panorama for the assessment the bone density. Materials and Methods : Intraoral radiograms at mandibular premolar and molar area and panoramas of 6 human dry skulls were taken with copper-step wedge by Heliodent MD (Siemens Co., Germany) and by Planmeca (PM 2002 CC, Planmeca, Helsinki, Finland) were used for experiment. The copper equivalent values measured at premolar and molar areas in the copper equivalent im ages of panorama and intraoral film were compared. Results: The copper equivalent values were ranged 0.20 mmCu-0.44 mmCu at the molar areas, 0.05 mmCu-0.31 mmCu at the premolar areas on panoramic images. There were no significant differences (p>0.5) between the copper equivalent values on intraoral images and those on panoramic images measured at premolar areas and molar areas respectively. The correlation coefficient between the copper equivalent values on intraoral images and those on panoramic images was respectively 0.8495 at molar areas and 0.6184 at premolar areas. Conclusions : The copper equivalent images of panorama for the assessment the bone density appeared to be significant at molar area compared with the one of intraoral radiograph.

  • PDF

The Effects of Bone Regeneration of the Dermal Collagen Matrix(AlloDerm®) Graft in the Rabbit Calvarium (가토의 두개골에 이식한 진피 아교기질(AlloDerm®)이 골 재생에 미치는 효과)

  • Park, Sang Woo;Lee, Kyung Suck;Kim, Jun Sik
    • Archives of Plastic Surgery
    • /
    • v.32 no.3
    • /
    • pp.335-342
    • /
    • 2005
  • This study was undertaken to investigate possibility of the allogenic type I collagen inducing osteoinduction or osteoconduction at critical sized bone defect in the rabbit. Twenty Newzealand white rabbit, weighted from 2.8 kg to 3.5 kg, were used in this study. The skull was exposed and two bony defects were created with diameter of 10 mm. Group I(n=10), the bony defects was grafted from the other side bone. Group II(n=10), the bony defects was grafted by the allogenic type I collagen with bone morphogenic protein(BMP). Group III(n=10), the bony defects was grafted by the allogenic type I collagen only. Group IV(n=10), the bony defects was lefted with no grafts. The grafted bones and allogenic type I collagen were investigated with radiologic densitometry, histologic analysis and immunohistochemistry after 12 weeks. No major difference was observed in the gross finding between Group I, II, III, but dura mater was exposed in bony defect,the Group IV. The radiologic study demonstrated more bony opacity in the Group I, but the other groups did not demonstrate a significant difference. In the histologic study, grafted bone edge was completely consolidated with original bone in group I and new bone ingrew into the grafted allogenic type I collagen(group II, III),but there is no bone regeneration from the original bony edge in the group IV. The percent of the new bone formation by cross-sectional area was considered statistically significant at a p value of less than 0.05(p<0.05). In the immunohistochemistry study about BMP antibodies, the group IV demonstrated osteogenic activity in front of advancing original bone edge, in which the osteoblast stained strongly for BMP antibodies, but other group does not demonstrated any osteoblastic expression. There was no immunologic rejection. In conclusion, this results do not demonstrate that the allogenic type I collagen is useful for bone substitute, but the characters of the collagen, such as pliability, easy-handling, sponge-like structure, are useful in interpositional bone graft substitutes. The further evaluation of long term results about the resorption, immunologic tissue reaction, response of applied tissue growth factor to the allogenic collagen is needed.

Cross-Calibration of Domestic Devices and GE Lunar Prodigy Advance Dual-Energy X-Ray Densitometer Devices for Bone Mineral Measurements (국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Kyoung-Ah;Lee, In-Ja;Kim, Jung-Min
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.27-31
    • /
    • 2017
  • Reliable follow-up of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA) is essential in clinical practice. When there is a difference in the BMD values from DXA systems in the same patient, cross calibration equation is required for the reliable follow-up. Unfortunately, no equation is existed in BMD measure between GE Lunar Prodigy Advance (US, GE Healthcare; LPA) and Osteosys Dexxum T (Korea, Osteosys; ODT) DXA systems. In this study, we evaluate the agreement of BMD values between LPA and ODT and suggest the cross calibration equation using European spine phantom (ESP) with two systems. We performed BMD measurements using ten scans with ESP in each DXA systems. We compared BMD values and calculated cross calibration equation by linear regression analysis. The comparison between the LPA and ODT bone densitometers used the ESP. Compared to the ESP BMD values, ODT underestimated 14.36% and LPA overestimated 12.96%. The average of total BMD measurement values acquired with ODT were 21.44% lower than those from LPA. Cross-calibration equation for LPA and ODT was derived from ESP. We calculated simple cross calibration equation for LPA and ODT DXA systems. Cross-calibration equation is necessary for the reliable follow-up of BMD values in two different systems.

BMD Analysis according to the Obesity Index in a Group of Adults (비만도에 따른 성인들의 집단별 골밀도 분석)

  • Kim, Sun-Geun;Kweon, Dae-Cheol;Oh, Chan-Ho;Song, Woon-Heung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.51-58
    • /
    • 2008
  • Obesity which causing many physical and psychological problems is difficult to treatment. The purpose study was investigate relationships between weight, height, body mass index (BMI) and BMD of according to the low, normal, over, obesity, high group. According to obesity index, each group was divided into five proup. Study subjects were man(n=135) and woman(n=145). We checked the BMD of femoral neck and lumbar spine by using dual energy X-ray bone densitometry. Weight was positively correlation with height (p<0.05) by Pearson's correlation matrix. There was a significant difference in BMD of femoral neck and lumbar spine between four(low, normal, over, obesity) groups except for high obesity groul.

  • PDF